Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integrated Demand Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

Early Research in Load-Following Management for HPC-Nuclear Integration

With the rising demand for high performance computing (HPC) and artificial intelligence (AI) systems, maintaining a stable and efficient power supply is increasingly critical. The HPC team at Idaho National Laboratory is spearheading efforts to seamlessly integrate HPC systems with nuclear reactors. This lightning talk explores one early strategy for managing power fluctuations using software-defined controls. To effectively harness nuclear reactors for power generation, control mechanisms are essential to address the slow load-following capabilities of reactors, which are typically around 5% per minute. While this rate is sufficient for many uses, large HPC systems can experience rapid power consumption changes by tens of megawatts when jobs start or stop running. A reactor could overproduce power and match the peak power rating for the HPC system, however when the system is not running a job or a job unexpectedly stops, the load-following of the system would be affected leading to power being wasted and the likelihood of power transient occurrences increases. Controlling the increase or decrease of power consumption on these systems at the same rate as the load-following of reactors is one piece of the puzzle to properly utilizing nuclear reactors as a power source for HPC systems.

97 - MATHEMATICS AND COMPUTING↗

Optimized V1G and V2G Electric Vehicle Fleet Management and Grid Transaction at Marine Corps Air Station Miramar in San Diego, CA

The overall technical goal of the project was to demonstrate an all-electric bi-directional non-tactical fleet at Marine Corps Air Station (MCAS) Miramar that was integrated and controlled with other distributed energy resources (DERs) (i.e., PV, stationary battery, and building loads) to provide resilience to critical electric loads in the event of grid outages, to minimize charging costs, and to provide economic energy resources to electricity markets. In this project, the specific, technical objectives were: 1. Demonstrate that bi-directional electric vehicles can provide critical complementary services to fixed storage batteries in microgrid applications while performing function as non-tactical vehicles. 2. Demonstrate participation of bi-directional (V2G) and unidirectional (V1G) PEVs for demand management and minimization of charging costs. 3. Demonstrate integration of multiple DERs for grid service participation. US Marine Corps Air Station (MCAS) Miramar in San Diego was the site of this electric vehicle-to-microgrid-utility grid test and demonstration project. Existing microgrid assets in this study included (1) a public works building; (2) a 30-kW rooftop photovoltaic (PV) system and (3) a separate 250 kW carport PV system. In this project, six bi-directional V2G vans were located at the MCAS Miramar’s showcase building-scale microgrid to develop and test technical capabilities that V2G can provide in microgrid applications (e.g., cost reduction and resiliency). These resources provided aggregated demand management and simulated participation in current retail DR programs. The vehicles used in this demonstration were selected because they provided functionality that MCAS Miramar needed, 15 passenger transport and facilities work cargo carrying capacity, and bi-directional charging capability that the research project required. All vehicles in this study were manufactured and distributed by VIA Motors, Inc. There were six vehicles total and each was VIA’s VTRUX eREV V2G model, a modified General Motors Chevrolet 2500 2WD van. Three of the vans were configured as passenger vans and the other three were configured as cargo vans. Each van had an on-board bi-direcrtional inverter/charger, Bel Power Solutions model 350INVCHGT150-120-240-8G nominally rated at +/-15 kW. The VIA van’s charging connector follows the J1772 charging protocol. The bi-directional EVSEs demonstrated in this study were manufactured by Coritech, Inc. Each VGI-80-AC charging station enabled enhanced V2G charging capability to a Clipper Creek CS-100 charging module. The enhanced capabilities included ethernet communication following the SEP2.0 protocol with a distributed energy resource function set and an operator screen displaying real-time SOC, voltage, and current. The VGI-80-AC charging stations are classified as level 2 with a maximum current output of 80 A or effectively 19 kW. The VIA van’s onboard charger limited the charging and discharging power to 15 kW in each direction. A control computer was installed in the EWOC and connected to an existing monitor. The V2G control communication network was a completely stand-alone closed system that did not have any connection to any other networks on the base. A cybersecure remote communication connection was created with a cellular modem, firewall hardware, and a virtual private network configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Plug-in Electric Vehicle Charging Response Characterization for Grid Integration: Implications for Smart Charge Management

