Search NASA⌕ Search

SEARCH · Search NASA

Results for “IODINE 140”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Iodine monofluoride 140-kW laser - Small signal gain and operating parameters

Output energies in excess of 4 mJ in a 30-nsec FWHM pulse (140-kW peak power) have been obtained from a discharge-pumped IF laser for a cavity output coupling of 35%. In addition, oscillation on a new transition of the IF (E-A) band at 472.7 nm has been observed. By measurement of the output power of the laser for various values of output mirror transmission, the small signal gain and loss coefficients were found to be (3.1 + or - 0.7)%/cm and 0.3%/cm, respectively.

Dlabal, M. L.↗

Nuclear Data Sheets for A=140☆

The 2006 evaluation of A=140 was updated using experimental results published before November 2018 from the various reaction and decay studies leading to the nuclei {sup 140}Sb, {sup 140}Te, {sup 140}I, {sup 140}Xe, {sup 140}Cs, {sup 140}Ba, {sup 140}La, {sup 140}Ce, {sup 140}Pr, {sup 140}Nd, {sup 140}Pm, {sup 140}Sm, {sup 140}Eu, {sup 140}Gd, {sup 140}Tb, {sup 140}Dy, {sup 140}Ho. These data are summarized and presented, together with adopted level schemes and properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-FG-207B-10: Dual-Energy CT Monochromatic Image Consistency Across Vendors and Platforms

Purpose: Although dual-energy CT provides improved sensitivity of HU for certain tissue types at lower simulated energy levels, if these values vary by scanner type they may impact clinical patient management decisions. Each manufacturer has selected a specific dual-energy CT approach (or in one case, three different approaches); understanding HU variability among low monochromatic images may be required when more than one dual-energy CT scanner type is available for use. Methods: A large elliptical dualenergy quality control phantom (Gammex Inc.; Middleton, WI) containing several standard tissue type materials was scanned at least three times on each of the following systems: GE HD750, prototype GE Revolution CT with GSI, Siemens Flash, Siemens Edge, Siemens AS 128, and Philips IQon. Images were generated at 50, 70, and 140 keV. Soft tissue and Iodine HU were measured on a single central 5mm-thick image; NIST constants were used to calculate the ideal HU for each material. Scan acquisitions were approximately dose-matched (∼25mGy CTDIvol) and image parameters were held as consistent as possible (thickness, kernel, no noise reduction). Results: Measured soft tissue (29 HU at 120 kVp) varied from 28 HU to 44 HU at 50 keV (excluding one outlier), from 21 HU to 31 HU at 70 keV, and from 19 HU to 32 HU at 140 keV. Measured iodine (5mg/ml, 106 HU at 120 kVp) varied from 246 HU to 280 HU at 50 keV, from 123 HU to 129 HU at 70 keV, and from 22 HU to 32 HU at 140 keV. Conclusion: Measured HU in standard rods across 3 dual-energy CT manufacturers and 6 scanner models varied directly with monochromatic level, with the most variability was observed at 50 keV and least variability at 70keV. Future work will include additional scanner platforms and how measurement variability impacts radiologists. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

The interhalogens IF and ICI as visible oscillators or amplifiers

The kinetic and spectroscopic properties of the interhalogens are reviewed, with emphasis on the iodine-monochloride (ICl) and iodine-monofluoride (IF) systems; the latter having produced 140 kW, 30 nsec FWHM pulses at 491 and 485 nm and may be scaled to the tens of millijoules per pulse level. Gain in excess of 1.0%/cm was observed across the entire IF blue-green band, demonstrating potentially wide tunability. Although ICl has not yet lased, its peak small-signal gain of 1.3%/cm and negligible background absorption in discharge plasmas make it an attractive candidate for a violet amplifier. The formation kinetics of IF- and ICl-excimer lasers in electron beam or discharge-produced plasmas, and the potential and limitations of these molecules as visible lasers or amplifiers are also discussed.

