Search NASA⌕ Search

SEARCH · Search NASA

Results for “Implantation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector↗

Ion implanted photodiode detectors in epitaxial /Ga/x/In/1-x//As

Ion implanted p-n junction photodiodes in epitaxially grown (Ga(x)In(1-x))As material are reported on here. Photoresponse in these diodes was investigated for approximately the entire composition range of x between zero and one. High values for quantum efficiency were obtained for the devices with a high value of x.

Ajmera, P. K.↗

Half-life measurement of the 199-keV isomeric state in Ga 76

Background: Isomeric states in atomic nuclei are a sensitive probe of their underlying microscopic structure and can be used to study the evolution of shell structure far from stability. Recent studies have identified and provided detailed spectroscopy of isomers in neutron-rich nuclei with Z = 28-50. Isomeric states in the odd-odd gallium isotopes have been reported for all gallium isotopes from A = 72 to A = 80 with the exception of 76 Ga. Purpose: The purpose of this experiment was to observe short-lived isomeric states in the vicinity of 78 Ni. Methods: In-beam fragmentation of a 86 Kr primary beam at the National Superconducting Cyclotron Laboratory produced radioactive ions which were delivered to and deposited in a Ce Br 3 scintillator coupled to a position-sensitive photomultiplier tube. Beta-delayed γ rays were measured by ancillary HPGe clover and LaBr 3 detectors which surrounded the implantation detector. Results: The previously observed J π = 1 + , 199-keV level in 76 Ga, populated following the β decay of 76 Zn, was identified as isomeric with a half-life of 34(1) stat. (8) sys. ns. Shell-model calculations suggest this state is formed by the coupling of protons in negative-parity configurations to 1/2 - neutron configurations. Transition strengths assuming a ground-state spin of J = 2 and J = 3 were determined from the experimental data.

59 ≤ A ≤ 89↗

Cosmic ray particle dosimetry and trajectory tracing

Five pocket mice (Perognathus longimembris) were flown on Apollo XVII, each with a solid-state (plastic) nuclear track detector implanted beneath its scalp. The subscalp detectors were sensitive to HZE cosmic ray particles with a LET greater than or approximately equal to 0.15 million electron volts per micrometer (MeV/micron). A critical aspect of the dosimetry of the experiment involved tracing individual particle trajectories through each mouse head from particle tracks registered in the individual subscalp detectors, thereby establishing a one-to-one correspondence between a trajectory location in the tissue and the presence or absence of a lesion. The other major aspect was the identification of each registered particle. An average of 16 particles with Z greater than or equal to 6 and 2.2 particles with Z greater than or equal to 20 were found per detector. The track density, 29 tracks/sq cm, when adjusted for detection volume, was in agreement with the photographic emulsion data from an area dosimeter located next to the flight package.

Cruty, M. R.↗

Low spin spectroscopy of neutron-rich Cl 43 , 44 , 45 via β - and β n decay

In this article, β - decay studies of neutron-rich isotopes 43,45 S performed at the National Superconducting Cyclotron Laboratory are reported. β -delayed $\gamma$ transitions were detected by an array of 16 clover detectors surrounding the Beta Counting Station, which consists of a 40×40 double-sided silicon strip detector followed by a single-sided silicon strip detector. β -decay half-lives were extracted for 43,45 S by correlating implants and decays in the pixelated implant detector and by considering further coincidences with $\gamma$ transitions in the daughter nuclei. Further, the level structures of 43,45 Cl are expanded by the addition of 20 and 8 new $\gamma$ transitions in 43 Cl and 45 Cl respectively, and core-excited negative-parity states were observed in both nuclei for the first time. For 45 S, a large fraction of the β -decay strength was observed feeding neutron-unbound states in 45 Cl, which, decaying by delayed neutrons, populated excited states in the β ⁢1⁢ n daughter, 44 Cl. Experimental observations were compared to detailed shell-model calculations using the SDPFSDG-MU interaction to highlight the role of the diminished N = 28 neutron shell gap and the near degeneracy of the proton s 1/2 and d 3/2 orbitals in the structure of the neutron-rich Cl isotopes. The current work also provides further support to a ground-state spin-parity assignment of 3/2 + in 45 Cl.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of digital electronics for the search of SHE nuclei using GARIS-II/III at RIKEN

