Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Two-Color IRMPD Applied to Conformationally Complex Ions: Probing Cold Ion Structure and Hot Ion Unfolding

Two-color infrared multiphoton dissociation (2C-IRMPD) spectroscopy is a technique that mitigates spectral distortions due to nonlinear absorption that is inherent to one-color IRMPD. We use a 2C-IRMPD scheme that incorporates two independently tunable IR sources, providing considerable control over the internal energy content and type of spectrum obtained by varying the trap temperature, the time delays and fluences of the two infrared lasers, and whether the first or second laser wavelength is scanned. In this work, we describe the application of this variant of 2C-IRMPD to conformationally complex peptide ions. The 2C-IRMPD technique is used to record near-linear action spectra of both cations and anions with temperatures ranging from 10 to 300 K. In this work, we also determine the conditions under which it is possible to record IR spectra of single conformers in a conformational mixture. Furthermore, we demonstrate the capability of the technique to explore conformational unfolding by recording IR spectra with widely varying internal energy in the ion. The protonated peptide ions YGGFL (NH 3 + -Tyr-Gly-Gly-Phe-Leu, Leu-enkephalin) and YGPAA (NH 3 + -Tyr-Gly-Pro-Ala-Ala) are used as model systems for exploring the advantages and disadvantages of the method when applied to conformationally complex ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion-probe studies of artificially implanted ions in lunar samples

The ion microprobe at the Johnson Space Center was used to study depth profiles of artificially implanted ions in lunar samples. Five polished sections of typical mare basalts (12040 and 12018) were irradiated with nine different elements at two energies and the resulting concentrations were measured as a function of depth in the minerals plagioclase, pyroxene, and ilmenite. These preliminary simulation experiments were undertaken to determine whether the ion probe can be used to measure solar-wind-implanted elements on the surface of lunar rock crystals and soil grains and to study mechanisms for the redistribution. The results obtained so far demonstrate that depth profiles can indeed be measured with the ion probe. From estimated exposure times of mature soil grains and selected vug crystals, it appears possible (if difficult) to detect several solar-wind-implanted elements.

Zinner, E.↗

Detection of Metallic Compounds in Rocket Plumes Using Ion Probes

This grant experimentally verified that ion probes can consistently detect metallic compounds in a hybrid rocket plume. Two electrostatic detection methods were tested. The first method used an unbiased ion probe. It responded to collisions or near collisions with charged particulates. The amplitude of the response to metallic ions always exceeded that of the combustion products. The second device was a cylindrical Gaussian surface that surrounded, but did not touch, the plume. A charge imbalance in the plume induced a current in cylinder that was detected by a sensitive amplifier. The probe was more sensitive to metallic compounds than the cylinder. However, the Gaussian cylinder demonstrated sufficient sensitivity to warrant serious future consideration. Since the cylinder is nonintrusive, it is particularly attractive. Apparently, ions formed during combustion transfer to the metallic impurities. The formation of these metallic ions slows the ion recombination rate and helps preserve charges in the plume. The electrostatic detectors, in turn, respond to the charges carried by the metallic impurities.

Dunn, Robert W.↗

The use of the ion probe mass spectrometer in the measurement of hydrogen concentration gradients in Monel K 500

The ion probe mass spectrometer was used to measure hydrogen concentration gradients in cathodically charged Monel K 500. Initial work with the ion probe involved the calibration of the instrument and the establishment of a suitable experimental procedure for this application. Samples of Monel K 500 were cathodically charged in a weak sulfuric acid solution. By varying the current density, different levels of hydrogen were introduced into the samples. Hydrogen concentration gradients were taken by ion sputtering on the surface of these samples and monitoring the behavior of the hydrogen mass peak as a function of time. An attempt was made to determine the relative amounts of hydrogen in the bulk and grain boundaries by analyzing a fresh fracture surface with a higher proportion of grain boundary area. It was found that substantially more hydrogen was detected in the grain boundaries than in the bulk, confirming the predictions of previous workers. A sputter rate determination was made in order to establish the rate of erosion.

Truhan, J. J., Jr.↗

Ion probe determinations of the rare earth concentrations of individual meteoritic phosphate grains

A new ion probe method for quantitative measurements of the concentrations of all the REE down to the ppm level in 5-20 micron spots is presented. The first application of the method is the determination of REE abundances in meteoritic phosphates. Results are shown to be in good agreement with previous INAA and ion probe determinations. The merrillites in the St. Severin amphoterite are richer in REE than the apatites (the enrichment factors, for various REE, range from 2.3 to 14.2) in contradiction with the results of Ebihara and Honda (1983). Provided good standards for other mineral phases are found or implanted marker ion techniques are used, the method should find a wide range of applications for the study of both terrestrial and extraterrestrial crystals at the microscopic level.

