Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION EXTRACTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effect of Coulomb collision on the negative ion extraction mechanism in negative ion sources

To improve the H{sup −} ion beam optics, it is necessary to understand the energy relaxation process of surface produced H{sup −} ions in the extraction region of Cs seeded H{sup −} ion sources. Coulomb collisions of charged particles have been introduced to the 2D3V-PIC (two dimension in real space and three dimension in velocity space particle-in-cell) model for the H{sup −} extraction by using the binary collision model. Due to Coulomb collision, the lower energy part of the ion energy distribution function of H{sup −} ions has been greatly increased. The mean kinetic energy of the surface produced H{sup −} ions has been reduced to 0.65 eV from 1.5 eV. It has been suggested that the beam optics of the extracted H{sup −} ion beam is strongly affected by the energy relaxation process due to Coulomb collision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement in the Mass Resolution of Single Particle Mass Spectrometry Using Delayed Ion Extraction

A specific delayed ion extraction (DIE) technique, which combines a standard rectangular extraction pulse with an exponential pulse, was introduced for a single particle mass spectrometry (SPMS) instrument, and it can focus ions in a wide mass range and results in a mass resolution improvement for the mass range of the studied ions. The experimental results indicate that the average mass resolution for positive ions is about 1000 when the mass-to-charge ratio (m/z) is greater than 70, and for negative ions, when the m/z is greater than 70, the average resolution can reach 2000. The highest mass resolutions achieved so far are 1260 for positive ions and 2400 for negative ions for SPMS, which are very beneficial for mass peak interpretation and chemical compound identification. The primary applications for atmospheric particle measurements show that the high mass resolution of SPMS with the DIE technique is very beneficial for the analysis of carbon and metallic element containing particles, and {sup 39}K{sup +} with C{sub 3}H{sub 3}{sup +} and {sup 41}K{sup +} and C{sub 3}H{sub 5}{sup +} in organic particles were successfully differentiated using SPMS. The results indicate that SPMS with DIE technique can significantly ease mass peak interpretation and improve the mass assignment ability during analysis. Furthermore, existing SPMS instruments can be improved by a facile retrofitting process to implement the DIE technique. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion extraction from positively biased laser-ablation plasma

Ions were extracted through a grounded grid from a positively biased laser-ablation plasma and the behaviors were investigated. Since the plasma was positively biased against the grounded wall, we could extract the ions without insulated gap. We confirmed formation of a virtual anode when we increased the distance between the grid and the ion collector. Results also indicated that when the ion flux from the ablation plasma exceeded a critical value, the current was strongly suppressed to the space charge limited level due to the formation of virtual anode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Metastable precipitation and ion–extractant transport in liquid–liquid separations of trivalent elements

The extractant-assisted transport of metal ions from aqueous to organic environments by liquid–liquid extraction has been widely used to separate and recover critical elements on an industrial scale. While current efforts focus on designing better extractants and optimizing process conditions, the mechanism that underlies ionic transport remains poorly understood. Here, we report a nonequilibrium process in the bulk aqueous phase that influences interfacial ion transport: the formation of metastable ion–extractant precipitates away from the liquid–liquid interface, separated from it by a depletion region without precipitates. Although the precipitate is soluble in the organic phase, the depletion region separates the two and ions are sequestered in a long-lived metastable state. Since precipitation removes extractants from the aqueous phase, even extractants that are sparingly soluble in water will continue to be withdrawn from the organic phase to feed the aqueous precipitation process. Solute concentrations in both phases and the aqueous pH influence the temporal evolution of the process and ionic partitioning between the precipitate and organic phase. Aqueous ion–extractant precipitation during liquid–liquid extraction provides a reaction path that can influence the extraction kinetics, which plays an important role in designing advanced processes to separate rare earths and other minerals.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary results concerning the simulation of beam profiles from extracted ion current distributions for mini-STRIKE

