Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image analysis.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Image segmentation by iterative parallel region growing with application to data compression and image analysis

Image segmentation can be a key step in data compression and image analysis. However, the segmentation results produced by most previous approaches to region growing are suspect because they depend on the order in which portions of the image are processed. An iterative parallel segmentation algorithm avoids this problem by performing globally best merges first. Such a segmentation approach, and two implementations of the approach on NASA's Massively Parallel Processor (MPP) are described. Application of the segmentation approach to data compression and image analysis is then described, and results of such application are given for a LANDSAT Thematic Mapper image.

Tilton, James C.↗

Millimeter-wave sensor image analysis

Images of an airborne, scanning, radiometer operating at a frequency of 98 GHz, have been analyzed. The mm-wave images were obtained in 1985/1986 using the JPL mm-wave imaging sensor. The goal of this study was to enhance the information content of these images and make their interpretation easier for human analysis. In this paper, a visual interpretative approach was used for information extraction from the images. This included application of nonlinear transform techniques for noise reduction and for color, contrast and edge enhancement. Results of the techniques on selected mm-wave images are presented.

Wilson, William J.↗

ON THE VERIFICATION AND VALIDATION OF GEOSPATIAL IMAGE ANALYSIS ALGORITHMS

Verification and validation (V&V) of geospatial image analysis algorithms is a difficult task and is becoming increasingly important. While there are many types of image analysis algorithms, we focus on developing V&V methodologies for algorithms designed to provide textual descriptions of geospatial imagery. In this paper, we present a novel methodological basis for V&V that employs a domain-specific ontology, which provides a naming convention for a domain-bounded set of objects and a set of named relationship between these objects. We describe a validation process that proceeds through objectively comparing benchmark imagery, produced using the ontology, with algorithm results. As an example, we describe how the proposed V&V methodology would be applied to algorithms designed to provide textual descriptions of facilities

99 GENERAL AND MISCELLANEOUS↗

Mammographic quantitative image analysis and biologic image composition for breast lesion characterization and classification

Purpose: To investigate whether biologic image composition of mammographic lesions can improve upon existing mammographic quantitative image analysis (QIA) in estimating the probability of malignancy. Methods: The study population consisted of 45 breast lesions imaged with dual-energy mammography prior to breast biopsy with final diagnosis resulting in 10 invasive ductal carcinomas, 5 ductal carcinomain situ, 11 fibroadenomas, and 19 other benign diagnoses. Analysis was threefold: (1) The raw low-energy mammographic images were analyzed with an established in-house QIA method, “QIA alone,” (2) the three-compartment breast (3CB) composition measure—derived from the dual-energy mammography—of water, lipid, and protein thickness were assessed, “3CB alone”, and (3) information from QIA and 3CB was combined, “QIA + 3CB.” Analysis was initiated from radiologist-indicated lesion centers and was otherwise fully automated. Steps of the QIA and 3CB methods were lesion segmentation, characterization, and subsequent classification for malignancy in leave-one-case-out cross-validation. Performance assessment included box plots, Bland–Altman plots, and Receiver Operating Characteristic (ROC) analysis. Results: The area under the ROC curve (AUC) for distinguishing between benign and malignant lesions (invasive and DCIS) was 0.81 (standard error 0.07) for the “QIA alone” method, 0.72 (0.07) for “3CB alone” method, and 0.86 (0.04) for “QIA+3CB” combined. The difference in AUC was 0.043 between “QIA + 3CB” and “QIA alone” but failed to reach statistical significance (95% confidence interval [–0.17 to + 0.26]). Conclusions: In this pilot study analyzing the new 3CB imaging modality, knowledge of the composition of breast lesions and their periphery appeared additive in combination with existing mammographic QIA methods for the distinction between different benign and malignant lesion types.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated thermal mapping techniques using chromatic image analysis

Thermal imaging techniques are introduced using a chromatic image analysis system and temperature sensitive coatings. These techniques are used for thermal mapping and surface heat transfer measurements on aerothermodynamic test models in hypersonic wind tunnels. Measurements are made on complex vehicle configurations in a timely manner and at minimal expense. The image analysis system uses separate wavelength filtered images to analyze surface spectral intensity data. The system was initially developed for quantitative surface temperature mapping using two-color thermographic phosphors but was found useful in interpreting phase change paint and liquid crystal data as well.

