Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image transmission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Tracking Spatiotemporal Electric Potential in Batteries Using High-Resolution Operando X‑ray Transmission Imaging

The formation of significant concentration gradients across electrolytes in batteries affects the rate at which electrochemical reactions occur. In this work, we use high-resolution operando X-ray transmission imaging to capture spatiotemporal salt concentration profiles c(x,t) in a symmetric cell comprising a polymer electrolyte sandwiched between two lithium–indium alloy electrodes during a constant-current experiment followed by open-circuit relaxation. The decay of open-circuit potential is related to the concentration dependence of the potential across concentration cells, U. We show how operando c(x,t) data can be used to calculate the spatiotemporal electric potential “inside” the polarized electrolyte. We track the spatial- and time-dependent cell potential during the constant-current step and distinguish its two contributions: a concentration overpotential governed by U. and an ohmic contribution governed by ionic conductivity. Over most of the time window, the concentration overpotential dominates. At steady state, it is a factor of 7 larger than the ohmic contribution. Such findings indicate that efforts to design new polymer electrolytes should focus on minimizing concentration gradients.

Electrical conductivity↗

In-Line Optical Transmission Imaging of Decals for Quality Control - Task 3

Quality monitoring is a critical aspect for manufacturing systems. Ideally the monitoring would be done in-line, be non-contact, non-destructive, and fast. This would enable reduced scrap and higher throughput. This poster presents an optical transmission method for evaluating and mapping coatings. With the method shown in the poster we can visualize optical variations on the macro and micro scales. This allows us to see the overall trend in loading in both the cross web and down web directions. Furthermore, we can visualize defects such dewetting spots, streaks, clumps, and pinholes where there is a lack of coating. The optical transmission signal has been found to be proportional to the IrOx loading signal using XRF measurements. Therefore, an optical transmission setup can be installed in-line and allow for a fast, non-contact method for mapping loading variations and defects.

coating uniformity↗

A machine-learning approach to measure 3D sample properties from 2D Transmission Electron Microscopy images

Transmission Electron Microscopy (TEM) is a powerful tool for the characterization of materials at the nanoscale; however, its inherent two-dimensional (2D) nature poses significant challenges to accurately measure three-dimensional (3D) properties. We introduce a supervised machine-learning model that predicts 3D structural information, such as sample thickness and curvature, from a series of conventional 2D TEM images. The model, a U-Net convolutional neural network, is trained on a large synthetic dataset generated from dynamical diffraction simulations that model TEM’s complex, nonlinear image formation, accounting for sample thickness and curvature. This physically realistic framework enables exploration of a broad parameter space impractical to sample experimentally. We demonstrate that the trained model has accurate predictions for experimental single-crystal silicon samples, achieving performance comparable to established measurement techniques. This work highlights the critical role of robust, simulation-based training in overcoming the limitations of real-world imaging artifacts and inconsistent sample geometries. By integrating machine learning with numerical simulations, we offer an efficient and scalable framework for quantitative TEM analysis, paving the way for more sophisticated 3D characterization of complex materials.

