Wire insulation degradation and flammability in low gravity

This view-graph presentation covers the following topics: an introduction to spacecraft fire safety, concerns in fire prevention in low gravity, shuttle wire insulation flammability experiment, drop tower risk-based fire safety experiment, and experimental results, conclusions, and proposed studies.

Friedman, Robert↗

Dielectric films improve life of polymeric insulators

Degradation of polymeric insulators may be significantly reduced when polymer surfaces are coated with film having gradation of dielectric constants, larger where it is in contact with polymer and smaller at its exposed surface.

Hudis, M.↗

Insulation Resistance Degradation in Ni-BaTiO3 Multilayer Ceramic Capacitors

Insulation resistance (IR) degradation in NiBaTiO3 multilayer ceramic capacitors has been characterized by the measurement of both time to failure (TTF) and direct current leakage current as a function of stress time under highly accelerated life test conditions. The measured leakage current time dependence data fit well to an exponential form, and a characteristic growth time tau (sub SD) can be determined. A greater value of tau (sub SD) represents a slower IR degradation process. Oxygen vacancy migration and localization at the grain boundary region results in the reduction of the Schottky barrier height and has been found to be the main reason for IR degradation in NiBaTiO3 capacitors. The reduction of barrier height as a function oftime follows an exponential relation of phi (t ) = phi (0) e (exp -2Kt), where 13 the degradation rate constant K Koe (Ek/kT) is inversely proportional to the mean TTF (MTTF) and can be determined using an Arrhenius plot. For oxygen vacancy electromigration, a lower barrier height phi (0) will favor a slow IR degradation process, but a lower phi (0) will also promote electronic carrier conduction across the barrier and decrease the IR. As a result, a moderate barrier height phi (0) (and therefore a moderate IR value) with a longer MTTF (smaller degradation rate constant K) will result in a minimized IR degradation process and the most improved reliability in NiBaTiO3 multilayer ceramic capacitors.

reliability↗

Insulation Resistance Degradation in Ni-BaTiO3 Multilayer Ceramic Capacitors

Insulation resistance (IR) degradation in Ni-BaTiO3 multilayer ceramic capacitors has been characterized by the measurement of both time to failure and direct-current (DC) leakage current as a function of stress time under highly accelerated life test conditions. The measured leakage current-time dependence data fit well to an exponential form, and a characteristic growth time SD can be determined. A greater value of tau(sub SD) represents a slower IR degradation process. Oxygen vacancy migration and localization at the grain boundary region results in the reduction of the Schottky barrier height and has been found to be the main reason for IR degradation in Ni-BaTiO3 capacitors. The reduction of barrier height as a function of time follows an exponential relation of phi (𝑡)=phi (0)e(exp -2Κt), where the degradation rate constant 𝐾=𝐾o𝑒(𝐸𝑘/𝑘𝑇) is inversely proportional to the mean time to failure (MTTF) and can be determined using an Arrhenius plot. For oxygen vacancy electromigration, a lower barrier height phi(0) will favor a slow IR degradation process, but a lower phi(0) will also promote electronic carrier conduction across the barrier and decrease the insulation resistance. As a result, a moderate barrier height phi(0) (and therefore a moderate IR value) with a longer MTTF (smaller degradation rate constant 𝐾) will result in a minimized IR degradation process and the most improved reliability in Ni-BaTiO3 multilayer ceramic capacitors.

dielectric degradation↗

Nondestructive Evaluation of Aircraft and Spacecraft Wiring

Spacecraft, and especially aircraft, often fry well past their original design lives and, therefore, the need to develop nondestructive evaluation procedures for inspection of vital structures in these craft is extremely important. One of the more recent problems is the degradation of wiring and wiring insulation. The present paper describes several nondestructive characterization methods which afford the possibility to detect wiring and insulation degradation in-situ prior to major problems with the safety of aircraft and spacecraft.

White, John E.↗

Cryogenic Moisture Apparatus

The Cryogenic Moisture Apparatus (CMA) is designed for quantifying the amount of moisture from the surrounding air that is taken up by cryogenic-tank-insulating material specimens while under typical conditions of use. More specifically, the CMA holds one face of the specimen at a desired low temperature (e.g., the typical liquid-nitrogen temperature of 77 K) while the opposite face remains exposed to humid air at ambient or near-ambient temperature. The specimen is weighed before and after exposure in the CMA. The difference between the "after" and "before" weights is determined to be the weight of moisture absorbed by the specimen. Notwithstanding the term "cryogenic," the CMA is not limited to cryogenic applications: the low test temperature can be any temperature below ambient, and the specimen can be made of any material affected by moisture in air. The CMA is especially well suited for testing a variety of foam insulating materials, including those on the space-shuttle external cryogenic tanks, on other cryogenic vessels, and in refrigerators used for transporting foods, medicines, and other perishables. Testing is important because absorbed moisture not only adds weight but also, in combination with thermal cycling, can contribute to damage that degrades insulating performance. Materials are changed internally when subjected to large sub-ambient temperature gradients.