This work describes the implementation of a digital data acquisition system for the search and study of short-lived isotopes or superheavy elements at the GARIS-III separator at the RIKEN Nishina Center. Here a reduction to 26 ± 0.5 keV in the average value of the Full Width at Half Maximum of the alpha spectrum at 7.133 MeV was achieved, combined with a reduction of the dead time of the overall system to around a few tens of nanoseconds for the detection of very fast decay chains. Moreover, we measured a reduction of the background induced by particles crossing the implantation detector using pulse shape analysis techniques. The detail of the optimization and analysis will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of β -delayed proton emitters in the region of 100 Sn

An experiment on neutron-deficient nuclei in the region of doubly magic 100 Sn was carried out at the Radioactive Ion Beam Factory (RIBF) at the RIKEN Nishina Center in Japan. 𝑁 ≈ 𝑍 ≈ 50 nuclei were produced following fragmentation of an intense primary 124 Xe beam and implanted in the Advanced Implantation Detector Array silicon setup for the first study of proton-rich nuclei with this system at RIKEN. Measurements of the 𝛽-delayed proton emitter decay half-lives, branching ratios and proton energy spectra of nuclei in the region of 100 Sn were performed, with improved precision in many cases. New results for the energy spectrum of 101 Sn are presented, where a 2.03(5)-MeV peak was observed. In conclusion, these results are compared to shell-model calculations, using the recent precise measurement of the 101 In proton separation energy are presented.

Appleton, C. J. [Univ. of Edinburgh, Scotland (Uni↗

Measuring the β-decay Properties of Neutron-rich Exotic Pm, Sm, Eu, and Gd Isotopes to Constrain the Nucleosynthesis Yields in the Rare-earth Region

Abstract The β -delayed neutron-emission probabilities of 28 exotic neutron-rich isotopes of Pm, Sm, Eu, and Gd were measured for the first time at RIKEN Nishina Center using the Advanced Implantation Detector Array (AIDA) and the BRIKEN neutron detector array. The existing β -decay half-life ( T 1/2 ) database was significantly increased toward more neutron-rich isotopes, and uncertainties for previously measured values were decreased. The new data not only constrain the theoretical predictions of half-lives and β -delayed neutron-emission probabilities, but also allow for probing the mechanisms of formation of the high-mass wing of the rare-earth peak located at A ≈ 160 in the r -process abundance distribution through astrophysical reaction network calculations. An uncertainty quantification of the calculated abundance patterns with the new data shows a reduction of the uncertainty in the rare-earth peak region. The newly introduced variance-based sensitivity analysis method offers valuable insight into the influence of important nuclear physics inputs on the calculated abundance patterns. The analysis has identified the half-lives of 168 Sm and of several gadolinium isotopes as some of the key variables among the current experimental data to understand the remaining abundance uncertainty at A = 167–172.

79 ASTRONOMY AND ASTROPHYSICS↗

Study directed at development of an implantable biotelemetry ion detector

A literature search was conducted to currently update known information in the field of ion-selective electrodes. The review attempts to identify present trends in cation and anions selective electrodes pertinent to the area of bioimplantable units. An electronic circuit was designed to provide the high impedance interface between the ion-selective sensors and signal-processing equipment. The resulting design emphasized the need for low power and miniaturization. Many of the circuits were constructed and used to evaluate the ion-selective electrodes. A cuvette capable of holding the ion-selective and the reference electrodes was designed and constructed. This equipment was used to evaluate commercially available ion-selective electrodes and the electrodes designed and constructed in the study. The results of the electrode tests are included.

