Search NASA⌕ Search

SEARCH · Search NASA

Results for “IR thermography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Analysis of fast-ion losses measured in MAST-U via infrared thermography and a Fast Ion Loss Detector

Fast-ion losses need to be monitored to avoid damage to plasma facing components. In existing experimental devices, the scintillator-based fast-ion loss detector (FILD) is the most advanced diagnostic for measuring fast-ion losses. However, FILDs provide only local information about the losses. Infrared (IR) thermography can be used as a complementary tool for more global monitoring of the deposition of fast-ion losses on the wall, at the expense of no velocity-space resolution. IR cameras measure the temperature of the plasma facing components. This measurement, determined by a combined effect of the thermal plasma, radiation, neutrons and fast-ion losses, can be decomposed to infer the fast-ion load on the tokamak wall. In this manuscript, a workflow to estimate fast-ion losses via IR thermography is applied to the MAST-U spherical tokamak, using a 1D approximation to extract the experimental heat flux on the FILD front face from IR data. To numerically estimate the different contributions to this total heat flux, the field-line tracing environment SMITER is used to calculate the thermal plasma contribution, the orbit-following Monte-Carlo code ASCOT to estimate the fast-ion losses, and bolometry measurements for the radiation. To validate the workflow, two discharges, L-mode plasmas with low MHD activity, were executed using on and off-axis beams, respectively. The experimentally and numerically estimated heat flux are of the same order of magnitude for the on-axis heated scenario, with a strong dependence of the estimated fast-ion losses contribution on the fit to the kinetic profiles used as input. This is also true for the off-axis heated scenario, where the total numerically estimated heat flux is 2.1 or 1.3 times higher than the maximum experimentally estimated heat flux, depending on the ASCOT input used.

FILD↗

Infrared thermography NDT for in-situ defect detection in sandwich composite panel manufacturing

Composite manufacturing presents numerous challenges, as defects can arise from various sources throughout the process. In sandwich composite structures, the integration of a foam core introduces additional complexity and increases the likelihood of defect formation like delamination. To mitigate these issues and reduce the risk of future structural failures, in-situ monitoring during manufacturing is essential. This study investigates infrared (IR) thermography as a non-destructive technique for detecting manufacturing defects in foam-core sandwich composite panels under thermally excited conditions representative of in-situ processing. A stationary FLIR A8590 IR camera (640 × 512 pixels, 30Hz, 17mm lens, 9 ft stand-off distance) was used to monitor prefabricated panels subjected to controlled external heating simulating compression molding and resin cure exotherm. Interlaminar delamination defects with characteristic sizes ranging from 0.25 × 0.25in² to 5 × 5in² produced measurable surface temperature depressions of approximately 4–10°C during transient cooling, exceeding the effective noise floor of the camera by more than two standard deviations. Thicker laminates exhibited prolonged defect detectability windows due to increased thermal diffusion time. In contrast, embedded Teflon inclusions generated weak thermal contrasts of ≤ 3°C, approaching the measurement noise floor, due to limited thermal property contrast with the surrounding glass fiber composite. These results establish quantitative detectability limits for stationary thermographic inspection of sandwich composite panels under manufacturing-representative thermal cycles.

Barakat, Abdallah [ORNL] (ORCID:0000000296141398)↗

Visualization of Two-phase Flow Maldistribution in Brazed Plate Heat Exchangers

Brazed plate heat exchangers (BPHEs) are widely used in refrigeration and HVAC applications, but are susceptible to two-phase flow maldistribution especially when operated as evaporators. Existing visualization approaches are either limited to idealized conditions or suffer from poor optical transparency. This paper presents a novel visualization method in which one edge of a BPHE, parallel to the refrigerant inlet or outlet port, is removed by wire electrical discharge machining and replaced with a flat, transparent plate. The planar geometry allows the use of optically and infrared (IR)-transparent materials, enabling both high-speed videography and IR thermography of the two-phase flow at the channel entrances and exits. Preliminary tests with R134a and R1234ze(Z) at saturation temperatures between 5 °C and 15 °C demonstrate that distinct two-phase flow patterns in the inlet header can be clearly identified and differentiated under realistic operating conditions. Potentials of optical flow analysis of high-speed videos are shown to provide objective, quantitative indicators for flow regime characterization and comparison. IR imaging of the outlet port reveals non-uniform temperature distributions at the channel exits, providing independent evidence of maldistribution across the channel stack. Limitations of IR temperature accuracy due to the spectral properties of the sapphire window are discussed, and directions for improvement are identified.

