Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging System Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Novel 24 Ghz One-Shot Rapid and Portable Microwave Imaging System (Camera)

A novel 2D microwave imaging system at 24 GHz based on MST techniques. Enhanced sensitivity and SNR by utilizing PIN diode-loaded resonant slots. Specific slot and array design to increase transmission and reduce cross -coupling. Real-time imaging at a rate in excess of 30 images per second. Reflection as well transmission mode capabilities. Utility and application for electric field distribution mapping related to: Nondestructive Testing (NDT), imaging applications (SAR, Holography), and antenna pattern measurements.

Ghasr, M.T.↗

Multi-spectral image dissector camera system

The image dissector sensor for the Earth Resources Program is evaluated using contrast and reflectance data. The ground resolution obtainable for low contrast at the targeted signal to noise ratio of 1.8 was defined. It is concluded that the system is capable of achieving the detection of small, low contrast ground targets from satellites.

Source record↗

The Nimbus image dissector camera system - An evaluation of its meteorological applications.

Brief description of the electronics and operation of the Nimbus image dissector camera system (IDCS). The geometry and distortions of the IDCS are compared to the conventional AVCS camera on board the operational ITOS and ESSA satellites. The unique scanning of the IDCS provides for little distortion of the image, making it feasible to use a strip grid for the IDCS received in real time by local APT stations. The dynamic range of the camera favors the white end (high reflectance) of the gray scale. Thus, the camera is good for detecting cloud structure and ice features through brightness changes. Examples of cloud features, ice, and snow-covered land are presented. Land features, on the other hand, show little contrast. The 2600 x 2600 km coverage by the IDCS is adequate for the early detection of weather systems which may affect the local area. An example of IDCS coverage obtained by an APT station in midlatitudes is presented.

Sabatini, R. R.↗

A two camera video imaging system with application to parafoil angle of attack measurements

This paper describes the development of a two-camera, video imaging system for the determination of three-dimensional spatial coordinates from stereo images. This system successfully measured angle of attack at several span-wise locations for large-scale parafoils tested in the NASA Ames 80- by 120-Foot Wind Tunnel. Measurement uncertainty for angle of attack was less than 0.6 deg. The stereo ranging system was the primary source for angle of attack measurements since inclinometers sewn into the fabric ribs of the parafoils had unknown angle offsets acquired during installation. This paper includes discussions of the basic theory and operation of the stereo ranging system, system measurement uncertainty, experimental set-up, calibration results, and test results. Planned improvements and enhancements to the system are also discussed.

Meyn, Larry A.↗

Application of a Two Camera Video Imaging System to Three-Dimensional Vortex Tracking in the 80- by 120-Foot Wind Tunnel

A description is presented of two enhancements for a two-camera, video imaging system that increase the accuracy and efficiency of the system when applied to the determination of three-dimensional locations of points along a continuous line. These enhancements increase the utility of the system when extracting quantitative data from surface and off-body flow visualizations. The first enhancement utilizes epipolar geometry to resolve the stereo "correspondence" problem. This is the problem of determining, unambiguously, corresponding points in the stereo images of objects that do not have visible reference points. The second enhancement, is a method to automatically identify and trace the core of a vortex in a digital image. This is accomplished by means of an adaptive template matching algorithm. The system was used to determine the trajectory of a vortex generated by the Leading-Edge eXtension (LEX) of a full-scale F/A-18 aircraft tested in the NASA Ames 80- by 120-Foot Wind Tunnel. The system accuracy for resolving the vortex trajectories is estimated to be +/-2 inches over distance of 60 feet. Stereo images of some of the vortex trajectories are presented. The system was also used to determine the point where the LEX vortex "bursts". The vortex burst point locations are compared with those measured in small-scale tests and in flight and found to be in good agreement.

Meyn, Larry A.↗

Image dissector camera system study

Various aspects of a rendezvous and docking system using an image dissector detector as compared to a GaAs detector were discussed. Investigation into a gimbled scanning system is also covered and the measured video response curves from the image dissector camera are presented. Rendezvous will occur at ranges greater than 100 meters. The maximum range considered was 1000 meters. During docking, the range, range-rate, angle, and angle-rate to each reflector on the satellite must be measured. Docking range will be from 3 to 100 meters. The system consists of a CW laser diode transmitter and an image dissector receiver. The transmitter beam is amplitude modulated with three sine wave tones for ranging. The beam is coaxially combined with the receiver beam. Mechanical deflection of the transmitter beam, + or - 10 degrees in both X and Y, can be accomplished before or after it is combined with the receiver beam. The receiver will have a field-of-view (FOV) of 20 degrees and an instantaneous field-of-view (IFOV) of two milliradians (mrad) and will be electronically scanned in the image dissector. The increase in performance obtained from the GaAs photocathode is not needed to meet the present performance requirements.

