Search NASA⌕ Search

SEARCH · Search NASA

Results for “Impedance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Reversed Impedance-Based Stability Criterion for IBR Grids

The existing impedance-based stability criterion is effective for analyzing local control interactions; however, it is difficult to scale the existing criterion to analyze wide-area control interactions among numerous IBRs through a complex power system network. The scaled version of the existing criterion requires the impedance response of each IBR in the system as well as of the network looking from all the IBRs. It is quite challenging to obtain all these impedance responses because of the computational effort and the requirement of separately scanning the impedance of the network and the IBRs. We propose a reversed criterion for the impedance-based stability analysis to address these problems. In contrast to the existing criterion, the reversed criterion analyzes the stability of a power system when an IBR is disconnected from the system. The reversed criterion estimates the impact of an IBR on the frequency and damping of power system oscillation modes using the impedance scans of only the IBR and the grid at its terminal. It can be sequentially applied at different IBRs to evaluate their impact on the power system stability. In addition to scalability, the reversed criterion gives flexibility to focus only on a few selected IBRs, depending on their rating, the magnitude of oscillations observed at their terminals, and the vendor support available for implementing stabilizing control system updates. The reversed criterion is demonstrated on a 14-bus power system with 100% IBRs.

control interactions↗

Constant current loop impedance measuring system that is immune to the effects of parasitic impedances

A constant current loop measuring system is provided for measuring a characteristic of an environment. The system comprises a first impedance positionable in the environment, a second impedance coupled in series with said first impedance and a parasitic impedance electrically coupled to the first and second impedances. A current generating device, electrically coupled in series with the first and second impedances, provides a constant current through the first and second impedances to produce first and second voltages across the first and second impedances, respectively, and a parasitic voltage across the parasitic impedance. A high impedance voltage measuring device measures a voltage difference between the first and second voltages independent of the parasitic voltage to produce a characteristic voltage representative of the characteristic of the environment.

Anderson, Karl F.↗

Impedance-Based Prediction of SSR-Generated Harmonics in Doubly-Fed Induction Generators

Doubly-fed induction generators (DFIGs) are prone to subsynchronous resonance (SSR) with series-compensated transmission lines and experiencing SSR-generated harmonics of wide-ranging magnitudes. This paper presents a large-signal impedance-based approach for the prediction of the magnitude of SSR-generated harmonics in DFIGs. Note that the large-signal impedance of a network shows variation in its impedance response with the magnitude of perturbation at its terminals. It is discovered in this paper that the impedance of a series-compen- sated transmission line starts changing with the magnitude of SSR because of the metal-oxide varistor-based protection of series capacitors in the line. The changing line impedance halts the growth of the SSR beyond a certain point, where the DFIG forms a limit-cycle mode and emits harmonics at the SSR frequency. The discovered role of the protection of series capacitors in SSR not only enables the prediction of SSR-generated harmonics but also can be used for the timely detection of an SSR event to avoid system disruption and sudden loss of bulk generation. The large- signal impedance-based prediction of SSR-generated harmonics in DFIG-based wind and hydro generators is demonstrated using numerical simulations of a 2.5-MVA, 690-V DFIG supplying to a series-compensated transmission line.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scattering patterns of dihedral corner reflectors with impedance surface impedances

The radar cross section patterns of lossy dihedral corner reflectors are calculated using a uniform geometrical theory of diffraction for impedance surfaces. All terms of up to third order reflections are considered for patterns in the principal plane. The surface waves are included whenever they exist for reactive surface impedances. The dihedral corner reflectors examined have right, obtuse, and acute interior angles, and patterns over the entire 360 deg azimuthal plane are calculated. The surface impedances can be different on the four faces of the dihedral corner reflector; however, the surface impedance must be uniform over each face. Computed cross sections are compared with a moment method technique for a dielectric/ferrite absorber coating on a metallic corner reflector. The analysis of the dihedral corner reflector is important because it demonstrates many of the important scattering contributors of complex targets including both interior and exterior wedge diffraction, half-plane diffraction, and dominant multiple reflections and diffractions.

