Search NASA⌕ Search

SEARCH · Search NASA

Results for “ISOCHRONOUS CYCLOTRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Oak Ridge Isochronous Cyclotron Refurbishment Project

The Oak Ridge Isochronous Cyclotron (ORIC) has been in operation for nearly fifty years at the Oak Ridge National Laboratory (ORNL). Presently, it serves as the driver accelerator for the ORNL Holifield Radioactive Ion Beam Facility (HRIBF), where radioactive ion beams are produced using the Isotope Separation Online (ISOL) technique for post-acceleration by the 25URC tandem electrostatic accelerator. Operability and reliability of ORIC are critical issues for the success of HRIBF and have presented increasingly difficult operational challenges for the facility in recent years. In February 2010, a trim coil failure rendered ORIC inoperable for several months. This presented HRIBF with the opportunity to undertake various repairs and maintenance upgrades aimed at restoring the full functionality of ORIC and improving the reliability to a level better than what had been typical over the previous decade. In this paper, we present details of these efforts, including the replacement of the entire trim coil set and measurements of their radial field profile. Comparison of measurements and operating tune parameters with setup code predictions will also be presented.

Ball, James B↗

Computer modeling of a compact isochronous cyclotron

The computer modeling methods of a compact isochronous cyclotron are described. The main stages of analysis of accelerator facilities systems are considered. The described methods are based on theoretical fundamentals of cyclotron physics and mention highlights of creation of the physical project of a compact cyclotron. The main attention is paid to the analysis of the beam dynamics, formation of a magnetic field, stability of the movement, and a realistic assessment of intensity of the generated bunch of particles. In the article, the stages of development of the accelerator computer model, analytical ways of assessment of the accelerator parameters, and the basic technique of the numerical analysis of dynamics of the particles are described.

43 PARTICLE ACCELERATORS↗

Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons

In an isochronous cyclotron, measurements of central phase of the ion beam with respect to rf and the phase width provide a way to tune the cyclotron for maximum energy gain per turn and efficient extraction. We report here the development of a phase measurement system and the measurements carried out at the Variable Energy Cyclotron Centre's (VECC's) K= 500 superconducting cyclotron. The technique comprises detecting prompt {gamma}-rays resulting from the interaction of cyclotron ion beam with an aluminium target mounted on a radial probe in coincidence with cyclotron rf. An assembly comprising a fast scintillator and a liquid light-guide inserted inside the cyclotron was used to detect the {gamma}-rays and to transfer the light signal outside the cyclotron where a matching photo-multiplier tube was used for light to electrical signal conversion. The typical beam intensity for this measurement was a few times 10{sup 11} pps.

43 PARTICLE ACCELERATORS↗

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN↗

Nuclear Data Sheets for A = 87

The evaluated experimental data are presented for 14 known nuclides of mass 87 (Ga, Ge, As, Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo, Tc, Ru). New datasets have been added for {sup 87}Ga, {sup 87}Se, {sup 87}Kr, {sup 87}Rb, {sup 87}Sr, {sup 87}Nb, and {sup 87}Tc. The observation of and new lifetime measurements for {sup 87}As at the NSCL Coupled Cyclotron Facility and the Oak Ridge Isochronous Cyclotron at the HRIBF–ORNL Facility are included in the adopted levels for this isotope. The new evaluation also includes an isomeric level at unknown energy for {sup 87}Tc, changes to the adopted levels for {sup 87}Nb based on newly published data including an extension of the high spin levels and new lifetime measurements, and new heavy ion data for {sup 87}Kr. New high spin levels for {sup 87}Rb were observed, indicating possible neutron core excitations. In addition, the ground state lifetime of {sup 87}Rb has been revised and a new lifetime measurement for an excited level in {sup 87}Rb indicates a possible proton spin flip. New excitation levels have been observed for the first time in {sup 87}Se. New direct and precise measurement of atomic masses of {sup 87}Tc, {sup 87}Mo, {sup 87}Nb, {sup 87}Zr, {sup 87}Mo and {sup 87}Tc have greatly improved the Q value landscape in this mass region. This work supersedes the previous A=87 evaluation published in 2002He09, and Q values for all isotopes were updated to incorporate the mass evaluation in 2012Wa38.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental observation of acoustic emissions generated by a pulsed proton beam from a hospital-based clinical cyclotron