Eden, J. G.↗

Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging

Purpose: The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative reconstruction (ASiR-V) to correct for image noise arising from low tube voltage potential/tube current dynamic scanning, and image reconstruction algorithms to tackle beam-hardening, cone-beam, and partial-scan effects. Methods: Phantom studies were performed to investigate the effectiveness of image noise and artifact reduction with a GE Healthcare Revolution CT system for three acquisition protocols used in quantitative CT MP imaging: 100, 120, and 140 kVp/25 mAs. The heart chambers of an anthropomorphic chest phantom were filled with iodinated contrast solution at different concentrations (contrast levels) to simulate the circulation of contrast through the heart in quantitative CT MP imaging. To evaluate beam-hardening correction, the phantom was scanned at each contrast level to measure the changes in CT number (in Hounsfield unit or HU) in the water-filled region surrounding the heart chambers with respect to baseline. To evaluate cone-beam artifact correction, differences in mean water HU between the central and peripheral slices were compared. Partial-scan artifact correction was evaluated from the fluctuation of mean water HU in successive partial scans. To evaluate image noise reduction, a small hollow region adjacent to the heart chambers was filled with diluted contrast, and contrast-to-noise ratio in the region before and after noise correction with ASiR-V was compared. The quality of MP maps acquired with the CT system was also evaluated in porcine CT MP studies. Myocardial infarct was induced in a farm pig from a transient occlusion of the distal left anterior descending (LAD) artery with a catheter-based interventional procedure. MP maps were generated from the dynamic contrast-enhanced (DCE) heart images taken at baseline and three weeks after the ischemic insult. Results: Their results showed that the phantom and animal images acquired with the CT platform were minimally affected by image noise and artifacts. For the beam-hardening phantom study, changes in water HU in the wall surrounding the heart chambers greatly reduced from >±30 to ≤ ± 5 HU at all kVp settings except one region at 100 kVp (7 HU). For the cone-beam phantom study, differences in mean water HU from the central slice were less than 5 HU at two peripheral slices with each 4 cm away from the central slice. These findings were reproducible in the pig DCE images at two peripheral slices that were 6 cm away from the central slice. For the partial-scan phantom study, standard deviations of the mean water HU in 10 successive partial scans were less than 5 HU at the central slice. Similar observations were made in the pig DCE images at two peripheral slices with each 6 cm away from the central slice. For the image noise phantom study, CNRs in the ASiR-V images were statistically higher (p < 0.05) than the non-ASiR-V images at all kVp settings. MP maps generated from the porcine DCE images were in excellent quality, with the ischemia in the LAD territory clearly seen in the three orthogonal views. Conclusions: The study demonstrates that this CT system can provide accurate and reproducible CT numbers during cardiac gated acquisitions across a wide axial field of view. This CT number fidelity will enable this imaging tool to assess contrast enhancement, potentially providing valuable added information beyond anatomic evaluation of coronary stenoses. Furthermore, their results collectively suggested that the 100 kVp/25 mAs protocol run on this CT system provides sufficient image accuracy at a low radiation dose (<3 mSv) for whole-heart quantitative CT MP imaging.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP2-12: The Effect of Iterative Reconstruction and CT Tube Voltage On Hounsfield Unit Values of Iodinated Contrast

Purpose: To investigate the effects of changing iterative reconstruction strength and tube voltage on Hounsfield Unit (HU) values of varying concentrations of Iodinated contrast medium in a phantom. Method: Iodinated contrast (Omnipaque 300, GE Healthcare, Princeton NJ) was diluted with distilled water to concentrations of 0.6, 0.9, 1.8, 3.6, 7.2, and 10.8 mg/mL of Iodine. The solutions were scanned in a patient equivalent water phantom on two MDCT scanners: VCT 64 slice (GE Medical Systems, Waukesha, WI) and an Aquilion One 320 slice scanner (Toshiba America Medical Systems, Tustin CA). The phantom was scanned at 80, 100, 120, 140 kV using 400, 255, 180, and 130 mAs, respectively, for the VCT scanner, and 80, 100, 120, and 135 kV using 400, 250, 200, and 150 mAs, respectively, on the Aquilion One. Images were reconstructed at 2.5 mm (VCT) and 0.5 mm (Aquilion One). The VCT images were reconstructed using Advanced Statistical Iterative Reconstruction (ASIR) at 6 different strengths: 0%, 20%, 40%, 60%, 80%, and 100%. Aquilion One images were reconstructed using Adaptive Iterative Dose Reduction (AIDR) at 4 strengths: no AIDR, Weak AIDR, Standard AIDR, and Strong AIDR. Regions of interest (ROIs) were drawn on the images to measure the HU values and standard deviations of the diluted contrast. Second order polynomials were used to fit the HU values as a function of Iodine concentration. Results: For both scanners, there was no significant effect of changing the iterative reconstruction strength. The polynomial fits yielded goodness-of-fit (R2) values averaging 0.997. Conclusion: Changing the strength of the iterative reconstruction has no significant effect on the HU values of Iodinated contrast in a tissue-equivalent phantom. Fit values of HU vs Iodine concentration are useful in quantitative imaging protocols such as the determination of cardiac output from time-density curves in the main pulmonary artery.