Balanis, Constantine A.↗

Computer code for scattering from impedance bodies of revolution. Part 3: Surface impedance with s and phi variation. Analytical and numerical results

The third phase of the development of the computer codes for scattering by coated bodies that has been part of an ongoing effort in the Electromagnetics Laboratory of the Electrical Engineering and Computer Science Department at the University of Illinois at Chicago is described. The work reported discusses the analytical and numerical results for the scattering of an obliquely incident plane wave by impedance bodies of revolution with phi variation of the surface impedance. Integral equation formulation of the problem is considered. All three types of integral equations, electric field, magnetic field, and combined field, are considered. These equations are solved numerically via the method of moments with parametric elements. Both TE and TM polarization of the incident plane wave are considered. The surface impedance is allowed to vary along both the profile of the scatterer and in the phi direction. Computer code developed for this purpose determines the electric surface current as well as the bistatic radar cross section. The results obtained with this code were validated by comparing the results with available results for specific scatterers such as the perfectly conducting sphere. Results for the cone-sphere and cone-cylinder-sphere for the case of an axially incident plane were validated by comparing the results with the results with those obtained in the first phase of this project. Results for body of revolution scatterers with an abrupt change in the surface impedance along both the profile of the scatterer and the phi direction are presented.

Uslenghi, Piergiorgio L. E.↗

Method of Adjusting Acoustic Impedances for Impedance-Tunable Acoustic Segments

A method is provided for making localized decisions and taking localized actions to achieve a global solution. In an embodiment of the present invention, acoustic impedances for impedance-tunable acoustic segments are adjusted. A first acoustic segment through an N-th acoustic segment are defined. To start the process, the first acoustic segment is designated as a leader and a noise-reducing impedance is determined therefor. This is accomplished using (i) one or more metrics associated with the acoustic wave at the leader, and (ii) the metric(s) associated with the acoustic wave at the N-th acoustic segment. The leader, the N-th acoustic segment, and each of the acoustic segments exclusive of the leader and the N-th acoustic segment, are tuned to the noise-reducing impedance. The current leader is then excluded from subsequent processing steps. The designation of leader is then given one of the remaining acoustic segments, and the process is repeated for each of the acoustic segments through an (N-1)-th one of the acoustic segments.

Jones, Kennie H↗

Broad Applicability of Electrochemical Impedance Spectroscopy to the Measurement of Oxygen Nonstoichiometry in Mixed Ion and Electron Conductors

Oxygen non-stoichiometry is a fundamental feature of mixed ion and electron conductors (MIECs). In this work a general electrochemical method for determining non-stoichiometry in thin film MIECs, via measurement of the chemical capacitance, is demonstrated using ceria and ceria-zirconia (Ce 0.8 Zr 0.2 O 2-δ ) as representative materials. A.C. impedance data are collected from both materials at high temperature (750-900 °C) under reducing conditions with oxygen partial pressure (pO 2 ) in the range 10-13 to 10-20 atm. Additional measurements of ceria-zirconia films are made under relatively oxidizing conditions with pO 2 in the range 0.2 to 10 -4 atm and temperatures of 800-900 °C. Under reducing conditions, the impedance spectra are described by a simple circuit in which a resistor is in series with a resistor and capacitor in parallel, and thickness dependent measurements are used to resolve the capacitance into interfacial and chemical terms. Under more oxidizing conditions, the impedance spectra (of Ce 0.8 Zr 0.2 O 2-δ ) reveal an additional diffusional feature, which enables determination of the ionic resistance of the film in addition to the capacitance, and hence the transport properties. A generalized mathematical formalism is presented for recovering the non-stoichiometry from the chemical capacitance, without recourse to defect chemical models. The ceria non-stoichiometry values are in good agreement with literature values determined by thermogravimetric measurements but display considerably less scatter and are collected on considerably shorter timescales. Here, the thermodynamic analysis of Ce 0.8 Zr 0.2 O 2-δ corroborates earlier findings that introduction of Zr into ceria enhances its reducibility.