Hanley, L. D.↗

Characterization of Large-Area Silicon Ionization Detectors for the ACE Mission

We report on extensive tests of large-area (10cm diameter) high-purity ion-implanted silicon detectors for th Solar Isotope Spectrometer (SIS), and lithium-drifted silicon detetors for the Cosmic Ray Isotope Spectrometer (CRIS), which are under development for launch on the Advanced Composition Explorer (ACE) mission.

silicon↗

Intruder Detector

The shadowy prowler is attempting a break-in, unaware that his presence has already been detected and reported by the device in the lower left corner of the photo. It is part of a three-element ntruder Detecti on System developed by NASA's Ames Research Center from technology acquired in the Apollo lunar exploration program. Apollo astronauts left behind on the moon small portable seismic (shock) detectors to record subsurface vibrations and transmit to Earth data on the moon's density and thickness. A similar seismic detector is the key component of the lntruder Detection System. Encased in a stainless steel tube, the detector is implanted in the ground outside the facility being protected-home, bank, industrial or other facilities. The vibration-sensing detector picks up the footstep of anyone within a preset range. The detector is connected by cable to the transmitter, which relays the warning to a portable radio receiver. The radio alerts plant guards or home occupants by emitting an audible tone burst for each footstep.

Source record↗

New techniques for the detection and capture of micrometeoroids

In order to understand the origin and distribution of the biogenic elements and their compounds in the solar system, it will be necessary to study material from many classes of objects. Chemical, elemental, and isotopic measurements of returned samples of comets, asteroids, and possibly extra-solar system dust clouds would provide information on a particularly important class: the primitive objects. Extraterrestrial micron-sized particles in the vicinity of earth are one source of such materials that might otherwise be inaccessible. The Space Station appears to be an eminently suitable platform from which to collect and detect these various particles. The primary challenge, however, is to collect intact, uncontaminated particles which will be encounted at tens of kilometers per seconds. A concept for a micrometeoroid detector that could be deployed at a Space Station has been developed which uses a large area detector plate implanted with acoustic transducers. When an impact event occurs, the resulting signal is subjected to spectral analysis providing positive detection, momentum information, and angle of incidence. The primary advantage of this detector is the large area which increases the probability of measuring events.

Wolfe, J. H.↗

New techniques for the detection and capture of micrometeoroids

In order to understand the origin and distribution of the biogenic elements and their compounds in the solar system, it will be necessary to study materials from many classes of objects. Chemical, elemental, and isotopic measurements of returned samples of comets, asteroids, and possibly extra-solar system dust clouds would provide information on a particularly important class: primitive objects. Extraterrestrial micron-sized particles in the vicinity of Earth are one source of such materials that might otherwise be inaccessible. The Space Station appears to be an eminently suitable platform from which to collect and detect these various particles. The primary challenge, however, is to collect intact, uncontaminated particles which will be encountered at tens of kilometers per seconds. A concept for a micrometeoroid detector that could be deployed from the Space Station was developed which uses a large area detector plate implanted with acoustic transducers. When an impact event occurs, the resulting signal is subjected to spectral analysis providing positive detection, momentum information, and angle of incidence. The primary advantage of this detector is the large area which increases the probability of measuring events. A concept of a nondestuctive micrometeoroid collector for use from a Space Station was also developed. The collector utilizes input port charging of the incoming particle followed by staged high voltage deceleration for nondestructive capture. Low velocity particles (local contamination) would be rejected due to insufficient energy and only uncontaminated micrometeoroids would be collected.

Wolfe, J. H.↗

Identification of a new isomeric state in 76 Zn following the β decay of 76 Cu

Background: The evolution of nuclear shell structure far from stability can be explored by identifying and measuring the properties of isomers. Neutron-rich nuclei between the Z = 28 and Z = 50 closed shells have been the subject of recent studies which have identified a number of 0.1 - 10 µs isomers and measured detailed spectroscopic properties. Purpose: The purpose of this analysis was to identify and measure the properties of short-lived isomeric states populated following β decay in Z ≈ 30, N ≈ 50 nuclei near the doubly magic nucleus 78 Ni. Methods: Here, radioactive ions produced by beam fragmentation at the National Superconducting Cyclotron Laboratory were implanted into a CeBr 3 scintillator coupled to a pixelated photomultiplier tube. Ancillary arrays of HPGe clover and LaBr 3 detectors were positioned around the implantation detector to measure β-delayed γ rays. Results: The previously observed 2634-keV level in 76 Zn, populated following the β decay of 76 Cu, was identified as isomeric with a half-life of 25.4(4) ns. A combination of timing and γ-ray spectroscopy was used to confirm this assignment. Shell-model calculations were performed and indicate that this state may be a high-spin negativeparity state formed by the occupation of the ν0g 9/2 orbital. Conclusions: A new isomeric state in 76 Zn has been identified and its half-life was measured. Ambiguity about the structure of this state could be resolved with further experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New techniques for the detection and capture of micrometeoroids