60 APPLIED LIFE SCIENCES↗

Testing of an Iodine and Tritium Capture System for an NO₂-Based Tritium Pretreatment Process

The reprocessing of used nuclear fuel would release volatile radionuclides into the off-gas streams of a processing plant, including ³H, ¹⁴C, ⁸⁵Kr, and ¹²⁹I. One potential simplification to the management of the off-gas streams could be achieved through an efficient tritium pretreatment (TPT) step in which the UO₂ fuel is oxidized by either air or NO₂ before dissolution. The oxidation of the UO₂ fuel matrix will result in the release of tritium from the fuel. Upfront release of tritium from the fuel in a pretreatment step with subsequent tritium abatement can minimize or eliminate the distribution of tritium throughout a plant. This can decrease or eliminate the need for tritium capture on multiple off-gas streams and prevent distribution to the aqueous inventory. The use of NO₂ as the oxidant in an advanced tritium pretreatment (ATPT) allows for the oxidation to be performed at lower temperatures and may also result in the quantitative release of iodine from the fuel. The ATPT off-gas will contain up to 75 vol% NO₂ gas. Spencer et al. identified the most promising iodine sorbent as silver nitrate-impregnated alumina (AgA) and the most promising tritium sorbents as 3Å molecular sieve (3Å MS) and silica gel for radionuclide capture from ATPT off-gas streams. An initial series of tests were conducted in fiscal years 2017–2018 with the intent of demonstrating the recovery of iodine and tritium using these sorbents from a recirculating gas stream that simulated the NO₂ recycle loop envisioned for the ATPT system. These initial tests showed low tritium recoveries and significant variations in the iodine recovery on the AgA. Ultimately it was concluded, following disassembly of the system, that corrosion within the system was partially the cause of the poor recovery of both species. All components of that system were disposed of at the end of the analysis. One of the conclusions drawn from the initial tests pointed to the reconsideration of the materials of construction. Based on that recommendation a new test bed for the advanced TPT off-gas system, that addresses the issues identified in the fiscal years 2017 and 2018 scoping tests, was designed and constructed. The test bed used high nickel alloys wherever possible to address the previously observed corrosion issues, a redesigned surge tank to permit ease of purging, an improved feed injection system and a more modular system design that allowed testing of incremental increases in system complexity to allow the isolation of any element that results in changes to recovery of target species. Accompanying that design, a multifaceted test plan was completed. The overarching goals of this test series were two-fold. The first goal was to demonstrate the ability to recover both the iodine and tritium that would be released during TPT in a manner that the releases from the fuel can be quantified. The second goal was to demonstrate that the combined recovery system could operate in any of the three proposed TPT modes (once-through air or O₂, recirculating air or O₂, or recirculating NO x ). A total of 22 tests were completed. Ten tests examined tritium behavior under varying operating parameters, 8 tests examined iodine behavior under varying operating parameters, and 4 tests examined both tritium and iodine behavior. Silica gel was used for the tritium sorbent, and AgA or Ag-mordenite (AgZ) was used as the iodine sorbent. The following conclusions were drawn: Full recovery is achieved for both sorbates when no sorbent is in place indicating no accumulation within the test system. In even the simplest of the configurations (i.e., no sorbents in the columns), iodine is more difficult to transport and recover from the system than tritium. Analysis of the AgA iodine sorbent beds from the integrated tritium and iodine tests indicate quantitative iodine recovery can be achieved (within anticipated experimental errors). This system may provide a means for the quantification of the iodine released by the ATPT process within the experimental uncertainties. This would support 0.33 to 1.00 kg demonstrations of the ATPT process with actual used nuclear fuel. Iodine penetrated further into AgZ than into AgA when operated in gas recirculation mode. Tritium adsorbs to and cannot be fully recovered from the 10-cm column of silica gel at regeneration temperatures up to 140 °C.; Tritium adsorbs to and cannot be recovered from the 10-cm column of AgA at desorption temperatures up to 200 °C. Co-adsorbed tritium was recovered to a greater extent from AgZ than from AgA, but recovery was not complete. No visible corrosion was observed in the test system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Image quality comparison between single energy and dual energy CT protocols for hepatic imaging

