Search NASA⌕ Search

SEARCH · Search NASA

Results for “Indoor environmental”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigating the influence of environmental information on perceived indoor environmental quality: An exploratory study

Under the assumption that information can impact perception, most research on human sensation and satisfaction with indoor environmental quality (IEQ) parameters has been conducted with respondents uninformed about the test conditions. Therefore, researchers know little about the impact of information on perception. These potential effects are increasingly relevant as quantitative information about indoor environments becomes accessible via low-cost, wirelessly connected sensors. In this experimental study, 48 subjects were exposed to varied indoor environmental conditions and provided with different types of environmental information. The subjects' sensation and satisfaction were compared when they were blinded or provided with quantitative information about and/or qualitative ratings of specific parameters. The results indicate that accurate information on parameter values influenced how the subjects perceived the indoor air quality (IAQ) but not how they perceived the thermal, acoustic, or visual quality. The subjects rated the IAQ more positively when they were informed that there were nonzero ventilation rates. The qualitative ratings influenced the subjects' perceptions of all four environmental factors, but in different directions. The subjects generally had more positive sensation and higher satisfaction when they were told that the parameter values and qualitative ratings were more favorable than the test conditions. However, the improved sensation and satisfaction were often not as good as when the environmental conditions were actually improved and the subjects were provided with accurate information. Here, these findings affirm the critical need for more research on the impacts of information on perceptions of the indoor environment.

42 ENGINEERING↗

Post-occupancy evaluation of indoor environmental quality in ten nonresidential buildings in Chongqing, China

Indoor environmental quality (IEQ) is an essential element of sustainable building performance. To advance knowledge of indoor environmental quality in Chinese nonresidential buildings, this study conducted post-occupancy evaluation (POE) in varied use areas within schools, hospitals, offices, hotels and shopping malls through environmental measurements and occupant surveys in 10 buildings over four seasons in Chongqing, China. Measured thermal conditions were more frequently within comfort standards in winter than in summer according to the predicted mean vote – predicted percentage dissatisfied model; but the model did not reliably predict thermal satisfaction. There was insufficient illuminance in 28% of studied areas and high illuminance in shopping malls led to complaints about glare. Sound pressure exceeded the Chinese guideline in all buildings with shopping malls having significantly higher levels than other buildings. CO 2 was generally below the Chinese national guideline of 1000 ppm; the two percent of measurements that exceeded the guideline occurred in classrooms, hospital wards and underground supermarkets. Formaldehyde did not exceed the limit level of 0.1 mg/m3 in any space. Most of the buildings did not provide effective protection from outdoor fine particulate matter (PM2.5), and infiltration from outdoors was the main factor for exceeding health-based guidelines indoors. Shopping malls had lower IEQ satisfaction than offices, schools and hospitals. Sound was the factor with the lowest satisfaction level among the four principal environmental factors. Overall, this study demonstrates value of POE on identifying deficiencies in indoor environment and provides a reference for assessment of IEQ in nonresidential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatial and temporal variations in indoor environmental conditions, human occupancy, and operational characteristics in a new hospital building

The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogate measures for human occupancy and activity in the patient rooms using both indoor air CO₂ concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10⁶ data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.

54 ENVIRONMENTAL SCIENCES↗

Meta‐Analysis and Regression Modeling of the Impacts of Four Indoor Environmental Quality Metrics on Office Performance

Awareness of how buildings interact with the occupant experience—especially human performance—is becoming more prevalent, as seen by increasing interest and investment in healthy built environments. However, there is a need to synthesize the wide array of existing indoor environmental assessment and performance research in a way that can translate directly to building design and operation. Existing research in this area typically focuses on a single isolated metric and has not focused on making the results utilizable by building practitioners. The aim of this research is to investigate existing office performance literature through meta‐analyses and produce regression models for four indoor environmental quality (IEQ) metrics to support critical decision‐making for building operation and renovation. To reach this aim, a literature review was conducted to identify studies that measure the impact of changing ventilation rate, temperature, horizontal illuminance, and noise level in offices on occupant task performance. This repository of field and laboratory studies was analyzed to visualize the trends between the selected IEQ metrics and task performance. The temperature, ventilation rate, and horizontal illuminance regression models showed clear improvement potential when modifying indoor conditions toward the defined high‐performance range, while the regression model for noise level was inconclusive. The discussion notes the importance of designing holistically for all components of these IEQ categories to utilize the results, for example, good filtration on outdoor air for quantifying ventilation impact and uniform overhead lighting with low contrast for quantifying horizontal illuminance impact. The novelty of this work is in considering multiple facets of the indoor environment under a single, unified analysis schema and producing IEQ‐based performance gains that can directly inform cost‐benefit analyses of building design and renovation.

