Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRON 61”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nuclear Data Sheets for A = 61

The evaluated spectroscopic data are presented for known nuclides of mass 61 (Sc,Ti,V,Cr,Mn,Fe,Co,Ni, Cu,Zn,Ga,Ge). Excited-state data are nonexistent for {sup 61}Sc, {sup 61}Ti, {sup 61}V, and {sup 61}Ge. Significant amounts of new data have been added since the previous NDS evaluation of A=61 nuclides (1999Bh04). {sup 61}Sc nuclide is now experimentally known, but without any knowledge of its half-life. The ground state half-lives of {sup 61}Ti and {sup 61}V are now determined. Excited-state data have become available for {sup 61}Cr, {sup 61}Mn and {sup 61}Ga, while for {sup 61}Ge, five excited states were erroneously assigned in the previous evaluation, these have been omitted here. Improved and extensive high-spin excitations are available for {sup 61}Fe, {sup 61}Cu and {sup 61}Zn, including several new superdeformed structures in {sup 61}Cu and {sup 61}Zn. Thermal neutron capture γ-ray data are available in detail from 2004Ra23. The radioactive decay schemes of {sup 61}Sc and {sup 61}Ti are not known, while those for {sup 61}V, {sup 61}Fe and {sup 61}Ge are poorly known. This work benefited from the earlier full evaluations of A=61 published by 1999Bh04, 1983Ek01 and 1975Au05 and the one published in an ‘update’ mode by 1992Zh31. The data and conclusions presented in the current work supersede those in all the previous evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Influence of pH on the balance between methanogenesis and iron reduction

Methanogenesis and iron reduction play major roles in determining global fluxes of greenhouse gases. Despite their importance, environmental factors that influence their interactions are poorly known. Here, we present evidence that pH significantly influences the balance between each reaction in anoxic environments that contain ferric (oxyhydr)oxide minerals. In sediment bioreactors that contained goethite as a source of ferric iron, both iron reduction and methanogenesis occurred but the balance between them varied significantly with pH. Compared to bioreactors receiving acidic media (pH 6), electron donor oxidation was 85% lower for iron reduction and 61% higher for methanogenesis in bioreactors receiving alkaline media (pH 7.5). Thus, methanogenesis displaced iron reduction considerably at alkaline pH. Geochemistry data collected from U.S. aquifers demonstrate that a similar pattern also exists on a broad spatial scale in natural settings. In contrast, in bioreactors that were not augmented with goethite, clay minerals served as the source of ferric iron and the balance between each reaction did not vary significantly with pH. We therefore conclude that pH can regulate the relative contributions of microbial iron reduction and methanogenesis to carbon fluxes from terrestrial environments. We further propose that the availability of ferric (oxyhydr)oxide minerals influences the extent to which the balance between each reaction is sensitive to pH. Here, the results of this study advance our understanding of environmental controls on microbial methane generation and provide a basis for using pH and the occurrence of ferric minerals to refine predictions of greenhouse gas fluxes.

58 GEOSCIENCES↗

Adsorptive recovery of neodymium and dysprosium in phosphorous functionalized nanoporous carbon

Here, phosphorus functionalized nanoporous carbon was synthesized from lignin by periodical reactions with potassium hydroxide and triphenylphosphine. It has the BET surface area of 837 m 2 /g and total pore volume 0.41 cm 3 /g along with 0.9 atom% phosphorus. The adsorption of neodymium (Nd (III)) and dysprosium (Dy(III)) were in the range of 335–344 mg/g upto their initial concentration of 500 ppm in water and such adsorption amount is higher than that of majority of the adsorbents reported in literature. The adsorption capacity showed negligible dependency on the solution pH. The distribution coefficients for Nd(III) and Dy(III) were within 1000 to 10,000 mL/g. The adsorption capacity of iron (Fe(III)) under the similar conditions was one order of magnitude lower and it suggests a possible separation of these rare earth elements from iron. The maximum selectivity of separation of Nd(III) and Dy(III) from iron was ca. 32 to 61. Kinetic study revealed that the adsorption of Dy was faster than that of Nd(III). The results of kinetic study were better fit with pseudosecond order kinetics. XPS studies on both Nd(III) and Dy(III)-adsorbed carbons revealed a small shift in the P 2p 3/2 energy level of phosphorus towards higher energy level hereby suggesting a possible formation of metallic phosphates. Additionally, Similar studies on Nd(III) and Dy(III)-adsorbed carbon indicated small amounts carbonates and oxides of rare earth elements that might have also been formed. In conculsion, the overall results suggest that this carbon can be used as a potential sorbent for enrichment and separation of Nd(III) and Dy(III).