Purpose: To measure the acoustic signal generated by a pulsed proton spill from a hospital-based clinical cyclotron. Methods: An electronic function generator modulated the IBA C230 isochronous cyclotron to create a pulsed proton beam. The acoustic emissions generated by the proton beam were measured in water using a hydrophone. The acoustic measurements were repeated with increasing proton current and increasing distance between detector and beam. Results: The cyclotron generated proton spills with rise times of 18 μs and a maximum measured instantaneous proton current of 790 nA. Acoustic emissions generated by the proton energy deposition were measured to be on the order of mPa. The origin of the acoustic wave was identified as the proton beam based on the correlation between acoustic emission arrival time and distance between the hydrophone and proton beam. The acoustic frequency spectrum peaked at 10 kHz, and the acoustic pressure amplitude increased monotonically with increasing proton current. Conclusions: The authors report the first observation of acoustic emissions generated by a proton beam from a hospital-based clinical cyclotron. When modulated by an electronic function generator, the cyclotron is capable of creating proton spills with fast rise times (18 μs) and high instantaneous currents (790 nA). Measurements of the proton-generated acoustic emissions in a clinical setting may provide a method for in vivo proton range verification and patient monitoring.

60 APPLIED LIFE SCIENCES↗

Commercial cyclotrons. Part I: Commercial cyclotrons in the energy range 10–30 MeV for isotope production

A survey of commercial cyclotrons for production of medical and industrial isotopes is presented. Compact isochronous cyclotrons which accelerate negative hydrogen ions in the energy range 10–30 MeV have been widely used over the last 25 years for production of medical isotopes and other applications. Different cyclotron models for the energy range 10–12 MeV with moderate beam intensity are used for production of {sup 11}C, {sup 13}N, {sup 15}O, and {sup 18}F isotopes widely applied in positron emission tomography. Commercial cyclotrons with high beam intensity are available on the market for production of most medical and industrial isotopes. In this work, the physical and technical parameters of different models are compared. Possibilities of improving performance and increasing intensity of H{sup −} beams up to 2–3 mA are discussed.

43 PARTICLE ACCELERATORS↗

Analytic model for the breakup of a coasting beam with space charge in isochronous accelerators

An analytical model based on the negative mass instability is introduced in this paper to explain the formation of the breakup of a coasting beam into small clusters in isochronous machines such as the case observed by Pozdeyev and Rodriguez in a small isochronous ring. Solving Poisson's equation in both charge and vacuum regions with the longitudinal beam density perturbation, the coherent radial space charge force which decreases the transition gamma is obtained. It is found that the modified transition gamma depends on the wave number of the density perturbation, longitudinal beam density distribution, beam intensity, and beam size. By combining the longitudinal space charge force caused by the perturbation and the modified transition gamma, a dispersion relation for a monoenergetic beam is derived and evaluated for the fastest-growing instability mode in terms of the beam parameters, such as energy, bunch length, intensity, and emittance. The fastest-growing negative mass mode number, which determines not only the cluster number but also the growth rate of the instability, is proportional to the orbit radius and inversely proportional to the initial beam size. With the growth of the instability, the particles at the points of local minimum density move to the ones of local maximum density, with the transition gamma increasing. Since the growth rate depends on the longitudinal density distribution, therefore, instead of a constant growth rate, our model shows that the growth rate decreases with time. The results above can be applied to both short and long wavelength limits. As an important application of this theory, the beam breakup effect in the isochronous cyclotron CYCIAE-100 is predicted.

43 PARTICLE ACCELERATORS↗

A room temperature electron cyclotron resonance ion source for the DC-110 cyclotron

The project of the DC-110 cyclotron facility to provide applied research in the nanotechnologies (track pore membranes, surface modification of materials, etc.) has been designed by the Flerov Laboratory of Nuclear Reactions of the Joint Institute for Nuclear Research (Dubna). The facility includes the isochronous cyclotron DC-110 for accelerating the intensive Ar, Kr, Xe ion beams with 2.5 MeV/nucleon fixed energy. The cyclotron is equipped with system of axial injection and ECR ion source DECRIS-5, operating at the frequency of 18 GHz. This article reviews the design and construction of DECRIS-5 ion source along with some initial commissioning results.

