Search NASA⌕ Search

SEARCH · Search NASA

Results for “ISOTOPE APPLICATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improvements in RIMS Isotopic Precision: Application to in situ atom-limited analyses

Resonance ionization mass spectrometry offers high sensitivity and elemental selectivity in microanalysis, but the isotopic precision attainable by this technique has been limited. Here we report instrumental modifications to improve the precision of RIMS isotope ratio measurements. Special attention must be paid to eliminating pulse-to-pulse variations in the time-of-flight mass spectrometer through which the photoions travel, and resonant excitation schemes must be chosen such that the resonance transitions can substantially power-broadened to cover the isotope shifts. We report resonance ionization measurements of chromium isotope ratios with statistics-limited precision better than 1%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rate equation model of laser induced bias in uranium isotope ratios measured by resonance ionization mass spectrometry

Resonance Ionization Mass Spectrometry (RIMS) has been developed as a method to measure uranium isotope abundances. In this approach, RIMS is used as an element-selective ionization process between uranium atoms and potential isobars without the aid of chemical purification and separation. The use of broad bandwidth lasers with automated feedback control of wavelength was applied to the measurement of the U-235/U-238 ratio to decrease laser-induced isotopic fractionation. In application, isotope standards are used to identify and correct bias in measured isotope ratios, but understanding laser-induced bias from first-principles can improve the precision and accuracy of experimental measurements. A rate equation model for predicting the relative ionization probability has been developed to study the effect of variations in laser parameters on the measured isotope ratio. The model uses atomic data and empirical descriptions of laser performance to estimate the laser-induced bias expected in experimental measurements of the U-235/U-238 ratio. Empirical corrections are also included to account for ionization processes that are difficult to calculate from first principles with the available atomic data. Development of this model has highlighted several important considerations for properly interpreting experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing secondary neutrons at BLIP for isotope production applications

Fast secondary neutrons created at the Brookhaven Linac Isotope Producer (BLIP) facility following proton irradiation were characterized by the foil activation technique and compared with FLUKA Monte Carlo simulations. The FLUKA-simulated neutron flux was spectrally adjusted following the maximum entropy formalism using the International Reactor Dosimetry and Fusion File (IRDFF-II), with predictions agreeing with experimental measurements to within 9 % following the adjustment procedure. Here, a multitude of degrader configurations were simulated to assess the feasibility of improving the fast (E n > 20 MeV) secondary neutron yield at the proposed neutron target position (“N-slot”). A configuration where the N-slot is closest to the proton degrader produced the highest fast neutron yield, with tungsten degraders achieving the best performance. Assuming the optimized target-degrader configuration proposed in this work, we discuss potential isotope production opportunities with secondary neutrons. In most cases the yields are in the order of several mCi.

07 ISOTOPE AND RADIATION SOURCES↗

Isotopes and Applications Working Group: Report update October 2013

No significant changes are proposed for the scientific program. The standard mode of operation at FRIB will be to produce a rare isotope beam for a primary user, for example 60 Ca from a 82 Se beam. At the same time, the fragmentation or fission of the production beam will produce up to 1000 other isotopes that could be collected (harvested) and used for other experiments or applications. The potential applications of these harvested isotopes range from the determination of neutron cross sections for homeland security to kinetic studies of radionuclide uptake in biological processes. Longer-lived samples of the unused isotopes could be collected and used in an ion source for accelerated beam experiments at ReA3, ReA12 or other accelerator facilities outside FRIB.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Spinel-olivine-pryoxene equilibrium iron isotopic fractionation and applications to natural peridotites

Eight spinel-group minerals were synthesized by a flux-growth method producing spinels with varying composition and Fe3+/Fe-tot ratios. The mean force constants of iron bonds in these minerals were determined by synchrotron nuclear resonant inelastic X-ray scattering (NRIXS) in order to determine the reduced isotopic partition function ratios (beta-factors) of these spinels. The mean force constants are strongly dependent on the Fe3+/Fe-tot of the spinel but are independent, or weakly dependent on other structural and compositional parameters. From our spectroscopic data, it is found that a single redox-dependent calibration line accounts for the effects of Fe3+/Fe-tot on the beta-factors of spinels. This calibration successfully describes the equilibrium Fe isotopes fractionation factors between spinels and silicates (olivine and pyroxenes). Our predictions are in excellent agreement with independent determinations for the equilibrium Fe isotopic fractionations for the magnetite- fayalite and the magnetite-hedenbergite couples. Our calibration applies to the entire range of Fe3+/Fe-tot ratios found in natural spinels and provides a basis for interpreting iron isotopic variations documented in mantle peridotites. Except for a few exceptions, most of the samples measured so far are in isotopic disequilibrium, reflecting metasomatism and partial melting processes.

