Search NASA⌕ Search

SEARCH · Search NASA

Results for “Initial Transmission Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Status of ORNL TSL evaluations [Slides]

This lecture provides details on the status of ORNL TSL evaluations. Main sections include modeling of concrete, updates of polyethylene evaluation, and initial transmission measurements at Oak Ridge National Labatory (ORNL). The presentation Conclusions show that literature review and initial modeling of concrete components have been performed. INS and transmission measurements of concrete and hydrated cement have been also planned. Additionally, A new TSL library for Polyethylene was created and submitted to NNDC and development for a new transmission capability at ORNL is underway.

36 MATERIALS SCIENCE↗

Combining Spectroscopic Techniques to Determine the Optical Constants of Powdered Lactose

A method for deriving the optical constants (n/k) of organic powdered materials using pressed pellets in the mid-infrared spectral range is introduced that combines variable angle spectroscopic ellipsometry and transmission spectroscopy. The approach is applied to lactose, in which three different forms of pellets were pressed and measured: A pure lactose pellet and a mixed lactose/KBr pellet with a large analyte percentage were used for ellipsometric measurements, and a KBr transmission pellet with only a small analyte percentage were used for transmission measurements. The transmission data provide an initial set of oscillators and improve the spectral fitting of weak absorption features (k<0.01). Ellipsometric data for the pure and mixed pellets are then fit simultaneously to derive the final n/k values for lactose from 6000-400 cm-1. An alternative method just using the ellipsometric data from the mixed pellet and the transmission data is also presented and shows good agreement with the multi-sample analysis, providing a simpler method for powders that do not press easily into pure pellets. Finally, the derived optical constants are used to model the reflectance data, demonstrating a good match with the measured reflectance spectra if non-idealities are included.

Yokosuk, Michael O.↗

Measurement of the properties of lossy materials inside a finite conducting cylinder

Broadband, swept frequency measurement techniques were investigated for the evaluation of the electrical performance of thin, high temperature material coatings. Reflections and transmission measurements using an HP8510B Network Analyzer were developed for an existing high temperature test rig at NASA Lewis Research Center. Reflection measurements will be the initial approach used due to fixture simplicity even though surface wave transmission measurements would be more sensitive. The minimum goal is to monitor the electrical change of the material's performance as a function of temperature. If possible, the materials constitutive parameters, epsilon and muon will be found.

Dominek, A.↗

Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment

Abstract In a high‐pressure injection fault activation experiment conducted at the Mont Terri underground research laboratory in Switzerland, the transmissivity of the Opalinus Clay fault significantly increased due to opening and shearing. The fluid injection, spanning a few hours, generated a 10 m radius fault activation patch. Subsequent pressure pulse tests conducted bi‐weekly for a year revealed the gradual return of fault transmissivity to its initial state. The study utilized fluid pressure decay analysis, optical fiber monitoring, continuous active source seismic measurements and borehole displacement sensors for measuring fault displacements. The fault zone exhibited a dilation of approximately 1.4 mm, associated with both normal and tangential movements during activation, resulting in a sudden transmissivity increase from 1 × 10 −12 to 3.2 × 10 −7 m 2 /s. Early post‐activation, transient compaction and the subsequent slow compaction were observed, transitioning to an extension regime. The pressure pulse tests demonstrated a rapid transmissivity drop by more than two orders of magnitude within the first 10 days, followed by a gradual and less pronounced decrease. Plastic shear and compaction dominated the transmissivity evolution until 70 days after injection ended, followed by a period where additional factors, such as clay mineral swelling, influenced the behavior. Extrapolation suggested a sealing process taking at least 50 years after the initial activation. Plain Language Summary A field‐scale fault activation experiment offers valuable insights into the elasto‐plastic processes governing the sealing of shale faults. The experiment reveals a rapid increase in the fault's transmissivity by approximately five orders of magnitude during activation. Subsequent observations show a gradual transmissivity decrease by about three orders of magnitude post‐activation, with slow long‐term plastic shear and compaction of the fault competing against secondary processes, notably clay mineral swelling. All conceptual models employed to interpret these field data converge on the estimation that the fault's return to its initial low transmissivity state would require a minimum of 50 years. Key Points High‐pressure injection fault activation experiment at the Mont Terri underground research laboratory Continuous transmissivity measurements record self‐sealing inside a clay‐rich fault zone Transmissivity undergoes a phase of domination by slow plastic compaction and shearing during the initial post‐activation period, with mineral swelling exerting its influence over the long term