Purpose: Multi-detector computed tomography (MDCT) enables volumetric scans in a single breath hold and is clinically useful for hepatic imaging. For simple tasks, conventional single energy (SE) computed tomography (CT) images acquired at the optimal tube potential are known to have better quality than dual energy (DE) blended images. However, liver imaging is complex and often requires imaging of both structures containing iodinated contrast media, where atomic number differences are the primary contrast mechanism, and other structures, where density differences are the primary contrast mechanism. Hence it is conceivable that the broad spectrum used in a dual energy acquisition may be an advantage. In this work we are interested in comparing these two imaging strategies at equal-dose and more complex settings. Methods: We developed numerical anthropomorphic phantoms to mimic realistic clinical CT scans for medium size and large size patients. MDCT images based on the defined phantoms were simulated using various SE and DE protocols at pre- and post-contrast stages. For SE CT, images from 60 kVp through 140 with 10 kVp steps were considered; for DE CT, both 80/140 and 100/140 kVp scans were simulated and linearly blended at the optimal weights. To make a fair comparison, the mAs of each scan was adjusted to match the reference radiation dose (120 kVp, 200 mAs for medium size patients and 140 kVp, 400 mAs for large size patients). Contrast-to-noise ratio (CNR) of liver against other soft tissues was used to evaluate and compare the SE and DE protocols, and multiple pre- and post-contrasted liver-tissue pairs were used to define a composite CNR. To help validate the simulation results, we conducted a small clinical study. Eighty-five 120 kVp images and 81 blended 80/140 kVp images were collected and compared through both quantitative image quality analysis and an observer study. Results: In the simulation study, we found that the CNR of pre-contrast SE image mostly increased with increasing kVp while for post-contrast imaging 90 kVp or lower yielded higher CNR images, depending on the differential iodine concentration of each tissue. Similar trends were seen in DE blended CNR and those from SE protocols. In the presence of differential iodine concentration (i.e., post-contrast), the CNR curves maximize at lower kVps (80–120), with the peak shifted rightward for larger patients. The combined pre- and post-contrast composite CNR study demonstrated that an optimal SE protocol has better performance than blended DE images, and the optimal tube potential for SE scan is around 90 kVp for a medium size patients and between 90 and 120 kVp for large size patients (although low kVp imaging requires high x-ray tube power to avoid photon starvation). Also, a tin filter added to the high kVp beam is not only beneficial for material decomposition but it improves the CNR of the DE blended images as well. The dose adjusted CNR of the clinical images also showed the same trend and radiologists favored the SE scans over blended DE images. Conclusions: Our simulation showed that an optimized SE protocol produces up to 5% higher CNR for a range of clinical tasks. The clinical study also suggested 120 kVp SE scans have better image quality than blended DE images. Hence, blended DE images do not have a fundamental CNR advantage over optimized SE images.

60 APPLIED LIFE SCIENCES↗

Divalent Anionic Doping in Perovskite Solar Cells for Enhanced Chemical Stability

The chemical stabilities of hybrid perovskite materials demand further improvement toward long-term and large-scale photovoltaic applications. Herein, the enhanced chemical stability of CH 3 NH 3 PbI 3 is reported by doping the divalent anion Se 2- in the form of PbSe in precursor solutions to enhance the hydrogen-bonding-like interactions between the organic cations and the inorganic framework. As a result, in 100% humidity at 40 degrees C, the 10% w/w PbSe-doped CH 3 NH 3 PbI 3 films exhibited >140-fold stability improvement over pristine CH 3 NH 3 PbI 3 films. As the PbSe-doped CH 3 NH 3 PbI 3 films maintained the perovskite structure, a top efficiency of 10.4% with 70% retention after 700 h aging in ambient air is achieved with an unencapsulated 10% w/w PbSe:MAPbI 3 -based cell. As a bonus, the incorporated Se 2- also effectively suppresses iodine diffusion, leading to enhanced chemical stability of the silver electrodes.

14 SOLAR ENERGY↗

High power rechargeable magnesium/iodine battery chemistry

Rechargeable magnesium batteries have attracted considerable attention because of their potential high energy density and low cost. However, their development has been severely hindered because of the lack of appropriate cathode materials. Here we report a rechargeable magnesium/iodine battery, in which the soluble iodine reacts with Mg 2+ to form a soluble intermediate and then an insoluble final product magnesium iodide. The liquid–solid two-phase reaction pathway circumvents solid-state Mg 2+ diffusion and ensures a large interfacial reaction area, leading to fast reaction kinetics and high reaction reversibility. As a result, the rechargeable magnesium/iodine battery shows a better rate capability (180 mAh g –1 at 0.5 C and 140 mAh g –1 at 1 C) and a higher energy density (~400 Wh kg –1 ) than all other reported rechargeable magnesium batteries using intercalation cathodes. As a result, this study demonstrates that the liquid–solid two-phase reaction mechanism is promising in addressing the kinetic limitation of rechargeable magnesium batteries.

