Search NASA⌕ Search

SEARCH · Search NASA

Results for “In Situ Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

In Situ Measurement of Tritium Permeation Through Stainless Steel

The TMIST-2 irradiation experiment was conducted in the Advanced Test Reactor at Idaho National Laboratory to evaluate tritium permeation through Type 316 stainless steel (316 SS). The interior of a 316 SS seamless tube specimen was exposed to a 4He carrier gas mixed with a specified quantity of tritium (T2) to yield partial pressures of 0.1, 5, and 50 Pa at 292° and 330°C. In-situ tritium permeation measurements were made by passing a He-Ne sweep gas over the outer surface of the specimen to carry the permeated tritium to a bubbler column for liquid scintillation counting. An irradiation enhancement factor (IEF) was determined by comparing in-situ permeation data with a correlation for ex-reactor hydrogen permeation through austenitic stainless steel developed from literature data and reported by Le Claire. Nominal values for the IEF ranged between 3 and 5 for 316 SS. In-situ permeation data were also used to derive an in-reactor permeation correlation as a function of temperature and pressure. In addition, the triton recoil contribution to tritium permeation, which results from the transmutation of 3He to T, was also evaluated by introducing a 4He carrier gas mixed with 3He at a partial pressure of 1013 Pa at 330°C. Less than 3% of the tritium resulting from 3He transmutation contributed to tritium permeation.

In-Reactor↗

In situ measurement of CuPt alloy ordering using strain anisotropy

The optical and electrical properties of many III-V alloys change with the degree of CuPt atomic ordering, which is very sensitive to growth conditions. The bulk ordered alloy is elongated along the normal to the ordered planes, and is asymmetrically strained when coherent to a cubic substrate. Here, we demonstrate in situ measurement of the anisotropic strain due to ordering using two-dimensional wafer curvature. The measurement is sensitive to bulk anisotropies, and so is complementary to other in situ measurements that are sensitive to surface anisotropies. Using ab initio calculations, we determine a maximum strain anisotropy of 0.27% between [110] and [1{sup ¯}10] when perfectly ordered single-variant GaInP{sub 2} is coherent to a (001) cubic substrate. We relate the in situ measurement of strain anisotropy on various GaInP{sub 2} samples to ex situ measurements of the order parameter to validate the measurement and confirm the capability to predict material properties. The measurement monitors change in ordering during growth, useful for quickly determining the growth condition dependence of ordering or monitoring order-disorder transitions. More generally, this measurement technique could, in principle, be used to monitor phase changes in any epitaxial system for which the strain anisotropy of the two phases differs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In situ measurement of low-Z material coating thickness on high Z substrate for tokamaks

Rutherford backscattering of energetic particles can be used to determine the thickness of a coating of a low-Z material over a heavier substrate. Simulations indicate that 5 MeV alpha particles from an {sup 241}Am source can be used to measure the thickness of a Li coating on Mo tiles between 0.5 and 15 μm thick. Using a 0.1 mCi source, a thickness measurement can be accomplished in 2 h of counting. This technique could be used to measure any thin, low-Z material coating (up to 1 mg/cm{sup 2} thick) on a high-Z substrate, such as Be on W, B on Mo, or Li on Mo. By inserting a source and detector on a moveable probe, this technique could be used to provide an in situ measurement of the thickness of Li coating on NSTX-U Mo tiles. A test stand with an alpha source and an annular solid-state detector was used to investigate the measurable range of low-Z material thicknesses on Mo tiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ measurement of power conversion efficiency and molecular ordering during thermal annealing in P3HT:PCBM bulk heterojunction solar cells

Bulk heterojunction organic solar cells hold much promise as commercially viable sources of renewable energy due to their relatively inexpensive fabrication. Developing a fundamental knowledge of how processing conditions influence solar power conversion efficiency will enable rational and efficient design, optimization, and control of new organic solar cell materials. In this report, we use a combination of in situ current–voltage measurements and grazing-incidence wide-angle X-ray scattering experiments at elevated temperature to correlate the changes in photoconversion efficiency to the changes in the molecular ordering of a poly(3-hexylthiophene):[6,6]-phenyl-C₆₁-butyric acid methyl ester (P3HT:PCBM) bulk heterojunction active layer. In situ measurements of current–voltage characteristics were used to optimize the power conversion efficiency and the resulting thermal processing was in agreement with studies from repeated heating and cooling cycles. The improvements in short circuit current with thermal annealing were correlated to an increase in the population of face-on oriented crystallites of P3HT rather than improvements in molecular ordering of PCBM.

14 SOLAR ENERGY↗

Near infrared laser annealing of CdTe and in-situ measurement of the evolution of structural and optical properties

The high performance of polycrystalline CdTe thin film solar cells is enabled by annealing in the presence of Cl. This process is typically carried out for tens of minutes resulting in reduction of defect states within the bandgap among other beneficial effects. In this work, we investigate laser annealing as a means of rapidly annealing CdTe using a continuous wave sub-bandgap 1064 nm laser. The partial transmission of the beam allows us to monitor the annealing process in-situ and in real time. We find that optoelectronic and structural changes occur through two distinct kinetic processes resulting in the removal of deep defects and twinned regions, respectively. A multilayer optical model including surface roughness is used to interpret both the in-situ transmission as well as ex-situ reflectivity measurements. These experiments demonstrate beneficial material changes resulting from sub-bandgap laser-driven CdCl{sub 2} treatment of CdTe in minutes, which is an important step towards accelerating the processing of the CdTe absorber layer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ measurement of ferric iron in lunar glass beads using Fe-XAS

Through use of a new X-ray Absorption Spectroscopy (XAS) calibration for Fe3+ analysis in silicate glasses, the first direct measurements of ferric iron in natural lunar picritic glasses are presented. Lunar glass beads from the Apollo sample collection contain up to 60.0% Fe3+. No correlation with melt chemical properties, such as Mg# or weight % TiO2, or physical properties, such as bead diameter, was observed. Fe3+/ΣFe is negatively correlated with NBO/T. These elevated Fe3+/ΣFe values reflect eruption and post-eruption oxidation due to magmatic degassing of H or OH. Glass beads observed to be zoned to lower Fe3+/ΣFe rims may represent a subsequent reduction in the lunar vacuum prior to cooling through the glass transition temperature

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct in situ measurement of coupled magnetostructural evolution in a ferromagnetic shape memory alloy and its theoretical modeling

Ferromagnetic shape memory alloys (FSMAs) have shown great potential as active components in next generation smart devices due to their exceptionally large magnetic-field-induced strains and fast response times. During application of magnetic fields in FSMAs, as is common in several magnetoelastic smart materials, there occurs simultaneous rotation of magnetic moments and reorientation of twin variants, resolving which, although critical for design of new materials and devices, has been difficult to achieve quantitatively with current characterization methods. At the same time, theoretical modeling of these phenomena also faced limitations due to uncertainties in values of physical properties such as magnetocrystalline anisotropy energy (MCA), especially for off-stoichiometric FSMA compositions. Here, in situ polarized neutron diffraction is used to measure directly the extents of both magnetic moments rotation and crystallographic twin-reorientation in an FSMA single crystal during the application of magnetic fields. Additionally, high-resolution neutron scattering measurements and first-principles calculations based on fully relativistic density functional theory are used to determine accurately the MCA for the compositionally disordered alloy of Ni 2 Mn 1.14 Ga 0.86 . The results from these state-of-the-art experiments and calculations are self-consistently described within a phenomenological framework, which provides quantitative insights into the energetics of magnetostructural coupling in FSMAs. Furthermore, based on the current model, the energy for magnetoelastic twin boundaries propagation for the studied alloy is estimated to be ~150 kJ/m 3 .

36 MATERIALS SCIENCE↗

In situ measurement of electromigration-induced transient stress in Pb-free Sn-Cu solder joints by synchrotron radiation based X-ray polychromatic microdiffraction

Electromigration-induced hydrostatic elastic stress in Pb-free SnCu solder joints was studied by in situ synchrotron X-ray white beam microdiffraction. The elastic stresses in two different grains with similar crystallographic orientation, one located at the anode end and the other at the cathode end, were analyzed based on the elastic anisotropy of the Beta-Sn crystal structure. The stress in the grain at the cathode end remained constant except for temperature fluctuations, while the compressive stress in the grain at the anode end was built-up as a function of time during electromigration until a steady state was reached. The measured compressive stress gradient between the cathode and the anode is much larger than what is needed to initiate Sn whisker growth. The effective charge number of Beta-Sn derived from the electromigration data is in good agreement with the calculated value.

