Sensitive Ion Pump Current Monitoring Using an In-House Built Ion Pump Power Supply

Ion pumps are common vacuum pumps on DC high voltage photoguns and baked-accelerator beamlines. Commercial ion pump power supplies provide a measure of the electrical current drawn by the pump, but typically have resolution to only {approx}0.1 uA, which corresponds to pressure {approx}10{sup -9} Torr, a value considerably higher than the minimum pressure required by photoguns and nearby beamline. This submission describes a very sensitive in-house-built ion pump power supply with current monitoring capability good to less than 1 nA, and corresponding pressure in the low-minus;10{sup -11} Torr range. Besides providing 'free' pressure monitoring on a scale equivalent to the best available commercial pressure gauges, the ion pump power supply also serves as a sensitive diagnostic for detecting field emission from the photogun cathode electrode and bad electron beam orbits that could diminish photogun operating lifetime. Since its inception, this ion pump power supply has become an invaluable tool for operating the CEBAF polarized electron source. It is also a very useful low-cost diagnostic for ultrahigh vacuum studies in the laboratory.

43 PARTICLE ACCELERATORS↗

Carbon ion pump for removal of carbon dioxide from combustion gas and other gas mixtures

A novel method and system of separating carbon dioxide from flue gas is introduced. Instead of relying on large temperature or pressure changes to remove carbon dioxide from a solvent used to absorb it from flue gas, the ion pump method, as disclosed herein, dramatically increases the concentration of dissolved carbonate ion in solution. This increases the overlying vapor pressure of carbon dioxide gas, permitting carbon dioxide to be removed from the downstream side of the ion pump as a pure gas. The ion pumping may be obtained from reverse osmosis, electrodialysis, thermal desalination methods, or an ion pump system having an oscillating flow in synchronization with an induced electric field.

Aines, Roger D↗

Carbon ion pump for removal of carbon dioxide from combustion gas and other gas mixtures

A novel method and system of separating carbon dioxide from flue gas is introduced. Instead of relying on large temperature or pressure changes to remove carbon dioxide from a solvent used to absorb it from flue gas, the ion pump method, as disclosed herein, dramatically increases the concentration of dissolved carbonate ion in solution. This increases the overlying vapor pressure of carbon dioxide gas, permitting carbon dioxide to be removed from the downstream side of the ion pump as a pure gas. The ion pumping may be obtained from reverse osmosis, electrodialysis, thermal desalination methods, or an ion pump system having an oscillating flow in synchronization with an induced electric field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reduction of waveguide vacuum trips in CEBAF accelerating cavities with a combination ion pump and non-evaporable getter pump

Pressure spikes in the fundamental power coupler waveguide are a significant source of trips during the operation of both original and refurbished superconducting radio-frequency cavities installed in the CEBAF accelerator. In its original configuration, two waveguides from a cavity-pair are connected to a single 32 l/s ion pump. In 2017 a new cavity-pair was installed in a refurbished cryomodule in which a NEXTorr® D200-5 combination ion pump and non-evaporable getter pump was installed for each waveguide. It is shown that hydrogen is the dominant residual gas in the waveguide and simulations with Molflow+ indicated that the new pumping scheme allows reducing the pressure at the end of the waveguide by a factor of ~5 , compared to the original configuration. In conclusion, the new cavity-pair has been operating in CEBAF for a total of 431 days and it only had a total of 3 trips due to vacuum spikes in the waveguide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Growth of microscopic cones on titanium cathodes of sputter-ion pumps driven by sorption of large argon quantities

Microscopic cones have been observed on titanium cathodes of sputter-ion pumps (SIPs) after pump operation. The cones were studied by means of scanning electron microscopy and energy dispersive x-ray analysis. Size and morphology of these cones are clearly correlated with the nature and the relative amount of each gas species pumped by each SIP during its working life. In particular, their growth was found to be fed by sputtering mechanisms, mostly during Ar pumping, and to be driven by the electromagnetic field applied to the Penning cells of each SIP. Experimental findings suggest that the formation and extent of such conic structures on cathode surfaces might play a leading role in the onset of phenomena typically related to the functioning of SIPs, e.g., the so-called argon instability.

36 MATERIALS SCIENCE↗

Early-stage dynamics of chloride ion–pumping rhodopsin revealed by a femtosecond X-ray laser

Chloride ion–pumping rhodopsin (ClR) in some marine bacteria utilizes light energy to actively transport Cl – into cells. How the ClR initiates the transport is elusive. Here, we show the dynamics of ion transport observed with time-resolved serial femtosecond (fs) crystallography using the Linac Coherent Light Source. X-ray pulses captured structural changes in ClR upon flash illumination with a 550 nm fs-pumping laser. High-resolution structures for five time points (dark to 100 ps after flashing) reveal complex and coordinated dynamics comprising retinal isomerization, water molecule rearrangement, and conformational changes of various residues. Combining data from time-resolved spectroscopy experiments and molecular dynamics simulations, this study reveals that the chloride ion close to the Schiff base undergoes a dissociation–diffusion process upon light-triggered retinal isomerization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient combining of ion pumps and getter-palladium thin films

