Current-induced CrI 3 surface spin-flop transition probed by proximity magnetoresistance in Pt
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
The Mott insulator Ca 2 RuO 4 exhibits an insulator-to-metal transition induced by d.c. current. Despite the thorough examination of the structural changes associated with this transition, a comprehensive knowledge of the response of electronic degrees of freedom is still lacking. Here we demonstrate current-induced modifications of the electronic states of Ca 2 RuO 4 . Angle-resolved photoemission spectroscopy in conjunction with four-probe electrical transport (transport-ARPES) measurements reveal a clear reduction of the Mott gap and a modification in the dispersion of the Ru bands. Based on a free-energy analysis, we show that the current-induced phase is electronically distinct from the high-temperature zero-current metallic phase. Our results highlight strong interplay of lattice- and orbital-dependent electronic responses in the current-driven insulator-to-metal transition.
Current–induced spin–orbit torques (SOTs) have emerged as a powerful tool to control magnetic elements and non–uniform magnetic textures such as domain walls and skyrmions. SOT–induced switching of perpendicular magnetization generally requires an external field to break the rotational symmetry of the spin–orbit effective fields responsible for the deterministic reversal. The proposed mechanisms to eliminate this requirement often rely on complex multilayer structures that necessitate laborious optimization in the material and spin transport properties, making them less attractive for applications. Herein, current–induced, external field–free switching of an epitaxial MgO/Pt/Co trilayer with an extremely large perpendicular anisotropy in excess of 3 Tesla is reported. It is found that switching occurs due to the interplay of strong SOTs, local anisotropy fluctuations, and the Dzyaloshinkii–Moriya interaction inherent to this epitaxial system. Finally, given that these layers constitute the base stack of a magnetic tunnel junction, this switching mechanism offers the most technologically viable path toward devices such as field–free SOT–based magnetic random–access memories.
Geomagnetically-induced current (GIC) due to space weather can flow in the power grid causing undesirable effects such as transformer overheating, misoperation of protection devices, and potential blackouts. It is therefore important to monitor GIC in the power grid to improve online situational awareness and decision-making of system operators during a geomagnetic disturbance. To avoid the costly installation of GIC monitors at transformers’ neutrals, it is desirable to find correlations between GIC and already-monitored parameters. Hence, this work proposed the use of a convolutional neural network (CNN) to compute GIC amplitudes from learned patterns in the time-series data of transformer even harmonic currents. Using an electromagnetic transient program, GIC injection simulations were performed for a modeled Dominion Energy Virginia (DEV) substation with two 504 MVA, 500/230 kV transformers. Data collected from these offline simulations were used to train the CNN to provide online GIC monitoring. Testing the CNN performance involved using real GIC measurements from published literature and from a physical GIC monitor in the DEV area. Finally, the results showed that the proposed method was able to provide GIC readings with a root mean squared error of 1.56 A/phase (equivalent to an average accuracy of 94%) for these real GIC waveforms.
The remanent magnetization of ferromagnets has long been studied and used to store binary information. While early magnetic memory designs relied on magnetization switching by locally generated magnetic fields, key insights in condensed matter physics later suggested the possibility of doing it by electrical means instead. In the 1990s, Slonczewski and Berger formulated the concept of current-induced spin torques in magnetic multilayers through which a spin-polarized current generated by a first ferromagnet may be used to switch the magnetization of a second one. This discovery drove the development of spin-transfer-torque magnetic random-access memories (MRAMs). More recent fundamental research revealed other types of current-induced torques named spin-orbit torques (SOTs) and will lead to a new generation of devices including SOT MRAMs and skyrmion-based devices. Parallel to these advances, multiferroics and their magnetoelectric coupling, first investigated experimentally in the 1960s, experienced a renaissance. Dozens of multiferroic compounds with new magnetoelectric coupling mechanisms were discovered and high-quality multiferroic films were synthesized (notably of BiFeO 3 ), also leading to novel device concepts for information and communication technology such as the magnetoelectric spin-orbit (MESO) transistor. The story of the electrical switching of magnetization, which is discussed in this review, is that of a dance between fundamental research (in spintronics, condensed matter physics, and materials science) and technology (MRAMs, MESO transistors, microwave emitters, spin diodes, skyrmion-based devices, components for neuromorphics, etc.). This pas de deux has led to major scientific and technological breakthroughs in recent decades (such as the conceptualization of pure spin currents, the observation of magnetic skyrmions, and the discovery of spin-charge interconversion effects). As a result, this field has not only propelled MRAMs into consumer electronics products but also fueled discoveries in adjacent research areas such as ferroelectrics or magnonics. Here, in this review, recent advances in the control of magnetism by electric fields and by current-induced torques are covered. Fundamental concepts in these two directions are reviewed first, their combination is then discussed, and finally current various families of devices harnessing the electrical control of magnetic properties for various application fields are addressed. The review concludes by giving perspectives in terms of both emerging fundamental physics concepts and new directions in materials science.