43 PARTICLE ACCELERATORS↗

Radioactive Ion Beam Production Capabilities At The Holifield Radioactive Ion Beam Facility

The Holifield Radioactive Ion Beam Facility (HRIBF) is a national user facility for research with radioactive ion beams (RIBs) that has been in routine operation since 1996. It is located at Oak Ridge National Laboratory (ORNL) and operated by the ORNL Physics Division. The principal mission of the HRIBF is the production of high quality beams of shortlived radioactive isotopes to support research in nuclear structure physics and nuclear astrophysics. HRIBF is currently unique worldwide in its ability to provide neutron-rich fission fragment beams post-accelerated to energies above the Coulomb barrier for nuclear reactions. HRIBF produces RIBs by the isotope separator on-line (ISOL) technique using a particle accelerator system that consists of the Oak Ridge Isochronous Cyclotron (ORIC) driver accelerator, one of the two Injectors for Radioactive Ion Species (IRIS1 or IRIS2) production systems, and the 25-MV tandem electrostatic accelerator that is used for RIB post-acceleration. ORIC provides a light ion beam (proton, deuteron, or alpha) which is directed onto a thick target mounted in a target-ion source (TIS) assembly located on IRIS1 or IRIS2. Radioactive atoms that diffuse from the target material are ionized, accelerated, mass selected, and transported to the tandem accelerator where they are further accelerated to energies suitable for nuclear physics research. RIBs are transported through a beam line system to various experimental end stations including the Recoil Mass Spectrometer (RMS) for nuclear structure research, and the Daresbury Recoil Separator (DRS) for nuclear astrophysics research. HRIBF also includes two off-line ion source test facilities, one low-power on-line ISOL test facility (OLTF), and one high-power on-line ISOL test facility (HPTL). This paper provides an overview and status update of HRIBF, describes the recently completed $4.7M IRIS2 addition and incorporation of laser systems for beam production and purification, and discusses a proposed replacement of the ORIC driver accelerator.

43 PARTICLE ACCELERATORS↗

Modern compact accelerators of cyclotron type for medical applications

Ion beam therapy and hadron therapy are types of external beam radiotherapy. Recently, the vast majority of patients have been treated with protons and carbon ions. Typically, the types of accelerators used for therapy were cyclotrons and synchrocyclotrons. It is intuitively clear that a compact facility fits best to a hospital environment intended for particle therapy and medical diagnostics. Another criterion for selection of accelerators to be mentioned in this article is application of superconducting technology to the magnetic system design of the facility. Compact isochronous cyclotrons, which accelerate protons in the energy range 9–30 MeV, have been widely used for production of radionuclides. Energy of 230 MeV has become canonical for all proton therapy accelerators. Similar application of a carbon beam requires ion energy of 430 MeV/u. Due to application of superconducting coils the magnetic field in these machines can reach 4–5 T and even 9 T in some cases. Medical cyclotrons with an ironless or nearly ironless magnetic system that have a number of advantages over the classical accelerators are in the development stage. In this work an attempt is made to describe some conceptual and technical features of modern accelerators under consideration. The emphasis is placed on the magnetic and acceleration systems along with the beam extraction unit, which are very important from the point of view of the facility compactness and compliance with the strict medical requirements.

43 PARTICLE ACCELERATORS↗

Holifield Radioactive Ion Beam Facility Status

The Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory (ORNL) produces high-quality beams of short-lived radioactive isotopes for nuclear science research, and is currently unique worldwide in the ability to provide neutron-rich fission fragment beams post-accelerated to energies above the Coulomb barrier. HRIBF is undergoing a multi-phase upgrade. Phase I (completed 2005) was construction of the High Power Target Laboratory to provide the on-going Isotope Separator On-Line (ISOL) development program with a venue for testing new targets, ion sources, and radioactive ion beam (RIB) production techniques with high-power beams. Phase II, which is on schedule for completion in September 2009, is the Injector for Radioactive Ion Species 2 (IRIS2), a second RIB production station that will improve facility reliability and accommodate new ion sources, new RIB production targets, and some innovative RIB purification techniques, including laser applications. The Phase III goal is to substantially improve facility performance by replacing or supplementing the Oak Ridge Isochronous Cyclotron (ORIC) production accelerator with either a high-power 25-50 MeV electron accelerator or a high-current multi-beam commercial cyclotron. Either upgrade is applicable to R&D on isotope production for medical or other applications.

