A reduced model for the ITER divertor based on SOLPS solutions for ITER Q = 10 baseline conditions: A. identifying options for the control parameters*

Edge codes such as SOLPS coupled to neutral codes such as EIRENE have become so comprehensive and sophisticated that they now constitute, in effect, 'code-experiments' that, as for actual experiments, can benefit from interpretation using simple models and conceptual frameworks, i.e. reduced models. The first task is the identification of options for the reduced model control parameters that are best suited for control of the action of the divertor, i.e. for control of target power loading and sputter-erosion, primarily. A strong correlation between the electron temperature at the divertor target, T e,t , and the neutral deuterium D 2 density at the target, n D2,t , flux-tube resolved, has recently been reported for a number of code studies including SOLPS-4.3 modeling of a set of ~50 ITER baseline cases: Q DT = 10, q 95 = 3, P SOL = 100 MW, metallic walls, and Ne seeding. This part A of the present study reports new results for largely the same ITER cases, confirming the strong correlations reported earlier between local values of T e,t , and (i) n D2,t , and (ii) normalized volumetric losses of power and pressure in the divertor. Strong correlations have now also been found, and are reported here for the first time, between T e,t and all of the divertor target quantities of practical interest. A physical explanation for this surprising result has not been fully identified; nevertheless it has encouraging implications for reduced modeling of the ITER divertor. For such ITER conditions, (i) the global Ne injection rate, Inj Ne [Ne/s], and (ii) the electron temperature at the location on the target where the peak power deposition occurs, T e,t @q ⊥,pk (eV), are found to be promising reduced model control parameters. In the companion report, part B, a reduced model for the ITER divertor is developed and described in detail, based on reversed-direction 2 point modelling, Rev2PM. The input to the reduced model is a value of the variable pair (T et @q ⟂,pk ,Inj Ne ) and the output are values of the various target as well as divertor-entrance quantities of practical interest, e.g. q ⊥,pk , n e,Xpt (the electron density at the poloidal location of the X-point), etc. In part B the reduced model is quantitatively characterized using one half of the code cases; it is then used to successfully predict (replicate) the code values of e.g. n e,Xpt for the other half of the cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A reduced model for the ITER divertor based on SOLPS solutions for ITER Q = 10 baseline conditions: B. A reduced model based on reversed-direction two point modeling

Edge codes such as SOLPS coupled to neutral codes such as EIRENE have become so comprehensive and sophisticated that they now constitute, in effect, 'code-experiments' that, as for actual experiments, can benefit from interpretation using simple models and conceptual frameworks, i.e. reduced models. The first task is the identification of options for the reduced model control parameters that are best suited for control of the action of the divertor, i.e. for control of target power loading and sputter–erosion, primarily. A strong correlation between the electron temperature at the divertor target, T e,t , and the neutral deuterium D 2 density at the target, n D2,t , flux-tube resolved, has recently been reported for a number of code studies including SOLPS-4.3 modeling of a set of ~50 ITER baseline cases: Q DT = 10, q 95 = 3, P SOL = 100 MW, metallic walls, and Ne seeding (Pitts et al 2019). Part A of the present study reports new results for largely the same ITER cases, confirming the strong correlation reported earlier between local values of T e,t , and (i) n D2,t , and (ii) normalized volumetric losses of power and pressure in the divertor. Strong correlations have now also been found, and are reported here for the first time, between T e,t and all of the divertor target quantities of practical interest. A physical explanation for this surprising result has not as yet been fully identified; nevertheless it has encouraging implications for reduced modeling of the ITER divertor. For such ITER conditions, (i) the global Ne injection rate, Inj Ne (Ne s –1 ), and (ii) the electron temperature at the location on the target where the peak power deposition occurs, T e,t @q ⊥,pk (eV), are found to be promising reduced model control parameters. In this part B, a reduced model for the ITER divertor is developed and described in detail, based on reversed-direction two point modeling, Rev2PM. The input to the reduced model is a value of the variable pair (T e,t @q ⊥,pk , Inj Ne )for a chosen case and the output are values of the various target as well as divertor-entrance quantities of practical interest, e.g. q ⊥,pk , the electron density at the X-point, n e,Xpt , etc. The reduced model was quantitatively characterized using one half of the code cases; it was then used to successfully predict (replicate) the code values of e.g. n e,Xpt for the other half.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Erosion resistance test of SiC mirror sample for ITER divertor VUV spectrometer