Geothermometer↗

The long-solved problem of the best-fit straight line: application to isotopic mixing lines

Abstract. It has been almost 50 years since York published an exact and general solution for the best-fit straight line to independent points with normally distributed errors in both x and y. York's solution is highly cited in the geophysical literature but almost unknown outside of it, so that there has been no ebb in the tide of books and papers wrestling with the problem. Much of the post-1969 literature on straight-line fitting has sown confusion not merely by its content but by its very existence. The optimal least-squares fit is already known; the problem is already solved. Here we introduce the non-specialist reader to York's solution and demonstrate its application in the interesting case of the isotopic mixing line, an analytical tool widely used to determine the isotopic signature of trace gas sources for the study of biogeochemical cycles. The most commonly known linear regression methods – ordinary least-squares regression (OLS), geometric mean regression (GMR), and orthogonal distance regression (ODR) – have each been recommended as the best method for fitting isotopic mixing lines. In fact, OLS, GMR, and ODR are all special cases of York's solution that are valid only under particular measurement conditions, and those conditions do not hold in general for isotopic mixing lines. Using Monte Carlo simulations, we quantify the biases in OLS, GMR, and ODR under various conditions and show that York's general – and convenient – solution is always the least biased.

58 GEOSCIENCES↗

Short-lived photofission product yields from 238 U and 232 Th at Bremsstrahlung X-ray endpoint energies of 8, 14, and 20 MeV for nuclear forensics isotope production applications

The existing photofission product yield data sets are often based on nuclear models, and limited experimental measurements of these fission product yields have been performed. These experiments resulted in measured cumulative fission product yields (CFPYs) for 238 U and 232 Th for the bremsstrahlung X-ray endpoint energies of 8, 14, and 20 MeV. The half-lives of the reported fission products range from 1.07–40.8 s. This work is motivated by a demonstrated need for novel isotope production methods for nuclear forensics and improved nuclear data to support the nonproliferation community. A high-purity germanium detector and a pneumatic transfer system were employed for measurements of short-lived fission products, collecting data between cycles of accelerator irradiation and measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Application of isotopic labeling, and gas chromatography mass spectrometry, to understanding degradation products and pathways in the thermal-oxidative aging of Nylon 6.6

Nylon 6.6 containing 13 C isotopic labels at specific positions along the macromolecular backbone has been subjected to extensive thermal-oxidative aging at 138 °C for time periods up to 243 days. In complementary experiments, unlabeled Nylon 6.6 was subjected to the same aging conditions under an atmosphere of 18 O 2 . Volatile organic degradation products were analyzed by cryofocusing gas chromatography mass spectrometry (cryo-GC/MS) to identify the isotopic labeling. The labeling results, combined with basic considerations of free radical reaction chemistry, provided insights to the origin of degradation species, with respect to the macromolecular structure. A number of inferences on chemical mechanisms were drawn, based on 1) the presence (or absence) of the isotopic labels in the various products, 2) the location of the isotope within the product molecule, and 3) the relative abundance of products as indicated by large differences in peak intensities in the gas chromatogram. The overall degradation results can be understood in terms of free radical pathways originating from initial attacks on three different positions along the nylon chain which include hydrogen abstraction from: the (CH 2 ) group adjacent to the nitrogen atom, at the (CH 2 ) adjacent the carbonyl group, and direct radical attack on the carbonyl. Understanding the pathways which lead to Nylon 6.6 degradation ultimately provides new insight into changes that can be leveraged to detect and reduce early aging and minimize problems associated with material degradation.

36 MATERIALS SCIENCE↗

Adsorption Studies of Dilute Krypton and Xenon from Nitrogen on SBMOF-1 and Activated Charcoal for Applications in Isotope Harvesting

Adsorptive partitioning of dilute krypton (Kr) and xenon (Xe) onto Stony Brook Metal–Organic Framework (SBMOF-1) and activated charcoal (AC) from carrier nitrogen was experimentally measured at temperatures ranging from 195 to 293 K. For this purpose, a closed-loop system for gas adsorption experiments was developed. From the Kr adsorption measurements, the adsorption equilibrium constant for Kr on SBMOF-1 was calculated, yielding a value for the enthalpy of adsorption of −19 ± 1 kJ·mol –1 . The partition coefficients were utilized to estimate the extraction rates of 76 Kr, 77 Kr, and 122 Xe isotopes during isotope harvesting at the Facility for Rare Isotope Beams (FRIB). We conclude that both materials showed promising results for the extraction of noble gases from FRIB effluents using temperature swing adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GADRAS-DRF for Safeguards (FY 2025 Mid-Year/Annual Report)