Crozaz, G.↗

New Colorimetric and Fluorometric Fluoride Ion Probe Based on Anthra[1,9-cd]pyrazol-6(2H)-one

New colorimetric and fluorometric fluoride ion probe, anthra[1,9-cd]pyrazol- 6(2H)-one (1), was synthesized by one-step condensation. The probe 1 shows F{sup −}-selective color change from colorless to pink and appearance of red fluorescence. The fluorescence quantum yield of free probe 1 in DMSO was calculated to be 0.03. After addition of 15 equiv. of F{sup −}, its fluorescence quantum yield can be increased to 0.37. The analytical detection limit for F{sup −} was 2.8 × 10{sup − 7} M. {sup 1}H NMR analysis and DFT calculation show that the F{sup −}-induced colorimetric and fluorometric responses of 1 are driven by deprotonation process. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion probe beam experiments and kinetic modeling in a dense plasma focus Z-pinch

The Z-pinch phase of a dense plasma focus (DPF) emits multiple-MeV ions in a ∼cm length. The mechanisms through which these physically simple devices generate such high energy beams in a relatively short distance are not fully understood. We are exploring the origins of these large gradients using measurements of an ion probe beam injected into a DPF during the pinch phase and the first kinetic simulations of a DPF Z-pinch. To probe the accelerating fields in our table top experiment, we inject a 4 MeV deuteron beam along the z-axis and then sample the beam energy distribution after it passes through the pinch region. Using this technique, we have directly measured for the first time the acceleration of an injected ion beam. Our particle-in-cell simulations have been benchmarked on both a kJ-scale DPF and a MJ-scale DPF. They have reproduced experimentally measured neutron yields as well as ion beams and EM oscillations which fluid simulations do not exhibit. Direct comparisons between the experiment and simulations enhance our understanding of these plasmas and provide predictive design capability for accelerator and neutron source applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of lost alpha particle by concealed lost ion probe

Full orbit-following calculation is performed for the final orbit of the lost alpha particles, showing some orbits escaping from the last closed flux surface could be detected by a concealed lost ion probe (CLIP) installed under the shadow of the original first wall surface. While both passing and trapped orbits hit the same wall panel, detecting a trapped orbit by the CLIP is easier than detecting passing orbits. Whether the final orbit is detected or not is determined by the position of the reflection point. The CLIP successfully detects the trapped orbits, which are reflected before they hit to a first wall. Then the pitch angles of the orbits at the CLIP are close to and smaller than 90 deg. Optimization of the position of the CLIP in terms of broader detection window is investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Limitation of the Depth Resolution in TOF-SIMS Elemental Profiling: the Influence of a Probing Ion Beam

New data concerning the influence of a probing beam of bismuth ions on the depth resolution in elemental depth profiling by secondary ion mass spectrometry (SIMS) have been obtained on a TOF.SIMS-5 system using the principle of two separate ion beams. It is established that the existing criterion of nondestructive character of the probing beam, on which this principle is based, is insufficient. Additional processes must be taken into account so as to formulate a more adequate criterion. A regime of depth profiling is proposed that allows the depth resolution to be improved at low energies of sputtering ions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Computer simulation of supersonic rarefied gas flow in the transition region, about a spherical probe; a Monte Carlo approach with application to rocket-borne ion probe experiments

This report describes a Monte Carlo simulation of transition flow around a sphere. Conditions for the simulation correspond to neutral monatomic molecules at two altitudes (70 and 75 km) in the D region of the ionosphere. Results are presented in the form of density contours, velocity vector plots and density, velocity and temperature profiles for the two altitudes. Contours and density profiles are related to independent Monte Carlo and experimental studies, and drag coefficients are calculated and compared with available experimental data. The small computer used is a PDP-15 with 16 K of core, and a typical run for 75 km requires five iterations, each taking five hours. The results are recorded on DECTAPE to be printed when required, and the program provides error estimates for any flow field parameter.

Horton, B. E.↗

Photoluminescence Probes Ion Insertion into Amorphous and Crystalline Regions of Organic Mixed Conductors

Abstract Organic mixed ionic‐electronic conductors (OMIECs) have emerged as promising materials for a wide range of next‐generation technologies, including bioelectronics and neuromorphic computing. The performance of these materials depends on the transport of ions through the polycrystalline polymer matrix as well as how the distribution of ions and polarons in crystalline and amorphous regions impacts electronic transport. However, it is often challenging to distinguish whether ions enter crystalline or amorphous regions. In this work, steady‐state and time‐resolved photoluminescence (PL) spectroelectrochemistry is used to probe initial ion insertion in crystalline and amorphous regions of the OMIEC material poly(3‐[2‐[2‐(2‐methoxyethoxy)ethoxy]ethyl]thiophene ‐2,5‐diyl) (P3MEEET) as a function of applied voltage. It is found that PL spectroelectrochemistry reports on the initial stages of electrochemical doping through the quenching of PL emission. By distinguishing between amorphous and crystalline contributions to the PL spectrum, ion insertion in crystalline and amorphous regions as a function of voltage is tracked. It is found that PL spectroelectrochemistry is much more sensitive to the initial injection of ions than complementary methods, highlighting its potential as a sensitive tool for interrogating ion injection in OMIECs.

Collins, Garrett W.↗