Hausherr, Carsten [Technical University of Berlin ↗

Spatially resolved phase transformation mapping in 410 stainless steel during additive manufacturing visualized via real-time infrared data

Here, in this study, we demonstrate that spatially resolved cooling curves derived from real-time infrared (IR) thermography during additive manufacturing (AM) can capture spatial variations in phase transformation temperatures through cooling curve analysis (CCA). Using this approach, we show that during laser hot-wire deposition of 410 stainless steel (410SS), the martensite start temperature (M s ) evolves dynamically throughout the build. The M s temperature is spatially nonuniform, ranging from 185 °C to 348 °C, with the lowest values toward the build center and higher values toward the upper region of the deposit. In the lower portion of the build, no M s inflection is detected via CCA, consistent with transformation occurring earlier during thermal cycling followed by tempering during subsequent thermal cycles. These trends in M s are corroborated by characterizing the microstructure by electron backscatter diffraction (EBSD). Traditionally, M s is assumed to be constant, and a single interpass temperature is applied during both deposition and residual stress modeling. Our results demonstrate that IR-derived cooling curves provide a route to spatially and temporally resolved transformation temperature tracking for dynamic interpass control and improved residual-stress modeling.

Additive manufacturing↗

Infrared Optical Anisotropy in Quasi‐1D Hexagonal Chalcogenide BaTiSe 3

Polarimetric infrared (IR) detection bolsters IR thermography by leveraging the polarization of light. Optical anisotropy, i.e., birefringence and dichroism, can be leveraged to achieve polarimetric detection. Recently, giant optical anisotropy is discovered in quasi-1D narrow-bandgap hexagonal perovskite sulfides, A 1+x TiS 3 , specifically BaTiS 3 and Sr 9/8 TiS 3 . In these materials, the critical role of atomic-scale structure modulations in the unconventional electrical, optical, and thermal properties raises the broader question of the nature of other materials that belong to this family. To address this issue, for the first time, high-quality single crystals of a largely unexplored member of the A 1+x TiX 3 (X = S, Se) family, BaTiSe 3 are synthesized. Single-crystal X-ray diffraction determined the room-temperature structure with the P31c space group, which is a superstructure of the earlier reported P6 3 /mmc structure. The crystal structure of BaTiSe 3 features antiparallel c-axis displacements similar to but of lower symmetry than BaTiS 3 , verified by the polarization dependent Raman spectroscopy. Fourier transform infrared (FTIR) spectroscopy is used to characterize the optical anisotropy of BaTiSe 3 , whose refractive index along the ordinary (E ⊥ c) and extraordinary (E ‖ c) optical axes is quantitatively determined by combining ellipsometry studies with FTIR. With a giant birefringence Δn ∼ 0.9, BaTiSe 3 emerges as a new candidate for miniaturized birefringent optics for mid-wave infrared to long-wave infrared imaging.

optical anisotropy↗

The impact of hot-press conditions on the durability of polymer electrolyte membrane fuel cells

The proton exchange membrane integrity can be compromised during hot-press fabrication of membrane electrode assemblies (MEAs) causing premature cell failures during operation. In this work, infrared (IR) thermography was used as a diagnostic tool to spatially visualize hydrogen (H 2 ) crossover and identify process-induced-membrane irregularities (PIMs). These irregularities were identified as seed locations for MEA failures. Fine tuning of hot-press conditions was used to mitigate premature cell failures informed by accelerated stress testing (AST). The impact of PIMs on the initial performance, high-frequency resistances, open-circuit voltage, and H 2 crossover are reported. Nafion XL and 212 membranes, hot-pressed with a force of 16 kg/cm 2 and temperature of 120°C, were found to be consistently irregularity-free. Irregularity-free MEAs using Nafion 211, 212, and XL membranes demonstrated AST lifetime improvements of 58, 64 and 400%, respectively, compared to those fabricated with non-optimized conditions. In conclusion, this work highlights the importance of fabrication parameters on premature cell failures.