36 MATERIALS SCIENCE↗

Uncertainties in secondary angular distributions and their impact on shielding, criticality and kinetics analysis - 25556

The availability of the covariance data improved over the last decades. Use of covariance matrices of different origin (such as JEFF, JENDL, ENDF, TENDL, SCALE, etc.) and types (files MF31, MF33, MF34, MF35) in sensitivity and uncertainty analysis of vast list of cases ranging from fission to fusion and from criticality, kinetics and shielding to adjustment applications was already studied in the past. The present work focuses on the status and the availability of the covariance of the angular distributions of scattered neutrons (secondary angular distributions - SAD covariances). SAD uncertainties are usually neglected in classical uncertainty propagation codes, even though the methods and codes for calculating the sensitivities are available for decades and excellent agreement was demonstrated between different deterministic and Monte Carlo codes. Of particular concern is still the availability, quality and completeness of covariance matrices. Indeed, in most evaluations the SAD covariances are limited to P1 term, if available at all. Furthermore, some differences were observed between different evaluations, e.g. in the case of iron. (author)

61 RADIATION PROTECTION AND DOSIMETRY↗

A new insight into neutrino energy loss by electron capture of iron group nuclei in magnetar surfaces

Based on the relativistic mean-field effective interactions theory, and the Lai dong model, we discuss the influences of superstrong magnetic fields (SMFs) on electron Fermi energy, nuclear blinding energy, and single-particle level structure in magnetar surfaces. Using the Shell-Model Monte Carlo method and the Random Phase Approximation theory, we analyze the neutrino energy loss rates (NELRs) by electron capture for iron group nuclei in SMFs. First, when B {sub 12} < 100, we find that the SMFs have a slight influence on the NELRs for most nuclides at relativistic low temperatures (e.g., T {sub 9} = 0.233); nevertheless, the NELRs increase by more than four orders of magnitude at relativistic high temperatures (e.g., T {sub 9} = 15.53). When B {sub 12} > 100, the NELRs decrease by more than three orders of magnitude (e.g., at T {sub 9} = 15.53 for {sup 52–61}Fe, {sup 55–60}Co, and {sup 56–63}Ni). Second, for a certain value of magnetic field and temperature, the NELRs increase by more than four orders of magnitude when ρ{sub 7}⩽10{sup 3}, but as the density increases (i.e., when ρ{sub 7}>10{sup 3}), there is almost no influence on the density of NELRs. For the density around ρ{sub 7}=10{sup 2}, there is an abrupt increase in NELRs when B {sub 12} ≥ 10{sup 3.5}. Such jumps are an indication that the underlying shell structure has changed due to single-particle behavior by SMFs. Finally, we compare our NELRs with those of Fuller et al. (FFN) and Nabi and Klapdor-Kleingrothaus (NKK). For the case without SMFs, one finds that our rates for certain nuclei are close to about five orders of magnitude lower than FFN and NKK at relativistic low temperatures (e.g., T {sub 9} = 1). However, at a relativistic high temperature (e.g., T {sub 9} = 3), our results are in good agreement with NKK, but about one order of magnitude lower than FFN. For the case with SMFs, our NELRs for some iron group nuclei can be about five orders of magnitude higher than those of FFN and NKK. (Note that B {sub 12}, T {sub 9}, and ρ {sub 7} are in units of 10{sup 12} G, 10{sup 9} K, and 10{sup 7} g cm{sup −3}, respectively.)