A series of tests have been performed to validate the resistance of the Silicon Carbide (SiC) mirror as the first mirror material of ITER VUV spectrometers to all ITER environmental conditions. Here we focused on the erosion (and deposition) of the SiC mirror sample caused by high-energy neutral particles. The flux of neutral particles reaching the first mirror was calculated using the ZEMAX software with a simplified entrance duct model. In the calculation, the particle flux reaching the first wall is necessary and the previously reported values derived from the SOLPS calculations were used. Based on this estimated particle flux, the erosion resistance tests were performed to check the erosion effect due to the high-energy neutral particles on the first mirror of ITER divertor VUV spectrometer. In the experiment, erosion was induced by exposing the SiC mirror sample to hydrogen and deuterium plasmas (and ions). The target fluence of incident ions in experiment is based on the estimation of the flux of neutral particles in ITER. The surface shape, composition, erosion depth, and surface roughness were measured to check the damage of the mirror surface after erosion test. Based on simulations and erosion resistance tests, it was concluded that the SiC mirror can be used as the first mirror of ITER divertor VUV spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of ITER divertor shunts as a synthetic diagnostic for detachment control

Reliable diagnostics that measure the detached state of the ITER divertor plasma will be necessary to control heat flux to the divertor targets during steady state, burning plasma operation. This paper conducts an initial exploration into the feasibility of the divertor shunt diagnostic as a lightweight, robust, and real-time detachment sensor. This diagnostic is a set of shunt lead pairs that measure the voltage drop along the divertor cassette body, from which the plasma scrape-off layer (SOL) current is calculated. Using SOLPS-ITER simulations for control-relevant ITER plasma scenarios, the thermoelectric current magnitude along the SOL is shown to decrease significantly with the onset of partial detachment at the outer divertor target. Electromagnetic modelling of a simplified divertor cassette is used to develop a control-oriented inductance-resistance circuit model, from which SOL currents can be calculated from shunt pair voltage measurements. The sensitivity and frequency-response of the resulting system indicates that the diagnostic will accurately measure SOL thermoelectric currents during ITER operation. These currents will be a good measure of the detached state of the divertor plasma, making the divertor shunt diagnostic a potentially extremely valuable and physically robust sensor for real-time detachment control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New proposed ITER divertor design using carbon insert on tungsten to mitigate ELMs and secondary radiation effects on nearby components

Abstract Building a successful device for the magnetic fusion energy production is a great challenge. ITER is an international project of the tokamak based magnetic fusion design being developed for the demonstration of the feasibility of thermonuclear technologies for future realization of successful commercial fusion energy. A key obstacle to a successful magnetic fusion energy production is however, the performance during abnormal events including plasma disruptions and edge-localized modes (ELMs). A credible reactor design must tolerate at least a few of these transient events without serious consequences such as melting of the structure. This paper investigates and compares the performance of the current ITER tokamak design during two types of transient events, i.e., ELMs occurring at normal operation and disruptions during abnormal operation. We simulated the divertor components response using our integrated 3D HEIGHTS package. The simulations include self-consistent modeling of the interaction of the released core plasma particles with the initial solid divertor material, energy deposition processes, vaporization of divertor material, secondary plasma formation and MHD evolution, incident core particles collisions and scattering from this dense secondary plasma, photon radiation of secondary plasma, and the resulting heat loads on nearby components. Our simulations showed that using a small carbon insert around the strike point can significantly reduce the overall expected damage on the tungsten dome structure, reflector plates, and prevent tungsten vaporization and its potential core plasma contamination.

47 OTHER INSTRUMENTATION↗

Impact of gas injection location and divertor surface material on ITER fusion power operation phase divertor performance assessed with SOLPS-ITER *

Abstract The ITER divertor design and performance assessment, primarily based on the SOLPS-4.3 burning plasma database (Pitts R. et al 2019 Nucl. Mater. Energy 20 100696), assumes the use of beryllium (Be) as the divertor surface material and the injection of gas from the main chamber top. However, the current ITER baseline favors gas injection from the more toroidally symmetric sub-divertor region. This paper evaluates the implications of these assumptions for divertor performance in the ITER fusion power operation phase. The impact of the divertor surface material and the gas injection location on the main ions mirrors the hydrogen only low power phase scenario shown in Park J.-S. et al (2020 Nucl. Fusion 61 016021). However, during burning plasma operation, extrinsic impurity seeding will be required. In the case of neon (Ne), studied here, impurity retention is influenced by both the divertor surface material and the fueling location. Neon leakage increases due to more energetic reflection from tungsten than beryllium, but equivalent divertor performance can be achieved by adjusting the neon seeding rate. While the impurity seeding location does not affect the distributions of impurity or radiation, the fueling location does. Top fueling provides local ionization sources mainly in the mid-SOL under detached conditions, enhancing divergences of the flux there (source-driven flow), bringing stagnation points close to the fueling location, and equilibrating flows towards both targets. In contrast, the global flow pattern (in the absence of fluid drifts) in the case of sub-divertor fueling is biased towards the inner target. Impurity flows, driven by force balance, largely mirror those of the main ion flow, including the stagnation point. The case with top fueling enhances Ne retention and corresponding radiation in the outer divertor, effectively reducing the total and peak target heat fluxes by 20%–40%, compared to the case with divertor fueling. Meanwhile, the case with outer target fueling also achieves similar reductions by enhancing plasma-neutral interactions. These results suggest the possibility that the selection of the fueling location and throughput can be used as an actuator to control impurity divertor retention and divertor radiation asymmetry.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

