Search NASA⌕ Search

SEARCH · Search NASA

Results for “Information Preservation and Dissemination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview

From the countless critical experiments performed in the world during the past century, high-quality integral benchmarks experiments have been collected and gathered into the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook), managed by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Working Group. This information preservation and dissemination effort is crucial for reactor licensing as well as criticality and radiation transport modeling validation. This summary reports on the status of a tentative benchmark addition to the ICSBEP Handbook. The proposed benchmark arises from legacy operation data of the Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR). The HPRR was a small, unmoderated, unshielded fast burst reactor that was used for research in health physics and radiobiology as well as teaching and training. As part of a comprehensive investigation of the available HPRR operation data and characteristics, different possibilities for use of the valuable results were studied. A critical experiment benchmark evaluation was performed, analyzing data coming from sub-critical and critical operation of the HPRR during operator training, steady-state irradiation of samples and before critical bursts. The results of the evaluation do not satisfy for the ICSBEP standards as the benchmark relative standard uncertainty is of about 4% for k eff , and the relative difference between sample calculations and expected k eff results is of about 1.5%. Due to those unsatisfactory results, it was decided not to pursue critical experiments evaluation of the HPRR presently and to focus instead on shielding type data for the creation of a criticality accident alarm system (CAAS) and shielding category benchmark, which is currently very scarce in the ICSBEP handbook—especially concerning critical, pulsed assembly, or reactor operation data. Several dosimetry and shielding experiments from HPRR burst operation were evaluated, with different benchmark metrics as sulfur fluence, Element 57 dose, or neutron fluence at different distances and under different shield materials conditions. An evaluation focusing on the Element 57 neutron dose as a benchmark metric was submitted to the ICSBEP Technical Review Group (TRG) meeting in October 2021, and the inclusion of the evaluation in the ICSBEP Handbook was deferred. The main change proposed by the international experiment evaluation experts is to use the neutron fluence measured by Bonner spheres as a benchmark metric. This represents a quantity closer to that actually measured by the experimentalists of the HPRR compared to the Element 57 dose, which adds another step of data transformation, thus potentially adding uncertainty to the benchmark. The evaluation has been updated and will be submitted to the 2022 ICSBEP TRG meeting for inclusion in the 2023 edition of the ICSBEP Handbook. The evaluation is performed using the KENO and MAVRIC combination from the SCALE 6.2.4 code suite which was previously used in similar CAAS benchmarks to allow for the use of variance reduction techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of Polyethylene and Blank Pulsed Sphere Experiments Using Deuteron Transport Feature in COG

From the late 1960s to about 1985, LLNL undertook a series of ‘pulsed sphere’ experiments for 31 materials involving 148 different experiments using 75 different spheres. The purpose was to measure the neutron leakage spectra for different materials from 14-MeV neutrons generated by 3 H(d,n) 4 He reactions induced by an incident D+ beam from the Insulated Core Transfer (ICT) accelerator at LLNL. This deuteron beam was focused to impinge upon tritium loaded onto a titanium substrate within a low mass target assembly placed within the center of a spherical shell constructed from the material of interest. COG is a three-dimensional, continuous energy, Monte Carlo code, developed by Lawrence Livermore National Laboratory (LLNL). Recent additions to COG include alpha and deuteron particle transport in order to directly calculate (α,n) and 3 H(d,n) 4 He reactions, and resulting neutron emission spectra. Results of the direct deuteron transport calculation for the 0.8 MFP (mean free path) polyethylene sphere with PILOT B detector was previously published. The purpose of this paper is to present expanded COG results showing the neutron peak from deuterium buildup ( 2 H(d,n) 3 He) due to tritium decay in the target. Cross section data libraries used are ENDF/B-VIII.0 for neutrons and ENDF/B-VII.1 for deuterons, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using the Criticality Accident Alarm System modeling capabilities in SCALE [Slides]

The following is a summary of advice for CAAS modeling in SCALE. Refer to the SCALE Criticality Safety and Radiation Shielding training slides or to the SCALE manual for exact syntax. Use a mesh for the fission source that is the most adequate for the problem to solve (coarse/fine). Don’t spend unnecessary resources; simplify the model if it does not impact the final results of interest. Be careful to deactivate secondary fissions in MAVRIC or the calculation may never end. Check that k eff and $\overline{\upsilon}$ calculated results are logical. Between KENO and MAVRIC, cross section libraries, materials, geometry, and mesh grid can be the same or different. Iterative calculations are usually complex problems that need variance reduction. It will be hard to find the best solving parameters in the first attempt; expert judgement is needed. Check each step separately. Use Fulcrum to visualize fission source, mesh source, and spatial/energy distributions to find potential errors or impactful imprecisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FY21 Progress of the Oak Ridge Health Physics Research Reactor CAAS Benchmark Evaluation [Slides]

The FY21 version of the evaluation, focusing on element 57 dose at 3 meters, was presented at the ICSBEP Technical Review Group meeting in October 2021 and was not accepted for 2022 publication in the handbook. The main issue was identified and replacement of the element 57 neutron dose benchmark metric by neutron fluence (closer to what was measured) is required. A subgroup was formed, confident for the updated neutron fluence evaluation to be accepted in the ICSBEP handbook. The updated evaluation will be presented again at the 2022 ICSBEP TRG for publication in the 2023 handbook.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CritView Database Expansion [Slides]