79 ASTRONOMY AND ASTROPHYSICS↗

Annotation of DOM metabolomes with an ultrahigh resolution mass spectrometry molecular formula library

Current approaches to analyzing metabolomic data often rely on matching MS/MS fragmentation data to sparse libraries or databases. This approach results in limited identification of features, often with less than 10% of the dataset being annotated. A complementary approach is to assign molecular formula to features based on accurate mass measurements, but the platforms commonly used for metabolomics do not have the needed accuracy or resolving power to do this robustly, particularly for larger molecules. Using our newly modified analysis tool, CoreMS, we generated a library of molecular formula from pooled samples analyzed with LC-21T FT-ICR MS. This library successfully annotated approximately 53.2% of features identified from the exometabolome of marine diatom Phaeodactylum tricornutum – a nearly ten-fold increase over the 5.9% annotation rate achieved using a conventional MS/MS library matching approach. Using this FT-ICR MS library approach, we were able to differentiate differences in the exometabolome of P. tricornutum in iron replete and iron limited conditions, with 668 metabolites being differentially expressed (p < 0.05, 2 x intensity difference) under these conditions. The traditional MS/MS fragmentation-based annotation approach only annotated 61 of these metabolites, while our novel pipeline annotated 450 metabolites and revealed 12 metabolites that were significantly more abundant under low iron conditions. Our results demonstrate the utility of ultrahigh resolution mass spectrometry for generating more comprehensive and confident molecular annotations.

21T-FTICR-MS, CoreMS↗

TH-CD-BRA-08: Novel Iron-Based Radiation Reporting Systems as 4D Dosimeters for MR-Guided Radiation Therapy

Purpose: To compare novel radiation reporting systems utilizing ferric ion (Fe{sup 3+}) reduction versus ferrous ion (Fe{sup 2+}) oxidation in gelatin matrixes for 3D and 4D (3D+time) MR-guided radiation therapy dosimetry. Methods: Dosimeters were irradiated using an integrated 1.5T MRI and 7MV linear accelerator (MR-Linac). Dosimeters were read-out with both a spectrophotometer and the MRI component of the MR-Linac immediately after irradiation. Changes in optical density (OD) were measured using a spectrophotometer; changes in MR signal intensity due to the paramagnetic differences in the iron ions were measured using the MR-Linac in real-time during irradiation (balanced-FFE sequences) and immediately after irradiation (T{sub 1}-weighted and inversion recovery sequences). Results: Irradiation of Fe{sup 3+} reduction dosimeters resulted in a stable red color with an absorbance peak at 512 nm. The change in OD relative to dose exhibited a linear response up to 100 Gy (R{sup 2}=1.00). T{sub 1}-weighted-MR signal intensity (SI) changed minimally after irradiation with increases of 8.0% for 17 Gy and 9.7% after escalation to 35 Gy compared to the un-irradiated region. Irradiation of Fe{sup 2+} oxidation dosimeters resulted in a stable purple color with absorbance peaks at 440 and 585 nm. The changes in OD, T{sub 1}-weighted-MR SI, and R{sub 1} relative to dose exhibited a linear response up to at least 8 Gy (R{sup 2}=1.00, 0.98, and 0.99) with OD saturation above 40 Gy. The T{sub 1}-weighted-MR SI increased 50.3% for 17 Gy compared to the un-irradiated region. The change in SI was observed in both 2D+time and 4D (3D+time) acquisitions post-irradiation and in real-time during irradiation with a linear increase with respect to dose (R{sup 2}>0.93). Conclusion: The Fe{sup 2+} oxidation-based system was superior as 4D dosimeters for MR-guided radiation therapy due to its higher sensitivity in both optical and MR signal readout and feasibility for real-time 4D dose readout. The Fe{sup 3+} reduction system is recommended for high dose applications. This material is based upon work supported by the National Science Foundation Graduate Research Fellowship Program under Grant No. LH-102SPS.