The rapid expansion of plug-in electric vehicles (PEVs) has created a unique challenge for electrical grids due to their significant power demand. At the same time, PEVs also create a unique opportunity to ease their own burden on the power grid, as they create a growing fleet of distributed energy resources capable of providing grid services such as demand response, frequency regulation, and renewable balancing. For aggregators and grid operators to effectively integrate PEVs into grid management, it is essential to first understand and characterize how they would respond in such situations. This study examines 25 models of PEVs across 25 makes, spanning model years from 2013 to 2025, to characterize their responses to the basic controls used in vehicle-grid integration (VGI): stopping, starting, and modulating the charge rate. Each vehicle was tested in a controlled laboratory setting to evaluate its performance in response to varying the maximum allowable current via the SAE J1772 control pilot signal, as well as its response to wake-up commands outlined in SAE J1772. Results show measurable differences across vehicle makes in the accuracy, latency, and precision with which PEVs respond to changes in ampacity, as well as varying sleep and wake-up behavior. The test results show that all vehicles respond to changes in ampacity, though with varying accuracy, precision, latency, and resolution. Wake-up behavior also differs across makes and models. These findings indicate that effective grid integration strategies must account for these differences. The results provide a foundation for understanding current vehicle behavior and advancing smart-charging methods while also highlighting the need for further testing, broader standardization, and manufacturer collaboration to ensure the successful integration of PEVs into the electrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing thermal comfort and participation in residential demand flexibility programs

Residential space-conditioning-based demand flexibility (DF) has become an increasingly sought-after method for demand-side load management to enhance grid reliability and facilitate integration of renewable energy generation. However, predicting the effectiveness and flexibility of residential DF resources is challenging due to the variability in household energy use behaviors. Current estimates show that only 50 % of projected savings from DF resources are actualized due to regulatory, technological, and social barriers. From a household perspective, concerns over thermal comfort during space conditioning-based DF events significantly impact participation decisions. Currently, there is a very limited understanding of how thermal comfort during space-conditioning-based DF events in real-world settings impacts household energy use behaviors and, consequently, the success of DF programs in achieving targeted savings. This paper proposes a method to comprehensively assess the thermal comfort implications of DF strategies and presents results of their impacts on DF event participation decisions and demand savings. Here, the proposed method was applied to a heat pump DF field study in Cordova, Alaska. The study’s key findings are: 1) DF event setpoint offsets that maintain indoor operative temperatures between 18 to 22 °C (65 to 71°F) may be preferred in Cordova, Alaska; 2) Household-level thermal comfort is more sensitive to the duration of the DF event than to the degree of temperature offset from baseline conditions; 3) The delayed impact of changes in indoor operative temperature in response to setpoint offsets, both during and after a DF event, influences occupants’ thermal comfort perceptions and willingness to persistently participate in events. The findings from application of the proposed method can help inform future larger-scale occupant-centric DF programs as it can capture information not readily available through utility and device-level energy use data. Thus, it can supplement these sources and help program administrators develop occupant-centric DF strategies, enabling more accurate predictions of participation rates and savings estimates for space-conditioning-based DF programs.

Demand side management↗

Accelerating Nuclear-Integrated Data Centers in the USA: SWOT Analysis, Power-Thermal Management Strategies, and Industrial-Scale Demonstration and Potential Deployment

Driven by the growth in digital services, cloud computing, AI, and manufacturing, data centers face rising energy demands that challenge traditional power sources and cooling efficiency. This study explores using nuclear power to meet these demands, focusing on accelerated reactor technology deployment and highlighting needs such as N+1/N+2 power supplies and integrated power-thermal management. A SWOT analysis addresses grid connectivity, reactors, and site selection, particularly DOE sites. Reactor technology demonstration and deployment could be accelerated by leveraging test facilities such as MARVEL, MAGNET, TED, FAS, DOME, LOTUS, ATR, Energy System Proving Grounds, and upcoming Energy Launch Pads, along with modeling and simulation tools such as RELAP5, MOOSE, VERA, RAVEN, and FORCE. The potential power and thermal management options, including various cooling technologies, waste-heat utilization, and an industrial-scale demonstration plan, aim to accelerate the integration of nuclear power and data centers in the USA, while emphasizing community and stakeholder engagement and synergistic efforts.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Performance Assessment of a Heat Pump Integrated with Thermal Energy Storage in Cooling & Heating Modes