Dynamical diffraction↗

Gamma-Ray and Cosmic Ray Muon Modalities for Cargo Inspection

Screening and inspection of cargo containers are two essential methods to nondestructively examine the contents of shipment. These methods enable the detection of illicit transportation of unauthorized materials such as nuclear and radioactive materials, explosives, drugs, and so on, typically at borders or secure facilities. Although high-energy X-ray transmission is a standard system and is widely used for cargo inspection, the inherent challenges of high false-positive rates and high attenuation factors necessitate the development of complementary techniques that can increase the detection efficiency and accuracy in large and dense materials. Gamma-rays, which possess higher penetration characteristics because of their high energy, offer an alternative nonintrusive modality for cargo scanning. They represent a promising inspection method when compared to X-rays for three reasons: (1) improved ability to detect nuclear and radioactive materials, (2) higher inspection throughput rates, and (3) lower false-positive rates. Currently, there are two main gamma-ray inspection techniques, active and passive interrogation. Active interrogation can be further grouped into (1) gamma-ray transmission imaging and (2) neutron-induced gamma-ray emission detection. Gamma-ray transmission imaging utilizes differences in material densities for mapping the shipment contents and detecting anomalies. It is analogous to the X-ray transmission method; however, the high-energy photons make it more difficult to shield against, which enables more efficient performance in large and dense material inspection. Neutron-induced gamma-ray emission inspection is designed for the detection of nuclear and radioactive material because those materials emit characteristic gamma-rays when they are activated by neutron absorption. On the other hand, passive interrogation techniques rely on high-efficiency detectors to detect radiation emitted from hidden special nuclear or other radioactive materials. Similar to passive interrogation, cosmic ray muon monitoring and imaging are relatively new techniques that do not require external radioactive sources. These techniques have received attention as a potential next-generation radiographic probe to identify illicit transportation of nuclear and radioactive materials in cargo containers. Cosmic ray muons have unique features, (1) much higher energies than X-rays or gamma-rays (on the order of 10−1—104 GeV), (2) enhanced penetration capability, and (3) natural occurrence, thereby eliminating the need for induced radiation sources. These features enable cosmic ray muons to be utilized for detection of special nuclear materials in high-background-noise environments. By analyzing incoming and outgoing muon trajectories, scattering angles, and energies, it has been shown that it would be possible to locate hidden and well-shielded materials in cargo containers via three-dimensional muon tomography images or signal analysis. Gamma-rays, cosmic ray muons, and other nonintrusive cargo inspection modalities are complementary to each other, allowing them to address various cargo inspection conditions (i.e., scanning time, cost, radiation exposure level, and types of target materials). This chapter presents a detailed review of the theoretical fundamentals and technical principles behind the current gamma-ray and cosmic ray muon modalities for cargo inspection. Additionally, critical assessments and suggestions for the future directions to advance the use of gamma and muon modalities are discussed.

Bae, Junghyun↗

Grating-Based Imaging-Scattering with Portable Neutron Generator

Company: Adelphi Technology, Inc. Title: Grating-Based Imaging-Scattering with Portable Neutron Generator PI: Dr. Jay Theodore Cremer, Jr. Topic: 26a Statement of the problem or situation that is being addressed. Successful plant growth depends upon an efficient and robust root system. The plant root is part of a larger system of water and microbial flows in the soil system. While much effort has been exerted to develop an imaging system for water, microbes, and roots, the problem is challenging, and no widely accepted imaging method currently exists. The optical solutions use a highly modified soil system. X-ray imaging methods are insensitive to the soft tissues in the presence of sand. Thermal neutron imaging has been often tested, but found inadequate, due to limited access and low image resolution. This project will develop a new strategy for neutron imaging of plant/soil systems. The project will allow long duration experiments in greenhouse environments and increase the image information content to the micron scale. General statement of how this problem is being addressed. Portable, rugged thermal and fast neutron sources are being developed where portable means a two-soldier team can carry the source and power unit to survey rough terrain for explosives. In the past decade, microfabrication of X-ray and thermal/cold neutron optics has opened a new imaging strategy. The standard transmission image is now supplemented with simultaneous acquisition of a phase contrast image and an image revealing scattering features. In materials science, the interferometric neutron scattering image has been used to detect early crack formation in stressed additive manufacturing test samples. The detection requires sensitivity to scattering features at the 1-micron scale. By addition of our proposed grating-optic to Adelphi Technology’s radiographic/tomographic imaging system, which is based on portable thermal neutron source, the resulting thermal neutron scatter image of the plant/soil system, will reveal details at 1-micron. Commercial Applications and Other Benefits Neutron interferometry imaging has greater penetration through large metal components compared to industrial X-ray imaging. The low-cost, large area optics developed for greenhouse applications, combined with the robust, portable neutron generator, can then be marketed as a system for inspection of additive manufactured components. In the aerospace industry, all freshly printed components are validated with X-ray CT. Scheduled maintenance again requires X-ray CT as the ability to predict aerospace component lifetime does not yet exist. Large aerospace components are only partially observed with X-ray imaging. Key Words Neutron radiography/tomography, grating interferometry, thermal neutron generator imaging, plant root and soil imaging, rhizosphere imaging, deployable neutron imaging systems Summary for Members of Congress A rugged, portable source of thermal neutrons is adapted for neutron interferometry imaging with the addition of low-cost, 3D printed optics. The first application of our proposed deployable, compact thermal neutron generator imaging system, using a grating optic, is plant root/soil science in greenhouse settings and agricultural laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarized neutron measurements of the internal magnetization of a ferrimagnet across its compensation temperature