25 ENERGY STORAGE↗

Binding and activation of major histocompatibility complex class II-deficient macrophages by staphylococcal exotoxins

Macrophages from C2D transgenic mice deficient in the expression of major histocompatibility complex (MHC) class II proteins were used to identify binding sites for superantigens distinct from the MHC class II molecule. Iodinated staphylococcal enterotoxins A and B (SEA and SEB) and exfoliative toxins A and B (ETA and ETB) bound to C2D macrophages in a concentration-dependent and competitive manner. All four toxins increased F-actin concentration within 30 s of their addition to C2D macrophages, indicating that signal transduction occurred in response to toxin in the absence of class II MHC. Furthermore, ETA, ETB, SEA, and, to a lesser extent, SEB induced C2D macrophages to produce interleukin 6. Several molecular species on C2D macrophages with molecular masses of 140, 97, 61, 52, 43, and 37 kDa bound SEA in immunoprecipitation experiments. These data indicate the presence of novel, functionally active toxin binding sites on murine macrophages distinct from MHC class II molecules.

Non-NASA Center↗

A Long Cycle Life, Self-Healing Zinc-Iodine Flow Battery with High Power Density

A Zinc-iodine flow battery (ZIFB) with super long cycle life, high energy, power density and self-healing behavior was presented. The long cycle life was achieved by employing a low-cost porous polyolefin membrane with optimized pore structure and stable electrolytes. The pores in the polyolefin membrane can be filled with a solution containing oxidized I 3 - that can react with zinc dendrite. Therefore, by consuming zinc dendrite, the battery can self-recover from micro-short circuiting resulting from overcharging the battery. By using KI and ZnBr 2 as electrolytes and a high ion conductivity porous membrane, a very high power density can be achieved. As a result, the ZIFB exhibits an energy efficiency (EE) of 82% at 80 mA/cm 2 and 71% at 140 mA/cm 2 , which is 8 times higher than the currently reported for ZIFBs. In addition, a long cycling life of more than 1000 cycles over 3 months with an energy density of more than 80 Wh/L was obtained at 80 mA/cm 2 . Furthermore, a kW-class cell stack with an output of 700 W was assembled and continuously run for more than 300 cycles. We believe this ZIFB with its high power density, long cycle life, and high reliability can lead the way to development of new-generation, high-performance flow batteries.

Xie, Congxin↗

Highly Conductive Iodine and Fluorine Dual-Doped Argyrodite Solid Electrolyte for Lithium Metal Batteries

Sulfide-type argyrodite solid electrolytes (SEs) with halide doping have attracted serious interest. Although other halides such as Cl and Br have been found to enhance Li-ion transport in argyrodites, the direct synthesis of efficiently conductive Li 6 PS 5 I without postprocessing has rarely been investigated. In this work, we report the one-step synthesis of highly conductive Li 6 PS 5 I with an impressive ionic conductivity of 2.5 × 10 –4 S cm –1 at room temperature through a solvent-based method. Moreover, by introducing F – to partially replace I – , hybrid-doped argyrodites Li 6 PS 5 F x I 1–x (x = 0.25, 0.5, 0.75) have been synthesized. Li 6 PS 5 F 0.25 I 0.75 achieves the highest conductivity of 3.5 × 10 –4 S cm –1 due to the energetic preference for anion-disordering among F – /I – and S 2– , which facilitate faster Li transport as supported by density functional theory (DFT) calculations. With higher F content in argyrodites, Li 6 PS 5 F 0.75 I 0.25 displays the best electrochemical stability toward Li metal, as evidenced by long-term stable cycling in Li symmetric cells up to 1100 h. Solid-state Li metal batteries with an active cathode of Li 4 Ti 5 O 12 (LTO) display an initial specific capacity of 140 mAh g –1 and remain at 105 mAh g –1 after 200 cycles, suggesting great battery cycling performance. Furthermore, this research has developed new compositions in the argyrodite SE family which could lead to advancements in the development of solid-state Li metal batteries.

25 ENERGY STORAGE↗