60 APPLIED LIFE SCIENCES↗

SU-F-T-671: Effects of Collimator Material On Proton Minibeams

Purpose: To investigate the dosimetric effects of collimator material on spatially modulated proton minibeams (pMBRT). Methods: pMBRT holds promise to exhibit shallow depth normal-tissue sparing effects similar to synchrotron based microbeams while also retaining potential for uniform dose distributions for tumor targets. TOPAS Monte Carlo simulations were performed for a 5cm thick multislit collimator with 0.3mm slits and 1mm center-to-center spacing for a 50.5MeV proton minibeam while varying collimator material between brass, tungsten, and iron. The collimator was placed both “flush” at the water phantom surface and at 5cm distance to investigate the effects on surface dose, peak-to-valley-dose-ratio (PVDR) and neutron contribution. Results: For flush placement, the neutron dose at the phantom surface for the tungsten collimator was approximately 20% higher than for brass and iron. This was not reflected in the overall surface dose, which was comparable for all materials due to the relatively low neutron contribution of <0.1%. When the collimator was retracted, the overall neutron contribution was essentially identical for all three collimators. Surface dose dropped by ∼40% for all collimator materials with air gap compared to being flush with the phantom surface. This surface dose reduction was at the cost of increase in valley dose for all collimator materials due to increased angular divergence of the mini-beams at the surface and their consequent geometric penumbra at depth. When the collimator was placed at distance from the phantom surface the PVDR decreased. The peak-to-entrance-dose ratio was highest for the iron collimator with 5cm air gap. Conclusion: The dosimetric difference between the collimator materials is minimal despite the relatively higher neutron contribution at the phantom surface for the tungsten collimator when placed flush. The air gap between the collimator and phantom surface strongly influences all dosimetry parameters due to the influence of scatter on the narrow spatial modulation.

60 APPLIED LIFE SCIENCES↗

Iron and nickel isotope compositions of presolar silicon carbide grains from supernovae

Here we report the carbon, silicon, iron, and nickel isotope compositions of twenty-five presolar SiC grains of mostly supernova (SN) origin. The iron and nickel isotope compositions were measured with the new Chicago Instrument for Laser Ionization, CHILI, which allows the analysis of all iron and nickel isotopes without the isobaric interferences that plagued previous measurements with the NanoSIMS. Despite terrestrial iron and nickel contamination, significant isotopic anomalies in 54 Fe/ 56 Fe, 57 Fe/ 56 Fe, 60 Ni/ 58 Ni, 61 Ni/ 58 Ni, 62 Ni/ 58 Ni, and 64 Ni/ 58 Ni were detected in nine SN grains (of type X). Combined multi-isotope data of three grains with the largest nickel isotope anomalies (>100% or <-100% in at least one isotope ratio, when expressed as deviation from the solar value) are compared with the predictions of two SN models, one with and one without hydrogen ingestion in the He shell prior to SN explosion. One grain's carbon-silicon-iron-nickel isotope composition is consistent with the prediction of the model without hydrogen ingestion, whereas the other two grains' isotope anomalies could not be reproduced using either SN models. The discrepancies between the measured isotope compositions and model predictions may indicate element fractionation in the SN ejecta prior to or during grain condensation, and reiterate the need for three-dimensional SN models.