We present the first polarized neutron transmission image of a model Néel ferrimagnetic material, polycrystalline terbium iron garnet (Tb 3 Fe 5 O 12 , TbIG for short), as it is taken through its compensation temperature T comp where the macroscopic magnetization vanishes. Our polarized neutron imaging data and the additional supporting measurements using neutron spin echo spectroscopy and SQUID magnetometry are all consistent with a vanishing internal magnetization at T comp .

Ferrimagnetism↗

Orthogonal spatial coding with stimulated parametric down-conversion

Orthogonal optical coding is widely used in classical multi-user communication networks. Using the phase conjugation property of stimulated parametric down-conversion, we extend the current time-domain orthogonal optical coding scheme to the spatial domain to encode and decode image information. In this process, the idler beam inherits the complex conjugate of the field information encoded in the seed beam. An encoding phase mask introduced onto the input seed beam blurs the image transferred to the idler. The original image is restored by passing the coded transferred image through a corrective phase mask placed in the momentum space of the idler beam. We expect that this scheme can also inspire new techniques in secure image transmission, aberration cancellation, and frequency conversion imaging.

Xu, Yang↗

Original images, ground truth annotations, and precited masks from U-NET for a fungal species x nitrogen experiment

This document describes the “MicroVision-MV003” dataset. This folder contains three subfolders: “originals”, “predicted_masks”, and “gt_masks”. The “originals” folder contains 720 original images acquired using two imaging modalities: 360 images from overhead imaging and 360 images from transmission (raw) imaging. Naming scheme:YYYY-MM-dd__plate_strain_nitrogen-level_replication_experiment_imaging-modalityYYYY-MM-dd: 2024-12-20, 2024-12-21, 2024-12-22,2024-12-23,2024-12-24,2024-12-25,2024-12-26,2024-12-27,2024-12-28,2024-12-29,2024-12-30,2024-12-31.plate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30.strain: FG, LE.nitrogen-level: N-1, N-10, N-100.replication: 1, 2, 3, 4, 5.experiment: MV.003.imaging-modality: overhead, transmission (raw). For example, the image2024-12-20__1_FG_N-10_3_MV.003_overheadwas taken on 2024-12-20. The plate number is 1, the fungal strain is FG, the nitrogen treatment is N-10, and the replication number is 3 for experiment MV.003, acquired using the overhead imaging modality. The “predicted_masks” folder contains masks generated by a trained U-Net model for the transmission imaging modality.The “gt_masks” folder contains 326 human hand-traced masks that serve as ground truth.

09 BIOMASS FUELS↗

Neural network denoising of x-ray images from high-energy-density experiments

Noise is a consistent problem for x-ray transmission images of High-Energy-Density (HED) experiments because it can significantly affect the accuracy of inferring quantitative physical properties from these images. We consider experiments that use x-ray area backlighting to image a thin layer of opaque material within a physics package to observe its hydrodynamic evolution. The spatial variance of the x-ray transmission across the system due to changing opacity serves as an analog for measuring density in this evolving layer. The noise in these images adds nonphysical variations in measured intensity, which can significantly reduce the accuracy of our inferred densities, particularly at small spatial scales. Denoising these images is thus necessary to improve our quantitative analysis, but any denoising method also affects the underlying information in the image. In this paper, we present a method for denoising HED x-ray images via a deep convolutional neural network model with a modified DenseNet architecture. In our denoising framework, we estimate the noise present in the real (data) images of interest and apply the inferred noise distribution to a set of natural images. These synthetic noisy images are then used to train a neural network model to recognize and remove noise of that character. We show that our trained denoiser network significantly reduces the noise in our experimental images while retaining important physical features.