Thermal Energy Storage (TES) systems have demonstrated significant potential to manage the fluctuating nature of energy demand and shifting peak loads. This technology has made significant recent advances, including new research on the integration of TES with residential and commercial Heating, Ventilation, and Air-Conditioning (HVAC) systems. In this paper, we present the use of a novel laboratory assessment framework for a prototype heat pump system integrated with latent heat phase change material-based TES. The assessment framework consists of 22 total test points (11 heating, 11 cooling) using psychrometric conditions from AHRI Standard 210/240 and includes transient conditions to evaluate TES charging and discharging modes. In addition, both continuous mode and cyclic mode were evaluated for charging and discharging to explore the benefits to TES heat transfer from repeated transient operation. The ambient conditions evaluated include heating mode charging at cold-climate heat pump conditions when winter-peaking utilities may most require demand reduction (H4Full conditions, 5°F/-15°C) and cooling mode charging at high ambient temperature that may occur during times of day when excess solar power generation results in low-cost electricity (105°F/40.6°C). The work demonstrates the demand reduction capabilities of integrating TES with HVAC, including up to 44% in cooling mode and 60% in heating mode compared to conventional HVAC equipment without TES.

25 ENERGY STORAGE↗

A Forward-Looking Dataset of EV Managed Charging Resource and Costs

This presentation summarizes a high-resolution, forward-looking dataset of EV adoption, EV charging, and managed charging resource. Vehicle-level data are grounded in current adoption and charging patterns, and ~200,000 real-world vehicle-weeks of travel data covering all on-road segments (i.e., light-duty, transit and school buses, local, regional and long-haul medium- and heavy-duty). The data, which include multiple charging profiles per vehicle to bound flexibility, are then processed and aggregated to describe baseline charging and charge management resource by county, hour, year, scenario, and vehicle type. Coupled with one of four scenarios of how EV managed charging costs might evolve over time, the dataset enables a power sector capacity expansion model to select cost-optimal quantities of EV managed charging and supply-side resources to reliably satisfy demand. Five integration strategies: Baseline, Daytime and Flat (passive), Flex (active), and Stress (anti-strategy), illustrate how baseline charging and flexibility potential changes with EVSE build-out and charging preferences.

33 ADVANCED PROPULSION SYSTEMS↗

Accelerating nuclear-integrated data center pursuits in the USA: SWOT analysis, power-thermal management strategies and demonstration plan

Here, this study explores the increasing interest in leveraging nuclear power to meet the escalating energy demands of data centers in the United States (U.S.) by focusing on key factors that contribute to accelerated deployment. The study highlights the importance of N+1/N+2 power supplies (where N is the required number of units), outlines research and innovations in nuclear-integrated data center thermal management and demonstration plan. It also provides updates about status and costing of various reactor system designs. A summarized strengths, weaknesses, opportunities, and threats (SWOT) analysis shows the potential options for grid connectivity, reactors, and site selection. Suitable site discussions consider land and water availability, grid access, and optical fiber connectivity, and the study presents graded prospects for Department of Energy (DOE) sites with a specific example. Community engagement and partnerships are emphasized, particularly the roles of local government, federal agencies, utilities, and data center industry partners, which are crucial for accelerating deployment, business outreach, and approvals. The study provides actionable insights for stakeholders to accelerate the deployment of nuclear-powered data centers.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

EV Forecasting-Based Model Predictive Control for Distribution System Congestion Mitigation

The uncoordinated charging of electric vehicles (EVs) in time and space brings congestion issues to the distribution network. This paper proposes an EV charging demand forecasting-based model predictive control (MPC) method for distribution system congestion management. To effectively forecast the time-series EV station charging demand, a hybrid forecasting model that integrates the long short-term memory network (LSTM) and Transformer is proposed. The Transformer-LSTM model is trained using a one-year real historical charging dataset of EV stations to forecast future charging demand in 15-minute intervals. This informs the MPC for distribution network congestion management and minimization of PV curtailment. Numerical results carried out on the modified IEEE 123-bus distribution system demonstrate that the proposed method can effectively resolve line congestion issues through EV smart charging and PV curtailment while outperforming other benchmarks.