60 APPLIED LIFE SCIENCES↗

A Review of the Use of Wearables in Indoor Environmental Quality Studies and an Evaluation of Data Accessibility from a Wearable Device

An understanding of indoor environmental quality (IEQ) and its effects on occupant well-being can inform building system design and operation. The use of wearables in field studies to collect subjective and objective health performance indicators (HPIs) from a large number of occupants could deliver important improvements in IEQ. To facilitate the use of wearables in IEQ studies, there is a need to identify which HPIs should be collected and to evaluate data accessibility from these devices. To address this issue, a literature review of previous IEQ studies was conducted to identify relationships between different IEQ factors and HPIs, with a focus on HPIs that were collected using wearables. A preliminary assessment of data accessibility from a selected wearable device (Fitbit Versa 2) was performed and documented. The review suggested the need to further investigate and collect sleep quality parameters, heart rate, stress response, as well as subjective ratings of comfort using wearables. The data accessibility assessment revealed issues related to missing data points and data resolution from the examined device. A set of recommendations is outlined to inform future studies.

60 APPLIED LIFE SCIENCES↗

Protocol for maximizing energy savings and indoor environmental quality improvements when retrofitting apartments

The current focus on building energy retrofit provides an opportunity to simultaneously improve indoor environmental quality (IEQ). Toward this end, we developed a protocol for selecting packages of retrofits that both save energy and improve IEQ in apartments. The protocol specifies the methodology for selecting retrofits from a candidate list while addressing expected energy savings, IEQ impacts, and costs in an integrated manner. Interviews, inspections and measurements are specified to collect the needed input information. The protocol was applied to 17 apartments in three buildings in two different climates within California. Diagnostic measurements and surveys conducted before and after retrofit implementation indicate enhanced apartment performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Protocol for Maximizing Energy Savings and Indoor Environmental Quality Improvements when Retrofiting Apartments

The current focus on building energy retrofit provides an opportunity to simultaneously improve indoor environmental quality (IEQ). Toward this end, we developed a protocol for selecting packages of retrofits that both save energy and improve IEQ in apartments. The protocol specifies the methodology for selecting retrofits from a candidate list while addressing expected energy savings, IEQ impacts, and costs in an integrated manner. Interviews, inspections and measurements are specified to collect the needed input information. The protocol was applied to 17 apartments in three buildings in two different climates within California. Diagnostic measurements and surveys conducted before and after retrofit implementation indicate enhanced apartment performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Field-Testing of a Study Protocol, including a Web-Based Occupant Survey Tool, for Use in Intervention Studies of Indoor Environmental Quality

We developed and pilot-tested an overall protocol for intervention studies to evaluate the effects of indoor environmental changes in office buildings on the health symptoms and comfort of occupants. The protocol includes a web-based survey to assess the occupant's responses, as well as specific features of study design and analysis. The pilot study, carried out on two similar floors in a single building, compared two types of ventilation system filter media. With support from the building's Facilities staff, the implementation of the filter change intervention went well. While the web-based survey tool worked well also, low overall response rates (21-34percent among the three work groups included) limited our ability to evaluate the filter intervention., The total number of questionnaires returned was low even though we extended the study from eight to ten weeks. Because another simultaneous study we conducted elsewhere using the same survey had a high response rate (>70percent), we conclude that the low response here resulted from issues specific to this pilot, including unexpected restrictions by some employing agencies on communication with occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Association of residential energy efficiency retrofits with indoor environmental quality, comfort, and health: A review of empirical data

