Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image transmission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Edge Detection and Shape Recognition in Neutron Transmission Images

Neutron transmission measurements are a valuable tool for nondestructively imaging special nuclear materials. Analysis of these images, however, tends to require significant user interaction to determine the sizes, shapes, and likely compositions of measured objects. Computer vision (CV) techniques can be a useful approach to automatically extracting important information from either neutron transmission images or fission-site-mapping images. An automatable approach has been developed that processes an input image and, through recursive application of CV techniques, produces a set of basic shapes that define surfaces observed in the image. These shapes can then be compared to a library of known shape configurations to determine if the measured object matches its expected configuration, as could be done behind an information barrier for arms control treaty verification inspections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Transmission Imaging with a Portable D-T Neutron Generator

Fast-neutron transmission imaging provides complementary information to x-ray transmission imaging. While fast neutron imaging resolution is generally below x-ray imaging, 14-MeV neutrons have an advantage over portable x-ray systems. Neutrons have higher transmission through high-Z materials due to a more uniform attenuation as a function of material atomic number Z compared to X-rays, and can therefore image low-Z materials inside high-Z materials. As a result, portable neutron transmission imaging has many applications, including inspection of concrete and welds for corrosion in vehicles, bridges, and other infrastructure, measurement of material levels in containers, and inspection of suspicious packages. Fast-neutron imaging is also more practical for field use than thermal-neutron imaging due to the size and shielding requirements typical of thermal-imaging systems compared to the availability of small 14.1 MeV D-T neutron generators. However, there are limitations in portable fast-neutron imaging systems, including limited neutron output, limited light produced by neutron scintillators, and lower resolution due to neutron source spot size and 2-3 mm scintillator thickness. In addition, digital-panel dark-noise is roughly 100x higher than neutron scintillator light, and variations in noise across the panel and in time is comparable to the imaging signal. Here we discuss recent efforts in developing a portable fast-neutron radiography system, including an improved neutron scintillator, mitigation of panel noise, and new commercial portable D-T neutron generators. We also present MCNP efforts to model neutron imaging, including scintillator resolution and the effects of neutron scattering from the object and surrounding materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LSST Atmospheric Transmission Imager and Slitless Spectrograph (LATISS)

LATISS, the LSST Atmospheric Transmission Imager and Slitless Spectrograph, is installed on the Rubin Auxiliary Telescope, a 1.2-meter telescope dedicated to atmospheric characterization at the NSF-DOE Vera C. Rubin Observatory site. It uses a 4k x 4k CCD, made by ITL, of the same type as used on LSSTCam. It is designed to measure atmospheric transmission and calibrate LSST observations by taking spectra of standard stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Tracking Spatiotemporal Electric Potential in Batteries Using High-Resolution Operando X‑ray Transmission Imaging

The formation of significant concentration gradients across electrolytes in batteries affects the rate at which electrochemical reactions occur. In this work, we use high-resolution operando X-ray transmission imaging to capture spatiotemporal salt concentration profiles c(x,t) in a symmetric cell comprising a polymer electrolyte sandwiched between two lithium–indium alloy electrodes during a constant-current experiment followed by open-circuit relaxation. The decay of open-circuit potential is related to the concentration dependence of the potential across concentration cells, U. We show how operando c(x,t) data can be used to calculate the spatiotemporal electric potential “inside” the polarized electrolyte. We track the spatial- and time-dependent cell potential during the constant-current step and distinguish its two contributions: a concentration overpotential governed by U. and an ohmic contribution governed by ionic conductivity. Over most of the time window, the concentration overpotential dominates. At steady state, it is a factor of 7 larger than the ohmic contribution. Such findings indicate that efforts to design new polymer electrolytes should focus on minimizing concentration gradients.

Electrical conductivity↗

In-Line Optical Transmission Imaging of Decals for Quality Control - Task 3

Quality monitoring is a critical aspect for manufacturing systems. Ideally the monitoring would be done in-line, be non-contact, non-destructive, and fast. This would enable reduced scrap and higher throughput. This poster presents an optical transmission method for evaluating and mapping coatings. With the method shown in the poster we can visualize optical variations on the macro and micro scales. This allows us to see the overall trend in loading in both the cross web and down web directions. Furthermore, we can visualize defects such dewetting spots, streaks, clumps, and pinholes where there is a lack of coating. The optical transmission signal has been found to be proportional to the IrOx loading signal using XRF measurements. Therefore, an optical transmission setup can be installed in-line and allow for a fast, non-contact method for mapping loading variations and defects.

coating uniformity↗

X-ray phase contrast imaging: Transmission functions separable in cylindrical coordinates