Guglielmi, Yves↗

Measurement of nuclear interaction cross sections towards neutron-skin thickness determination

The accuracy of reaction theories used to extract properties of exotic nuclei from scattering experiments is often unknown or not quantified, but of utmost importance when, e.g., constraining the equation of state of asymmetric nuclear matter from observables as the neutron-skin thickness. In order to test the Glauber multiple-scattering model, the total interaction cross section of 12 C on carbon targets was measured at initial beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The measurements were performed during the first experiment of the newly constructed R 3 B (Reaction with Relativistic Radioactive Beams) experiment after the start of FAIR Phase-0 at the GSI/FAIR facility with beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The combination of the large-acceptance dipole magnet GLAD and a newly designed and highly efficient Time-of-Flight detector enabled a precise transmission measurement with several target thicknesses for each initial beam energy with an experimental uncertainty of ±0.4%. A comparison with the Glauber model revealed a discrepancy of around 3.1% at higher beam energies, which will serve as a crucial baseline for the model-dependent uncertainty in future fragmentation experiments.

Astronomy & Astrophysics↗

Shear-induced surface alignment of polymer dispersed liquid crystal microdroplets on the boundary layer

Polymer dispersed liquid crystal thin films have been deposited on a glass substrate, utilizing the processes of polymerization and solvent evaporation induced phase separation. Liquid crystal microdroplets trapped on the upper surface of the thin film respond to the shear stress due to air or gas flow on the surface layer. Response to an applied step shear stress input on the surface layer has been measured by measuring the time response of the transmitted light intensity. Initial results on the measurements of the light transmission as a function of the air flow differential pressure indicate that these systems offer features suitable for boundary layer and gas flow sensors.

Parmar, D. S.↗

Improvement of Quantification in Non-Destructive Characterization of Radioactive Waste Packages -Introduction to the Ideas of a Currently Started Project - 20197

For the characterization of radioactive waste packages (e.g. 200-L drums) with inhomogeneous activity and density distributions preferably non-destructive methods like segmented gamma scanning and transmission measurements are applied. While the first is used for identification of the radioactive inventory, both are necessary for a reliable activity quantification. Although at nuclear facilities, segmented gamma scanner are state-of-the-art and are mostly equipped with a vertically moveable transmission source the combining of this data and further a-priori information improving accuracy in data estimation giving realistic, reliable and traceable uncertainty estimations are improvable. This challenge is tackled by a R and D project funded by the German Federal Ministry of Education and Research (BMBF). The boundary conditions for this project are (i) taking into account the typical instrumentation available at nuclear facilities, (ii) minimize the overall measurement time and (iii) combining data from emission and transmission measurements by Bayesian methods. For the R and D project, being still in its initial stage, the basic ideas, the data used for evaluation and the result of a preliminary investigation demonstrating the proof of principle are presented. Additionally, some first aspects on spatial resolution in emission and transmission measurements are addressed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of transmission loss characteristics using acoustic intensity techniques at the KU-FRL Acoustic Test Facility

The transmission loss characteristics of panels using the acoustic intensity technique is presented. The theoretical formulation, installation of hardware, modifications to the test facility, and development of computer programs and test procedures are described. A listing of all the programs is also provided. The initial test results indicate that the acoustic intensity technique is easily adapted to measure transmission loss characteristics of panels. Use of this method will give average transmission loss values. The fixtures developed to position the microphones along the grid points are very useful in plotting the intensity maps of vibrating panels.

Roskam, J.↗

Research in millimeter wave techniques

The following is investigated; (1) the design of a 183 GHz single ended fundamental mixer to serve as a back up mixer to the subharmonic mixer for airborne applications, (2) attainment of 6 db single sideband conversion loss with the 6 GHz subharmonic mixer model, together with initial tests to determine the feasibility of pumping the mixer at w sub s/4, (3) additional ground based radiometric measurements, and (4) derivation of equations for power transmission of wire grid interferometers, and initial tests to verify these equations.