This paper reviews empirical data from evaluations of the influence of residential energy efficiency retrofits on indoor environmental quality conditions and self-reported thermal comfort and health. The data were extracted from 36 studies described in 44 papers plus two reports. Nearly all reviewed studies were performed in Europe or United States. Most studies evaluated retrofits of homes with low-income occupants. Indoor radon and formaldehyde concentrations tended to increase after retrofits that did not add whole-house mechanical ventilation. Study-average indoor concentrations of nitrogen dioxide and volatile organic compounds other than formaldehyde increased and decreased with approximately equal frequency. Average indoor temperatures during winter typically increased after retrofits, usually by less than 1.5 °C. Dampness and mold, usually based on occupant's reports, almost always decreased after retrofits. Subjectively reported thermal comfort, thermal discomfort, non-asthma respiratory symptoms, general health, and mental health nearly always improved after retrofits. For asthma symptoms, the evidence of improvement slightly outweighed the evidence of worsening. There was insufficient evidence to determine whether changes in thermal comfort and health outcomes varied depending on the type of energy efficiency retrofit. The published research has numerous limitations including a lack of data from retrofits in warm-humid climates and minimal data on changes in objective health outcomes. Suggestions for future research are provided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Indoor Environmental Quality Benefits of Apartment Energy Retrofits

Sixteen apartments serving low-income populations in three buildings were retrofit with the goal of simultaneously reducing energy consumption and improving indoor environmental quality (IEQ). Retrofit measures varied among apartments and included, among others, envelope sealing, installation of continuous mechanical ventilation systems, upgrading bathroom fans and range hoods, attic insulation, replacement of heating and cooling systems, and adding wall-mounted particle air cleaners. IEQ parameters were measured, generally for two one-week periods before and after the retrofits. The measurements indicate an overall improvement in IEQ conditions after the retrofits. Comfort conditions, bathroom humidity, and concentrations of carbon dioxide, acetaldehyde, volatile organic compounds, and particles generally improved. Formaldehyde and nitrogen dioxide levels decreased in the building with the highest concentrations, were unchanged in a second building, and increased in a third building. IEQ parameters other than particles improved more in apartments with continuous mechanical ventilation systems installed. In general, but not consistently, larger percent increases in air exchange rates were associated with larger percent decreases in indoor levels of the pollutants that primarily come from indoor sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency and Indoor Environmental Quality Assessment Guide

This report provides thorough guidance when preparing for an energy and indoor environmental quality (IEQ) assessment. It includes step-by-step instructions, detailed insights, and practical examples for the various phases of an energy and IEQ assessment. IEQ encompasses indoor building conditions—such as air quality, thermal comfort, acoustics, and lighting— and is a growing field of interest among a diverse range of stakeholders (e.g., building owners and managers) due to the effects it has on occupant health and productivity. IEQ improvement strategies often provide overlapping opportunities for increasing building energy efficiency, creating a win-win situation for building operations.

Esaki-Kua, Lauren↗

Indoor Environmental Exposures and Exacerbation of Asthma: An Update to the 2000 Review by the Institute of Medicine

Background: Previous research has found relationships between specific indoor environmental exposures and exacerbation of asthma. Objectives: In this review we provide an updated summary of knowledge from the scientific literature on indoor exposures and exacerbation of asthma. Methods: Peer-reviewed articles published from 2000 to 2013 on indoor exposures and exacerbation of asthma were identified through PubMed, from reference lists, and from authors’ files. Articles that focused on modifiable indoor exposures in relation to frequency or severity of exacerbation of asthma were selected for review. Research findings were reviewed and summarized with consideration of the strength of the evidence. Results: Sixty-nine eligible articles were included. Major changed conclusions include a causal relationship with exacerbation for indoor dampness or dampness-related agents (in children); associations with exacerbation for dampness or dampness-related agents (in adults), endotoxin, and environmental tobacco smoke (in preschool children); and limited or suggestive evidence for association with exacerbation for indoor culturable Penicillium or total fungi, nitrogen dioxide, rodents (nonoccupational), feather/down pillows (protective relative to synthetic bedding), and (regardless of specific sensitization) dust mite, cockroach, dog, and dampness-related agents. Discussion: This review, incorporating evidence reported since 2000, increases the strength of evidence linking many indoor factors to the exacerbation of asthma. Conclusions should be considered provisional until all available evidence is examined more thoroughly. Conclusion: Multiple indoor exposures, especially dampness-related agents, merit increased attention to prevent exacerbation of asthma, possibly even in nonsensitized individuals. Additional research to establish causality and evaluate interventions is needed for these and other indoor exposures.