ADVANCED PROPULSION SYSTEMS,SOLAR ENERGY↗

Low-cost buffer storage for solar industrial steam applications

Motivation and importance: Many industrial process heat consumers operate throughout the day, and deep decarbonization with solar energy requires thermal energy storage. Thermal energy storage provides an additional operational benefit of firm delivery of steam – essential to reducing the risk of costly production interruptions. The group of process heat consumers that use steam for biofuels production for the California transportation fuels market is incentivized through the Low Carbon Fuel Standard (LCFS) to reduce their carbon intensity through the use of solar steam. Examples include ethanol and dimethyl ether production. The production of these and other fuels involves distillation driven by steam reboilers with steam pressures in the range 100-280 psig. These pressures can be delivered from the type of thermal energy storage that has been the focus of this project – a steam accumulator Sunvapor, Inc. (SVI) calls a “Bullet Steam Accumulator” or “BSA TM ”. Our project adds to the understanding of the design and integration of steam accumulators charged by solar thermal energy in a biofuels production facility, and similar facilities that consume process steam. The fuel application requires a demanding level of Process Safety Management not found in other steam applications. The type of steam accumulator SVI engineered and built integrates steam generation and storage in one vessel to reduce cost. Achieving a first of a kind permit to operate such a first device has also added to the understanding of the industrial application of such systems. Goals: The overall goal of the project has been to demonstrate the advantages that a “Bullet Steam Accumulator” (BSA™) can provide to solar steam integration with a manufacturing process. The industrial host has already been convinced of the potential of the available solar steam to lower than carbon intensity score. They have been interviewed for a number of publications such as that tout the advantages SVI’s system brings to their operations. Accomplishments: At the end of 2023 Sunvapor placed in service the country’s first industrial solar boiler with thermal energy storage. At the same time, this placement in service represents the first pilot commercial system to decarbonize biofuels production through the use of solar thermal energy. While the full technical effectiveness will be shown as soon as the customer’s plant is able to consume the available steam, the economic feasibility was indicated early in the project when the combination of costs and steam pricing required to meet investor expectations was determined. The project represents a reference pilot from which a full-scale commercial system may be expanded. This pilot is a necessary first step in providing the full potential benefits to the public, including decarbonization of transportation fuels. The decarbonization of the separation steps in fuels production may be the most cost-effective and nearest term solar fuel. Co-benefits include a reduction of air pollutants such as NOx and particulate matter, and job creation for the construction, operation and maintenance of industrial solar facilities.

14 SOLAR ENERGY↗

Unified Modeling Architecture for Load Management in Extreme Heat: The New York City Case

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on this key subject by assessing the feasibility of using coastal-urban renewable energy resources, namely, offshore wind and rooftop photovoltaic systems, to meet electricity demand of New York City during the intense recent heat wave period of June 2025. A unified modeling framework, based on the urbanized weather research and forecasting model, is used to simulate climate, renewable resources, and energy demand variables. Findings show significant energy load mismatch of approximately 1150 GWh over the month, between the demand and the combined renewable generation outcome. Three storage integration scenarios are analyzed to mitigate the deficits, reducing said deficits by a minimum of approximately 9% over the duration of the month. This study provides a transferable modeling framework tool for evaluating renewable integration in dense urban environments that can be used by grid operators to support grid resilience during extreme heat events.

54 ENVIRONMENTAL SCIENCES↗

Multi-parametric analysis for mixed integer linear programming: An application to transmission upgrade and congestion management