We consider magnetic Weyl metals as a platform to achieve current control of magnetization textures with transport currents utilizing their underlying band geometry. We show that the transport current in a Weyl semimetal produces an axial magnetization due to orbital magnetic moments of the Weyl electrons. The associated axial magnetization can generate a torque acting on the localized magnetic moments. For the case of a magnetic vortex in a nanodisk of Weyl materials, this current-induced torque can be used to reverse its circulation and polarity. We discuss the axial magnetization torques in Weyl metals on general symmetry grounds and compare their strength to current-induced torques in more conventional materials.
Abstract Over the last few years, a new mode for imaging in the scanning transmission electron microscope (STEM) has gained attention as it permits the direct visualization of sample conductivity and electrical connectivity. When the electron beam (e-beam) is focused on the sample in the STEM, secondary electrons (SEs) are generated. If the sample is conductive and electrically connected to an amplifier, the SE current can be measured as a function of the e-beam position. This scenario is similar to the better-known scanning electron microscopy-based technique, electron beam-induced current imaging, except that the signal in the STEM is generated by the emission of SEs, hence the name secondary electron e-beam-induced current (SEEBIC), and in this case, the current flows in the opposite direction. Here, we provide a brief review of recent work in this area, examine the various contrast generation mechanisms associated with SEEBIC, and illustrate its use for the characterization of graphene nanoribbon devices.
Electron beam-induced current (EBIC) imaging is a well-established scanning electron microscope (SEM) technique used to analyze the behavior of microelectronic devices including solar cells. Recently, the application of EBIC imaging in an aberration-corrected scanning transmission electron microscope (STEM) has been demonstrated and offers great potential for the in situ study of electronic materials, correlating charge transport properties to atomic structural and elemental information. Here, this work presents two ways to implement EBIC imaging in conventional SEM and STEM systems: one relying on the instrument's inherent scanning and imaging electronics and the other involving third-party systems usually available in electron microscopes. The implementation of lock-in EBIC in systems equipped with a fast beam blanker is also described. In addition, this work shows and discusses the different mechanisms at play in EBIC imaging and their dependence on beam energy, sample impedance, and electrical measurement configuration, providing researchers with the basic information needed to apply the technique to their research.
Degradation due to electron beam exposure has posed a challenge in the use of electron microscopy to probe halide perovskite materials and devices. Herein, the interaction between the electron beam and the perovskite across acceleration voltages and at low probe currents is investigated in a scanning electron microscope (SEM) by monitoring the electron-beaminduced current (EBIC) response in perovskite solar cells in a planview configuration. SEM probe conditions are identified where dozens of repeated scans over a single region of the perovskite solar cell induce minimal electronic degradation. Overall, the induced current response of the perovskite device is found to strongly depend upon the beam condition: rapid decay occurs at high beam powers, the current activates at the lowest beam powers, and a newfound quasi-steady response is revealed at intermediate beam conditions. A quantitative window for the successful conduction of e-beam studies with minimal electronic degradation is revealed by evaluating induced current response over a wide range of perovskite devices, which invites broader use of SEM-based characterization techniques, including EBIC, as powerful techniques for correlative microscopy investigations.
In this project we aim to better understand the effect of geomagnetically induced currents (GIC) on power transformers. Expanding upon our previous work focused on producing a methodology for accuracy-enhanced computation of GIC signatures (i.e., time-domain current magnitude variation for the event duration) from a combination of physics-based and data-driven computational tools, we propose the use of these GIC signatures as inputs for a physically-detailed and optimized model of the power transformer to investigate how GIC determination and transformer modeling influence the evaluation of GIC effects on the transformer operation, as well as in its interaction with the power grid.
Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. Here, this paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.
Solar activities can cause geomagnetic disturbances (GMDs) that give rise to geomagnetically induced currents (GICs) which may compromise the reliability of the power system. In order to build more reliable models representing GMD interactions with the power grid, the power system’s detailed electrical model must be considered along with fluctuations in the earth’s magnetic and induced surface electric fields. Here, this study investigates the impact of incorporating spatially varying magnetic fields into surface electric field models on GMD risk metrics. A spatially independent magnetic field model and a spatially varying model are compared through simulations. To perform this analysis, the earth’s magnetic field disturbances are transformed into surface electric fields using respective one-dimensional earth conductivity models. Then, the modeling impact of these electric fields is studied using a 2,000-bus grid for Texas and a 25,000-bus grid for the northeast and mid- Atlantic regions of the United States. Simulation results reveal that the inclusion of spatially varying magnetic fields results in considerable differences in GMD risk metrics, highlighting the importance of accounting for spatial variability when assessing GMD risks in the power system.