Fesmire, James↗

Insights Developed Into the Damage Mechanism of Teflon FEP Thermal Control Material on the Hubble Space Telescope

Metalized Teflon FEP (DuPont; fluorinated ethylene propylene) thermal control material on the Hubble Space Telescope (HST) has been found to degrade in the space environment. Teflon FEP thermal control blankets retrieved during the first servicing mission were found to be embrittled on solar-facing surfaces and to contain microscopic cracks (the FEP surface is exposed to the space environment). During the second servicing mission, astronauts noticed that the FEP outer layer of the multilayer insulation blanketing covering the telescope was cracked in many locations. Large cracks were observed on the light shield, forward shell, and equipment bays. A tightly curled piece of cracked FEP from the light shield was retrieved during the second mission. This piece was severely embrittled, as witnessed by ground testing. A Failure Review Board was organized by NASA Goddard Space Flight Center to determine the mechanism causing the multilayer insulation degradation. This board included members of the Electro-Physics Branch of the NASA Glenn Research Center at Lewis Field. Density measurements of the retrieved materials obtained under the review board's investigations indicated that FEP from the first servicing mission was essentially unchanged from pristine FEP but that the second servicing mission FEP had increased in density in comparison to pristine FEP (ref. 1). The results were consistent with crystallinity measurements taken using x-ray diffraction and with results from solid-state nuclear magnetic resonance tests (see the table and ref. 1). Because the second servicing mission FEP was embrittled and its density and crystallinity had increased in comparison to pristine FEP, board researchers expected that the first servicing mission FEP, which was also embrittled, would also have increased in crystallinity and density, but it did not. Because the retrieved second servicing mission material curled while in space, it experienced a higher temperature extreme during thermal cycling (estimated at 200 C) than the first servicing mission material (estimated at 50 C). Therefore, Glenn initiated and conducted an investigation of the effects of heating pristine FEP and FEP that had been exposed on the Hubble Space Telescope. Samples of pristine and first and second servicing mission FEP were heated to 200 C and evaluated for changes in density and morphology. We hoped that the results would help explain why FEP degrades in the Hubble Space Telescope space environment.

deGroh, Kim K.↗

Development and validation of cryogenic foam insulation for LH2 subsonic transports

Fourteen foam insulation specimens were tested. Some were plain foam while others contained flame retardants, chopped fiberglass reinforcement and/or vapor barriers. The thermal performance of the insulation was determined by measuring the rate at which LH2 boiled from an aluminum tank insulated with the test material. The test specimens were approximately 50 mm (2 in.) thick. They were structurally scaled so that the test cycle would duplicate the maximum thermal stresses predicted for the thicker insulation of an aircraft liquid hydrogen fuel tank during a typical subsonic flight. The simulated flight cycle of approximately 10 minutes duration heated the other insulation surface to 316 K (110 F) and cooled it to 226 K (20 F) while the inner insulation surface remained at liquid hydrogen temperature of 20 K (-423 F). Two urethane foam insulations exceeded the initial life goal of 2400 simulated flight cycles and sustained 4400 cycles with only minor damage. The addition of fiberglass reinforcement of flame retardant materials to an insulation degraded thermal performance and/or the life of the foam material. Installation of vapor barriers enhanced the structural integrity of the material but did not improve thermal performance. All of the foams tested were available materials; none were developed specifically for LH2 service.

Anthony, F. M.↗

Cathode and insulator materials for a 30 kW arcjet thruster

This paper describes past experience with 30 kW arcjet engines, emphasizing the operational parameters pertinent to the selection of new/alternate erosion-resistant materials to enhance lifetime. Mechanisms of mass loss from the electrodes and insulators are suggested, and ways of identifying potential processes for controlling cathode erosion and insulator degradation are proposed. The limitations of present materials used in critical arcjet thruster components are described. An outline is given of the criteria and the figure of merit on which the selection of candidate materials can be based. Potentially useful new/alternate materials are listed based on available thermophysical and other material properties.