Upgrading the capacity of existing transmission lines is essential for meeting the growing energy demands, facilitating the integration of renewable energy, and ensuring the security of the transmission system. This study focuses on the selection of lines whose capacities and by how much should be expanded from the perspective of the Independent System Operators (ISOs) to minimize the total system cost. We employ advanced multi-parametric programming and an enhanced branch-and-bound algorithm to address complex mixed-integer linear programming (MILP) problems, considering multi-period time constraints and physical limitations of generators and transmission lines. To characterize the various decisions in transmission expansion, we model the increased capacity of existing lines as parameters within a specified range. This study first relaxes the binary variables to continuous variables and applies the Lagrange method and Karush-Kuhn-Tucker (KKT) conditions to obtain optimal solutions and identify critical regions associated with active and inactive constraints. Moreover, we extend the traditional branch-and-bound (B&B) method by determining the problem’s upper and lower bounds at each node of the B&B decision tree, helping to manage computational challenges in large-scale MILP problems. Here, we compare the difference between the upper and lower bounds to obtain an approximate optimal solution within the decision-makers’ tolerable error range. In addition, the first derivative of the objective function on the parameters of each line is used to inform the selection of lines for easing congestion and maximizing social welfare. Finally, the capacity upgrades are selected by weighing the reductions in system costs against the expense of upgrading line capacities. The findings are supported by numerical simulations and provide transmission-line planners with decision-making guidance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Managing Increased Electric Vehicle Shares on Decarbonized Bulk Power Systems

Transportation electrification and power sector decarbonization - the convergence of these two trends present a complex planning problem requiring realistic, region-specific modeling and analysis to ensure that both can happen rapidly and cost effectively. This project, funded through the U.S. Department of Energy's Vehicle Technologies Office, models the evolution of the U.S. bulk power system (through 2050) in response to large-scale EV charging across all on-road vehicle segments. We will assess the opportunity and value of demand-side flexibility (i.e., "smart" charging) for reducing energy costs, increasing renewable generation shares, and managing future EV loads on the bulk power system. Overall, this study aims to provide an improved understanding of least-cost solutions for managing EV load growth on the grid and will make high-resolution EV load data sets publicly available for further analysis.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Cost-optimized energy storage operation for a grid-connected solar PV system at community and individual scales

This study provides a comparative analysis of grid-connected PV-integrated battery storage at individual and community scales. The paper addresses the challenge of managing energy demand-generation mismatch by using a battery energy storage optimization algorithm, which minimizes operational costs while accounting for battery degradation. Also, this work introduces a broader evaluation basis that includes seasonal variability, grid exchange smoothness, and scalability across different battery capacities. Results show that community-scale storage more effectively dampens grid exchange power fluctuations and reduces system costs, particularly with moderate price differences between electricity buying and selling prices and low battery capacities. The paper also analyzes the impacts of static control versus cost-optimized battery system management. Here, it is shown that the gap in system costs between the cost-optimized and static control scenarios widens as the price difference increases.

25 ENERGY STORAGE↗

Integrating Electric Vehicles into the Grid

Historically, transportation and power systems operated independently, but the rise of electric vehicles is transforming this relationship. In the United States, EV demands are expected to become the largest source of electricity load growth, posing challenges for the grid if not properly managed. This presentation highlights how managed charging strategies and strategic infrastructure deployment can integrate EVs into the power system to enhance grid efficiency and support renewable energy.

ADVANCED PROPULSION SYSTEMS,DIRECT ENERGY CONVERSI↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Distribution System Congestion Management - A Survey of Reliable Integration for Aggregated Resources and Microgrids

Rising penetration of consumer-owned Distribution Grid Resources (DGRs), increasingly managed by third party aggregators and enrolled in grid services and wholesale market programs, can create localized congestion in distribution networks. Managing these constraints is challenging due to a persistent coordination and information gap: utilities are accountable for reliability and have network topology and state visibility, while aggregators control the DGR capability needed to relieve congestion. This survey synthesizes congestion management solutions for distribution systems with high DGR penetration, covering both market-based mechanisms (distribution level markets, locational pricing, flexibility auctions) and non-market-based solutions (network reconfiguration, direct DGR control, demand response, curtailment, etc.). The literature is organized across three decision horizons: long term planning, operational planning, and real-time operation. Special attention is devoted to emerging distribution system operator architectures and coordination frameworks spanning transmission system operators, aggregators, and microgrids. Drawing on recent case studies and implementations, we distill best practices, identify key technical and economic barriers, and outline research directions. The evidence points to a shift toward integrated congestion management that combines market signals with technical controls, enabled by improved monitoring, forecasting, and closed loop control capabilities.

Active Distribution Networks (ADN)↗