08 HYDROGEN↗

Relating Aerial Infrared Thermography Defects to Photovoltaic Performance: Preprint

In this research, we examine the relationship between aerial IR defect analysis and photovoltaic (PV) performance data for twelve utility- and commercial-scale solar sites in the United States. To do this, we fuse the site diagram geoJSON's, aerial infrared thermography (aIRT) defect analyses, and associated inverter time series, allowing for a direct comparison between site defects and time series data. Defect analyses were provided by Zeitview, under its Solar Insights platform. Following the data fusion process, we look at the relationship between system performance and aIRT defects. We investigate the relationship between degradation and hotspot defects, as well as the relationship between AC power data and offline strings and misaligned modules. In general, system degradation was not affected by long-term or balance-of-system (BoS) defects as they occurred infrequently in the data set. However, for one system, a near statistically significant relationship (p-value=0.057) was found when comparing the degradation of inverter blocks with several multi-hotspot defects to all other inverter blocks without this particular defect. There was strong alignment when comparing short-term recoverable module defects such as stuck trackers and offline strings to time series data. In general, we found that when an inverter block has more than 80% of modules flagged for one of these defects, its AC power time data is flat-lined and the inverter block is not producing.

aerial inspection↗

Unsupervised learning-enabled pulsed infrared thermographic microscopy of subsurface defects in stainless steel

Metallic structures produced with laser powder bed fusion (LPBF) additive manufacturing method (AM) frequently contain microscopic porosity defects, with typical approximate size distribution from one to 100 microns. Presence of such defects could lead to premature failure of the structure. In principle, structural integrity assessment of LPBF metals can be accomplished with nondestructive evaluation (NDE). Pulsed infrared thermography (PIT) is a non-contact, one-sided NDE method that allows for imaging of internal defects in arbitrary size and shape metallic structures using heat transfer. PIT imaging is performed using compact instrumentation consisting of a flash lamp for deposition of a heat pulse, and a fast frame infrared (IR) camera for measuring surface temperature transients. However, limitations of imaging resolution with PIT include blurring due to heat diffusion, sensitivity limit of the IR camera. We demonstrate enhancement of PIT imaging capability with unsupervised learning (UL), which enables PIT microscopy of subsurface defects in high strength corrosion resistant stainless steel 316 alloy. PIT images were processed with UL spatial–temporal separation-based clustering segmentation (STSCS) algorithm, refined by morphology image processing methods to enhance visibility of defects. The STSCS algorithm starts with wavelet decomposition to spatially de-noise thermograms, followed by UL principal component analysis (PCA), fine-tuning optimization, and neural learning-based independent component analysis (ICA) algorithms to temporally compress de-noised thermograms. The compressed thermograms were further processed with UL-based graph thresholding K-means clustering algorithm for defects segmentation. The STSCS algorithm also includes online learning feature for efficient re-training of the model with new data. For this study, metallic specimens with calibrated microscopic flat bottom hole defects, with diameters in the range from 203 to 76 µm, were produced using electro discharge machining (EDM) drilling. While the raw thermograms do not show any material defects, using STSCS algorithm to process PIT images reveals defects as small as 101 µm in diameter. To the best of our knowledge, this is the smallest reported size of a sub-surface defect in a metal imaged with PIT, which demonstrates the PIT capability of detecting defects in the size range relevant to quality control requirements of LPBF-printed high-strength metals.

36 MATERIALS SCIENCE↗