In order to understand the origin and distribution of the biogenic elements and their compounds in the solar system, it will be necessary to study material from many classes of objects. Chemical, elemental, and isotopic measurements of returned samples of comets, asteroids, and possibly extrasolar system dust clouds would provide information on a particularly important class: the primitive objects. Extraterrestrial micron-sized particles in the vicinity of Earth are one source of such materials that might otherwise be inaccessible. The Space Station appears to be an eminently suitable platform from which to collect and detect these various particles. The primary challenge, however, is to collect intact, uncontaminated particles which will be encountered at tens of kilometers per seconds. A concept for a micrometeoroid detector that could be deployed from the Space Station was developed which uses a large area detector plate implanted with acoustic transducers. A concept of a nondestructive micrometeoroid collector for the Space Station was also developed. Particles collected would then be returned to Earth for subsequent analysis.

Wolfe, J. H.↗

Observations of the 3-D distribution of interplanetary electrons and ions from solar wind plasma to low energy cosmic rays

The 3-D Plasma and Energetic Particle instrument on the GGS Wind spacecraft (launched November 1, 1994) is designed to make measurements of the full three-dimensional distribution of suprathermal electrons and ions from solar wind plasma to low energy cosmic rays, with high sensitivity, wide dynamic range, good energy and angular resolution, and high time resolution. Three pairs of double-ended telescopes, each with two or three closely sandwiched passivated ion implanted silicon detectors measure electrons and ions from approximately 20 keV to greater than or equal to 300 keV. Four top-hat symmetrical spherical section electrostatic analyzers with microchannel plate detectors, a large and a small geometric factor analyzer for electrons and a similar pair for ions, cover from approximately 3 eV to 30 keV. We present preliminary observations of the electron and ion distributions in the absence of obvious solar impulsive events and upstream particles. The quiet time electron energy spectrum shows a smooth approximately power law fall-off extending from the halo population at a few hundred eV to well above approximately 100 keV The quiet time ion energy spectrum also shows significant fluxes over this energy range. Detailed 3-D distributions and their temporal variations will be presented.

Lin, R. P.↗

Ion-implanted extrinsic Ge photodetectors with extended cutoff wavelength

Far-IR Ge detectors fabricated using boron ion implantation are shown to exhibit operating characteristics compatible with requirements for low background applications. Device parameters such as low dark currents, reasonably good sensitivity, and extended wavelength threshold demonstrate that ion-implanted Ge far-IR detectors offer promise for use in astrophysics instrumentation.

Wu, I. C.↗

New method for level-lifetime measurements with thick scintillators

Level lifetimes provide key insight into the structure of atomic nuclei and serve as stringent tests of theoretical descriptions. Though several methods for determining level lifetimes exist for both reaction measurements and decay studies, here the focus is on techniques involving the direct measurement of time differences between population and subsequent depopulation of excited states. The techniques presented herein are broadly applicable across multiple timing ranges, but the approach is specifically described for the βγ timing method. A multi-step, amplitude-dependent time walk correction was employed to address the data analysis complications that arise from using thick scintillators for electron detection. Further, additional corrections for the depth of the interaction must also be performed when the parent isotope has been implanted into the detector. Techniques are presented for performing these time walk and depth of interaction corrections. Subsequently, a new Monte Carlo method utilizing measured detector responses obtained from the data, coupled with chi-square minimization, is presented for extracting excited state lifetimes ≳ 100 picoseconds. The framework of this Monte Carlo method is developed for the decay of a state in 68 Zn with a known 1.6 ps half life, which is considered prompt given the detection sensitivity of the technique, and then benchmarked using two other excited states in neutron-rich Ni isotopes with 120(34) ps and 1.05(3) ns half lives. Using this new method which takes into account the thick scintillator used, these same half lives were measured to be 135(10) ps and 1.04(24) ns, respectively. The overall good agreement demonstrates the validity of the technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