UEDGE modeling of plasma detachment of CFETR with ITER ‐like divertor geometry by external impurity seeding

Abstract Efficient handling of high heat flux on the plasma‐facing components, particularly the divertor targets, poses a significant challenge for the Chinese Fusion Engineering Testing Reactor (CFETR) with fusion power of Gigawatt. This work investigates the divertor plasma detachment of CFETR with a standard ITER‐like divertor geometry by neon (Ne) or argon (Ar) impurity seeding using UEDGE code. The cross‐field drifts terms are switched off, and fluid neutral models and a “fixed‐fraction” impurity model are applied to enable efficient simulations for the study of CFETR detachment. In order to reduce the heat load on the divertor targets below the acceptable level (<10 MW/m 2 ), the impurity fraction ( f ), pumping speed ( S ), and upstream density are varied to identify the suitable operations window during Ne seeding. The effects of Ne and Ar impurities on the plasma detachment are compared. It is found that with the power across the core‐edge interface P SOL = 200 MW and separatrix density of 2.8 10 19 , Ne impurity fraction ≥1.7%, and Ar impurity fraction ≥0.24% can achieve the partial detachment. Achieving similar total radiation power (˜148 MW), the Ne fraction is 2.3% and the Ar fraction is 0.24%. Moreover, the simulation results indicate that Ar exhibits better power radiation efficiency and core compatibility compared with Ne.

Zhang, M. Z.↗

WEST full tungsten operation with an ITER grade divertor

The mission of WEST (tungsten-W Environment in Steady-state Tokamak) is to explore long pulse operation in a full tungsten (W) environment for preparing next-step fusion devices (ITER and DEMO) with a focus on testing the ITER actively cooled W divertor in tokamak conditions. Following the successful completion of phase 1 (2016-2021), phase 2 started in December 2022 with the lower divertor made entirely of actively cooled ITER-grade tungsten mono-blocks. A boronization prior the first plasma attempt allowed for a smooth startup with the new divertor. Despite the reduced operating window due to tungsten, rapid progress has been made in long pulse operation, resulting in discharges with a pulse length of 100 s and an injected energy of around 300 MJ per discharge. Plasma startup studies were carried out with equatorial boron nitride limiters to compare them with tungsten limiters, while Ion Cyclotron Resonance Heating assisted startup was attempted. High fluence operation in attached regime, which was the main thrust of the first campaigns, already showed the progressive build up of deposits and appearance of dust, impacting the plasma operation as the plasma fluence increased. In total, the cumulated injected energy during the first campaigns reached 43 GJ and the cumulated plasma time exceeded 5 h. Demonstration of controlled X-Point Radiator regime is also reported, opening a promising route for investigating plasma exhaust and plasma-wall interaction issues in more detached regime. This paper summarises the lessons learned from the manufacturing and the first operation of the ITER-grade divertor, describing the progress achieved in optimising operation in a full W environment with a focus on long pulse operation and plasma wall interaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constructing a new predictive scaling formula for ITER's divertor heat-load width informed by a simulation-anchored machine learning

Understanding and predicting divertor heat-load width λq is a critically important problem for an easier and more robust operation of ITER with high fusion gain. Previous predictive simulation data for λ q using the extreme-scale edge gyrokinetic code XGC1 [S. Ku et al., Phys. Plasmas 25, 056107 (2018)] in the electrostatic limit under attached divertor plasma conditions in three major US tokamaks [C. S. Chang et al., Nucl. Fusion 57, 116023 (2017)] reproduced the Eich and Goldston attached-divertor formula results [formula #14 in T. Eich et al., Nucl. Fusion 53, 093031 (2013) and R. J. Goldston, Nucl. Fusion 52, 013009 (2012)] and furthermore predicted over six times wider λ q than the maximal Eich and Goldston formula predictions on a full-power (Q = 10) scenario ITER plasma. After adding data from further predictive simulations on a highest current JET and highest-current Alcator C-Mod, a machine learning program is used to identify a new scaling formula for λ q as a simple modification to the Eich formula #14, which reproduces the Eich scaling formula for the present tokamaks and which embraces the wide λ q XGC for the full-current Q = 10 ITER plasma. Additionally, the new formula is then successfully tested on three more ITER plasmas: two corresponding to long burning scenarios with Q = 5 and one at low plasma current to be explored in the initial phases of ITER operation. The new physics that gives rise to the wider λ q XGC is identified to be the weakly collisional, trapped-electron-mode turbulence across the magnetic separatrix, which is known to be an efficient transporter of the electron heat and mass. Electromagnetic turbulence and high-collisionality effects on the new formula are the next study topics for XGC1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operating a full tungsten actively cooled tokamak: overview of WEST first phase of operation