Buck, Gregory M.↗

Automated thermal mapping techniques using chromatic image analysis

Thermal imaging techniques are introduced using a chromatic image analysis system and temperature sensitive coatings. These techniques are used for thermal mapping and surface heat transfer measurements on aerothermodynamic test models in hypersonic wind tunnels. Measurements are made on complex vehicle configurations in a timely manner and at minimal expense. The image analysis system uses separate wavelength filtered images to analyze surface spectral intensity data. The system was initially developed for quantitative surface temperature mapping using two-color thermographic phosphors but was found useful in interpreting phase change paint and liquid crystal data as well.

Buck, Gregory M.↗

CFD Modeling and Image Analysis of Exhaled Aerosols due to a Growing Bronchial Tumor: towards Non-Invasive Diagnosis and Treatment of Respiratory Obstructive Diseases

Diagnosis and prognosis of tumorigenesis are generally performed with CT, PET, or biopsy. Such methods are accurate, but have the limitations of high cost and posing additional health risks to patients. In this study, we introduce an alternative computer aided diagnostic tool that can locate malignant sites caused by tumorigenesis in a non-invasive and low-cost way. Our hypothesis is that exhaled aerosol distribution is unique to lung structure and is sensitive to airway structure vari-ations. With appropriate approaches, it is possible to locate the disease site, determine the disease severity, and subsequently formulate a targeted drug delivery plan to treat the disease. This study numerically evaluated the feasibility of the proposed breath test in an image-based lung model with varying pathological stages of a bronchial squamous tumor. Large eddy simulations and a Lagran-gian tracking approach were used to model respiratory airflows and aerosol dynamics. Respira-tions of tracer aerosols of 1 µm at a flow rate of 20 L/min were simulated, with the distributions of exhaled aerosols recorded on a filter at the mouth exit. Aerosol patterns were quantified with multiple analytical techniques such as concentration disparity, spatial scanning and fractal analysis. We demonstrated that a growing bronchial tumor induced notable variations in both the airflow and exhaled aerosol distribution. These variations became more apparent with increasing tumor severity. The exhaled aerosols exhibited distinctive pattern parameters such as spatial probability, fractal dimension, and multifractal spectrum. Results of this study show that morphometric measures of the exhaled aerosol pattern can be used to detect and monitor the pathological states of respiratory diseases in the upper airway. The proposed breath test also has the potential to locate the site of the disease, which is critical in developing a personalized, site-specific drug de-livery protocol.

Aerosol breath test↗

Quantifying element incorporation in multispecies biofilms using nanoscale secondary ion mass spectrometry image analysis

Elucidating nutrient exchange in microbial communities is an important step in understanding the relationships between microbial systems and global biogeochemical cycles, but these communities are complex and the interspecies interactions that occur within them are not well understood. Phototrophic consortia are useful and relevant experimental systems to investigate such interactions as they are not only prevalent in the environment, but some are cultivable in vitro and amenable to controlled scientific experimentation. Nanoscale secondary ion mass spectrometry (NanoSIMS) is a powerful, high spatial resolution tool capable of visualizing the metabolic activities of single cells within a biofilm, but quantitative analysis of the resulting data has typically been a manual process, resulting in a task that is both laborious and susceptible to human error. In this work, the authors describe the creation and application of a semiautomated image-processing pipeline that can analyze NanoSIMS-generated data, applied to phototrophic biofilms as an example. The tool employs an image analysis process, which includes both elemental and morphological segmentation, producing a final segmented image that allows for discrimination between autotrophic and heterotrophic biomass, the detection of individual cyanobacterial filaments and heterotrophic cells, the quantification of isotopic incorporation of individual heterotrophic cells, and calculation of relevant population statistics. The authors demonstrate the functionality of the tool by using it to analyze the uptake of 15 N provided as either nitrate or ammonium through the unicyanobacterial consortium UCC-O and imaged via NanoSIMS. The authors found that the degree of 15N incorporation by individual cells was highly variable when labeled with 15 NH 4 + , but much more even when biofilms were labeled with 15 NO 3 – . In the 15 NH 4 + -amended biofilms, the heterotrophic distribution of 15 N incorporation was highly skewed, with a large population showing moderate 15 N incorporation and a small number of organisms displaying very high 15 N uptake. The results showed that analysis of NanoSIMS data can be performed in a way that allows for quantitation of the elemental uptake of individual cells, a technique necessary for advancing research into the metabolic networks that exist within biofilms with statistical analyses that are supported by automated, user-friendly processes.