Mcmillan, R. W.↗

The study of dopant segregation behavior during the growth of GaAs in microgravity

An investigation into the segregation behavior of selenium doped gallium arsenide during directional solidification in the microgravity environment was conducted using the Crystal Growth Furnace (CGF) aboard the first United States Microgravity Laboratory (USML-1). The two crystals grown were 1.5 cm in diameter and 16.5 cm in length with an initial melt length of 14 cm. Two translation periods were executed, the first at 2.5 microns/s and after a specified time, which was different between the two experiments, the translation rate was doubled to 5.0 microns/s. The translation was then stopped and the remaining sample melt was solidified using a gradient freeze technique in the first sample and a rapid solidification in the second experiment. Measurement of the selenium dopant distribution, using quantitative infrared transmission imaging, indicates that the first sample initially achieved diffusion controlled growth as desired. However, after about 1 cm of growth, the segregation behavior was driven from a diffusion controlled growth regime to a complete mixing regime. Measurements in the second flight sample indicated that the growth was always in a complete mixing regime. In both experiments, voids in the center line of the crystal, indicative of bubble entrapment, were found to correlate with the position in the crystal when the translation rates were doubled.

Matthiesen, David H.↗

High temperature nuclear data measurements of SiC, ZrC, and MgO [Slides]

Performed temperature dependent measurements of SiC and ZrC at ARCS instrument at SNS. Performed temperature dependent measurements of SiC, ZrC, and MgO at VISION instrument at SNS. Performed initial atomistic modeling of these materials using various techniques, including machine learned potentials. Future work includes temperature dependent transmission measurements of these materials, as well as improving the machine learned potentials with more training data and different machine learned frameworks.

ARCS↗

Overview of oxygen opacity experiments at the National Ignition Facility and investigation of potential systematic errors

Experiments to measure oxygen opacity at stellar interior conditions have been performed at the National Ignition Facility in a Discovery Science campaign. These experiments utilize the Opacity-on-NIF platform with a sample comprised of O, Mg, and Si. The spectral data from the Opacity Spectrometer cover the 1000–2000 eV photon energy range showing bound-free continuum absorption from O and line absorption from Mg and Si. DANTE and the Gated X-ray Detector are employed to measure the sample plasma’s temperature and density, respectively. Initial data show lower transmission than expected by theoretical models, raising questions of whether potential background or data uniformity concerns could produce systematic errors in the inferred transmission. Here, we investigate three concerns thought to be important for the oxygen opacity data, including instrumental scattered background, sample self-emission non-uniformity, and backlight continuum non-uniformity. Additionally, we show the effect of a recently developed method to account for 2nd order crystal reflection. The total effect of these concerns on one experiment is found to be small compared to the observed difference between the inferred transmission and a model calculation at the inferred temperature and density. Thus, we conclude that these potential sources of systematic error cannot account for the observed difference, increasing the likelihood of a real effect due to the high temperature and density conditions. However, because this is only a single experiment, we cannot make a firm conclusion. More experiments measuring the opacity and necessary calibrations are needed to assess the reproducibility and uncertainty of this result.

79 ASTRONOMY AND ASTROPHYSICS↗

Microshutter Arrays for the NGST NIRSpec

We are developing a programmable multiobject field selector for the NGST NIRSpec. This device is a microshutter array, a close-packed 2000 x 2000 array of 100 micrometer x 100 micrometer shutters fabricated with Micro-ElectroMechanical Systems (MEMS) technologies. The shutters are opened using a magnet scanned over the array. The shutters are held open by electrostatic potentials on adjacent vertical electrodes. Modeling of the magnetic actuation of the microshutters allowed optimization of the magnetic field configuration, the distance between magnet and shutters, and the force and torque produced by the magnet. The results of laboratory tests are consistent with our modeling. We have demonstrated actuation, latching and addressing. We are able to rotate shutters out of the plane up to 90 degree and more, to latch them electrostatically to the walls and release them selectively. During the last six month all critical elements of the array have been demonstrated. Fabrication processes were developed to deposit vertical electrodes on support grid side walls and insulated light-shields that block the gaps between shutters and the support grid. Physical optics analysis was performed to assess the expected optical performance of the microshutters. A preliminary Fourier optics analysis on the microshutter array performance has been carried out. More detailed analysis of wave propagation through 3D structures is a next step. An optical test station for verifying optical parameters of the shutter array at room temperature has been developed. It allows to measure parameters, such as transmission, scattering, contrast ratio, and diffraction of the array structure. Initial data have been acquired and are being analyzed and compared to theoretical predictions.