WEST is an MA class superconducting, actively cooled, full tungsten (W) tokamak, designed to operate in long pulses up to 1000 s. In support of ITER operation and DEMO conceptual activities, key missions of WEST are: (i) qualification of high heat flux plasma-facing components in integrating both technological and physics aspects in relevant heat and particle exhaust conditions, particularly for the tungsten monoblocks foreseen in ITER divertor; (ii) integrated steady-state operation at high confinement, with a focus on power exhaust issues. During the phase 1 of operation (2017–2020), a set of actively cooled ITER-grade plasma facing unit prototypes was integrated into the inertially cooled W coated startup lower divertor. Up to 8.8 MW of RF power has been coupled to the plasma and divertor heat flux of up to 6 MW m –2 were reached. Long pulse operation was started, using the upper actively cooled divertor, with a discharge of about 1 min achieved. This paper gives an overview of the results achieved in phase 1. Perspectives for phase 2, operating with the full capability of the device with the complete ITER-grade actively cooled lower divertor, are also described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An improved model for the accurate calculation of parallel heat fluxes at the JET bulk tungsten outer divertor

Parallel heat flux calculations at the JET divertor have been based on the assumption that all incoming heat is due to the projection of the heat flux parallel to the magnetic line, q ∥ , plus a constant background. This simplification led to inconsistencies during the analysis of a series of dedicated tungsten melting experiments performed in 2013, for which infrared (IR) thermography surface measurements could not be recreated through simulations unless the parallel heat flux was reduced by 80% for L-mode and 60% for H-mode. We give an explanation for these differences using a new IR inverse analysis code, a set of geometrical corrections, and most importantly an additional term for the divertor heat flux accounting for non-parallel effects such as cross-field transport, recycled neutrals or charge exchange. This component has been evaluated comparing four different geometries with impinging angles varying from 2 to 90°. Its magnitude corresponds to 1.2%–1.9% of q ∥ , but because it is not affected by the magnetic projection, it accounts for up to 20%–30% of the tile surface heat flux. The geometrical corrections imply a further reduction of 24% of the measured heat flux. In addition, the application of the new inverse code increases the accuracy of the tile heat flux calculation, eliminating any previous discrepancy. The parallel heat flux computed with this new model is actually much lower than previously deduced by inverse analysis of IR temperatures—40% for L-mode and 50% for H-mode—while being independent of the geometry on which it is measured. This main result confirms the validity of the optical projection as long as a non-constant and non-parallel component is considered. For a given total heating power, the model predicts over 10% reduction of the maximum tile surface heat flux compared to strict optical modelling, as well as a 30% reduced sensitivity to manufacturing and assembling tolerances. Furthermore these conclusions, along with the improvement in the predictability of the divertor thermal behaviour, are critical for JET future DT operations, and are also directly applicable to the design of the ITER divertor monoblocks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Potential design problems for ITER fusion device

The international thermonuclear experimental reactor (ITER) is a worldwide project currently being built in France for the demonstration of the feasibility of thermonuclear technologies for future realization of successful commercial fusion energy. ITER is of the tokamak based design using strong magnetic fields to confine the very hot plasma needed to induce the fusion reaction. Tokamak devices are currently the front leading designs. Building a successful magnetic fusion device for energy production is of great challenge. A key obstacle to such design is the performance during abnormal events including plasma disruptions and so-called edge-localized modes (ELMs). In these events, a massive and sudden release of energy occurs quickly, due to loss of full or partial plasma confinement, leading to very high transient power loads on the reactor surface boundaries. A successful reactor design should tolerate several of these transient events without serious damages such as melting and vaporization of the structure. This paper highlights, through comprehensive state-of-the-art computer simulation of the entire ITER interior design during such transient events, e.g., ELMs occurring at normal operation and disruptions during abnormal operation, potential serious problems with current plasma facing components (PFCs) design. The HEIGHTS computer package is used in these simulations. The ITER reactor design was simulated in full and exact 3D geometry including all known relevant physical processes involved during these transient events. The current ITER divertor design may not work properly and may requires significant modifications or new innovative design to prevent serious damage and to ensure successful operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new discovery of edge localized modes suppression using ICRH