The Radio Frequency (RF) negative hydrogen ion source prototype has been chosen for the ITER neutral beam injectors due to its optimal performances and easier maintenance demonstrated at Max-Planck-Institut für Plasmaphysik, Garching in hydrogen and deuterium. One of the key information to better understand the operating behavior of the RF ion sources is the extracted negative ion current density distribution. This distribution—influenced by several factors like source geometry, particle drifts inside the source, cesium distribution, and layout of cesium ovens—is not straightforward to be evaluated. The main outcome of the present contribution is the development of a minimization method to estimate the extracted current distribution using the footprint of the beam recorded with mini-STRIKE (Short-Time Retractable Instrumented Kalorimeter). To accomplish this, a series of four computational models have been set up, where the output of a model is the input of the following one. These models compute the optics of the ion beam, evaluate the distribution of the heat deposited on the mini-STRIKE diagnostic calorimeter, and finally give an estimate of the temperature distribution on the back of mini-STRIKE. Several iterations with different extracted current profiles are necessary to give an estimate of the profile most compatible with the experimental data. A first test of the application of the method to the BAvarian Test Machine for Negative ions beam is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selective and Chemical-Free Removal of Toxic Heavy Metal Cations from Water Using Shock Ion Extraction

Electrochemical methods are known to have attractive features and capabilities when used for ion separations and water purification. In this study, we developed a new process called shock ion extraction (shock IX) for selective and chemical-free removal of toxic heavy metals from water. Shock IX is a hybrid process that combines shock electrodialysis (shock ED) and ion exchange using an ion exchange resin wafer (IERW), and this method can be thought of functionally as an electrochemically assisted variation of traditional ion exchange. In particular, shock IX exhibits greater ion removal and selectivity for longer periods of time, compared to the use of ion exchange alone. Here, the use of an IERW in shock ED also increases multivalent ion selectivity, reduces energy consumption, and improves the hydrodynamics and scalability of the system.

54 ENVIRONMENTAL SCIENCES↗

Performance limits of ion extraction systems with non-circular apertures

A three-dimensional computer simulation is used to determine the perveance limitations of ion extraction systems with non-circular apertures. The objective of the study is to analyze the possibilities to improve mechanical strength of the ion optics made of carbon-carbon composite materials. Non-circular grid apertures are better suited to the physical structure of carbon-carbon composite materials, than conventionally used circular holes in a hexagonal pattern, because they allow a fewer number of cut fibers. However, the slit-type accelerating systems, usually regarded as the main alternative to the conventional ion optics, have an intolerably narrow range of operating perveance values at which there is no direct ion impingement on the acceleration grid. This paper presents results of comparative analysis of a number of different ion optical systems with non-circular apertures and conventional ion optical systems with circular apertures. It has been revealed that a relatively wide perveance range without direct ion impingement may be obtained with apertures shaped as a square with rounded corners. Numerical simulations show that this geometry may have equivalent perveance range as the traditional geometry with circular apertures while being more mechanically robust. In addition, such important characteristics, as the effective transparency for both the ions and the neutral atoms, the height of the potential barrier reflecting the downstream plasma electrons and the angular divergence of the beamlet also can be very close to these parameters for the optics with circular apertures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metal ion extraction from brines

A material includes a porous particle that includes a metal ion imprinted polymer. The metal ion imprinted polymer is formed from a hydrophilic co-monomer, a metal containing polymerizable compound, and a cross-linking agent. The metal containing polymerizable compound includes at least one metal chelating ligand. The metal ion imprinted polymer includes a plurality of metal ion selective binding sites. A method includes flowing brine containing a metal ion through a reactor that includes the material. The method further includes discharging the brine from the reactor, contacting the porous particles with water, and pressurizing the reactor with carbon dioxide. The carbon dioxide reacts with the adsorbed metal ions to form a metal carbonate solution. The method further includes depressurizing the reactor to precipitate metal carbonate from the metal carbonate solution and discharging the metal carbonate solution from the reactor.

36 MATERIALS SCIENCE↗

The Effects of the CARIBU EBIS Trap Configuration on Extracted Ion Beam Characteristics

Recently the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) Electron Beam Ion Source (EBIS) charge breeder was commissioned at the Argonne Tandem Linear Accelerator System (ATLAS). Different EBIS trap configurations were used to investigate the effects on the extracted beam characteristics - intensities, timing, and energy spread. Results of the commissioning runs are presented; and implications regarding optimization of the charge breeder configuration are discussed.

