Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Detector Instrumentation, Energy Reconstruction and Data Analysis in the DUNE and NOvA Neutrino Experiments

Neutrino oscillations are so far the only experimental observation beyond the standard model since its development four decades ago. The remaining fundamental questions that can be answered by long-baseline neutrino oscillations are (1) the CP violation (whether neutrinos and antineutrinos behave the same way in oscillation), and (2) the mass hierarchy ($m_3>m_{1,2}$ or $m_{1,2}>m_3$), and (3) the octant of $\theta_{23}$ ($\theta_{23}>45^\circ, =45^\circ$ or $<45^\circ$). The PI's group at UCI focuses on long-baseline neutrino experiments DUNE and NOvA, key components of DOE's Intensity Frontier program. NOvA is the current major U.S.-based long-baseline neutrino experiment aiming to solve the mass hierarchy and $\theta_{23}$ octant. It is taking $\nu$ and $\bar{\nu}$ data from the NuMI beam at Fermilab. DUNE is the next-generation flagship neutrino experiment in the U.S. which is designed to decisively determine neutrino CP violation, mass hierarchy and $\theta_{23}$ octant. DUNE is Fermilab's first priority, and has been established as an international collaboration. During the period covered by the report, the PI's group has been exceptionally productive, with leading contributions to DUNE argon-purity monitoring detectors, NOvA/DUNE deep-learning reconstruction, and NOvA oscillation and near detector (ND) analyses. The group also is actively involved in DUNE/NOvA detector operation, data production, calibration, software upgrade and maintenance, and ProtoDUNE cold electronic QA/QC. Specifically, we have made accomplishments in the following four research projects: 1) Purity monitor R\&D and data analysis for DUNE, 2) Deep-learning-based energy reconstruction at NOvA and DUNE, 3) Oscillation analysis at NOvA, and 4) $\nu$-e elastic scattering analysis at NOvA.

47 OTHER INSTRUMENTATION↗

Detectors and Instrumentation [Slides]

D&I targets diagnostic maturation and development for subcritical and hydrodynamic experiments 2 to 5 years into the future. Key technology areas include imaging, detectors, instruments and control systems. Most of the work scope is funded from Stockpile Stewardship’s Hydrodynamic and Subcritical Experiment Execution Support (HSEES) portfolio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Lightning and Radio Emission Detector (LRD) instrument

The Lightning and Radio Emission Detector (LRD) instrument will be carried by the Galileo Probe into Jupiter's atmosphere. The LRD will verify the existence of lightning in the atmosphere and will determine the details of many of its basic characteristics. The instrument, operated in its magnetospheric mode at distances of about 5, 4, 3, and 2 planetary radii from Jupiter's center, will also measure the RF noise spectrum in Jupiter's magnetosphere. The LRD instrument is composed of a ferrite-core radio frequency antenna and two photodiodes mounted behind individual fisheye lenses. The output of the RF antenna is analyzed both separately and in coincidence with the optical signals from the photodiodes. The RF antenna provides data both in the frequency domain (with three narrow-band channels, primarily for deducing the physical properties of distant lightning) and in the time domain with a priority scheme (primarily for determining from individual RF waveforms the physical properties of closeby-lightning).

Lanzerotti, L. J.↗

Report of the Instrumentation Frontier Working Group for Snowmass 2021

Detector instrumentation is at the heart of scientific discoveries. Cutting edge technologies enable US particle physics to play a leading role worldwide. This report summarizes the current status of instrumentation for High Energy Physics (HEP), the challenges and needs of future experiments and indicates high priority research areas. The Snowmass Instrumentation Frontier studies detector technologies and Research and Development (R&D) needed for future experiments in collider physics, neutrino physics, rare and precision physics and at the cosmic frontier. It is divided into more or less diagonal areas with some overlap among a few of them. We lay out five high-level key messages that are geared towards ensuring the health and competitiveness of the US detector instrumentation community, and thus the entire particle physics landscape.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report of the Instrumentation Frontier Working Group for Snowmass 2021

Detector instrumentation is at the heart of scientific discoveries. Cutting edge technologies enable US particle physics to play a leading role worldwide. This report summarizes the current status of instrumentation for High Energy Physics (HEP), the challenges and needs of future experiments and indicates high priority research areas. The Snowmass Instrumentation Frontier studies detector technologies and Research and Development (R&D) needed for future experiments in collider physics, neutrino physics, rare and precision physics and at the cosmic frontier. It is divided into more or less diagonal areas with some overlap among a few of them. We lay out five high-level key messages that are geared towards ensuring the health and competitiveness of the US detector instrumentation community, and thus the entire particle physics landscape.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser beam methane detector

Instrument uses infrared absorption to determine methane concentration in liquid natural gas vapor. Two sensors measure intensity of 3.39 mm laser beam after it passes through gas; absorption is proportional to concentration of methane. Instrument is used in modeling spread of LNG clouds and as leak detector on LNG carriers and installations. Unit includes wheels for mobility and is both vertically and horizontally operable.