This presentation is intended to provide the audience with the current status of CritView and the recent database expansion.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SCALE Calculations Replicating ARH-600 Data

This report documents Standardized Computer Analyses for Licensing Evaluation (SCALE) calculations replicating data from the ARH-600 criticality handbook. These calculations complement those reproduced with MCNP in PRC-NS-00009. Calculations were performed with SCALE version 6.1, using the v7-238 cross section library. The original ARH-600 data were calculated by the Atlantic Richfield Hanford (ARH) Company starting in the 1960s, and Monte Carlo N-Particle (MCNP) calculations were performed by the Hanford Plateau Remediation Company in 2010. This report is not intended to replace final analysis of fissile systems by qualified criticality personnel.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delayed Critical Enriched Uranium Metal, 7-in.-diam. Cylinder with Thin Stainless Steel Top and Bottom Reflectors

Three 7 in. diameter highly enriched uranium (HEU; 93.17 wt % 235 U) metal cylinders were assembled on the vertical assembly machine of the Oak Ridge Critical Experiments Facility (ORCEF) with thin stainless steel reflectors (0.5, 1, and 2 in. thick) on the top and bottom. These experiments were performed during January 13–25, 1965, and used seven operational days at ORCEF. Before these experiments, unreflected and unmoderated 7 in. diameter HEU metal cylinders had been assembled to delayed criticality at ORCEF, and the results were benchmarked in HEU-MET-FAST-051. In addition to the critical experiments, the prompt neutron decay constant was measured via the Rossi-α technique, and those results are also presented in this report. To achieve near-delayed-critical systems, 5 × 5 × 0.03125 in. rectangular uranium metal parts were used on top of 7 in. diameter cylinders inside the top reflector. The delayed critical configuration from the three experiments described herein are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Benchmark Evaluation Program (ICSBEP), coordinated by the Nuclear Energy Agency, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainty in $k_{eff}$ is expected to be as low as ±0.0002. The prompt neutron time decay data could be the basis of an International Reactor Physics Evaluation Program benchmark.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Critical Benchmark Creation [Slides]

During the evaluation of Oak Ridge National Laboratory Health Physics Research Reactor operation data for critical benchmark creation, a detailed, functional SCALE model was built, and experimental data was evaluated for the creation of a critical benchmark. The estimated experimental uncertainty is about 3800 pcm, which is considered very high. The relative difference between expected and calculated keff values is about 1.5 %, also considered very high. It was concluded that a good quality critical benchmark worthy of the ICSBEP standards cannot be created from HPRR data in the present conditions. Locating the HPRR fuel to obtain an uncertainty on the density would aid in solving this issue.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pulsed Sphere Time of Flight Neutron Spectrum Measurements: Blank Run and 1.8 Mean-Free-Path thick Polyethylene Moderating Sphere

From the late 1960s to 1985, Lawrence Livermore National Laboratory (LLNL) undertook a series of ‘pulsed sphere’ experiments for 32 materials involving 148 different experiments using 75 different spheres to measure the neutron leakage spectra for different materials from 14-MeV neutrons generated by 3 H(d, n) 4 He reactions induced by an incident D+ beam from the Insulated Core Transformer (ICT) accelerator at LLNL. This deuteron beam was focused to impinge on tritium loaded onto a titanium substrate within a low mass target assembly placed within the center of a spherical shell constructed from the material of interest. The neutron time of flight was measured at a detector outside a collimator. The program was intended to be comprehensive with numerous targets of various thicknesses spanning the periodic table from H to 239 Pu. Five different neutron detectors were utilized to avoid possible systematic errors due to differences in detector responses. Further, these measurements were designed with the aim that the simple geometry of the measurements could be easily simulated to validate Monte Carlo transport codes and nuclear data libraries. As a result, these benchmarks have been extensively used in the validation of ENDL, ENDF and other libraries. Two experiments selected as benchmark cases in this evaluation are: 1) target assembly without material sphere (blank run), and 2) target assembly with a hollow polyethylene sphere, 1.8 mean free path (mfp) or 16.56 cm thick.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delayed Critical and Subcritical Experiments with Polyethylene Moderated Unreflected Thin 15 in. Diameter HEU Metal Plates