Dickerson, Clayton↗

Regularities of salting-out and metal ion extraction by synergistic mixtures of potassium bis(alkylpolyoxyethylene)phosphate and alkylbenzyldimethylammonium chloride under polythermic conditions

The regularities of salting-out of a ionic associate formed by anionic oxyethylated surfactant (potassium bis(alkylpolyoxyethylene)phosphate) and cationic surfactant (alkylbenzyldimethylammonium chloride) with inorganic salts were studied. The possibility of using the ionic associate for thallium(III) and indium extraction in the presence of sodium chloride as a saltingout agent at 60 °C was proved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a pepper-pot emittance meter for diagnostics of low-energy multiply charged heavy ion beams extracted from an ECR ion source

Several fluorescent materials were tested for use in the imaging screen of a pepper-pot emittance meter that is suitable for investigating the beam dynamics of multiply charged heavy ions extracted from an ECR ion source. SiO{sub 2} (quartz), KBr, Eu-doped CaF{sub 2}, and Tl-doped CsI crystals were first irradiated with 6.52-keV protons to determine the effects of radiation damage on their fluorescence emission properties. For such a low-energy proton beam, only the quartz was found to be a suitable fluorescent material, since the other materials suffered a decay in fluorescence intensity with irradiation time. Subsequently, quartz was irradiated with heavy {sup 12}C{sup 4+}, {sup 16}O{sup 4+}, and {sup 40}Ar{sup 11+} ions, but it was found that the fluorescence intensity decreased too rapidly to measure the emittance of these heavy-ion beams. These results suggest that a different energy loss mechanism occurs for heavier ions and for protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for Continuous Monitoring of Electrospray Ion Formation

A method for continuously monitoring the performance of electrospray ionization without the addition of hardware or chemistry to the system is demonstrated. In the method, which we refer to as SprayDx, cluster ions with solvent vapor natively formed by electrospray are followed throughout the collection of liquid chromatography–selected reaction monitoring data. The cluster ion extracted ion chromatograms report on the consistency of the ion formation and detection system. The data collected by the SprayDx method resemble the data collected for postcolumn infusion of analyte. The response of the cluster ions monitored reports on changes in the physical parameters of the ion source such as voltage and gas flow. SprayDx is also observed to report on ion suppression in a fashion very similar to a postcolumn infusion of analyte. We anticipate the method finding utility as a continuous readout on the performance of electrospray and other atmospheric pressure ionization processes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extraction of ion beam from laser ion source for direct plasma injection scheme

Laser ion sources are expected to be used in various applications of heavy ion beam technology. The plasma direct injection scheme (DPIS) is a method in which ion beams extracted from a laser ion source are directly injected into a radio frequency quadrupole (RFQ) linear accelerator. In this study, a new shape of the plasma electrode with a concave surface for the DPIS was proposed to inject a converging beam to a cavity of RFQ accelerator. This approach allows the use of a large-diameter extraction electrode, which is not limited by the aperture of the RFQ electrode rods. The DPIS, using the concave surface electrode, was employed to accelerate C 6+ ion beams. The results indicated that both the beam current and the number of ions increased nearly twice with the proposed electrode shape compared to values obtained with the conventional electrode. This enhancement corresponded to the increased extraction area of the beam.

43 PARTICLE ACCELERATORS↗

Method for lithium extraction via ion exchange

Methods for extracting lithium from solutions containing lithium ions via reversible cation exchange with H+ are provided. The methods utilize metal oxide or metalloid oxide cation exchange materials having an active sublattice that preferentially bind Li+ cations, relative to both H+ and Na+, in a sample solution and preferentially bind H+, relative to Li+, in an acidic solution.

Snydacker, David H.↗

Amidoxime-functionalized materials and their use in extracting metal ions from liquid solutions

A method of producing a functionalized material that extracts metal ions from solution, the method comprising: (i) providing a precursor material having nitrile groups appended to its surface; and (ii) reacting said nitrile groups with hydroxylamine or a derivative thereof in the presence of a polar aprotic solvent at a temperature of 60-80° C. for at least 1 hour, to convert at least a portion of said nitrile groups to amidoxime and imide dioxime groups, followed by reaction with a base capable of hydrolyzing any remaining nitrile groups to carboxylic acid groups; wherein said functionalized material has a higher uranium absorption capacity than a functionalized material produced under same conditions except that the nitrile groups are reacted with hydroxylamine in only a protic solvent. The invention is also directed to functionalized materials produced by the above-described method, and methods for using the functionalized material for extracting metal ions from metal-containing solutions.

36 MATERIALS SCIENCE↗