A Fresnel-Kirchhoff integral can be used to calculate x-ray phase contrast images when the transmission function is known. Here expressions for image intensity are derived for objects with axial symmetry for an x-ray source with non-vanishing dimensions. An expression for the image intensity is given for an x-ray source whose intensity distribution is described by a Gaussian function, from which an expression for the limiting case of a point source of radiation is found. The expressions for image intensity are evaluated for cases where the magnification is substantially greater than one, as would be employed in biological imaging. Experiments using a microfocus x-ray tube and charge coupled device camera are reported to determine the capability of the method for imaging small spherical objects, such as gold particles, which might find application as contrast agents in biomedical imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic fast neutron transmission imaging in a treaty verification setting

Measurements of the geometric configuration of objects and their material composition are needed for nuclear treaty verification purposes. We experimentally demonstrate a simple method based on monoenergetic fast neutron transmission to realize crude imaging of the geometric configuration of special nuclear material, confirm its fissionable content, and obtain information on its approximate fissile mass. In the experiment, we used monoenergetic neutrons from D(d, n)3He and T(d, n)4He reactions and a linear array of liquid scintillation detectors to perform spectroscopic neutron imaging of up to 13.7 kg of highly enriched uranium in a spherical geometry. We also show an example of detection of material diversion and confirm the presence of fissionable material based on the measurement of high-energy prompt fission neutrons, including estimating the quantity of material from the comparison of measured and predicted fission neutron emission rate. The combination of crude imaging and fissionable material detection and quantification in a simple approach may be attractive in certain treaty verification scenarios.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

2D-3D registration for prostate radiation therapy based on a statistical model of transmission images

Purpose: In external beam radiation therapy of pelvic sites, patient setup errors can be quantified by registering 2D projection radiographs acquired during treatment to a 3D planning computed tomograph (CT). We present a 2D-3D registration framework based on a statistical model of the intensity values in the two imaging modalities. Methods: The model assumes that intensity values in projection radiographs are independently but not identically distributed due to the nonstationary nature of photon counting noise. Two probability distributions are considered for the intensity values: Poisson and Gaussian. Using maximum likelihood estimation, two similarity measures, maximum likelihood with a Poisson (MLP) and maximum likelihood with Gaussian (MLG), distribution are derived. Further, we investigate the merit of the model-based registration approach for data obtained with current imaging equipment and doses by comparing the performance of the similarity measures derived to that of the Pearson correlation coefficient (ICC) on accurately collected data of an anthropomorphic phantom of the pelvis and on patient data. Results: Registration accuracy was similar for all three similarity measures and surpassed current clinical requirements of 3 mm for pelvic sites. For pose determination experiments with a kilovoltage (kV) cone-beam CT (CBCT) and kV projection radiographs of the phantom in the anterior-posterior (AP) view, registration accuracies were 0.42 mm (MLP), 0.29 mm (MLG), and 0.29 mm (ICC). For kV CBCT and megavoltage (MV) AP portal images of the same phantom, registration accuracies were 1.15 mm (MLP), 0.90 mm (MLG), and 0.69 mm (ICC). Registration of a kV CT and MV AP portal images of a patient was successful in all instances. Conclusions: The results indicate that high registration accuracy is achievable with multiple methods including methods that are based on a statistical model of a 3D CT and 2D projection images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A machine-learning approach to measure 3D sample properties from 2D Transmission Electron Microscopy images

Transmission Electron Microscopy (TEM) is a powerful tool for the characterization of materials at the nanoscale; however, its inherent two-dimensional (2D) nature poses significant challenges to accurately measure three-dimensional (3D) properties. We introduce a supervised machine-learning model that predicts 3D structural information, such as sample thickness and curvature, from a series of conventional 2D TEM images. The model, a U-Net convolutional neural network, is trained on a large synthetic dataset generated from dynamical diffraction simulations that model TEM’s complex, nonlinear image formation, accounting for sample thickness and curvature. This physically realistic framework enables exploration of a broad parameter space impractical to sample experimentally. We demonstrate that the trained model has accurate predictions for experimental single-crystal silicon samples, achieving performance comparable to established measurement techniques. This work highlights the critical role of robust, simulation-based training in overcoming the limitations of real-world imaging artifacts and inconsistent sample geometries. By integrating machine learning with numerical simulations, we offer an efficient and scalable framework for quantitative TEM analysis, paving the way for more sophisticated 3D characterization of complex materials.

Dynamical diffraction↗

On the transmission of gamma images in the guided modes of a crystal

It is shown that the propagation of gamma rays in crystals is accompanied by phenomena similar to those appearing in low-frequency optical and microwave waveguides, including effects of the image transmission and transformation. (optical fibres and waveguides)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

14YWT TEM images for LAUR [Images]

Transmission Electron Microscopy (TEM) images attached here are for machine learning study, and these will be uploaded to outer cloud at LANL.