47 OTHER INSTRUMENTATION↗

Pulsed Infrared Thermography Nondestructive Imaging of SiC-SiC f Composite Cladding Architectures; Understanding the Performance of SiC-SiC f Composite Cladding Architectures with Cr Coating in Normal Operating and Accident Conditions in LWRs and Advanced Reactors

SiC-SiC f composites, consisting of silicon carbide fibers embedded in a silicon carbide matrix, are advanced materials with high thermal conductivity, temperature stability, and resistance to radiation damage. Traditional methods for quality control of fabricated SiC-SiC f composites involve nondestructive evaluation (NDE) with X-ray computed tomography (XCT). However, XCT imaging of typical SiC-SiC f structures for cladding applications can involve several hours. In this project, we investigate an alternative approach to NDE of SiC-SiC f composites that involves rapid (on the order of seconds) imaging with Pulsed infrared thermography (PIT). PIT images of a planar SiC-SiC f specimen show the structure of the surface monolith layer and internal SiC f structures. The capability of PIT imaging in visualizing SiC f structures is qualitatively confirmed by observing similarity in the PIT and X-ray transmission images of the same specimen. Computer vision analysis of defects in the PIT image of the monolith was performed with thresholding followed by topological structural analysis that computed geometric descriptors, including major/minor axes of fitted ellipses, area, perimeter, Feret diameter, circularity, roundness, and solidity.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of needle and armature dynamics in a gasoline direct injector by high-speed neutron imaging

In modern spark ignition engines, precise delivery of fuel with gasoline direct injection has become increasingly important in the effort to meet ever stricter efficiency and emissions regulations. Use of multiple small close-coupled injections has become more common in attempt to precisely control fuel distribution in the cylinder, but these strategies are hindered by nonlinear injection effects due to operation in the ballistic region of the solenoid-operated valve and due to armature bounce at the end of injection. Understanding the internal dynamics of the injector is crucial to minimizing and controlling non-linearity and shot-to-shot variation, but the experimental techniques available to date are capable only of tracking the position of either the top of the needle (via laser sensors or by monitoring current and voltage in the solenoid coil) or the bottom of the needle (via transparent nozzles or high-speed x-ray imaging). Furthermore, a complete picture of the axial and radial motion of valve needle has until now remained elusive. In this work, we present high-speed ensemble neutron transmission imaging of an entire 8-hole gasoline direct injector operating at 200 bar, allowing for both visualization and quantification of the actuation dynamics including lift and wobble of the valve ball, oscillation and bending of the valve needle, lift, rocking, and bounce of the armature, compression of the springs, and radial swelling of the solenoid during energization. Because neutrons offer high penetration through the metal injector while also being sensitive to the 1 H nuclei in fuel molecules, it is also possible to simultaneously see the fluid dynamics of the injection process, including filling of the sac volume, emanation of the spray through the nozzle holes and into the downstream gas, and the formation and evolution of fuel films on the tip of the injector and the walls of the spray container.

33 ADVANCED PROPULSION SYSTEMS↗

In-line, High-Throughput Quality Monitoring for Fuel Cell and Electrolyzer Components Based on Transmission and Reflection Imaging