59 BASIC BIOLOGICAL SCIENCES↗

Region templates: Data representation and management for high-throughput image analysis

Compartment fires exhibit unique features associated with smoke accumulation and restricted air ventilation. The objective of the present study is to evaluate the ability of CFD-based fire models to simulate these features and in particular the effects of flame extinction that results from under-ventilated fire conditions. The study is performed using FireFOAM; FireFOAM is an advanced fire modeling software developed by FM Global and is based on a general-purpose open-source software called OpenFOAM. A new flame extinction model based on the concept of a critical value of the flame Damköhler number is incorporated into FireFOAM. The performance of the extinction model is evaluated via comparisons with a previously developed experimental database corresponding to a reduced-scale, heptane-fueled, compartment fire configuration. The numerical simulations also include a description of fuel evaporation driven by the computed gas-to-liquid heat feedback. Comparisons between experimental data and numerical results provide a suitable test bed to evaluate the ability of CFD-based fire models to describe the transition from over- to under-ventilated fire conditions, as well as the transition from extinction-free conditions to conditions in which the flame experiences partial or total quenching.

Energy & Fuels↗

Characterization of coherent structures in a turbulent mixing layer by digital image analysis

Digital image analysis has been applied to a shadowgraph motion picture of a helium nitrogen mixing layer in order to characterize the coherent vortex structures in the flow. Both the primary spanwise coherent vortices and secondary streamwise vortices are considered. Pattern recognition algorithms were designed to take advantage of the more pronounced features of the vortices and of their temporal coherence to isolate them and to measure their characteristics. The resulting data base permits a deterministic description of the evolution of primary and seconary vortices.

Bernal, L. P.↗

IMAGE ANALYSIS ALGORITHMS FOR DUAL MODE IMAGING SYSTEMS

The level of detail discernable in imaging techniques has generally excluded them from consideration as verification tools in inspection regimes where information barriers are mandatory. However, if a balance can be struck between sufficient information barriers and feature extraction to verify or identify objects of interest, imaging may significantly advance verification efforts. This paper describes the development of combined active (conventional) radiography and passive (auto) radiography techniques for imaging sensitive items assuming that comparison images cannot be furnished. Three image analysis algorithms are presented, each of which reduces full image information to non-sensitive feature information and ultimately is intended to provide only a yes/no response verifying features present in the image. These algorithms are evaluated on both their technical performance in image analysis and their application with or without an explicitly constructed information barrier. The first algorithm reduces images to non-invertible pixel intensity histograms, retaining only summary information about the image that can be used in template comparisons. This one-way transform is sufficient to discriminate between different image structures (in terms of area and density) without revealing unnecessary specificity. The second algorithm estimates the attenuation cross-section of objects of known shape based on transition characteristics around the edge of the object’s image. The third algorithm compares the radiography image with the passive image to discriminate dense, radioactive material from point sources or inactive dense material. By comparing two images and reporting only a single statistic from the combination thereof, this algorithm can operate entirely behind an information barrier stage. Together with knowledge of the radiography system, the use of these algorithms in combination can be used to improve verification capability to inspection regimes and improve and substantially increase the likelihood of detecting material diversion.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Guide for Atomic Force Microscopy Image Analysis To Discriminate Heteroatoms in Aromatic Molecules [A Guide for AFM Image Analysis To Discriminate Heteroatoms in Aromatic Molecules]