Nonevaporable getters (NEGs) have been extensively studied in the last several years for their sorption properties toward many gases. In particular, an innovative alloy as a thin film by magnetron sputtering was developed and characterized at the European Organization for Nuclear Research. It is composed of Ti-Zr-V and protected by an overlayer of palladium (Pd), according to a technology for which the authors got the licence. NEG-Pd thin films used in combination with ion getter pumps is a simple, easy way to handle pumping devices for ultrahigh and extremely high vacuum applications. To show how to apply this coating technology to the internal surface of different types of ion pumps, the authors carried out several tests on pumps of various shapes, sizes (in terms of nominal pumping speed), and types (diode, noble diode, and triode). Special care was taken during the thermal cycle of baking and activation of the pumps to preserve the internal film from sources of contamination and/or from the sputtering of the titanium cathodes of the pump. Some important remarks will be made about the most appropriate conditions of pressure and temperature. The performance of the NEG-Pd-coated ion pumps was evaluated in terms of ultimate pressure and hydrogen pumping speed. The contribution of the thin film is particularly relevant for the pumping of this gas, due to its high sticking factor on palladium and the great sorption capacity of the underlying getter. Finally, the possibility of further improvement by substituting palladium with other Pd-based alloys will also be evaluated.

36 MATERIALS SCIENCE↗

pH Homeostasis and Sodium Ion Pumping by Multiple Resistance and pH Antiporters in Pyrococcus furiosus

Multiple Resistance and pH (Mrp) antiporters are seven-subunit complexes that couple transport of ions across the membrane in response to a proton motive force (PMF) and have various physiological roles, including sodium ion sensing and pH homeostasis. The hyperthermophilic archaeon Pyrococcus furiosus contains three copies of Mrp encoding genes in its genome. Two are found as integral components of two respiratory complexes, membrane bound hydrogenase (MBH) and the membrane bound sulfane sulfur reductase (MBS) that couple redox activity to sodium translocation, while the third copy is a stand-alone Mrp. Sequence alignments show that this Mrp does not contain an energy-input (PMF) module but contains all other predicted functional Mrp domains. The P. furiosus Mrp deletion strain exhibits no significant changes in optimal pH or sodium ion concentration for growth but is more sensitive to medium acidification during growth. Cell suspension hydrogen gas production assays using the deletion strain show that this Mrp uses sodium as the coupling ion. Mrp likely maintains cytoplasmic pH by exchanging protons inside the cell for extracellular sodium ions. Deletion of the MBH sodium-translocating module demonstrates that hydrogen gas production is uncoupled from ion pumping and provides insights into the evolution of this Mrp-containing respiratory complex.

59 BASIC BIOLOGICAL SCIENCES↗

Evidence of high-n hollow-ion emission from Si ions pumped by ultraintense x-rays from relativistic laser plasma

We report on the first observation of high- n hollow ions (ions having no electrons in the K or L shells) produced in Si targets via pumping by ultra-intense x-ray radiation produced in intense laser-plasma interactions reaching the radiation dominant kinetics regime (RDKR). The existence of these new types of hollow ions in high-energy density plasma has been found via observation of highly resolved x-ray emission spectra of silicon plasma. This has been confirmed by plasma kinetics calculations, underscoring the ability of powerful radiation sources to fully strip electrons from the innermost shells of light atoms. Hollow-ions spectral diagnostics provide a unique opportunity to characterize powerful x-ray radiation of laboratory and astrophysical plasmas. With the use of this technique we provide evidence for the existence of the RDKR via observation of asymmetry in the observed radiation of hollow ions from the front and rear sides of the target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deionization and desalination using electrostatic ion pumping

The present invention provides a new method and apparatus/system for purifying ionic solutions, such as, for example, desalinating water, using engineered charged surfaces to sorb ions from such solutions. Surface charge is applied externally, and is synchronized with oscillatory fluid movements between substantially parallel charged plates. Ions are held in place during fluid movement in one direction (because they are held in the electrical double layer), and released for transport during fluid movement in the opposite direction by removing the applied electric field. In this way the ions, such as salt, are "ratcheted" across the charged surface from the feed side to the concentrate side. The process itself is very simple and involves only pumps, charged surfaces, and manifolds for fluid collection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deionization and desalination using electrostatic ion pumping

The present invention provides a new method and apparatus/system for purifying ionic solutions, such as, for example, desalinating water, using engineered charged surfaces to sorb ions from such solutions. Surface charge is applied externally, and is synchronized with oscillatory fluid movements between substantially parallel charged plates. Ions are held in place during fluid movement in one direction (because they are held in the electrical double layer), and released for transport during fluid movement in the opposite direction by removing the applied electric field. In this way the ions, such as salt, are "ratcheted" across the charged surface from the feed side to the concentrate side. The process itself is very simple and involves only pumps, charged surfaces, and manifolds for fluid collection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