43 PARTICLE ACCELERATORS↗

ISOL science at the Holifield Radioactive Ion Beam Facility

The Holi eld Radioactive Ion Beam Facility, located in Oak Ridge, Tennessee, is operated as a National User Facility for the U.S. Department of Energy, producing high quality ISOL beams of short-lived, radioactive nuclei for studies of exotic nuclei, astrophysics research, and various societal applications. The primary driver, the Oak Ridge Isochronous Cyclotron, produces rare isotopes by bombarding highly refractory targets with light ions. The radioactive isotopes are ionized, formed into a beam, mass selected, injected into the 25-MV Tandem, accelerated, and used in experiments. This article reviews HRIBF and its science.

43 PARTICLE ACCELERATORS↗

Comparison of accelerator technologies for use in ADSS

Accelerator Driven Subcritical (ADS) fission is an interesting candidate basis for nuclear waste transmutation and for nuclear power generation. ADS can use either thorium or depleted uranium as fuel, operate below criticality, and consume rather than produce long-lived actinides. A case study with a hypothetical, but realistic nuclear core configuration is used to evaluate the performance requirements of the driver proton accelerator in terms of beam energy, beam current, duty factor, beam distribution delivered to the fission core, reliability, and capital and operating cost. Comparison between a CW IC and that of a SRF proton linac is evaluated. Future accelerator R&D required to improve each candidate accelerator design is discussed. ADS fission has interesting potential for electric power generation and also for destruction of long-lived actinide waste produced by conventional critical reactors. ADS systems offer several interesting advantages in comparison to critical reactors: (1) ADS provides greater flexibility for the composition and placement of fissile, fertile, or fission product waste within the core, and require less enrichment of fissile content; (2) The core can be operated with a reactivity k{sub eff} that cannot reach criticality by any failure mode; (3) When the beam is shut off fission ceases in the core; (4) Coupling the fast neutron spectrum of the spallation drive to fast core neutronics offers a basis for more complete burning of long-lived actinides; and (5) ADS designs can provide sufficient thermal mass that meltdown cannot occur from radioactive heat after fission is stopped. In order to drive a {approx}GW{sub e} fission core a CW proton beam of >700 MeV and {approx}15 MW beam power is required. A previous study of the accelerator performance required for ADS systems concluded that present accelerator performance is approaching those requirements, but accelerator system cost and reliability remain particular concerns. The obvious candidates for accelerators that can provide intense CW proton beams are isochronous cyclotrons (IC) and superconducting linacs. We have examined a case study using a hypothetical ADS core configuration to guide our thinking in evaluating those two accelerator technologies for use in ADS systems. Issues of accelerator power, multiplicity of accelerators, and options for core neutronics and fuel form are discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of the MCNP6 and FLUKA Codes in Shielding Calculation at ProNova Proton Therapy Facility

The Monte Carlo method is a powerful tool to simulate particle transport in materials, and can be effectively used to design radiation shielding. The purpose of this study is to compare the results from two Monte Carlo codes (MCNP6 and FLUKA ) in shielding design. The calculation was also compared with the measured results from the ProNova Superconducting 360 degrees (SC360) installation at the Knoxville Provision Center for Proton Therapy (PCPT) facility. The SC360 230 MeV continue wave (CW) proton beam is produced by an isochronous cyclotron, the Sumitomo P235. The maximum beam that is extracted into the beamline is 300 nA, which is of 60% of the full current generated in cyclotron. The SC360 facility has an energy selection system for adjusting the proton range, one fixed beam and one gantry room for rotating the beam around the stationary patient. At the entrance to each treatment room beamline, a thickness adjustable Beryllium degrader inserted in the beam path is used to achieve the desirable beam energy. When protons interact with beamline components, the secondary neutrons become the dominant source to determine the radiation shielding. In this study, the dose rate outside the lateral wall of the beamline vault was discussed. The calculations from two Monte Carlo codes were compared and they agreed very well. The dose rates measured by a Wendi-II Neutron Detector agreed within a factor of less than seven compared with the calculation results. The difference may be explained by a variety of factors such as the uncertainty in knowing the exact composition of shielding materials, geometry difference, and the measurement uncertainty due to instrumentation. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of Proton Energy Deposition from Monte Carlo Simulations and Measurement Results

