Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infant, Newborn”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Obstetrical Forceps Would Limit Force On An Infant's Head

Improved obstetrical forceps proposed to reduce injuries to newborn infants. Fabricated mostly of thermoplastic material. Reinforcing fibers added in hinge region of forceps. Combination of material, size, and shape chosen to make forceps yield elastically by amount keeping applied force from rising beyond maximum allowable value. Fiber-optic sensors for measuring strains embedded in forceps. Strain measurements used to compute tensile and compressive forces applied to infant's head.

Smeltzer, Stan↗

Radiation protection issues in galactic cosmic ray risk assessment

Radiation protection involves the limitation of exposure to below threshold doses for direct (or deterministic) effects and a knowledge of the risk of stochastic effects after low doses. The principal stochastic risk associated with low dose rate galactic cosmic rays is the increased risk of cancer. Estimates of this risk depend on two factors (a) estimates of cancer risk for low-LET radiation and (b) values of the appropriate radiation weighting factors, WR, for the high-LET radiations of galactic cosmic rays. Both factors are subject to considerable uncertainty. The low-LET cancer risk derived from the late effects of the atomic bombs is vulnerable to a number of uncertainties including especially that from projection in time, and from extrapolation from high to low dose rate. Nevertheless, recent low dose studies of workers and others tend to confirm these estimates. WR, relies on biological effects studied mainly in non-human systems. Additional laboratory studies could reduce the uncertainties in WR and thus produce a more confident estimate of the overall risk of galactic cosmic rays.

NASA Program Radiation Health↗

Temporal dynamics of emergency department and hospital admissions of pediatric asthmatics

Asthma is a chronic disease that can result in exacerbations leading to urgent care in emergency departments (EDs) and hospitals. We examined seasonal and temporal trends in pediatric asthma ED (1997-1999) and hospital (1986-1999) admission data so as to identify periods of increased risk of urgent care by age group, gender, and race. All pediatric ED and hospital admission data for Maryland residents occurring within the state of Maryland were evaluated. Distinct peaks in pediatric ED and hospital asthma admissions occurred each year during the winter-spring and autumn seasons. Although the number and timing of these peaks were consistent across age and racial groups, the magnitude of the peaks differed by age and race. The same number, timing, and relative magnitude of the major peaks in asthma admissions occurred statewide, implying that the variables affecting these seasonal patterns of acute asthma exacerbations occur statewide. Similar gross seasonal trends are observed worldwide. Although several environmental, infectious, and psychosocial factors have been linked with increases in asthma exacerbations among children, thus far they have not explained these seasonal patterns of admissions. The striking temporal patterns of pediatric asthma admissions within Maryland, as described here, provide valuable information in the search for causes.

Emergency Treatment/utilization↗

Validation of fluorescent-labeled microspheres for measurement of relative blood flow in severely injured lungs

The aim of the study was to validate a nonradioactive method for relative blood flow measurements in severely injured lungs that avoids labor-intensive tissue processing. The use of fluorescent-labeled microspheres was compared with the standard radiolabeled-microsphere method. In seven sheep, lung injury was established by using oleic acid. Five pairs of radio- and fluorescent-labeled microspheres were injected before and after established lung injury. Across all animals, 175 pieces were selected randomly. The radioactivity of each piece was determined by using a scintillation counter. The fluorescent dye was extracted from each piece with a solvent without digestion or filtering. The fluorescence was determined with an automated fluorescent spectrophotometer. Perfusion was calculated for each piece from both the radioactivity and fluorescence and volume normalized. Correlations between flow determined by the two methods were in the range from 0.987 +/- 0.007 (SD) to 0.991 +/- 0.002 (SD) after 9 days of soaking. Thus the fluorescent microsphere technique is a valuable tool for investigating regional perfusion in severely injured lungs and can replace radioactivity.

Non-NASA Center↗

New echocardiographic windows for quantitative determination of aortic regurgitation volume using color Doppler flow convergence and vena contracta

Color Doppler images of aortic regurgitation (AR) flow acceleration, flow convergence (FC), and the vena contracta (VC) have been reported to be useful for evaluating severity of AR. However, clinical application of these methods has been limited because of the difficulty in clearly imaging the FC and VC. This study aimed to explore new windows for imaging the FC and VC to evaluate AR volumes in patients and to validate this in animals with chronic AR. Forty patients with AR and 17 hemodynamic states in 4 sheep with strictly quantified AR volumes were evaluated. A Toshiba SSH 380A with a 3.75-MHz transducer was used to image the FC and VC. After routine echo Doppler imaging, patients were repositioned in the right lateral decubitus position, and the FC and VC were imaged from high right parasternal windows. In only 15 of the 40 patients was it possible to image clearly and measure accurately the FC and VC from conventional (left decubitus) apical or parasternal views. In contrast, 31 of 40 patients had clearly imaged FC regions and VCs using the new windows. In patients, AR volumes derived from the FC and VC methods combined with continuous velocity agreed well with each other (r = 0.97, mean difference = -7.9 ml +/- 9.9 ml/beat). In chronic animal model studies, AR volumes derived from both the VC and the FC agreed well with the electromagnetically derived AR volumes (r = 0.92, mean difference = -1.3 +/- 4.0 ml/beat). By imaging from high right parasternal windows in the right decubitus position, complementary use of the FC and VC methods can provide clinically valuable information about AR volumes.

NASA Discipline Cardiopulmonary↗

Height increase, neuromuscular function, and back pain during 6 degrees head-down tilt with traction

BACKGROUND: Spinal lengthening and back pain are commonly experienced by astronauts exposed to microgravity. METHODS: To develop a ground-based simulation for spinal adaptation to microgravity, we investigated height increase, neuromuscular function and back pain in 6 subjects all of whom underwent two forms of bed rest for 3 d. One form consisted of 6 degrees of head-down tilt (HDT) with balanced traction, while the other was horizontal bed rest (HBR). Subjects had a 2-week recovery period in between the studies. RESULTS: Total body and spinal length increased significantly more and the subjects had significantly more back pain during HDT with balanced traction compared to HBR. The distance between the lower endplate of L4 and upper endplate of S1, as measured by ultrasonography, increased significantly in both treatments to the same degree. Intramuscular pressures in the erector spinae muscles and ankle torque measurements during plantarflexion and dorsiflexion did not change significantly during either treatment. CONCLUSION: Compared to HBR, HDT with balanced traction may be a better method to simulate changes of total body and spinal lengths, as well as back pain seen in microgravity.

NASA Discipline Number 26-10↗

The Golden Canopies (Infant Radiant Warmer)

The cradle warmer is based on technology in heated transparent materials developed by Sierracin Corporation, Sylmar, California he original application was in heated faceplates for the pressure suit heated faceplates worn by pilots of an Air Force/NASA reconnaissance and weather research plane. Later, Sierracin advanced the technology for other applications, among them the cockpit windows of the NASA X-15 supersonic research vehicle and the helmet faceplates of Apollo astronauts. Adapting the technology to hospital needs, Sierracin teamed with Cavitron Corporation, Anaheim, California, which produces the cradle warmer and two other systems employing Sierracin's electrically-heated transparencies. Working to combat the infant mortality rate, hospitals are continually upgrading delivery room and nursery care techniques. Many have special procedures and equipment to protect infants during the "period of apprehension," the critical six to 12 hours after delivery. One such item of equipment is an aerospace spinoff called the Infant Radiant Warmer, a "golden canopy" which provides uniform, controlled warmth to the infant's cradle. Warmth is vitally important to all newborns, particularly premature babies; they lose heat more rapidly than adults because they have greater surface area in comparison with body mass.

Source record↗