Search NASASearch

SEARCH · Search NASA

Results for “Imidazolium ionic liquids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Highly Porous Polyimide Gel for Use as Battery Separator with Room Temperature Ionic Liquid Electrolytes

Advanced aerospace vehicular concepts require advances in many existing technologies, including space power and energy storage systems. Batteries represent one of the major areas in need of improvement, both in terms of energy density and safety, with growing concerns over the fire safety of commercial lithium-ion batteries. This has prompted efforts to develop nonflammable battery components, namely the electrolyte and separator. Existing commercial lithium-ion batteries utilize polyolefin microporous membranes as separators with an electrolyte consisting of a lithium salt dissolved in a mixture of cyclic carbonate solvents. This separator/electrolyte combination has ionic conductivities in the range of 10 −2 to 10 −3 S/cm. However, the cyclic carbonate solvents are inherently flammable. Room-temperature ionic liquids (RTILs) appear to be a safer alternative. They offer good ionic conductivities and are inherently nonvolatile and nonflammable, giving them a safety advantage. However, many promising RTILs for battery electrolytes are not compatible with commercial polyolefin separator materials. Alternative separator materials, such as polyimides, are non-flammable and are capable of accepting RTILs into their structure. Polyimide gels, with a composition of 4,4′-oxydianiline, 3,3′,4,4′-tetracarboxylic dianhydride and cross-linked with Desmodur N3300A, possess an open-porous, fibrillar network architecture which offers a high degree of porosity (typically greater than 85% porosity) for lithium-ion transport and conduction, as well as good mechanical properties. Furthermore, these polyimide gels are compatible with selected imidazolium-based RTILs. Nonflammable separator/electrolyte systems with room-temperature conductivities in the range of 10 −3 S/cm have been evaluated. It has been demonstrated that 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide was the most promising among six RTILs screened, in terms of both ionic conductivity and constant current cycling.

Polyimide

Novel Polyimide Battery Separator Imbibed with Room-Temperature Ionic Liquids

The journey to Mars will require advancements in many existing technologies, including space power and energy storage systems. According to the 2015 NASA Technology Roadmaps, energy storage is a critical technology area to develop for both terrestrial as well as future long-term space missions. Currently, batteries represent one of the major areas in need of advancement, both in terms of energy density as well as safety. Recently, concerns regarding the fire safety of commercial lithium-ion batteries have prompted efforts to produce nonflammable battery components, namely the electrolyte and separator. Commercial lithium-ion batteries utilize polyolefin separators imbibed with a lithium salt dissolved in cyclic carbonates. This separator/electrolyte combination imparts good ionic conductivities in the range of 10(exp -2) to 10(exp -3) S/cm. However, the cyclic carbonates and polyolefin separator are inherently flammable. Room-temperature ionic liquids (RTILs) appear to be a safer alternative to cyclic carbonates. They offer good ionic conductivities, similar to those observed in cyclic carbonates, but are inherently nonvolatile and nonflammable giving them a safety advantage. Many promising RTILs for battery electrolytes are not compatible with commercial polyolefin separator materials. Polyimide aerogels possess an open-porous, fibrillar network architecture which offers a high degree of porosity (typically greater than 85 porous), required for lithium ion conduction, as well as good mechanical properties. Furthermore, these materials are compatible with all tested RTILs. By creating a polyimide gel and imbibing the gel with a RTIL containing a lithium salt instead of super critically drying them to form aerogels, a nonflammable separator/electrolyte system with conductivities in the range of 1x10(exp -3) S/cm has been demonstrated.

Polyimide

Study of Stable Cathodes and Electrolytes for High Specific Density Lithium-Air Battery

Future NASA missions require high specific energy battery technologies, greater than 400 Wh/kg. Current NASA missions are using "state-of-the-art" (SOA) Li-ion batteries (LIB), which consist of a metal oxide cathode, a graphite anode and an organic electrolyte. NASA Glenn Research Center is currently studying the physical and electrochemical properties of the anode-electrolyte interface for ionic liquid based Li-air batteries. The voltage-time profiles for Pyr13FSI and Pyr14TFSI ionic liquids electrolytes studies on symmetric cells show low over-potentials and no dendritic lithium morphology. Cyclic voltammetry measurements indicate that these ionic liquids have a wide electrochemical window. As a continuation of this work, sp2 carbon cathode and these low flammability electrolytes were paired and the physical and electrochemical properties were studied in a Li-air battery system under an oxygen environment.