Geomagnetically induced currents (GICs) can flow through transmission lines during geomagnetic disturbances, such as solar flares or coronal mass ejections. These currents can cause problems like transformer saturation and equipment damage. The most common method of mitigating GICs involves installing GIC neutral blocking devices (NBDs) in transformer neutrals. However, the wide application of capacitive GIC blocking devices may have unintended adverse effects on other devices, such as distance protection relays. As the number of inverter-based resources being connected to the transmission and sub-transmission systems increases, the likelihood of a sub-transmission line protected by a distance relay connected to a transformer with NBDs is increasing. Therefore, distance relays fed by IBRs and transmission lines with GIC-NBDs must be studied. This paper studies the effect of GIC-NBDs on a 69kV sub-transmission line of various lengths fed by a 25 MVA IBR and synchronous source. This work focused on the behavior of the GIC-NBDs using the measured apparent phase-to-ground and phase-to-phase impedance calculated by the relay and the source impedance ratio (SIR) during various electrical faults.
We report measurements of the current-induced spin torque produced by the delafossite antiferromagnet PdCrO 2 and acting on an adjacent ferromagnetic permalloy layer. The spin torque increases strongly as the temperature is reduced through the Néel temperature, when the PdCrO 2 transitions from a paramagnetic phase to a noncollinear antiferromagnetic state. This result is qualitatively consistent with density functional theory calculations regarding how spin-current generation changes upon antiferromagnetic ordering in PdCrO 2 .
It is observed experimentally that the sign of the Hall resistance can be flipped by a dc electric current in the twisted bilayer graphene (TBG) at 3/4 filling of the fourfold degenerate conduction flat bands. The experiment implies a switching of the valley polarization (VP) and topology in TBG. In this work, we present a theory on the current-induced switching of VP and topology. The presence of current in the bulk causes the redistribution of electron occupation in bands near the Fermi energy, which then deforms and shifts the band dispersion due to the Coulomb interaction. Above a critical current, the original occupied and empty bands can be swapped, resulting in the switching of VP and topology.
In tokamak experiments, the BT ramping down can drive off-axis and parallel inductive current. This approach leads to a decrease in q95 and an increase in normalized beta, βN. The off-axis inductive current also broadens the current profile. Typically, the 1.5D transport code is used to simulate the time evolution of the plasma current profile, which is based on the flux-surface-averaged Faraday’s law. The ONETWO code is one of those transport codes. However, this code cannot simulate the situation of the evolving toroidal field BT. This article proposes a new time-dependent model to take into account the BT ramping down situation. A modified formula of flux-surface-averaged Faraday’s law was derived to consider the effect of the BT ramping rate on the current evolution, and it was implemented in the ONETWO code. Then, the modified ONETWO code was used to simulate the BT ramping down experiment on DIII-D. The simulation result of the plasma current evolution with BT ramping down shows a broader current profile with smaller ohmic current induced by the poloidal field, compared to that without BT ramping down.
This is the final report for the DOE award DE-SC0019239, titled “Reconstruction of plasma equilibrium and eddy current induced error fields in the Lithium Tokamak eXperiment-b” for the period July 1, 2018 – July 2, 2023. This award supported research into computational models for plasma equilibrium and 3D conducting structures in the Lithium Tokamak eXperiment-b (LTX-b) using the PSI-Tri/TokaMaker and PSI-Tet codes. Additional detail on progress in support of these tasks is provided below.
Electrical grids increased the integration of power electronics sources onto transmission lines. In addition, recent reports show a significant rise in geomagnetic storms occurring in 2024. These geomagnetic storms can affect transmission lines by inducing electrical currents within them, potentially causing power outages due to overloaded power transformers. Geomagnetic induced current neutral blocking devices (GIC-NBDs) are capacitors on the ground of wye power transformers, to avoid damage caused by geomagnetic storms. The integration of distance relays and transmission lines with power electronics sources and GIC-NBDs needs to be studied to observe if GIC-NBDs and power electronics sources could adversely affect operation of the electrical grid. In this analysis, the effect of 2 MW power electronics sources and GIC-NBDs on distance relays is assessed for different 230 kV transmission line lengths in radial and nonradial power systems. The simulations measured the apparent impedances, with different electrical faults. Results for a typical 2,650 μF GIC-NBD application were presented on impedance plots, and the distance relay model operations were assessed. In conclusion, the tests for radial and nonradial power systems showed the behavior of the distance elements and source impedance ratios, assessing the effect of power electronics sources and GIC-NBDs on 230 kV transmission lines.