08 HYDROGEN↗

Towards robust autonomous impedance spectroscopy analysis: A calibrated hierarchical Bayesian approach for electrochemical impedance spectroscopy (EIS) inversion

Distribution-based analyses, such as the distribution of relaxation times (DRT) and the distribution of diffusion times (DDT), present model-free alternatives to equivalent circuit modeling for analysis of electrochemical impedance spectroscopy (EIS) data. However, reconstructing such distributions from noisy impedance data is an ill-posed problem that must be solved with specialized inversion algorithms, requiring careful control and tuning. Furthermore, most inversion algorithms developed to date can only solve problems of limited complexity. Herein, we present a new hierarchical Bayesian method for EIS inversion, leveraging efficient algorithms for optimization and Hamiltonian Monte Carlo (HMC) sampling to solve models of arbitrary complexity. We overcome the challenge of ad-hoc parameter tuning by encoding intrinsic characteristics of the DRT and DDT into flexible prior distributions and “pre-calibrating” the model to simulated data. This approach is versatile, highly robust to noise, and provides quantitative estimates of both the error structure of the data and the uncertainty in the recovered distributions. The model is validated with simulated data to demonstrate accurate recovery of the DRT and the DDT. The method also shows promise for simultaneous recovery of multiple distributions, raising the intriguing possibility of semi-autonomous EIS analysis and ad-hoc model construction. Finally, the practical utility of the method is illustrated with experimental data. Throughout, we draw comparisons to several recently published EIS inversion methodologies.

36 MATERIALS SCIENCE↗

Transient pulse‐based impedance characterisation of DC‐link capacitor for EV systems

In this study, a method for impedance characterisation of DC‐link capacitors based on transient pulse analysis is proposed. The fundamentals of the concept are presented and design considerations are discussed. The functionality of the proposed approach is supported by SPICE simulation with two different commercial capacitors from different manufacturers and validated with experimental results. Experimental results for equivalent series resistance, equivalent series inductance (ESL) and capacitance estimation are presented for commercial DC‐link capacitors and compared with component analyser results. The simulation and experimental results show that the proposed method is a promising candidate for capacitance and ESL estimation of capacitors in EV traction systems.

Gurpinar, Emre↗

Sequence Impedance Measurement of Utility-Scale Wind Turbines and Inverters – Reference Frame, Frequency Coupling, and MIMO/SISO Forms

Sequence impedance responses with or without considering frequency coupling in both MIMO and SISO forms are increasingly used for the stability analysis of three-phase power electronic systems; however, many aspects of sequence impedance measurement are not fully explored. It is not clear if the sequence impedance has a reference frame similar to the dq impedance. If so, the role of the grid voltage angle estimation in aligning the sequence impedance reference frame has not been discussed. Additionally, existing methods for measuring the sequence impedance with frequency coupling are complicated, are not feasible for large wind turbines and inverters, and provide the sequence impedance responses in only either MIMO or SISO form. This paper presents a sequence impedance measurement method that considers the frequency coupling, performs reference frame alignment, demonstrates the impact of the grid voltage angle estimation, and obtains the sequence impedance response in both MIMO and SISO forms. This paper demonstrates the proposed method and practical problems associated with the sequence impedance measurement of utility-scale wind turbines and inverters on a 1.9-MW Type III wind turbine and a 2.2-MVA inverter using an impedance measurement system built around a 7-MW/13.8-kV grid simulator and a 5-MW dynamometer.