The thin ~15 in. diameter highly enriched uranium (HEU) metal plates were assembled to delayed criticality at the Oak Ridge Critical Experiments Facility (ORCEF) in 1969 with various thicknesses of polyethylene (varying from 1/16 to 2$\frac{3}{8}$ inches) between uranium metal plates. The average 235 U enrichment was 93.27 wt. %. These unreflected critical configurations contained 4$\frac{2}{3}$ to 20$\frac{5}{6}$ thin 15 in. diameter HEU metal plates (on loan from Los Alamos National Laboratory [LANL] and shipped to Oak Ridge National Laboratory [ORNL] on June 3, 1969). Depending on the thickness of polyethylene, the enriched uranium masses varying from 28,053 to 135,148 grams. Fractional plate sections consisted of the appropriate number of 60° pie sections. In addition to the measurement at delayed criticality, subcritical measurements were also performed by the inverse kinetic rod drop method. Prompt neutron decay constant measurements were also performed by the Rossi alpha and randomly pulsed neutron method using a time-tagged spontaneous fission californium neutron source; these are briefly reported here. At the time of these measurements in 1969, the thin HEU metal plates were in near-pristine condition with extremely little oxidation, allowing better descriptions of the uranium plates than the use of these plates in a heavily oxidized and deteriorated condition in recent reflected benchmark experiments at the LANL facility at the Nevada Test Site with these same thin highly enriched uranium metal plates. This report documents the experimental information for the measurements performed so that later researchers can perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Evaluation Program (ICSBEP) or a Nuclear Energy Agency (NEA) benchmark. Data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program once the uncertainty analysis on the measured neutron multiplication factors is completed. Additional data—such as the dimensional inspection reports, uranium isotopic information, and other relevant particulars—should be retrieved from the Y-12 Plant or LANL and incorporated in the final ICSBEP benchmark. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in $k_{eff}$ could be as low as ± 0.0002 for some configurations. Other experiments with smaller-diameter than 15 in. diameter HEU metal plates have been benchmarked in HEU-METFAST-001. The prompt neutron time decay measurements could be the basis for an International Reactor Physics Benchmark Program. Preparation of the present report is part of an effort at ORNL to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other US Department of Energy critical experiments facilities using more than 500 operational days of critical facility time. This work for this report publication was supported by the Nuclear Criticality, Radiation Transport and Safety NCSP Program at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LLNL IPD Tasks: ICSBEP and Pulsed Spheres Benchmark [Slides]

This lecture presented benchmark of the blank and polyethylene spheres at SINBAD in April 2023. In responding to comments about the building, we uncovered a large amount of additional detailed information about the building and experimental set up. We incorporated this new information into an even higher fidelity model and are working on uncertainty analysis at a low level. Scheduled to present at SINBAD meeting in April 2024.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

The SINBAD evaluation of legacy HPRR experiments [Slides]

The HPRR experiments were evaluated – legacy experiment: a lot of unknowns and high uncertainty. The SINBAD evaluation of legacy HPRR experiments version 1 is soon to be released. It will include neutron fluence and kerma with no shield, steel shield, and Lucite shield. Sample calculation results are mostly good, with notable artifacts due to Bonner sphere unfolding imprecisions that seem complex to be solved. Version 2 will include sulfur pellet activation results with the same shield configurations, and maybe gamma dose and fast results if there is interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Engagement opportunities in OECD NEA benchmark development

A myriad of opportunities is available to collaborate via international benchmark exercises and experimental data preservation activities. Many such opportunities abound under the auspices of the Nuclear Science Committee of the Organisation for Economic Co-operation and Development Nuclear Energy Agency (NEA). Key projects and activities of relevance to the development of advanced reactors design include the International Criticality Safety Benchmark Evaluation Project (ICSBEP), the International Reactor Physics Experiment Evaluation Project (IRPhEP), the International Assay Data of Spent Nuclear Fuel Database (SFCOMPO), the Shielding Integral Benchmark and Archive Database (SINBAD), and The International Experimental Thermal HYdraulicS Database (TIETHYS), and various cooperative benchmark exercises. Interested participants are encouraged to contact the leadership and secretariat of the various Technical Working Groups and Working Parties to become more engaged. This paper provides a summary of the current benchmark exercises and experimental databases available for international participation.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Intrinsic value of the international benchmark projects, ICSBEP and IRPhEP, for advanced reactor development

The International Criticality Safety Benchmark Evaluation Project, a sanctioned program under the auspices of the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development, has been a highly successful and productive collaboration, now encompassing over 5,000 evaluated experimental benchmarks trusted and relied upon throughout the international nuclear communities. The success of this project led to the development of the International Reactor Physics Experiment Evaluation Project, which is dedicated to the evaluation of benchmark experiment data to sustain current and future reactor physics validation needs. These exemplary programs, and their widely utilized handbooks, serve as gold standards to which other databases strive to emulate. The purpose of the two projects is to preserve modern and legacy experimental data and evaluate it in a standardized handbook format to provide quality benchmarks to support modern and future criticality safety and reactor physics validation. These two projects have often served as the mechanism through which historic and modern neutronics experiments are evaluated and shared across international borders, to best provide unique, high-quality peer-reviewed, and often otherwise unavailable, benchmark data. The contents of these handbooks are utilized not only in validating criticality safety, reactor physics, and advanced reactor calculations, but are used to validate neutronics calculations and nuclear data for most other nuclear applications. This paper discusses both international programs and available content to enable advanced reactor design validation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Criticality Accident Alarm System Benchmark Creation

Over the last few decades, the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Working Group has focused on gathering critical and subcritical benchmark experiment data from different facilities around the world for inclusion in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook). The compiled data can be used by criticality safety analysts to help validate their calculation tools and cross-section libraries for a variety of applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