cathodes

Experimental Effects of Scaling on the Performance of Ion Rockets Employing Electron-Bombardment Ion Sources

A scaling program was undertaken to establish the relations between performance parameters and the size of the electron bombardment ion source. The experimental results of this investigation are the subject of this paper. Two geometrically similar sources, a 5- and a 20-cm-diameter beam source, were scaled from a 10-cm-diameter source to allow a performance comparison to be made. The three ion sources are compared for ion chamber characteristics and overall engine efficiency. The results of the chamber investigations are compared with scaling variations indicated by simple plasma theory. The effects of size on operating limits are also discussed. Mercury was used as the propellant in this investigation.

Power Supply

ELECTRIC PROPULSION- A NEW TECHNOLOGY

Within the past 3 years, electric thrust devices have passed from the first exploratory feasibility experiments to the flight-engineered hardware phase. This rapid surge of development has been punctuated by equally rapid improvements in the performance figures of electrical thrust devices. The most spectacular advances were made in ion engine technology. Total energy expenditure per ion pair has gone from 35,000 ev in 1958 to about 600 ev at the present time leading to power utilization efficiencies of up to 80 per cent, depending upon the specific impulse. The percentage of the particles intercepting the accelerating and focusing electrodes has been reduced from more than 50 per cent in 1958 to less than 0.01 per cent at the present time. Great improvements in ion current per unit area have also been realized, leading to greater thrust "pressures."

ELECTRIC PROPULSION

Equivalent System Mass Comparison of ECLSS CO2 Removal Technologies

This project employs equivalent system mass (ESM) analyses to evaluate and compare state-of-the-art spacecraft CO2 removal systems. The ESM methodology converts sizing characteristics such as volume, power, and cooling requirements into a unified metric of mass, allowing for simple quantitative comparison of equipment impacts on a system level. Comparison of six high TRL technologies – the Carbon Dioxide Removal System (CDRS), Thermal Amine Scrubber (TAS), Carbon Dioxide Removal Assembly (CDRA), Four-Bed CO2 Scrubber (4BCO2), CO2 and Humidity Control Swing Bed (CHC), and the Carbon Dioxide Removal by Ionic Liquid Sorbent (CDRILS) – was achieved using an existing ESM spreadsheet tool that formerly ranked such technologies for consideration on Gateway. Fidelity of the tool was increased through revision with the most up-to-date sizing and performance data for each technology. ESM values were then estimated using NASA-supplied Lunar, Martian, and low-Earth orbit habitat infrastructure costs. This paper details the ESM approach used, lists major performance variables for each CO2 removal option, and summarizes conclusions of the technology comparison. The results are intended to act as a guide to assist programs in their selection of CO2 technologies best suited for a specific vehicle or mission.

Madeleine C Oliver

Equivalent System Mass Comparison of ECLSS CO 2 Removal Technologies

This project employs equivalent system mass (ESM) analyses to evaluate and compare state-of-the-art spacecraft CO 2 removal systems. The ESM methodology converts sizing characteristics such as volume, power, and cooling requirements into a unified metric of mass, allowing for simple quantitative comparison of equipment impacts on a system level. Comparison of six high TRL technologies – the Carbon Dioxide Removal System (CDRS), Thermal Amine Scrubber (TAS), Carbon Dioxide Removal Assembly (CDRA), Four-Bed CO 2 Scrubber (4BCO2), CO 2 and Humidity Control Swing Bed (CHC), and the Carbon Dioxide Removal by Ionic Liquid Sorbent (CDRILS) – was achieved using an existing ESM spreadsheet tool that formerly ranked such technologies for consideration on Gateway. Fidelity of the tool was increased through revision with the most up-to-date sizing and performance data for each technology. ESM values were then estimated using NASA-supplied Lunar, Martian, and low-Earth orbit habitat infrastructure costs. This paper details the ESM approach used, lists major performance variables for each CO 2 removal option, and summarizes conclusions of the technology comparison. The results are intended to act as a guide to assist programs in their selection of CO 2 technologies best suited for a specific vehicle or mission.