79 ASTRONOMY AND ASTROPHYSICS↗

Feasibility study for detection of fuel assemblies state inside sealed dry storage casks using external gamma flux measurements - 25445

The license for the storage of spent nuclear fuel assemblies in dry casks is limited to 40 years. In Germany, a site for a final repository of spent fuel is not yet available. Therefore, this license has to be renewed for prolonged storage period. Currently, there is no experience with dry cask storage worldwide that goes beyond a period of 40 years. Beside regulatory and security aspects, there are questions concerning the long-term integrity of the spent fuel assemblies as this is of relevance for final transportation and reloading to final waste repository casks. Once the cask is filled and sealed, the knowledge about the state of the fuel assemblies is limited. This study investigates the feasibility of using external gamma flux measurements to detect the state of the spent fuel assemblies inside the cask. Monte-Carlo simulations were performed to evaluate the gamma flux distribution outside the sidewall of a cask with all intact fuel assemblies and a cask with one damaged fuel assembly, mimicking a fuel assembly with expanded rods and fuel relocation. The evaluation was performed for different location of the damaged fuel assembly and different storage times. The results of the investigation showed that the intensity and the shape of the gamma flux outside the sidewall of the cask are sufficient to identify the damaged fuel assembly, in case it is located near the inner wall of the cask. The detection of the inner damaged fuel assemblies, however, is less feasible. Due to the self-shielding of the fuel assemblies, the gamma photons which come from the inner fuel assemblies stopped within the fuel basket and assemblies materials. The gamma photons which do survive the fuel assemblies self-shielding reach the inner cask wall with not enough energy to escape the shielding of the thick cast iron wall. In general, it can be concluded that the more the damaged fuel assembly is close to the cask inner walls and that the damage is in a large scale (i.e., significant fuel relocation), the more it can be detected by external gamma flux measurements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Activation in injection area of J-PARC 3-GeV rapid cycling synchrotron and its countermeasures - 25344

The 3-GeV rapid cycling synchrotron in Japan Proton Accelerator Research Complex aims to deliver a 1-MW proton beam to the neutron target and the main ring synchrotron. The existing beam power of the Rapid Cycling Synchrotron is up to 500 kW, and higher radiation doses are concentrated in the injection area. These activations are caused by the interaction between the foil and the beam. To reduce dose exposure to workers near the injection point, we study a new design of the injection scheme to secure sufficient space for radiation shielding and bellows. Experience has shown that eddy currents are generated in the metal flange near the magnet owing to the effect of the pulsed magnetic field used for injection, and the temperature exceeds 100 deg. C. The shield installed in the new injection system needs to have a layer structure, in which an insulator is inserted between iron shields to reduce the eddy current. From the results of the shielding calculation, even if 1 mm of polyethylene was inserted between two 9-mm-thick SUS 316 plates, which serve as shielding material, the shielding performance was reduced only about 5%, and we confirmed that it would function well. (authors)

43 PARTICLE ACCELERATORS↗

SU-F-T-361: Dose Enhancement Due to Nanoparticle Addition in Skin Radiotherapy: A Monte Carlo Study Using Kilovoltage Photon Beams

Purpose: This study investigated the dose enhancement due to addition of nanoparticles with different types and concentrations in skin radiotherapy using kilovoltage photon beams. Methods: An inhomogeneous water phantom (15×15×10 cm{sup 3}) having the skin target layer (0.5–5 mm), added with different concentrations (3–40 mg/ml) of nanoparticles (Au, Pt, I, Ag and Fe{sub 2}O{sub 3}), was irradiated by the 105 and 220 kVp photon beams produced by a Gulmay D3225 Orthovoltage unit. The circular cone of 5-cm diameter and source-to-surface distance of 20 cm were used. Doses in the skin target layer with and without adding the nanoparticles were calculated using Monte Carlo simulation (the EGSnrc code) through the macroscopic approach. Dose enhancement ratio (DER), defined as the ratio of dose at the target with nanoparticle addition to the dose without addition, was calculated for each type and concentration of nanoparticle in different target thickness. Results: For Au nanoparticle, DER dependence on target thickness for the 220 kVp photon beams was not significant. However, DER for Au nanoparticle was found decreasing with an increase of target thickness when the nanoparticle concentration was increased from 18 to 40 mg/ml using the 105 kVp photon beams. For nanoparticle concentration of 40 mg/ml, DER variation with target thickness was not significant for the 220 kVp photon beams, but DEF was found decreasing with the target thickness when lower energy of photon beam (105 kVp) was used. DEF was found increasing with an increase of nanoparticle concentration. The higher the DEF increasing rate, the higher the atomic number of the nanoparticle except I and Ag for the same target thickness. Conclusion: It is concluded that nanoparticle addition can result in dose enhancement in kilovoltage skin radiotherapy. Moreover, the DER is related to the photon beam energy, target thickness, atomic number and concentration of nanoparticles.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-04: Comparison Between Fricke-Type 3D Radiochromic Dosimeters for Real-Time Dose Distribution Measurements in MR-Guided Radiation Therapy