During the manufacturing of fuel cell and electrolyzer membranes and membrane electrode assemblies (MEAs), real-time, in-line, high-throughput optical-based quality monitoring methods are essential for detecting defects and monitoring thickness variations, thus improving the performance and increasing the durability of fuel cell and electrolyzer in the hydrogen industry. For the MEAs with very opaque coatings, optical transmission-based imaging has been developed and applied in the Roll-to-Roll system using a flashlight and a high-sensitivity CCD camera. We observed high signal-to-noise ratio images while the Roll-to-Roll system ran at 5 ft/min. The entire sample image could quickly be recovered from the discrete frames using customized Python codes for automatic frame cropping and stitching. We detected significant non-uniformities in our experimental MEAs specimen. For fuel cell and low-temperature electrolysis (LTE) transparent membranes, we used optical reflectance hyperspectral imaging with interference fringe-based thickness mapping. We set up a hyperspectral camera to measure various rolls of commercial membranes. The measurement results are analyzed to find the thickness distribution of each roll and to check for defects. Transmission and reflection imaging-based quality monitoring techniques demonstrated in this project can be widely used in the mass production environment to improve the production yield and performance of hydrogen devices.

DIRECT ENERGY CONVERSION,ENGINEERING↗

Conductivity-Driven Origin of the Limiting Current in Concentrated Electrolytes

Next-generation electrolyte materials are hindered by their ability to support high currents essential for fast-charge and high-power battery applications. The maximum current supported by an electrolyte, the limiting current, is dictated by the formation of concentration gradients across the electrolyte under an electric field. Most of the literature attributes the onset of the limiting current in concentrated electrolytes to the salt concentration at the positive electrode approaching the solubility limit. Here, in this study, we leverage operando X-ray transmission imaging to measure spatiotemporal salt concentration profiles of a polymer electrolyte in a lithium–indium symmetric cell at a current exceeding the limiting current. The measurement of concentration profiles enables mapping the spatiotemporal electric potential, which comprises an ohmic contribution, governed by conductivity, and an overpotential related to maintaining concentration gradients. We find that a precipitous drop in conductivity at the positive electrode drives the divergence of electric potential, rather than a thermodynamic solubility limit.

Abdo, Emily E. [University of California, Berkeley↗

Spatiotemporal dynamics of fast electron heating in solid-density matter via XFEL

Abstract High-intensity, short-pulse lasers are crucial for generating energetic electrons that produce high-energy-density (HED) states in matter, offering potential applications in igniting dense fusion fuels for fast ignition laser fusion. High-density targets heated by these electrons exhibit spatially non-uniform and highly transient conditions, which have been challenging to characterize due to limitations in diagnostics that provide simultaneous high spatial and temporal resolution. Here, we employ an X-ray Free Electron Laser (XFEL) to achieve spatiotemporally resolved measurements at sub-micron and femtosecond scales on a solid-density copper foil heated by laser-driven fast electrons. Our X-ray transmission imaging reveals the formation of a solid-density hot plasma localized to the laser spot size, surrounded by Fermi degenerate, warm dense matter within a picosecond, and the energy relaxation occurring within the hot plasma over tens of picoseconds. These results validate 2D particle-in-cell simulations incorporating atomic processes and provide insights into the energy transfer mechanisms beyond current simulation capabilities. This work significantly advances our understanding of rapid fast electron heating and energy relaxation in solid-density matter, serving as a key stepping stone towards efficient high-density plasma heating and furthering the fields of HED science and inertial fusion energy research using intense, short-pulse lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact single-shot soft X-ray photon spectrometer for free-electron laser diagnostics

The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce:YAG scintillator, and a microscope objective to image the scintillation target onto a two-dimensional imaging detector. This spectrometer operates in segmented energy ranges which covers tens of electronvolts for each absorption edge associated with several atomic constituents: carbon, nitrogen, oxygen, and neon. The spectrometer’s performance is demonstrated at a repetition rate of 120 Hz, but our detection scheme can be easily extended to 200 kHz spectral collection by employing a fast complementary metal oxide semiconductor (CMOS) line-scan camera to detect the light from the scintillator. This compact photon spectrometer provides an opportunity for monitoring the spectrum downstream of an endstation in a limited space environment with sub-electronvolt energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strain-driven oxygen vacancy ordering in LaNiO 3 thin films revealed by integrated differential phase contrast imaging in scanning transmission electron microscopy

