Search NASA⌕ Search

SEARCH · Search NASA

Results for “IR absorption readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nanophotonic quantum sensing with engineered spin-optic coupling

Nitrogen vacancy centers in diamond provide a spin-based qubit system with long coherence time even at room temperature, making them suitable ambient-condition quantum sensors for quantities including electromagnetic fields, temperature, and rotation. The optically addressable level structures of NV spins allow transduction of spin information onto light-field intensity. The sub-optimal readout fidelity of conventional fluorescence measurement remains a significant drawback for room-temperature ensemble sensing. Here, we discuss nanophotonic interfaces that provide opportunities to achieve near-unity readout fidelity based on IR absorption via resonantly enhanced spin-optic coupling. Spin-coupled resonant nanophotonic devices are projected to particularly benefit applications that utilize micro- to nanoscale sensing volume and to outperform present methods in their volume-normalized sensitivity.

42 ENGINEERING↗

MEMS terahertz-to-infrared band converter using frequency selective planar metamaterial

A MEMS terahertz-to-infrared converter has been developed based on the unique properties of metamaterials that allow for selective control of the absorptivity and emissivity of the sensors. The converter consists of a sensing element structurally made of planar metamaterial membranes, connected to a substrate frame by four symmetrically-located thermal insulators. Upon THz absorption, the temperature of the sensing element increases and the outward infrared flux from the backside of the element is read by a commercial long-wave infrared camera. Two configurations were designed and fabricated with metamaterial absorptivity optimized for 3.8THz and 4.75THz quantum cascade lasers. The first sensor, fabricated with an oxidized aluminum backside, exhibits higher responsivity, but lower conversion efficiency than the second sensor, fabricated with a metamaterial backside. The spectral characteristics of the metamaterial on the two sides can be optimized to improve both responsivity and sensitivity, while keeping the sensors’ thermal time constant sufficiently small for real time imaging. No dedicated electronics or optics are required for readout making metamaterial-based MEMS THz-to-IR converters very attractive for THz imaging as means of a simple attachment to commercial IR cameras.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of absorbed dose to water around a clinical HDR {sup 192}Ir source using LiF:Mg,Ti TLDs demonstrates an LET dependence of detector response

Purpose: Experimental radiation dosimetry with thermoluminescent dosimeters (TLDs), calibrated in a {sup 60}Co or megavoltage (MV) photon beam, is recommended by AAPM TG-43U1for verification of Monte Carlo calculated absorbed doses around brachytherapy sources. However, it has been shown by Carlsson Tedgren et al.[Med. Phys. 38, 5539-5550 (2011)] that for TLDs of LiF:Mg,Ti, detector response was 4% higher in a {sup 137}Cs beam than in a {sup 60}Co one. The aim of this work was to investigate if similar over-response exists when measuring absorbed dose to water around {sup 192}Ir sources, using LiF:Mg,Ti dosimeters calibrated in a 6 MV photon beam. Methods: LiF dosimeters were calibrated to measure absorbed dose to water in a 6 MV photon beam and used to measure absorbed dose to water at distances of 3, 5, and 7 cm from a clinical high dose rate (HDR) {sup 192}Ir source in a polymethylmethacrylate (PMMA) phantom. Measured values were compared to values of absorbed dose to water calculated using a treatment planning system (TPS) including corrections for the difference in energy absorption properties between calibration quality and the quality in the users'{sup 192}Ir beam and for the use of a PMMA phantom instead of the water phantom underlying dose calculations in the TPS. Results: Measured absorbed doses to water around the {sup 192}Ir source were overestimated by 5% compared to those calculated by the TPS. Corresponding absorbed doses to water measured in a previous work with lithium formate electron paramagnetic resonance (EPR) dosimeters by Antonovic et al. [Med. Phys. 36, 2236-2247 (2009)], using the same irradiation setup and calibration procedure as in this work, were 2% lower than those calculated by the TPS. The results obtained in the measurements in this work and those obtained using the EPR lithium formate dosimeters were, within the expanded (k = 2) uncertainty, in agreement with the values derived by the TPS. The discrepancy between the results using LiF:Mg,Ti TLDs and the EPR lithium formate dosimeters was, however, statistically significant and in agreement with the difference in relative detector responses found for the two detector systems by Carlsson Tedgren et al. [Med. Phys. 38, 5539-5550 (2011)] and by Adolfsson et al.[Med. Phys. 37, 4946-4959 (2010)]. Conclusions: When calibrated in {sup 60}Co or MV photon beams, correction for the linear energy transfer (LET) dependence of LiF:Mg,Ti detector response will be needed as to measure absorbed doses to water in a {sup 192}Ir beam with highest accuracy. Such corrections will depend on the manufacturing process (MTS-N Poland or Harshaw TLD-100) and details of the annealing and read-out schemes used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