Howell, L.↗

Multispectral image dissector camera system

A sensor system which provides registered high-solution multispectral images from a single sensor with no mechanical moving parts is reported, and the operation of an image dissector camera (IDC) is described. An earth scene 100 nautical miles wide is imaged through a single lens onto a photocathode surface containing three spectral filters, thereby producing three separate spectral signatures on the photocathode surface. An electron image is formed, accelerated, focused, and electromagnetically, deflected across an image plane which contains three sampling apertures, behind which are located three electron multipliers. The IDC system uses electromagnetic deflection for cross-track scanning and spacecraft orbit motion for along-track scanning, thus eliminating the need for a mechanical scanning mirror.

Johnson, B. L.↗

High-Resolution OH and CH2O Visualization in a Premixed Cavity-Anchored Ethylene-Air Flame in a M = 0.6 Flowfield

OH and CH2O were imaged in a premixed, cavity-anchored, ethylene-air turbulent flame using a high resolution planar laser-induced fluorescence (PLIF) system. The electrically-heated, continuous flow facility (UVa Supersonic Combustion Facility, Configuration E) consisted of a Mach 2 nozzle, an isolator with fuel injectors, a test section with a cavity flame holder and optical access, and an extender. Standard test conditions comprised total temperature 1200 K, total pressure 300 kPa, local equivalence ratio near 0.4, and local Mach number near 0.6. OH PLIF data was also collected for a case with reduced total temperature and another with reduced equivalence ratio. OH and CH2O were excited in separate experiments with light sheets at 283.55 nm and 352.48 nm, respectively. A light sheet of approximate thickness 25 ?m illuminated the stream-wise midplane. This plane was imaged for 120 mm downstream of the backward-facing step. The intensified camera system imaged OH with magnification 1.97, a square 6.67 mm field of view, and in-plane resolution of 39 ?m. The smallest observed OH structures observed were approximately 100 ?m wide. The CH2O PLIF image signal was much weaker; the smallest observed structures were approximately 200 ?m wide. Composite fluorescence images were computed for the observed area.

Geipel, Clayton M.↗

Imaging data

The primary, planetary imaging data base includes all images obtained in visible wavelengths by imaging camera systems aboard planetary spacecraft. (Excluded, due to the volume and complexity of the data, are images taken from Lunar or Earth orbital spacecraft). These estimated 145,000 individual images exist on 12,400 magnetic tapes in a digital format primarily as Experiment Data Records (EDRs); and most are accompanied by the Supplementary Experiment Data Records (SEDRs), which render the EDRs useful. Hardcopy pictures and negatives, the designated archive products for imaging experiments, along with color products and mosaics are maintained at the National space Science Data Center (NSSDC). Also included in the discussion of imaging data are two-dimensional data produced by spacecraft instruments other than optical sensors which may be considered images in a broad sense. Examples of these instruments are imaging radar systems, scanning infrared radiometers, and photopolarimeters.

Source record↗

Evaluation of a Laser-Dot Grid-Projection System for Lunar Lander Crater-Shape and Ejecta-Sheet Measurements

Development, testing, and evaluation of an active-illumination laser-dot grid-projection system was performed to evaluate its potential inclusion on an upcoming uncrewed lunar lander mission to the south pole region of the moon. Active illumination may be required for this mission due to the shallow angle of the sun at the landing location, which may cast shadows in the landing region, hindering the stereo camera imaging system’s ability to determine the pre-and post-landing lunar surface/crater shape. Testing includes characterization of the diffractive optical elements used for the grid projection, single-camera tests to determine the imaged laser dot intensity as a function of camera exposure and imaging angle relative to the laser grid projection, laser dot brightness/saturation impact on depth map calculations, angle of imaged laser grid impact on depth map calculations for steep crater edges, impact of density gradients on the depth map calculations, and the feasibility of making measurements of the ejecta sheet.

Joshua M. Weisberger↗

The Infrared Sensor Suite for SnowEx 2017

SnowEx is a winter airborne and field campaign designed to measure snow-water equivalent in forested landscapes. A major focus of Year 1 (2016-17) of NASA's SnowEx campaign will be an extensive field program involving dozens of participants from U.S. government agencies and from many universities and institutions, both domestic and foreign. Along with other instruments, two infrared (IR) sensors will be flown on a Naval Research Laboratory P-3 aircraft. Surface temperature is a critical input to hydrologic models and will be measured during the SnowEx mission. A Quantum Well Infrared Photodetector (QWIP) IR imaging camera system will be flown along with a KT-15 remote thermometer to aid in the calibration of the IR image data. Together, these instruments will measure surface temperature of snow and ice targets to an expected accuracy of less than 1C.

SnowEx↗