Rare-earth nickelates, such as LaNiO 3 (LNO), exhibit complex electronic properties, with ordered oxygen vacancies (OOV) influencing conductivity and magnetic behavior. We investigate the structural stability of strain-induced OOV phases in LNO thin films grown on SrTiO 3 substrates and the impact of Ruddlesden–Popper (RP) faults. Using high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) and integrated differential phase contrast (iDPC) STEM imaging, we conducted atomic-scale structural and compositional analyses of OOV. Geometric phase analysis (GPA) was employed to measure the strain in fault-free and RP fault regions, while density functional theory (DFT) calculations explored different OOV arrangements in the LNO phase. Simulated iDPC-STEM imaging of energy-stabilized structures was performed to correlate with experimental results. Here, our findings reveal superstructure modulation in the chemical composition and atomic-scale lattice structure in LNO, primarily due to the formation of the OOV in Ni–O layers of the LaNiO 2.5 phase. The out-of-plane compressive strain of about 2% stabilizes this phase, reducing the strain, diminishing OOV, and transforming them into LNO.

36 MATERIALS SCIENCE↗

A comparative analysis of YOLOv8 and U-Net image segmentation approaches for transmission electron micrographs of polycrystalline thin films

Metallic thin films offer a platform to experimentally study the dynamics of microstructural evolution, but the required transmission electron microscopy (TEM)-based imaging generates complex images that are challenging to segment and quantify. This work provides a comparative analysis of a new YOLOv8 model and an established U-Net model for bright-field TEM images of polycrystals, employing a framework leveraging physical observables to evaluate performance against two hand-traced benchmark datasets. This methodology obviates the comparison of large, diversely structured, and manually labeled datasets that are required to assess performance on a per-image/per-pixel basis. It is found that the YOLOv8 model, adapted for real-time instance segmentation, has up to 43× faster inferencing (NVIDIA GeForce RTX 4090) compared to U-Net and reconstructs hand-traced grain size distributions (GSDs) with excellent fidelity, finding mean diameter within 3% for grains near an optimal magnification; for grains that deviate from the optimal pixel-diameter, the size of small- (large)-diameter grains is systematically over- (under)-estimated. This is partially mitigated by including scale-aware augmentations during training. Moreover, when the bias is corrected post-inference by a rigid shift in distribution, the YOLOv8 model reproduces ground truth GSDs with exceptional fidelity, with statistical tests indicating <5% probability that the distributions are distinct. Based on ground truth data, calibration curves pertaining to this shift can be constructed for a given model. This issue is not present in the U-Net model’s results, indicating that for quantitative measurements where the true size of objects is of interest, special procedures must be implemented for YOLO-based models.

36 MATERIALS SCIENCE↗

Enhanced Monte Carlo Simulations for Electron Energy Loss Mitigation in Real-Space Nanoimaging of Thick Biological Samples and Microchips

High-resolution imaging using Transmission Electron Microscopy (TEM) is essential for applications such as grain boundary analysis, microchip defect characterization, and biological imaging. However, TEM images are often compromised by electron energy spread and other factors. In TEM mode, where the objective and projector lenses are positioned downstream of the sample, electron–sample interactions cause energy loss, which adversely impacts image quality and resolution. This study introduces a simulation tool to estimate the electron energy loss spectrum (EELS) as a function of sample thickness, covering electron beam energies from 300 keV to 3 MeV. Leveraging recent advances in MeV-TEM/STEM technology, which includes a state-of-the-art electron source with 2-picometer emittance, an energy spread of 3 × 10 -5 , and optimized beam characteristics, we aim to minimize energy spread. By integrating EELS capabilities into the BNL Monte Carlo (MC) simulation code for thicker samples, we evaluate electron beam parameters to mitigate energy spread resulting from electron–sample interactions. Based on our simulations, we propose an experimental procedure for quantitively distinguishing between elastic and inelastic scattering. The findings will guide the selection of optimal beam settings, thereby enhancing resolution for nanoimaging of thick biological samples and microchips.

36 MATERIALS SCIENCE↗