ProNova's mission is to deliver a lower-cost, smaller, lighter and more energy efficient solution for Proton Therapy without sacrificing performance and improving upon existing capabilities. A high current, isochronous cyclotron (Sumitomo P235) is used as the mono-energetic 230 MeV proton beam source for the ProNova SC360 Proton Therapy System installation at the Knoxville Provision Center for Proton Therapy (PCPT). The energy of the proton beam ranges from 70 MeV to 230 MeV in the treatment room by adjusting the thickness of a Beryllium degrader installed at the Energy Section Beamline (ESB) for each treatment room. In order to better characterize the proton energy loss in the treatment volume, the proton energy deposition in a water phantom located at the treatment position is analyzed in this study, including Monte Carlo simulation and experimental measurements for different energies. It is concluded that Monte Carlo simulations give a good prediction of proton energy deposition. The results also confirmed that at increasing beam energy, protons will have broader FWHM and decreased peak-to-entrance dose ratio. The ProNova SC360 design results in an energy spread that does not change linearly with the energy due to the unique degrader and ESB design. Monte Carlo simulation results match proton beam measurement well. The Monte Carlo simulation results, validated by measurement, will be used as proton beam data for Treatment Planning System commissioning. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiochromic EBT2 film dosimetry for low-energy protontherapy

Purpose: In protontherapy, accessories are used in order to adapt the beam to the surface and to the depth of the target. They are positioned close to the patient in order to avoid perturbation effects related to proton scattering. The level of contamination of the beam caused by these accessories may be assessed by examining the dose maps in parallel planes to the beam incidence. The EBT2 radiochromic film is a suitable tool for this task, as it can be cut into small pieces and immersed in water. Prior to use the EBT2 film for dose measurements, its response when exposed to a proton beam must be analysed. Methods: The measurements were performed at the Centre Antoine Lacassagne, using the hospital-based MEDICYC isochronous cyclotron which provides 65 MeV protons. Monoenergetic as well as polyenergetic beams were used. Small pieces of EBT2 films were irradiated with proton beams in a small water phantom. Films were exposed at various angles close to the beam incidence and received doses ranging from 0.25 to 500 Gy. The optical density (OD) was studied as a function of angle, dose and linear energy transfer (LET). Results: The effective atomic number of the active layer of the film is close to that of water which prevents disturbances of the measurement. However, the high density and the significant thickness of the Mylar substrate surrounding the active layer affect the use of the film in a parallel orientation to the beam. Therefore, the substrate layer may totally or partially slow down the protons. The measurement is then no longer representative to what happens in water. The measurement errors can be corrected by applying a tilt angle of at least 5 deg. between the film and the beam. The dose analysis reveals that the green channel is the most sensitive in the dose range from 1 to 100 Gy. The OD is accurately described by a Weibull function of the dose with four free parameters. The Weibull function is valid for both monoenergetic and polyenergetic beams if the LET is limited to values below 15 MeV g{sup -1} cm{sup 2}. When using a film orientation close to the beam incidence angle, increasing LET values are encountered throughout the film axis gradually with the protons slowing down in water. The EBT2 films show an underestimated response for higher LET values. The comparison of data from the present study to data obtained by other authors for EBT films allows modelling the underestimated response as a function of the LET. The definition improvement of the link between OD and LET requires to integrate more closely the beam energy characteristics. Conclusions: The EBT2 film is a suitable dosimeter for analysing dose plans in planes nearly parallel to the beam orientation by compensating the underestimated dose response due to LET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cyclotrons and FFAG Accelerators as Drivers for ADS

Our review summarizes projects and studies on circular accelerators proposed for driving subcritical reactors. The early isochronous cyclotron cascades, proposed about 20 years ago, and the evolution of these layouts up to the most recent solutions or designs based on cyclotrons and fixed field alternating gradient accelerators, are reported. Additionally, the newest ideas and their prospects for development are discussed.

43 PARTICLE ACCELERATORS↗