60 APPLIED LIFE SCIENCES↗

Making the Most Out of an Indoor Environmental Quality Assessment

This document is for federal agencies, building owners, and building managers and operators who are considering conducting indoor environmental quality (IEQ)assessments at their facilities. The following information explains what value IEQ assessments can provide and how to plan for one.

Ackerman, Allison↗

The health and indoor environmental quality impacts of residential building envelope retrofits: A literature review

Retrofitting existing buildings to improve energy efficiency is an important strategy to meet increasingly stringent energy efficiency targets. While the primary objective of energy efficiency retrofits is to reduce energy consumption and greenhouse gas emissions, retrofits can also result in non-energy impacts (NEIs), which contribute to decision-making processes and overall value of the retrofit. NEIs have been studied extensively in retrofitted residential buildings; however, these studies have historically grouped passive (i.e., building envelope) and active (i.e., heating, ventilation, and air conditioning (HVAC) and energy system) upgrades, making it difficult to identify the underlying mechanism(s) of action for each NEI and developing effective retrofit strategies, based on occupant need. The purpose of this study was to better account for NEIs, based on a literature review, summarizing the current state of knowledge on NEIs associated with residential building envelope retrofits. We limited our search to health- and indoor environmental quality-related NEIs. The review identified strong evidence that building envelope retrofits improve acoustic comfort, wintertime thermal comfort, and respiratory and cardiovascular health outcomes. IAQ outcomes were mixed, with studies reporting both increases and decreases to indoor contaminant concentrations following retrofits. The strength of the effect was generally governed by pre-retrofit contaminant concentrations and whether indoor concentrations were dominated by indoor or outdoor sources. Most studies evaluating summertime thermal comfort identified increased incidence of summertime overheating; however, none of these studies linked the change in thermal conditions to health outcomes. Recommendations for future work include expanding studies to include more market rate housing and the health impacts of summertime overheating in retrofitted buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FEMP Energy Efficiency and Indoor Environmental Quality Assessment Guide

The purpose of this document is to provide a thorough guidance when preparing for an energy and indoor environmental quality (IEQ) assessment. It provides step-by-step instructions, detailed insights, and practical examples for the various phases of an energy and IEQ assessment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Statistical Analysis and Interpretation of Building Characterization, Indoor Environmental Quality Monitoring and Energy Usage Data from Office Buildings and Classrooms in the United States