Heteroatoms are essential for functional groups in organic structures and are complementary to hydrocarbon molecules in reactivities and properties. However, it is still a challenge to quickly identify heteroatoms with only non-contact atomic force microscopy (nc-AFM) to resolve chemical structures in complex unknown mixtures. This study aimed to understand the effect of elemental types on the contrast of atomic force microscopy (AFM) images using a few selected model heterocycles, including dibenzothiophene (DBT), acridine (ACR), and carbazole (CBZ). We identified several features that can be used to find common heteroatoms (S and N) and discriminated them from carbon atoms (C) using nc-AFM images alone. The mechanism of the atom and bond contrast was studied with image simulations and was found to be mostly correlated to van der Waals radii, but other factors, such as bonding geometry, electron density, and substrate interaction, need to be considered. As a result, this work will allow for rapid identification of these common heteroatoms in petroleum with AFM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Task-based strategy for optimized contrast enhanced breast imaging: Analysis of six imaging techniques for mammography and tomosynthesis

Purpose: The use of contrast agents in breast imaging has the capability of enhancing nodule detectability and providing physiological information. Accordingly, there has been a growing trend toward using iodine as a contrast medium in digital mammography (DM) and digital breast tomosynthesis (DBT). Widespread use raises concerns about the best way to use iodine in DM and DBT, and thus a comparison is necessary to evaluate typical iodine-enhanced imaging methods. This study used a task-based observer model to determine the optimal imaging approach by analyzing six imaging paradigms in terms of their ability to resolve iodine at a given dose: unsubtracted mammography and tomosynthesis, temporal subtraction mammography and tomosynthesis, and dual energy subtraction mammography and tomosynthesis. Methods: Imaging performance was characterized using a detectability index d{sup ′}, derived from the system task transfer function (TTF), an imaging task, iodine signal difference, and the noise power spectrum (NPS). The task modeled a 10 mm diameter lesion containing iodine concentrations between 2.1 mg/cc and 8.6 mg/cc. TTF was obtained using an edge phantom, and the NPS was measured over several exposure levels, energies, and target-filter combinations. Using a structured CIRS phantom, d{sup ′} was generated as a function of dose and iodine concentration. Results: For all iodine concentrations and dose, temporal subtraction techniques for mammography and tomosynthesis yielded the highest d{sup ′}, while dual energy techniques for both modalities demonstrated the next best performance. Unsubtracted imaging resulted in the lowest d{sup ′} values for both modalities, with unsubtracted mammography performing the worst out of all six paradigms. Conclusions: At any dose, temporal subtraction imaging provides the greatest detectability, with temporally subtracted DBT performing the highest. The authors attribute the successful performance to excellent cancellation of inplane structures and improved signal difference in the lesion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intelligent Image Analysis for Image-Guided Laser Hair Removal and Skin Therapy

We present the development of advanced automatic target recognition (ATR) algorithms for the hair follicles identification in digital skin images to accurately direct the laser beam to remove the hair. The ATR system first performs a wavelet filtering to enhance the contrast of the hair features in the image. The system then extracts the unique features of the targets and sends the features to an Adaboost based classifier for training and recognition operations. The ATR system automatically classifies the hair, moles, or other skin lesion and provides the accurate coordinates of the intended hair follicle locations. The coordinates can be used to guide a scanning laser to focus energy only on the hair follicles. The intended benefit would be to protect the skin from unwanted laser exposure and to provide more effective skin therapy.

laser hair removal↗

Image-analysis library

MATHPAC image-analysis library is collection of general-purpose mathematical and statistical routines and special-purpose data-analysis and pattern-recognition routines for image analysis. MATHPAC library consists of Linear Algebra, Optimization, Statistical-Summary, Densities and Distribution, Regression, and Statistical-Test packages.

Source record↗