Purpose: To assess MR signal contrast for different ferrous ion compounds used in Fricke-type gel dosimeters for real-time dose measurements for MR-guided radiation therapy applications. Methods: Fricke-type gel dosimeters were prepared in 4% w/w gelatin prior to irradiation in an integrated 1.5 T MRI and 7 MV linear accelerator system (MR-Linac). 4 different ferrous ion (Fe2?) compounds (referred to as A, B, C, and D) were investigated for this study. Dosimeter D consisted of ferrous ammonium sulfate (FAS), which is conventionally used for Fricke dosimeters. Approximately half of each cylindrical dosimeter (45 mm diameter, 80 mm length) was irradiated to ∼17 Gy. MR imaging during irradiation was performed with the MR-Linac using a balanced-FFE sequence of TR/TE = 5/2.4 ms. An approximate uncertainty of 5% in our dose delivery was anticipated since the MR-Linac had not yet been fully commissioned. Results: The signal intensities (SI) increased between the un-irradiated and irradiated regions by approximately 8.6%, 4.4%, 3.2%, and 4.3% after delivery of ∼2.8 Gy for dosimeters A, B, C, and D, respectively. After delivery of ∼17 Gy, the SI had increased by 24.4%, 21.0%, 3.1%, and 22.2% compared to the un-irradiated regions. The increase in SI with respect to dose was linear for dosimeters A, B, and D with slopes of 0.0164, 0.0251, and 0.0236 Gy{sup −1} (R{sup 2} = 0.92, 0.97, and 0.96), respectively. Visually, dosimeter A had the greatest optical contrast from yellow to purple in the irradiated region. Conclusion: This study demonstrated the feasibility of using Fricke-type dosimeters for real-time dose measurements with the greatest optical and MR contrast for dosimeter A. We also demonstrated the need to investigate Fe{sup 2+} compounds beyond the conventionally utilized FAS compound in order to improve the MR signal contrast in 3D dosimeters used for MR-guided radiation therapy. This material is based upon work supported by the National Science Foundation Graduate Research Fellowship Program under Grant No. LH- 102SPS.

60 APPLIED LIFE SCIENCES↗

Monte Carlo estimates of sensitivities to geometric perturbations for shielding problems using kernel density estimators - 25605

A Monte Carlo method to estimate the sensitivity of reaction rates like dose and flux spectra to geometric perturbations using kernel density estimators is demonstrated for shielding problems. The method is used to estimate the sensitivity of the spectrum emitted from a Cf-252 source at the center of an iron sphere as well as the sensitivity of the dose due to Cf-252 neutrons shielded using various materials. Results are compared against reference solutions obtained using Monte Carlo direct perturbations with central differences, with agreement within 5% and 3σ for the majority of results. The results indicate that a bandwidth that is 10-20% of the shielding thickness produces accurate results with statistically insignificant bias for the chosen test problems. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Strategies for the Photoreduction of Tc-99 Pertechnetate to Low-Valent Tc by Keggin Polyoxometalates

