Search NASASearch

SEARCH · Search NASA

Results for “Ice Adhesion Reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Ameliorating the sodium storage performance of hard carbon anode through rational modulation of binder

Hard carbon anodes have emerged as promising candidates for sodium-ion batteries due to their inherent advantages. Nevertheless, the surface imperfections in these materials often culminate in irreversible electrolyte consumption, fostering the development of a heterogeneous and fragile solid electrolyte interface (SEI), thereby compromising the initial Coulombic efficiency (ICE). Here, drawing inspiration from the catalytic potential of C=O (carbonyl) bonds in directing preferential salt reduction, we introduce a novel strategy that leverages the modulation of the binder, a long-term overlooked pivotal components in the electrode process. Specifically, Polymethyl methacrylate (PMMA), abundant in C=O groups, is partially substituted for PVDF, ensuring robust adhesion of the electrode material to the current collector while preserving superior mechanical properties. The accurate combination of two binders with delightful compatibility in the state-of-art electrode process, can promote a uniform formation of the SEI on the hard carbon surface enriched in inorganic components, which can ensure long-term interfacial stability and suppresses excessive solvent decomposition and facilitates Na + transfer at the interface. Consequently, the initial Coulombic efficiency of the hard carbon anode with 70 %PMMA binder achieves 86 %, with prominent cycling stability (88 % capacity retention over 500 cycles) at a high current density of 1.2 A g −1 . When paired with high loading cathodes to assemble the pouch cell, it also demonstrates stable operational scenarios.

25 ENERGY STORAGE

Energy Efficiency Improvement Approaches in Ice Related Processes

Application and development of energy efficient techniques to separate ice from different surfaces and substrates is of significant value in the context of building equipment performance. A hybrid approach to help dislocate the ice layer using advanced materials and ultrasonic vibration to lower ice adhesion strength was investigated. Application of advanced polymer materials in lowering the adhesion strength of ice was confirmed where the measured strength was lowered by 50-70% depending on the material and geometry. Additionally, utilization of induced ultrasonic vibration in further lowering the ice harvesting energy was confirmed on multiple materials and geometries. Durability of the coating enhancement was also confirmed in a thermal cycling test under realistic operating conditions. Integration of these technical approaches was implemented and validated in commercial ice makers showing energy consumption reduction by ~ 15% to 30% depending on the technical enhancement.

Cheekatamarla, Praveen

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI