Search NASA⌕ Search

SEARCH · Search NASA

Results for “Indoor air quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Healthy Buildings Guide for Small Businesses: A Quick Reference to Improve Indoor Air Quality (Restaurants Excluded)

Indoor air pollutant concentrations can be higher than those outdoors, putting occupants at risk. These pollutants come from a variety of sources: materials used to build and furnish indoor spaces, retail products and services, and occupants themselves. Ventilation, temperature, and humidity also affect indoor air quality. It is important to consider the documented benefits of healthy indoor environments at any time – not just during a public health crisis – and it is key to consider the indoor air quality where we do business as well as at home. Small businesses vary in size, services, products, ownership style, and building mechanical systems, yet all benefit from healthy indoor spaces for employees and customers. This guide provides steps, in conjunction with public health guidance, that small businesses can take to improve and maintain indoor air quality. Small businesses often have unique ownership structures – the building owner and business owner can be different parties – so this guide addresses both building and business owner action items. There are many ways to pursue healthy indoor air, including eliminating, minimizing, and/or controlling the contaminants we bring in, and removing or diluting any existing contaminants through ventilation, filtration, air cleaning, and/or disinfection. Best results are achieved through a comprehensive approach combining various strategies, including those discussed in this guide.

air filtration↗

Getting Beyond Widgets: Performance of Efficient Indoor Air Quality System Retrofit Packages for Schools A report on the modeled energy, greenhouse gas, and cost savings of several multi-measure retrofit packages for energy efficiency and indoor air quality in primary schools

School facilities are often underfunded with aging and poorly maintained HVAC and lighting systems. Most existing school buildings stand to benefit significantly from retrofits in terms of energy, cost, and emissions savings. Ventilation and indoor air quality (IAQ), which are important aspects of a healthy and productive learning environment, can also be enhanced by some energy efficiency measures (EEMs). Packaging energy efficiency and IAQ systems retrofits may represent a golden opportunity to improve performance in this critical building sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A review of antimicrobial implications for improving indoor air quality

The frequent outbreak of infectious respiratory diseases, such as the recent COVID-19 epidemic, raised the importance of indoor air quality. Removing microorganisms from indoor air is critical to improve indoor air quality. Numerous studies in recent years have been published on developing antimicrobial materials and technologies for antibacterial and antiviral applications. Further, this study critically reviews the recent antimicrobial advances for improving indoor air quality. This paper provides a comprehensive analysis of the antimicrobial mechanisms, development of materials, and deployment strategies, as well as a performance evaluation of the antimicrobial implication for indoor air quality. Furthermore, the challenges and opportunities of future research directions are also highlighted.

59 BASIC BIOLOGICAL SCIENCES↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

Indoor Air Quality (IAQ) Monitoring for Space Farming Institute [Slides]

Through the U.S. Department of Energy's Energy to Communities (E2C) program, NREL, other national laboratory experts, and select organizations provide Expert Match - free, short-term technical assistance to address near-term energy challenges and questions. Expert Match is for community stakeholders who have decision-making power or influence in their community but need access to additional energy expertise to inform key upcoming decisions. This Expert Match request supported the Space Farming Institute, a nonprofit organization located in Anchorage, AK, with an indoor air quality analysis. The NREL team analyzed indoor air quality data provided by the Space Farming Institute, which experts at PNNL used to design an indoor bioreactor to grow Ulva algae for indoor air quality mitigation purposes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pilot Study for Multifamily Building Ventilation and Indoor Air Quality

Weatherization Program Notice (WPN) 17-7 issued by the US Department of Energy (DOE) Weatherization Assistance Program (WAP) requires that buildings have ventilation in accordance with ASHRAE Standard 62.2-2016 (entitled Ventilation and Indoor Air Quality in Residential Buildings) in dwelling units weatherized under the program. The 2016 version of the standard expanded its scope of application to include all multifamily dwelling units. This has resulted in concerns for buildings where installing ventilation in individual units is costly or otherwise logistically difficult. Also, excessive ventilation rates could significantly increase energy costs, and may cause indoor air quality issues within the buildings. One deficiency that is noted is that the standard does not provide a credit for existing infiltration in multifamily buildings that reduces the required mechanical ventilation levels. This report details findings from a field study investigating envelope air-tightness, inter-unit connectivity, and indoor air quality in centrally ventilated high-rise multifamily buildings with central ventilation systems serving individual units in the state of New York. As allowed under WPN 17-7, the State of New York has a variance in the application of ASHRAE Standard 62.2-2016 in select types of multifamily buildings to provide time to determine how best to implement the standard. The purpose of this pilot study is to characterize the impact that weatherization and feasible ventilation improvements have on the indoor air quality of large, multifamily buildings with centrally ventilated apartments, as currently performed under WAP in the State of New York under their variance request (i.e., to implement ASHRAE Standard 62.2-2016 “to the greatest extent possible” in this type of multifamily building). A major goal is to determine if these practices improve or at least “do no harm” to the indoor air quality of the weatherized multifamily buildings and to the occupants themselves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of a Smart Energy Recovery Ventilation System Using Low-Cost Indoor Air Quality Sensors

This project is a field validation, using low-cost indoor air quality (IAQ) sensors, of a smart ventilation system that can help low-load homes in humid environments maintain acceptable indoor humidity conditions while providing adequate ventilation according to ASHRAE 62.2. The objectives of this research were to (1) address builders’ concerns with mechanical ventilation in humid environments and (2) answer the question of whether smart control logic helps with occupant comfort and the creation of a more acceptable indoor environment. To address the objectives of the study, the Southface team collected field data for one year in four Charleston, South Carolina, new construction homes in order to determine the differences in occupant comfort; comfort metrics; IAQ; and heating, ventilating, and air-conditioning (HVAC) energy consumption when toggling biweekly between an energy recovery ventilator (ERV) operating continuously and an ERV operating with smart, time-varying humidity control logic. The smart ventilation algorithm under consideration in this field test did create a less humid indoor environment on an annual basis as quantitatively measured through temperature and relative humidity (T/RH) readings, expressed most discernably as “percentage of time above 60% RH” and “percentage of time above 55°F dewpoint.” However, the difference it made was inconsistent during the spring, summer, and fall months, and it was only directionally consistent during the winter months. We suspect that this is primarily due to the long runtimes and concomitant dehumidification activity of the air-conditioning (A/C) units in response to the high sensible loads in Charleston. The effect of the smart ventilation algorithm was not discernable to the occupants in this study, as recorded through seasonal surveys.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Laboratory Test Methods for Low-Cost Indoor Air Quality Sensors

This report describes the development of two standard test methods: one for evaluating PM2.5 sensors; and the other for evaluating CO 2 Sensors. The standards were developed to provide a pathway for the use of reliable, low-cost indoor air quality sensors as occupant feedback, ventilation control, and overall indoor air quality improvement. This paper describes the development process and technical issues involved.

30 DIRECT ENERGY CONVERSION↗

Tradeoffs among indoor air quality, financial costs, and CO 2 emissions for HVAC operation strategies to mitigate indoor virus in U.S. office buildings

Adapting building operation during the COVID-19 pandemic to improve indoor air quality (IAQ) while ensuring sustainable solutions in terms of costs and CO 2 emissions is challenging and limited in literature. Our previous study investigated different HVAC operation strategies, including increased filtration using MERV 10, MERV 13, or HEPA filters, as well as supplying 100% outdoor air into buildings for a system initially sized for MERV 10 filtration. This paper significantly extends that research by systematically analyzing the potential financial and environmental impact for different locations in the U.S. The previous medium office building system model is improved to account for operation in different climates. New evaluation metrics are created to consider the comprehensive impact of improving IAQ on costs and CO 2 emissions, using dynamic emission factors for electricity generation depending on the location. HVAC operation strategies are studied in five different locations across the United States, with distinct climates and electricity sources. In four of the five locations, MERV 13 filtration offers the best improvement in IAQ per increase in costs and emissions relative to MERV 10. The exception is the mildest climate of San Diego, where use of 100% outdoor air provides the best IAQ with a limited increase in costs and emissions. Finally, a system not sized for HEPA filtration can lead to increased costs and emissions without much improvement in IAQ.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ten questions concerning low-cost indoor air quality sensors: Perspectives from research and practice

Low-cost indoor air quality (IAQ) sensors are increasingly being used in homes and commercial and public buildings, driven by growing concerns about the impact of air on health, cognitive performance, and occupant wellbeing. These sensors offer a potentially transformative opportunity to increase spatial and temporal coverage of IAQ monitoring at a fraction of the cost of conventional reference instruments. However, their widespread use raises questions around accuracy, calibration, placement, data handling and interpretation, and integration into existing standards and workflows. This paper presents ten critical questions concerning the use of low-cost IAQ sensors in buildings, drawing on the latest empirical research, field deployments, and emerging practice. It discusses potential frameworks for deployment and evaluation, examines current sensor capabilities for measuring common pollutants, identifies methodological gaps in validation and uncertainty quantification, and outlines the extent to which existing IAQ standards can accommodate sensor-based evidence. The paper also explores how monitoring needs and deployment models vary by building type, the potential of real-time IAQ data to support building operations, and the ethical and legal implications of widespread sensor use. While significant challenges remain in ensuring data quality and building stakeholder trust, new applications are emerging through open data initiatives and advances in analytics and visualization. As the technology, science, and standards co-evolve, low-cost IAQ sensors are poised to become integral to routine building operation, building science, and environmental health research.

Parkinson, Thomas↗

An Unobstructive Sensing Method for Indoor Air Quality Optimization and Metabolic Assessment within Vehicles

This work investigates the use of an intelligent and unobstructive sensing technique for maintaining vehicle cabin’s indoor air quality while simultaneously assessing the driver metabolic rate. CO 2 accumulation patterns are of great interest because CO 2 can have negative cognitive effects at higher concentrations and also since CO 2 accumulation rate can potentially be used to determine a person’s metabolic rate. The management of the vehicle’s ventilation system was controlled by periodically alternating the air recirculation mode within the cabin, which was actuated based on the CO 2 levels inside the vehicle’s cabin. The CO 2 accumulation periods were used to assess the driver’s metabolic rate, using a model that considered the vehicle’s air exchange rate. In the process of the method optimization, it was found that the vehicle’s air exchange rate (λ [h –1 ]) depends on the vehicle speeds, following the relationship: λ = 0.060 × (speed) – 0.88 when driving faster than 17 MPH. An accuracy level of 95% was found between the new method to assess the driver’s metabolic rate (1620 ± 140 kcal/day) and the reference method of indirect calorimetry (1550 ± 150 kcal/day) for a total of N = 16 metabolic assessments at various vehicle speeds. The new sensing method represents a novel approach for unobstructive assessment of driver metabolic rate while maintaining indoor air quality within the vehicle cabin.

passive sensing↗

Thermal and photoinduced chemistry of the aromatic Criegee intermediate, benzaldehyde oxide: Implications for indoor air quality

Essential oils contain a complex mixture of volatile organic compounds, ranging from terpenes to aromatics. When released into the indoor air environment or into the atmosphere, they may undergo oxidation to generate complex reactive intermediates that affect indoor air quality. Cinnamaldehyde is one such aromatic molecule that is abundant in essential oils. When released into the indoor air environment, it may undergo oxidation to form a carbonyl oxide (Criegee intermediate) with an aromatic substituent: benzaldehyde oxide. In this manuscript, we present a high-level quantum chemical study that shows that, unlike smaller atmospherically relevant Criegee intermediates, benzaldehyde oxide is expected to undergo solar photolysis on timescales that are competitive with its ground state unimolecular and bimolecular chemistry. We show that aromatic substitution leads to a drastic bathochromic shift in the spectroscopically relevant excited states, revealing that photolysis in the indoor or outdoor environment should not be neglected when modeling the climate and air quality implications of Criegee intermediates with extended conjugation. Here, we predict a range of products that may be important for forming lower volatility compounds via tropospherically relevant photochemistry. To motivate future experimental validation of our results, we propose a viable synthetic procedure of the relevant precursor for generating and stabilizing benzaldehyde oxide.

atmospheric photochemistry↗

Reinforcement Learning Control for Buildings Co-Optimizing Energy, Comfort, and Indoor Air Quality: An Annual Assessment

Efficient control of Heating, Ventilation, and Air Conditioning (HVAC) systems is crucial for optimizing energy use and maintaining indoor comfort in buildings. Traditional control methods, such as PID control, cannot handle energy use trade-offs among multiple components in the building energy system at a supervisory level. Reinforcement learning (RL) presents a promising solution, offering adaptive and data-driven control strategies that optimize performance over time. However, RL also faces several challenges, including the conflicts encountered in co-optimizing energy savings, occupant comfort, and indoor air quality, and the requirement for extensive interactions with the environment in training. We proposed a flexible simulation platform that integrates a hybrid model for RL training and designed an RL agent to control the entire central HVAC system, focusing on co-optimizing energy consumption, thermal comfort, and indoor air quality ($\text{CO}_{2}$ and PM2.5 concentrations). Finally, we evaluated the RL agent's performance over an annual cycle. Our findings indicate that the RL agent can effectively manage the HVAC system with 14.7 % energy savings annually and balance multiple objectives, which demonstrates significant potential for improving HVAC system control and sustainability in buildings.

Guo, Fangzhou↗

Multitarget control models for building thermal comfort and indoor air quality - A critical review

The control techniques in buildings contribute significantly to thermal comfort and indoor air quality (IAQ). However, the gaps are existing for multitarget controls considering both thermal comfort and IAQ. They are: (1) both experimental and modeling control studies were conducted for thermal comfort, focusing on temperature and humidity. (2) All three (physical, grey-box, black-box) modeling approaches were investigated for temperature control. (3) Physical and grey-box modeling approach were adopted for humidity control. (4) physical models were developed for VOCs and CO2 control. (5) grey-box and black-box models were lacking for VOCs and CO2. (6) Multi-target controls were lacking for temperature, humidity and CO2s. (7) Limited studies are available for multi-target controls for temperature, humidity, and VOCs. (8) Multi-target controls are not available yet for temperature, humidity, VOCs, and CO2.

42 ENGINEERING↗

Deep reinforcement learning control for co-optimizing energy consumption, thermal comfort, and indoor air quality in an office building

With the recent demand for decarbonization and energy efficiency, advanced HVAC control using Deep Reinforcement Learning (DRL) becomes a promising solution. Due to its flexible structures, DRL has been successful in energy reduction for many HVAC systems. However, only a few researches applied DRL agents to manage the entire central HVAC system and control multiple components in both the water loop and the air loop, owing to its complex system structures. Moreover, those researches have not extended their applications by incorporating the indoor air quality, especially both CO2 and PM2.5concentrations, on top of energy saving and thermal comfort, as achieving those objectives simultaneously can cause multiple control conflicts. What's more, DRL agents are usually trained on the simulation environment before deployment, so another challenge is to develop an accurate but relatively simple simulator. Therefore, we propose a DRL algorithm for a central HVAC system to co-optimize energy consumption, thermal comfort, indoor CO2 level, and indoor PM2.5 level in an office building. To train the controller, we also developed a hybrid simulator that decoupled the complex system into multiple simulation models, which are calibrated separately using laboratory test data. The hybrid simulator combined the dynamics of the HVAC system, the building envelope, as well as moisture, CO2, and particulate matter transfer. Three control algorithms (rule-based, MPC, and DRL) are developed, and their performances are evaluated on the hybrid simulator environment with a realistic scenario (i.e., with stochastic noises). The test results showed that, the DRL controller can save 21.4 % of energy compared to a rule-based controller, and has improved thermal comfort, reduced indoor CO2 concentration. The MPC controller showed an 18.6 % energy saving compared to the DRL controller, mainly due to savings from comfort and indoor air quality boundary violations caused by unmeasured disturbances, and it also highlights computational challenges in real-time control due to non-linear optimization. Finally, we provide the practical considerations for designing and implementing the DRL and MPC controllers based on their respective pros and cons.

Guo, Fangzhou↗

Mechanical Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes in Marine and Cold-Dry Climates Data from Building America Project

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO2, PM2.5 and radon; and time-integrated NO2, NOX and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2-2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO2, and NO (NOX-NO2) when operated with WHMV; and also had faster PM2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19 vs. 3%) felt their IAQ could be improved and more reported dryness as a problem (58 vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

air quality↗

Mechanical ventilation and indoor air quality in recently constructed U.S. homes in marine and cold-dry climates

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and the Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO 2 , PM2.5 and radon; and time-integrated NO 2 , NO X and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2–2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO 2 and NO (NO X -NO 2 ) when operated with WHMV, and had faster PM 2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19% vs 3%) felt their IAQ could be improved and more reported dryness as a problem (58% vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