Technetium-99 (half-life of 2.1 × 10 5 yrs, β max = 0.29 MeV) is a hazardous radiological contaminant, which, in its predominant form of pertechnetate (TcO 4 – ), is highly mobile in the environment. Most strategies for the removal of pertechnetate from the environment involve uptake and/or absorption of pertechnetate using resins, clays, cationic metal-organic frameworks and even thorium borate ceramic like materials. Alternative approaches have involved the reduction and subsequent sequestration of lower valent technetium species using iron, sulfides, or iron sulfides. Here, our lab has explored this strategy using the lacunary alpha-2 Wells–Dawson polyoxometalate (α 2 -[P 2 W 17 O 61 ] 10– ) to both reduce and sequester lower valent technetium, and we have reported on the ligand features that stabilize the reduced species. In this work we investigate the potential of “plenary” Keggin POMs (XW 12 O 40 n – ) (X = P, Si, Al, n = 3, 4, 5, respectively) to both reduce TcO 4 – and stabilize the reduced Tc species. Specifically, we report on the mechanism by which the reduction of technetium occurs and find that PW 12 , SiW 12 , and AlW 12 promote the reduction of TcO 4 – to lower valent states. X-ray absorption spectroscopy was used to confirm a combination of Tc IV {in the form of TcO 2 · 2H 2 O and Tc 2 (µ-O) 2 4+ } and Tc V , which is subsequently complexed into a POM defect as a Tc V =O species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of nuclear data based on the ASPIS experiments from the SINBAD database - 25428

SINBAD, the Shielding Integral Benchmark Archive and Database, includes the experimental data relative to integral benchmark experiments relevant for radiation shielding applications. The ASPIS experiments, included in the Reactor Shielding section of SINBAD, provide neutron activation foils and spectra measurements performed before/between shielding slabs of Graphite, Sodium, Iron, Steels, Water and combinations of them. Benchmark models for the measurement simulations with the MCNP code are usually provided in SINBAD. Nonetheless, a user-friendly tool is presented, which would be useful for an independent production of MCNP benchmark models. It is based on GPL C++ code called CombLayer. The reports issued for SINBAD on the quality assessment of the ASPIS experiments are also described. The discussion on the quality of the ASPIS experiments for their use in nuclear data evaluations had a positive outcome, except for two experiments out of ten. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-207-07: Dual-Energy Computed Tomography Detection Limit of Various Radiopaque Contrast Agents That Can Be Infused Within Absorbable Inferior Vena Cava Filters

Purpose: Absorbable IVC filters are shown to be safe and efficacious in preventing pulmonary embolism. These absorbable filters disappear from the body after their required duration, alleviating costly removal procedures and downstream complications. Monitoring the positioning and integrity of absorbable devices using dual-energy computed tomography (DECT) would improve treatment efficacy. The purpose of this study is to determine the limit of detection and the energy dependence of DECT for various contrast agents that may be infused within the IVC filters including gold nanoparticles (AuNP) having diameters of 2 and 4 nm. Methods: All imaging studies were performed on a GE Discovery CT750 system in Gemstone Spectral Imaging (GSI) mode. Plastic vials containing the contrast agent solutions of water and blood were placed in a water bath, and images were acquired with the GSI-5 preset. The images were reformatted into the coronal plane and 5mm diameter ROIs were placed within each solution on a GE Advantage Workstation. Monoenergetic reconstructions were generated from 40 – 140 keV. Results: Mass attenuation (contrast per unit density) for AuNPs was greater than iron, but less than barium and iodine. Contrast was 10.2 (± 3.6) HU for 4 nm AuNP at 0.72 mg/ml and 12.1 (± 4.2) for 2 nm AuNP at 0.31 mg/ml at 70 keV suggesting reasonable chance of visualization at these concentrations for 70 keV reconstruction. The contrast as a function of CT energy is similar in both water and blood. Iodine is most dependent, followed closely by barium and iron, and trailed by a large margin by the AuNP. This was unexpected given Au’s large atomic number and the predominance of photoelectric effect at low energy. Conclusion: Infusion of IVC filters with AuNP is feasible. Discrimination of AuNP-infused IVC filters from surrounding anatomy warrants further investigation.

60 APPLIED LIFE SCIENCES↗