Sokolowski, Witold↗

Operational environments for electrical power wiring on NASA space systems

Electrical wiring systems are used extensively on NASA space systems for power management and distribution, control and command, and data transmission. The reliability of these systems when exposed to the harsh environments of space is very critical to mission success and crew safety. Failures have been reported both on the ground and in flight due to arc tracking in the wiring harnesses, made possible by insulation degradation. This report was written as part of a NASA Office of Safety and Mission Assurance (Code Q) program to identify and characterize wiring systems in terms of their potential use in aerospace vehicles. The goal of the program is to provide the information and guidance needed to develop and qualify reliable, safe, lightweight wiring systems, which are resistant to arc tracking and suitable for use in space power applications. This report identifies the environments in which NASA spacecraft will operate, and determines the specific NASA testing requirements. A summary of related test programs is also given in this report. This data will be valuable to spacecraft designers in determining the best wiring constructions for the various NASA applications.

Stavnes, Mark W.↗

STS-82 Flight Day 07 Highlights

The seventh day of the STS-82 mission begins with the crew, Commander Kenneth D. Bowersox, Pilot Scott J. Horowitz, Payload Commander Mark C. Lee, and Mission Specialists Gregory J. Harbaugh, Steven L. Smith, Joseph R. Tanner, and Steven A. Hawley performing their third spacewalk of the mission by emerging from Discovery's airlock. Their first task is the replacement of a Solar Array Drive Electronics package which is used to control the positioning of Hubble's solar arrays. Harbaugh and Tanner next venture to the top of the telescope where they replaced covers over Hubble's magnetometers, which are used to sense the telescope's position in relation to the Earth through data acquired from the Earth's magnetic field. The spacewalking astronauts then place thermal blankets of multi-layer material over two areas of degraded insulation around the light shield portion of the telescope just below the top of the astronomical observatory.

Source record↗

Degradation of a Multilayer Insulation Due to a Seam and a Penetration

The degradation of the thermal performance of a multilayer insulation due to the presence of a seam and a penetration was studied. The multilayer insulation had 30 aluminized Mylar radiation shields with silk net spacers. The seam, an offset butt joint, caused a heat input of 0.169 watt per meter in addition to the basic insulation thermal performance of 0.388 watt per square meter obtained before the installation of the butt joint. The penetration, a fiberglass tank support strut, provided a heat input (including the degradation of the insulation) of 0.543 watt in addition to the basic insulation thermal performance of 0.452 watt per square meter obtained before the penetration.

Sumner, I. E.↗

A test and instrumentation system for the investigation of degradation of electrical insulating materials

A comprehensive test apparatus has been developed for the evaluation of the effects of thermal cycling, high temperatures and high electric fields on the quality and stability of electrical insulating materials used in spacecraft systems. The system includes a test chamber in which the specimen can be subjected to thermal and electrical stresses encountered in the space environment (temperatures from -50 to 200 C and voltages from 0 to 10 kV rms, respectively) simultaneously. The system instrumentation includes provisions for the measurement of the change in capacitance, the thermal dissipation factor of the material, and complex dielectric constants with changes in temperature, corona intensity and voltages at frequencies from 22 kHz to 70 MHz, as well as the volume and surface resistivities of the materials.

Doreswamy, C. V.↗

Development of techniques and instrumentation for the nondestructive evaluation of multi-layer insulation

The development of techniques and instrumentation suitable for the nondestructive evaluation of purged multilayer insulation prior to and after a shuttle orbiter flight is discussed. These techniques are desirable because of the possibility that corrosion, compression, or tearing of the insulation will degrade the performance of the insulation during subsequent flights. A second objective was the application of the developed technology to the evaluation of other insulation types. Three nondestructive evaluation techniques, electromagnetic, thermal, and acoustic were selected for evaluation. The results of evaluation of each technique are described.

Source record↗

Joining lead wires to thin platinum alloy films

A two step process of joining a lead wire to .000002 m thick platinum alloy film which rests upon an equally thin alumina insulating layer which is adhered to a metal substrate is described. Typically the platinum alloy film forms part of a thermocouple for measuring the surface temperature of a gas turbine airfoil. In the first step the lead wire is deformed 30 to 60% at room temperature while the characteristic one million ohm resistance of the alumina insulating layer is monitored for degradation. In the second step the cold pressed assembly is heated at 865 to 1025 C for 4 to 75 hr in air. During the heating step any degradation of insulating layer resistance may be reversed, provided the resistance was not decreased below 100 ohm in the cold pressing.

Przybyszewski, J. S.↗