97 MATHEMATICS AND COMPUTING↗

Transmission of Images With Ultrasonic Elastic Shear Waves on a Metallic Pipe Using Amplitude Shift Keying Protocol

Transmission of information using ultrasonic elastic waves on existing metallic pipes provides an alternative communication option across physical barriers in a highly partitioned industrial complex, such as a nuclear facility. This work investigates the feasibility of the transmission of digital images over metallic pipes. Ultrasonic communication systems for transmission of images on a nuclear-grade stainless steel pipe were assembled for bench-scale demonstration. Information carriers in this system are refracted shear waves transmitted and received with piezoelectric transducers (PZTs) operating at 2-MHz nominal frequency. The refraction and propagation of ultrasonic shear waves were modeled with COMSOL software. An amplitude shift keying (ASK) communication protocol for image transmission was developed and implemented in the GNURadio software-defined radio (SDR) environment. Digital information was converted to analog ultrasonic signals using Red Pitaya electronic boards. The performance of the ASK protocol is evaluated at the output of every block in the GNURadio program by monitoring the transmission of select characters. Using the ASK communication protocol, the transmission of the 32-KB image was demonstrated at 2-Kbps bitrate across 6-ft-long stainless steel pipe. Finally, preliminary evaluation of ultrasonic communication on the piping of a nuclear facility, such as signal transmission on bent pipes, was performed with COMSOL computer simulations.

42 ENGINEERING↗

Evaluation of Al3Mg2 precipitates and Mn-rich phase in aluminum-magnesium alloy based on scanning transmission electron microscopy imaging

Scanning transmission electron microscopy (STEM) and energy dispersive X-ray spectroscopy (EDS) were used to observe intergranular and intragranular -phase (Al3Mg2) formation and growth in as-received sample and long-term (~ 1 year) thermally treated samples of 5083-H131 alloy. Rod-shaped and equiaxed particles rich in Mn, Fe, and Cr were present in the as-received and heat treated samples. The -phase precipitated along grain boundaries as well as around and between preexisting Mn-Fe-Cr rich particles. The measured thickness of -phase along grain boundaries was lower than Zener Hillert diffusion model predicted value and the potential reasons were theoretically analyzed. Dislocation networks, grain boundaries, and different preexisting particles were observed to contribute to Mg diffusion and -phase precipitation.

Zhu, Yakun↗

Diffraction and Transmission Synchrotron Imaging at the German Light Source ANKA--Potential Industrial Applications

Diffraction and transmission synchrotron imaging methods have proven to be highly suitable for investigations in materials research and non-destructive evaluation. The high flux and spatial coherence of X-rays from modern synchrotron light sources allows one to work using high resolution and different contrast modalities. This article gives a short overview of different transmission and diffraction imaging methods with high potential for industrial applications, now available for commercial access via the German light source ANKA (Forschungszentrum Karlsruhe) and its new department ANKA Commercial Service (ANKA COS, http://www.anka-cos.de)

36 MATERIALS SCIENCE↗

Transmission diamond imaging detector

Many modern synchrotron techniques are trending toward use of high flux beams and/or beams which require enhanced stability and precise understanding of beam position and intensity from the front end of the beamline all the way to the sample. For high flux beams, major challenges include heat load management in optics (including the vacuum windows) and a mechanism of real-time volumetric measurement of beam properties such as flux, position, and morphology. For beam stability in these environments, feedback from such measurements directly to control systems for optical elements or to sample positioning stages would be invaluable. To address these challenges, we are developing diamond-based instrumented vacuum windows with integrated volumetric x-ray intensity, beam profile and beam-position monitoring capabilities. A 50 µm thick single crystal diamond has been lithographically patterned to produce 60 µm pixels, creating a >1kilopixel free-standing transmission imaging detector. This device, coupled with a custom, FPGA-based readout, has been used to image both white and monochromatic x-ray beams and capture the last x-ray photons at the National Synchrotron Light Source (NSLS). This technology will form the basis for the instrumented end-station window of the x-ray footprinting beamline (XFP) at NSLS-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental generation of optical coherence lattices

We report experimental generation and measurement of recently introduced optical coherence lattices. The presented optical coherence lattice realization technique hinges on a superposition of mutually uncorrelated partially coherent Schell-model beams with tailored coherence properties. We show theoretically that information can be encoded into and, in principle, recovered from the lattice degree of coherence. Our results can find applications to image transmission and optical encryption.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