Madeleine Oliver

Screen Channel Liquid Acquisition Device Outflow Tests in Liquid Hydrogen

This paper presents experimental design and test results of the recently concluded 1-g inverted vertical outflow testing of two 325x2300 full scale liquid acquisition device (LAD) channels in liquid hydrogen (LH 2 ). One of the channels had a perforated plate and internal cooling from a thermodynamic vent system (TVS) to enhance performance. The LADs were mounted in a tank to simulate 1-g outflow over a wide range of LH 2 temperatures (20.3 – 24.2 K), pressures (100 – 350 kPa), and flow rates (0.010 – 0.055 kg/s). Results indicate that the breakdown point is dominated by liquid temperature, with a second order dependence on mass flow rate through the LAD. The best performance is always achieved in the coldest liquid states for both channels, consistent with bubble point theory. Higher flow rates cause the standard channel to break down relatively earlier than the TVS cooled channel. Both the internal TVS heat exchanger and subcooling the liquid in the propellant tank are shown to significantly improve LAD performance.

Fuel Depot

Comparison of Cryogenic Flow Boiling in Liquid Nitrogen and Liquid Hydrogen Chilldown Experiments

This paper presents a comparison between experimental results from recent liquid hydrogen (LH 2 ) transfer line chilldown experiments at high Reynolds (Re) numbers versus liquid nitrogen (LN 2 ) experiments conducted at low Re numbers. Parasitic heat leak, inner wall temperatures, inner wall heat fluxes, and heat transfer coefficients are computed to compare between the two systems. Analysis of temperature traces and flow visualization indicates that the chilldown process evolves much more rapidly at higher Re numbers due to a quick transition from vapor flow to annular liquid flow and near immediate liquid contact along the pipe walls. The lower kinematic viscosity and surface tension of LH 2 , along with reduced parasitic heat leak and higher Re numbers relative to the LN 2 experiments, causes chilldown to proceed almost immediately into the nucleate boiling regime, in comparison to low Re flows where >75% of the chilldown is spent in vapor film boiling.

Cryogenic Heat Transfer Coefficient

Ionene membrane battery separator

Ionic transport characteristics of ionenes, insoluble membranes from soluble polyelectrolyte compositions, are studied for possible application in a battery separator. Effectiveness of the thin film of separator membrane essentially determines battery lifetime.

Moacanin, J.

Analysis of Screen Channel LAD Bubble Point Tests in Liquid Methane at Elevated Temperature

This paper examines the effect of varying the liquid temperature and pressure on the bubble point pressure for screen channel Liquid Acquisition Devices in cryogenic liquid methane using gaseous helium across a wide range of elevated pressures and temperatures. Testing of a 325 x 2300 Dutch Twill screen sample was conducted in the Cryogenic Components Lab 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. Test conditions ranged from 105 to 160K and 0.0965 – 1.78 MPa. Bubble point is shown to be a strong function of the liquid temperature and a weak function of the amount of subcooling at the LAD screen. The model predicts well for saturated liquid but under predicts the subcooled data.

Reaction Control System

Advanced Liquid Propulsion Systems

The Advanced Liquid Propulsion Systems program is investigating selected problems generated by spacecraft operational requirements for propulsion systems capable of high inherent reliability, long-term storage in the space environment, multiple start in free fall (zero gravity), and engine throttling. The solutions proposed to satisfy these requirements are coordinated for practical application in a system.

PROPULSION SYSTEM

Test Data Analysis of the Thermodynamic Vent System-Augmented Top Spray Injector Liquid Nitrogen Transfer Experiments

Traditionally, a cryogenic tank must be pre-chilled to some “target” temperature before the main vent valve can be closed to attempt a non-vented fill (NVF) of cryogenic liquid propellant. This methodology is particularly attractive for performing in-space transfer of cryogens due to the unknown location of the liquid/vapor interface in microgravity and the high likelihood of venting liquid if the vent valve is opened during transfer. This paper presents in-depth test data analysis of a Thermodynamic Vent System (TVS) augmented injector used for cryogenic tank chilldown and fill experiments of a thin-walled Titanium tank. Eight tests were conducted using liquid nitrogen across a range of inlet conditions and boundary conditions, and three different chilldown/fill methods. For four of the tests, the injector sprays liquid into the tank as normal, but also uses a TVS heat exchanger to cool the metallic injector itself as well as the main incoming liquid stream. Results show that using the TVS augmented injector simplifies transfer operation via enhanced condensation at the injector surface at the cost of sacrificing only a small amount of propellant.

Thermodynamic Vent System