36 MATERIALS SCIENCE↗

Kinematic analysis of in situ measurement during chemical mechanical planarization process

Chemical mechanical planarization (CMP) is the most widely used planarization technique in semiconductor manufacturing presently. With the aid of in situ measurement technology, CMP tools can achieve good performance and stable productivity. However, the in situ measurement has remained unexplored from a kinematic standpoint. The available related resources for the kinematic analysis are very limited due to the complexity and technical secret. In this paper, a comprehensive kinematic analysis of in situ measurement is provided, including the analysis model, the measurement trajectory, and the measurement time of each zone of wafer surface during the practical CMP process. In addition, a lot of numerical calculations are performed to study the influences of main parameters on the measurement trajectory and the measurement velocity variation of the probe during the measurement process. All the efforts are expected to improve the in situ measurement system and promote the advancement in CMP control system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemical ionization tandem mass spectrometer for the in situ measurement of methyl hydrogen peroxide

A new approach for measuring gas-phase methyl hydrogen peroxide [(MHP) CH{sub 3}OOH] utilizing chemical ionization mass spectrometry is presented. Tandem mass spectrometry is used to avoid mass interferences that hindered previous attempts to measure atmospheric CH{sub 3}OOH with CF{sub 3}O{sup -} clustering chemistry. CH{sub 3}OOH has been successfully measured in situ using this technique during both airborne and ground-based campaigns. The accuracy and precision for the MHP measurement are a function of water vapor mixing ratio. Typical precision at 500 pptv MHP and 100 ppmv H{sub 2}O is {+-}80 pptv (2 sigma) for a 1 s integration period. The accuracy at 100 ppmv H{sub 2}O is estimated to be better than {+-}40%. Chemical ionization tandem mass spectrometry shows considerable promise for the determination of in situ atmospheric trace gas mixing ratios where isobaric compounds or mass interferences impede accurate measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Confocal Raman Microscopy for in Situ Measurement of Octanol–Water Partitioning within the Pores of Individual C 18 -Functionalized Chromatographic Particles

Octanol water partitioning is one of the most widely used predictors of hydrophobicity and lipophilicity. Traditional methods for measuring octanol water partition coefficients (K ow ), including shake flasks and generator columns, require hours for equilibration and milliliter quantities of sample solution. These challenges have led to development of smaller scale methods for measuring K ow . Recent advances in microfluidics have produced faster and smaller-volume approaches to measuring K ow . As flowing volumes are reduced, however, separation of water and octanol prior to measurement and detection in small volumes of octanol phase are especially challenging. In this work, we reduce the receiver volume of octanol water partitioning measurements from current practice by six-orders-of-magnitude, to the femtoliter scale, by using a single octanol filled reversed-phase, octadecylsilane-modified (C 18 -silica) chromatographic particle as a collector. The fluid handling challenges of working in such small volumes are circumvented by eliminating post equilibration phase separation. Partitioning is measured in situ within the pore confined octanol phase using confocal Raman microscopy, which is capable of detecting and quantifying a wide variety of molecular structures. Equilibration times are fast (less than a minute) because molecular diffusion is efficient over distance scales of micrometers. The demonstrated amount of analyte needed to carry out a measurement is very small, less than 50 fmol, which would be a useful attribute for drug screening applications or testing of small quantities of environmentally sensitive compounds. The method is tested for measurements of pH-dependent octanol-water partitioning of naphthoic acid, and the results are compared to both traditional shake-flask measurements and sorption onto C 18 -modified silica without octanol present within the pores.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ measurement of the rheological properties and agglomeration on cementitious pastes

Various factors influence the rheology of cementitious pastes, with the most important being the mixing protocol, mixture proportions, and mixture composition. This study investigated the influence of ground-granulated blast-furnace slag, on the rheological behavior of cementitious pastes. In tandem with the rheological measurements, fresh state microstructural measurements were conducted using three different techniques: A coupled stroboscope-rheometer, a coupled laser backscattering-rheometer, and a conventional laser diffraction technique. Laser diffraction and the coupled stroboscope-rheometer were not good measures of the in situ state of flocculation of a sample. Rather, only the laser backscattering technique allowed for in situ measurement on a highly concentrated suspension (cementitious paste). Using the coupled laser backscattering-rheometer technique, a link between the particle system and rheological behavior was determined through a modeling approach that takes into account agglomeration properties. A higher degree of agglomeration was seen in the ordinary Portland cement paste than pastes containing the slag and this was related to the degree of capillary pressure in the paste systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