Hinkley, E. D., Jr.↗

Chandra X-Ray Observatory's Radiation Environment and the AP-8/AE-8 Model

The Chandra X-ray Observatory (CXO) was launched on July 23, 1999 and reached its final orbit on August 7, 1999. The CXO is in a highly elliptical orbit, approximately 140,000 km x 10,000 km, and has a period of roughly 63.5 hours (approx. 2.6 days). It transits the Earth's Van Allen belts once per orbit during which no science observations can be performed due to the high radiation environment. The Chandra X-ray Observatory Center (CXC) currently uses the National Space Science Data Center's "near Earth" AP-8/AE-8 radiation belt model to predict the start and end times of passage through the radiation belts. However, our scheduling software only uses a simple dipole model of the Earth's magnetic field. The resulting B, L magnet coordinates, do not always give sufficiently accurate predictions of the start and end times of transit of the Van Allen belts. We show this by comparing to the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument. We present evidence that demonstrates this mis- of the radiation belts as well as data that also demonstrate the significant variability of one radiation belt transit to the next as experienced by the CXO. We present an explanation for why the dipole implementation of the AP-8/AE-8 gives inaccurate results. We are also investigating use of the Magnetospheric Specification and Forecast Model (MSM) - a model that also accounts for radiation belt variability and geometry.

Virani, S. N.↗

Remote, unattended, forest fire detector

Instruments for land tract scanning and fire detection include: temperature sensor capable of detecting distant match flame; elevated television camera with automatic controls for light balance, position, filter, and focus; and scanner equipped with photocell to sense intensity of flying spot brought to it by sweep-and-scan mechanism.

Winslow, D. J.↗

Implementation of the HEP instrumentation R&D roadmap in the USA

In recent years, the High Energy Physics (HEP) community in the USA has evaluated the technological needs in detector instrumentation for future HEP experiments. Specific needs have been identified and an R&D program to reach them has been defined. This article will briefly summarize the planning process and will highlight the main findings and the road map to carry out the plan as defined by the community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Helical channel multiplier package design for space instrumentation

The package considered is intended for the channel electron multiplier (CEM) detectors which are to be used for the extreme ultraviolet telescope and helium glow detector instruments of the Apollo-Soyuz test project. In the package design selected, the cone of the CEM is supported at the front end by a silicone rubber ring which is molded in place and self-bonded to both the cone and the housing wall. The helix is supported and insulated from the housing by a fiber glass sleeve which is bonded to the inside of the housing.

Hoshiko, H. H.↗

Integration of a Micro-Chip Amino Acid Chirality Detector into the MOD Instrument Concept

The MOD (Mars Organic Detector) instrument concept consists of a sublimation apparatus for organic compound isolation connected to a microfabricated microfluidic analyzer containing a sipper, pumps and a separation channel for organic compound characterization. The target organic compounds are amino acids and polycyclic aromatic hydrocarbons (PAHs). Solid samples are placed within the sublimation apparatus and heated to release organic compounds which sublime onto a cold finger. Half of the cold finger is coated with fluorescamine. which reacts with amino acids and other primary amines to generate an intense fluorescent derivative while the other half is uncoated and is used to directly detect PAH fluorescence, A capillary sipper is then used to dissolve and sample the labeled amino acids and integrated microfabricated pumps transport the labeled amino acids to the chip for analysis. The sample is separated using capillary zone electrophoresis (CZE) together with chiral dextrins to determine amino acid composition and chirality. During the grant period, the following steps have been completed toward the development of a robust instrument and chemistry.

Bada, Jeffrey L.↗

Design, fabrication, and dynamic testing of a V-groove radiator mechanical development unit

This paper describes the design, fabrication, and dynamic testing of a V-groove radiator development unit. The intended goal was to survive the dynamic environment of the Mars Observer mission. The development unit was designed to achieve a temperature of 80 K with a heat load of about 80 milliwatts. An analysis was performed to predict the thermal performance of the development unit. The radiator with a mass mockup of a Gamma Ray Spectrometer detector, the most massive of the candidate Mars Observer instrument detectors (1.7 Kg), passed vibration and acoustic testing to the Mars Observer requirements in effect at that time.

Petrick, S. Walter↗

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record↗

A Thermal Imaging Instrument with Uncooled Detectors

In this work, we performed an instrument concept study for sustainable thermal imaging over land with uncooled detectors. We evaluated two different uncooled detector technologies uncooled microbolometers and thermopiles. We have also evaluated materials for use in in a uncooled thermopile detector concept.

Thermal↗