17 WIND ENERGY↗

Identifying Potential Sub-Synchronous Oscillations Using Impedance Scan Approach: Preprint

This paper presents an impedance scan study on the real-world power system in Australia that has observed 17 to 20 Hz intermittent subsynchronous oscillations. Through the impedance scan of each of the IBRs, both individually and collectively, potential resonance modes are identified. The impedance scans were carried out using electromagnetic transient PSCAD models of the network. The network comprises of site-specific, black-boxed models of IBRs supplied by the generators. The impedance scan approach was divided in three major steps: (1) the first step is to identify IBRs where impedance analysis needs to be performed based on the magnitude of oscillations observed at their points of interconnection (POIs); (2) the second step focuses on performing impedance scans at selected IBRs in single-machine infinite-bus (SMIB) configuration to identify internal resonance modes of an IBR and to evaluate if any of these modes become unstable under certain grid conditions; (3) the third step performs impedance scans at a few selected IBRs while connected to the wider network model to obtain the impedance response of both the IBR and the grid - this step evaluates control interactions among IBRs. The impedance scan study found that a few IBRs have an underdamped resonance mode at around 17 Hz, which becomes unstable under a certain operating condition. Another interesting finding was that certain IBRs increase the effective grid impedance seen by another IBR in proximity for a particular operating condition. Under this operating condition, the resulting subsynchronous oscillation mode is more pronounced due to a combination of control interactions among IBRs through the transmission network under study and a resonance mode inside the IBRs.

control interactions↗

Journal bearing impedance descriptions for rotordynamic applications

The paper deals with the development of analytic descriptions for plain circumferentially-symmetric fluid journal bearings, which are suitable for use in rotor dynamic analysis. The bearing impedance vector is introduced, which defines the bearing reaction force components as a function of the bearing motion. Impedances are derived directly for the Ocvirk (short) and Sommerfeld (long) bearings, and the relationships between the impedance vector and the more familiar mobility vector are developed and used to derive analytic impedance for finite-length bearings. The static correctness of the finite-length cavitating impedance is verified. Analytic stiffness and damping coefficient definitions are derived in terms of an impedance vector for small motion around an equilibrium position and demonstrated for the finite-length cavitating impedance. Nonlinear transient rotordynamic simulations are presented for the short pi and 2-pi impedances and the finite-length cavitating impedance. It is shown that finite-length impedance yields more accurate results for substantially less computer time than the short-bearing numerical-pressure-integration approach.

Childs, D.↗

Uncertainty and Sensitivity Analyses of a Two-Parameter Impedance Prediction Model

This paper presents comparisons of predicted impedance uncertainty limits derived from Monte-Carlo-type simulations with a Two-Parameter (TP) impedance prediction model and measured impedance uncertainty limits based on multiple tests acquired in NASA Langley test rigs. These predicted and measured impedance uncertainty limits are used to evaluate the effects of simultaneous randomization of each input parameter for the impedance prediction and measurement processes. A sensitivity analysis is then used to further evaluate the TP prediction model by varying its input parameters on an individual basis. The variation imposed on the input parameters is based on measurements conducted with multiple tests in the NASA Langley normal incidence and grazing incidence impedance tubes; thus, the input parameters are assigned uncertainties commensurate with those of the measured data. These same measured data are used with the NASA Langley impedance measurement (eduction) processes to determine the corresponding measured impedance uncertainty limits, such that the predicted and measured impedance uncertainty limits (95% confidence intervals) can be compared. The measured reactance 95% confidence intervals encompass the corresponding predicted reactance confidence intervals over the frequency range of interest. The same is true for the confidence intervals of the measured and predicted resistance at near-resonance frequencies, but the predicted resistance confidence intervals are lower than the measured resistance confidence intervals (no overlap) at frequencies away from resonance. A sensitivity analysis indicates the discharge coefficient uncertainty is the major contributor to uncertainty in the predicted impedances for the perforate-over-honeycomb liner used in this study. This insight regarding the relative importance of each input parameter will be used to guide the design of experiments with test rigs currently being brought on-line at NASA Langley.

Jones, M. G.↗