Task 1 – Extract GADRAS-DRF capabilities for a workflow intuitive to safeguards analysis. This task is almost complete. Significant improvements have been made to the functionality of customizing peak fits for use in the isotopics application, as well as peak-based FSA model analysis. The remaining tasks revolve around bug fixes, testing the application, and adding a density scroll bar to isotopics for real time analysis updates. The density scroll bar values will be reflected in summary tables and the self-shielding form accessed within isotopics.

97 MATHEMATICS AND COMPUTING↗

Dynamic separation of gases using microsieves

Separation of light weight molecules, such as nitrogen, argon, and oxygen, from heavier compounds can have significant impacts on energy capture, environmental monitoring, or isotopic applications. Large-scale gas separation techniques, like gas centrifugation and membrane mitigation, can be problematic as they impart tremendous energy and induce high mechanical stress onto the instrumentation. Microsieves, also known as micronozzles or microfunnels, are developed to create physical barriers to separate specific isotopes and gases. Separation is achieved using a converging and diverging micronozzle to impose supersonic gas flow around a curved wall, and it has been used for the separation of heavy actinide isotopes in low weight gas as well as separation of low weight gas compositions of nitrogen and argon back in 1900s. However, systematic reviews of this unique technology are lacking. The application of the Laval style nozzle, which has a converging/diverging entrance fundamental to the micronozzle, is included in this review due to its importance in industrial applications in uranium (U) isotope refinement. Using advanced computational fluid dynamic (CFD) simulations, the extent of gas separation can be modelled. Herein, we first examine the literature and survey recent advances on fabrication techniques for creating curved micronozzles, methods and separation principles used to design devices. Furthermore, we then follow with highlights of CFD simulations applied to evaluate the separation effects using microsieves. Finally, identification of the gap and recommendation for future development and applications are suggested for using intrinsic molecular features and fluidic dynamics in formulating separation strategies.

30 Microfluidics↗

Water isotopes, climate variability, and the hydrological cycle: recent advances and new frontiers

Abstract The hydrologic cycle is a fundamental component of the climate system with critical societal and ecological relevance. Yet gaps persist in our understanding of water fluxes and their response to increased greenhouse gas forcing. The stable isotope ratios of oxygen and hydrogen in water provide a unique opportunity to evaluate hydrological processes and investigate their role in the variability of the climate system and its sensitivity to change. Water isotopes also form the basis of many paleoclimate proxies in a variety of archives, including ice cores, lake and marine sediments, corals, and speleothems. These records hold most of the available information about past hydrologic variability prior to instrumental observations. Water isotopes thus provide a ‘common currency’ that links paleoclimate archives to modern observations, allowing us to evaluate hydrologic processes and their effects on climate variability on a wide range of time and length scales. Building on previous literature summarizing advancements in water isotopic measurements and modeling and describe water isotopic applications for understanding hydrological processes, this topical review reflects on new insights about climate variability from isotopic studies. We highlight new work and opportunities to enhance our understanding and predictive skill and offer a set of recommendations to advance observational and model-based tools for climate research. Finally, we highlight opportunities to better constrain climate sensitivity and identify anthropogenically-driven hydrologic changes within the inherently noisy background of natural climate variability.

Dee, Sylvia (ORCID:000000022140785X)↗

Overview of Mono-Energetic Gamma-Ray Sources and Applications

Recent progress in accelerator physics and laser technology have enabled the development of a new class of tunable gamma-ray light sources based on Compton scattering between a high-brightness, relativistic electron beam and a high intensity laser pulse produced via chirped-pulse amplification (CPA). A precision, tunable Mono-Energetic Gamma-ray (MEGa-ray) source driven by a compact, high-gradient X-band linac is currently under development and construction at LLNL. High-brightness, relativistic electron bunches produced by an X-band linac designed in collaboration with SLAC NAL will interact with a Joule-class, 10 ps, diode-pumped CPA laser pulse to generate tunable {gamma}-rays in the 0.5-2.5 MeV photon energy range via Compton scattering. This MEGaray source will be used to excite nuclear resonance fluorescence in various isotopes. Applications include homeland security, stockpile science and surveillance, nuclear fuel assay, and waste imaging and assay. The source design, key parameters, and current status are presented, along with important applications, including nuclear resonance fluorescence.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