Three independent tasks had been performed (Stetzenbach 2008, Stetzenbach 2008b, Stetzenbach 2009) to measure a variety of parameters in normative buildings across the United States. For each of these tasks 10 buildings were selected as normative indoor environments. Task 1 focused on office buildings, Task 13 focused on public schools, and Task 0606 focused on high performance buildings. To perform this task it was necessary to restructure the database for the Indoor Environmental Quality (IEQ) data and the Sound measurement as several issues were identified and resolved prior to and during the transfer of these data sets into SPSS. During overview discussions with the statistician utilized in this task it was determined that because the selection of indoor zones (1-6) was independently selected within each task; zones were not related by location across tasks. Therefore, no comparison would be valid across zones for the 30 buildings so the by location (zone) data were limited to three analysis sets of the buildings within each task. In addition, differences in collection procedures for lighting were used in Task 0606 as compared to Tasks 01 & 13 to improve sample collection. Therefore, these data sets could not be merged and compared so effects by-day data were run separately for Task 0606 and only Task 01 & 13 data were merged. Results of the statistical analysis of the IEQ parameters show statistically significant differences were found among days and zones for all tasks, although no differences were found by-day for Draft Rate data from Task 0606 (p>0.05). Thursday measurements of IEQ parameters were significantly different from Tuesday, and most Wednesday measures for all variables of Tasks 1 & 13. Data for all three days appeared to vary for Operative Temperature, whereas only Tuesday and Thursday differed for Draft Rate 1m. Although no Draft Rate measures within Task 0606 were found to significantly differ by-day, Temperature measurements for Tuesday and Thursday showed variation. Moreover, Wednesday measurements of Relative Humidity within Task 0606 varied significantly from either Tuesday or Thursday. The majority of differences in IEQ measurements by-zone were highly significant (p<0.001), with the exception of Relative Humidity in some buildings. When all task data were combined (30 buildings) neither the airborne culturable fungi nor the airborne non-culturable spore data differed in the concentrations found at any indoor location in terms of day of collection. However, the concentrations of surface-associated fungi varied among the day of collection. Specifically, there was a lower concentration of mold on Tuesday than on Wednesday, for all tasks combined. As expected, variation was found in the concentrations of both airborne culturable fungi and airborne non-culturable fungal spores between indoor zones (1-6) and the outdoor zone (zone 0). No variation was found among the indoor zones of office buildings for Task 1 in the concentrations of airborne culturable fungi. However, airborne non-culturable spores did vary among zones in one building in Task 1 and variation was noted between zones in surface-associated fungi. Due to the lack of multiple lighting measurements for Tasks 13 and 0606, by-day comparisons were only performed for Task 1. No statistical differences were observed in lighting with respect to the day of collection. There was a wide range of variability by-zone among seven of the office buildings. Although few differences were found for the brightest illumination of the worksurface (IllumWkSfcBrtst) and the darkest illumination of the worksurface (IllumWkSfcDrkst) in Task 1, there was considerable variation for these variables in Task 13 and Task 0606 (p < 0.001). Other variables that differed by-zone in Task 13 include CombCCT and AmbCCT1 for S03, S07, and S08. Additionally, AmbChromX1, CombChromY, and CombChromX varied by-zone for school buildings S02, S04, and S05, respectively. Although all tasks demonstrated significant differences in sound measurements by zone, some of the buildings within each task did not appear to differ in sound quality. Hence, post-hoc tests were not appropriate and individual zones were not compared for these buildings. It is interesting to note that sound measurements in some buildings were widely varied with most zone comparisons and other buildings varied between only a few zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Impacts of Energy and Indoor Environmental Quality Retrofits of Apartments in California

Monthly gas and electricity use data from a set of 13 study apartments and 20 control apartments from three apartment buildings (B1 B3) in California were analyzed. The study apartments were retrofit with simultaneous energy savings and indoor environmental quality (IEQ) improvements as the goal. The control apartments were not retrofit. Pre-retrofit modeling indicated annual energy savings of 21percent, 17percent, and 27percent for the study apartments in B1-B3, respectively. Based on a comparison of changes in energy use of study apartments to energy use changes of control apartments, total measured savings of gas energy plus site electrical energy were 28percent in B1, 5percent in B2, and 3percent in B3. Given the small number of study apartments and the substantial changes in energy use within control apartments, the project yielded no conclusive evidence of energy savings. Apartment energy use increased with number of occupants and with floor area; however, the association with occupancy was most evident. Climate differences did not appear to be the major driver for the variability in energy use among apartments. Changes in occupant behaviors affecting energy use may have overwhelmed and obscured the energy savings in this small number of buildings. Much larger prior studies employing similar retrofits indicate that the retrofits usually do save energy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An inverse approach to solving zone air infiltration rate and people count using indoor environmental sensor data

Physics-based simulation of energy use in buildings is typically widely used in building design and performance rating, controls design and operations. However, various challenges exist in the modeling process. Model parameters such as people count and air infiltration rate are usually highly uncertain, yet they have significant impacts on the simulation accuracy. With the increasing availability and affordability of sensors and meters in buildings, a large amount of measured data has been collected including indoor environmental parameters, such as room air dry-bulb temperature, humidity ratio, and CO 2 concentration levels. Fusing these sensor data with traditional energy modeling poses new opportunities to improve simulation accuracy. This study develops a set of physics-based inverse algorithms which can solve the highly uncertain and hard-to-measure building parameters such as zone-level people count and air infiltration rate. A simulation-based case study is conducted to verify the inverse algorithms implemented in EnergyPlus covering various sensor measurement scenarios and different modeling use cases. The developed inverse models can solve the zone people count and air infiltration at sub-hourly resolution using the measured zone air temperature, humidity and/or CO 2 concentration given other easy-to-measure model parameters are known.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