Moseley, Harvey↗

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary of the Initial Post-Irradiation Characterization of HFIR-Irradiated Low-N and High-N HT-9 Steel

Reference cladding systems for sodium fast reactors are based on the historical steel, HT-9. HT-9 is a Fe12Cr ferritic/martensitic steel with additions of Mo, W, V, and other minor elements and demonstrates low irradiation swelling and adequate mechanical properties. Extensive irradiation literature exists on the use of HT-9 as cladding for metal fuel, primarily irradiation on the U-Zr/HT-9 system from the Experimental Breeder Reactor-II (EBR-II) and Fast Flux Test Facility (FFTF) sodium fast reactor, and as a structural material from experiments in the FFTF. The large amount of historical data makes the U-Zr/HT-9 system the reference fuel specification for many nuclear reactor vendors that seek to license modern sodium-cooled fast reactors in the United States. However, it is yet unclear how variations in impurity content within HT-9 fundamentally affect irradiation performance at various irradiation temperatures. Recent work suggests that impurity content may noticeably alter the production of helium through nuclear transmutation. For these reasons, High-Flux Isotope Reactor (HFIR) irradiation of HT-9 steels with known variations in the impurity content is particularly timely to generate data to enable more accurate refinement of the chemical specification for nuclear-grade HT-9 material. This report summarizes the initial transmission electron microscopy characterization of HFIR-irradiated HT-9 steels following mechanical property measurements by the Advanced Fuels Campaign (AFC). This report includes qualitative results of the cavity, dislocation loop and cluster/precipitate microstructures as well as radiation-induced segregation. Quantitative results are being shared with partner institutions and will be included in more detail in a future report in FY2026.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calibration improvements expand filterscope diagnostic use

The filterscope diagnostic on DIII-D utilizes photomultiplier tubes to measure visible light emission from the plasma. The system has undergone a substantial upgrade since previous attempts to cross-calibrate the filterscope with other spectroscopic diagnostics were unsuccessful. The optics now utilize a dichroic mirror to initially split the light at nearly 99% transmission or reflectance for light below or above 550 nm. This allows the system to measure D α emission without degrading visible light emission from the plasma for wavelengths below 550 nm (to measure D β , D γ , W–I, C-III, etc.). Additional optimization of the optical components and calibration techniques reduce the error in the signal up to 10% in some channels compared to previous methods. Cross-calibration measurements with two other high resolution spectroscopic diagnostics now show excellent agreement for the first time. This expands the capabilities of the filterscope system allowing measurement of divertor detachment, emission profiles, edge-localized mode behavior, and plasma–wall interactions. Additionally, it enables direct comparisons against calculations from boundary plasma simulations. These were not possible before.

47 OTHER INSTRUMENTATION↗

Summary of in situ epitaxial nucleation and growth measurements

In situ nucleation and growth measurements of Ag and Au on single-crystal PbSe thin films were made using a transmission electron microscope. Properties studied were polymorphism, crystalline perfection, and the stoichiometric composition of the initial and the autoepitaxially thickened PbSe substrates. The quantitative nucleation and cluster growth measurements were limited to low-saturation conditions. The epitaxial orientations are discussed, and evidence is presented as to the stage of deposition at which the epitaxial order for Ag is introduced. Strong substrate/overgrowth interaction manifested itself by alloying and interdiffusion.

Poppa, H.↗

dc electric field meter with fiber-optic readout

The design of a dc electric field meter capable of measuring the magnitude and direction of the electric field at an arbitrary location above the ground plane is described. The meter is based on measuring induced charge on a split cylindrical electrode pair which is rotated around its axis of symmetry. Data readout is by fiber-optic cable using pulse frequency encoding. The sensing head is electrically isolated. Initial results are reported from a series of tests at General Electric's High Voltage Transmission Research Facility, Pittsfield, MA. The electric field was measured in a large test cage and under a dc test line. Measurement of field magnitude and direction around a human subject standing under the conductor was demonstrated.

Johnston, Alan R.↗