Here, the high-confinement mode (H-mode) is very important for the fusion performance of ITER and future fusion reactors. The H-mode pedestal is a region featuring strongly reduced turbulence and transport just inside the limiting flux surface with strong plasma gradients, which drive edge localized modes (ELMs) in tokamaks. The ELMs, however, are quasiperiodic relaxations of the pedestal, resulting in a series of hot plasma eruptions similar to magnetospheric substorms, solar and stellar flares, which could potentially damage the ITER divertor plates and first walls. To mitigate and suppress the ELMs in H-mode plasmas, the fusion community has tried to develop effective actuators over the past two decades. Two separate excellent inventions have been awarded to recognize their achievements. The 2018 APS excellence award in Plasma Physics Research was given to Drs. Todd E. Evans, Max E. Fenstermacher, and Richard Alan Moyer for their first experimental demonstration of the stabilization of ELMs in high-confinement diverted discharges by application of very small edge-resonant magnetic perturbations, which led to the adoption of suppression coils in the ITER design. The 2018 Fusion Technology Award from the IEEE’s Nuclear and Plasma Science Society (NPSS) was given to Dr. Larry Baylor for his work designing the fueling, pumping and disruption mitigation system for the US ITER Project and for the implementation of pellet ELM mitigation for ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of the helicon plasma flux to the target of Proto-MPEX

The ITER divertor will have to handle the boundary plasma power exhaust in the form of high heat and particle flux. The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a plasma source development device for the proposed Material Plasma Exposure eXperiment (MPEX), which is intended to create fusion reactor divertor-like plasma conditions for studying plasma material interactions. Here, ion fluxes to various targets within Proto-MPEX are found to be 5 ± 2.5 × 10 23 m –2 s -1 when using only a helicon plasma source. The fluxes along the flux tube are compared for both 30 cm in front of the target and a few cm in front of the target. The emission intensity fall-off distance in front of the target is studied via Balmer series from a visible camera looking at the target. As a result, this fall-off distance of ~2–4 cm and the dissociation and ionization mean free path of D 2 being over 0.5 m leads to a conclusion that Proto-MPEX is not in a high recycling regime with helicon only plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Periodic Surface Morphology Characteristics of Tungsten Under Simultaneous Helium and Deuterium Bombardment at 30 keV

The ITER divertor will feature tungsten monoblocks as the plasma-facing component (PFC) that will be subject to extreme temperature and radiation environments. This paper reports the development of surface morphologies on tungsten under helium bombardment at high temperatures, which has important implications for safety, retention, and PFC erosion. Polycrystalline tungsten samples were implanted in the Dual Advanced Ion Simultaneous Implantation Experiment dual-beam ion implantation experiment at the University of Wisconsin-Madison with He-only and simultaneous He-D implantation at incidence angles of 55 deg, ion energies of 30 keV, and surface temperatures of 900°C to 1100°C. Morphologies resulting from angled incidence conditions differed from those produced under normal incidence bombardment at similar energy and temperature conditions in previous work. A variety of ordered and disordered morphologies dependent on grain orientation were observed for fluences up to 6 × 10 18 He cm –2 . These morphologies displayed dependencies on crystal orientation at low fluences and incident beam directions at higher fluences. Furthermore, these structures appeared, with variation, under both single-species He and mixed He-D implantations.

36 MATERIALS SCIENCE↗

Time-dependent collisional radiative modeling of tungsten in the magnetic sheath for erosion diagnosis

Abstract Tungsten is the material of choice for the divertors in ITER, SPARC and future fusion reactors. Accurate diagnosis of tungsten erosion and migration is important for first wall life time, slag production and core performance. The addition of a magnetic presheath requires time-dependent collisional radiative effects to be included for accurate neutral tungsten collisional radiative modeling. Gross erosion measurements could be modified by a factor of 10 due to the inclusion of time-dependent effects for ITER relevant divertor conditions. A simple sputtering model and sheath density model are developed to investigate time-dependent collisional radiative effects. Neutral tungsten spectral lines populated from different metastable levels depend on model parameters leading to potential spectroscopic diagnostics of plasma parameters. Electron temperatures inferred from spectroscopic line ratios are in agreement with Langmuir probe measurements in the Compact Toroidal Hybrid.