Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integrated Science Instrument Module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

On the Development of Compact HTS Coil Modules for Large Bore High Field Superconducting Magnets

Lower cost, high current density superconducting coil modules producing higher magnetic fields and cooled affordably are crucial for obtaining cost-effective, compact commercial fusion reactors. Accessibility to low cost, higher field magnets (>30 T) is also critical for the discovery of new quantum phenomena in materials, cosmic frontier and other topics in basic science research. The Princeton Plasma Physics Laboratory (PPPL) is working with Princeton University to develop unique large bore, compact superconducting magnets to support science experiments including the development of new instrumentation for condensed matter physics and Axion dark matter search in the cosmic frontier. Core elements of these experiments are unique for access to lower cost, simple fabrication of compact superconducting magnets that can be cooled affordably, while integrated with dedicated science instruments. Conductor qualification and coil design concepts are discussed in support of needs for these experiments. PPPL has the unique expertise and experimental facilities to design, construct and test subscale coil modules for these projects. Compact high field coil modules were fabricated and tested to validate coil design concepts and coil performance. Finally, the design and model coil integration challenges are discussed to identify performance risks and demonstrate feasibility for deploying full scale large bore compact superconducting magnets for cost effective operations of multiple laboratory experiments.

axion dark matter↗

Evaluating the performance of a high resolution SLIM IM module integrated with an Agilent 6560 IM-QTOF MS

Integrate a combined Structures of Lossless Ion Manipulations (SLIM) module that incorporates both constant (not time-varying) field (CF) and oscillatory (time-varying) field (OF) IM separation stages into an Agilent 6560 IM-QTOF mass spectrometer system. Once the SLIM module has been integrated into the Agilent system, its performance will be evaluated using a variety of different samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selection of Components for the Remote, Canister-Monitoring System

This report documents the selection of components as part of the efforts initiated to develop a remote, canister-monitoring system (RCMS) for determining and monitoring environmental conditions within dry fuel storage canisters containing aluminum clad spent nuclear fuel (ASNF) at the Idaho National Laboratory (INL). These efforts are in support of Department of Energy Office of Environmental Management (DOE-EM) investigations into technical issues associated with extended dry storage (50+ years) of ASNF. The capability to establish and monitor the performance of ASNF in situ provides the opportunity to (1) evaluate the appropriate technologies for monitoring, (2) collect canister environment conditions as soon as possible, (3) verify and validate current laboratory-based study results and analytic modeling approaches, and (4) potentially identify additional dry storage options for ASNF at the INL site. The improved understanding of ASNF behavior gained by performing this work would also contribute to the safety basis for extended dry storage in current and future configurations as well as to provide information for future transportation, conditioning, and disposal of ASNF. The parameters to be monitored by the RCMS include temperature, relative humidity, hydrogen gas concentration and radiation environment (dose). Components are selected based on the expected environmental conditions within the canister and fuel storage area, and the desired performance of the RCMS. Several of these components have been purchased and received. Future activities include component testing and calibration, software development for operation of the integrated sensor module and fabrication of a representative test volume. The results of these tests and changes to desired performance characteristics will inform subsequent activities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Implementation of a Time-domain Cosmic-ray-muon Tagger for the NEXUS Low-background Cryogenic Facility

Quantifying the effects of radiation on the operation of qubits both as quantum information systems as well as particle detectors has emerged as a pressing issue in quantum science in recent years. We present an overview of the design, operation, and deployment of a 90-$\mathrm{in}^2$ three-panel muon detector for use in the NEXUS experimental facility at Fermilab to temporally isolate correlated errors in qubits and determine if they possess an astrophysical origin. Constructed with three scintillator-attached PMTs read out with NIM modules in a triply-coincident logic scheme, we measure a surface-level muon luminosity of 9.7425 muons per second---consistent with an average surface-level cosmic-ray flux of approximately one muon per square centimeter per minute. Integrating the NIM modules with an MCC 128 DAQ HAT and Raspberry Pi, a Python script records exactly when a muon struck the detector and writes a timestamp to a log file for follow-up cross referencing. This experiment will broadly contribute to further studies aimed at understanding the source and mitigation of information loss in qubits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time Ethernet Interface for NSTX-U’s Thomson Scattering Diagnostic (2023)

Here, the multipoint Thomson scattering (MPTS) diagnostic system at the National Spherical Torus Experiment Upgrade (NSTX-U) facility is undergoing an upgrade to operate in real-time and interface with the plasma control system (PCS) for NSTX-U. Previous prototyping efforts have shown that spectral analysis and rapid calculations of electron temperature and density are possible on a real-time Linux machine when using up to a 100-Hz laser pulse repetition rate. A remaining challenge was transferring the real-time data to NSTX-U’s PCS, which utilizes the front panel data port (FPDP) protocol. The original proposed method was to convert the real-time data into analog values, but a new solution was developed to keep the output format digital by using an Ethernet controller with a field-programmable gate array (FPGA). This article focuses on a new input module that has been developed to accept incoming user datagram protocol (UDP) packets sent over Ethernet, convert into FPDP format, and integrate into the existing data stream under NSTX-U’s real-time framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Throughput Optical Mapping for Accelerated Stress Testing of PV Module Materials

The study will provide guidance towards the design and application of larger and/or outdoor-use intended instruments. Measurement capability will be benchmarked against existing specimens, examined in a round-robin study using conventional spectrophotometer instruments. Data acquisition and storage will be integrated into the DuraMAT DataHub network along with data visualization tool, facilitating sharing of information.

14 SOLAR ENERGY↗

A 10-Gb/s Driver/Receiver ASIC and Optical Modules for Particle Physics Experiments

We present the design and test results of a Drivers and Limiting AmplifierS ASIC operating at 10 Gbps (DLAS10) and three Miniature Optical Transmitter/Receiver/Transceiver modules (MTx+, MRx+, and MTRx+) based on DLAS10. DLAS10 can drive two Transmitter Optical Sub-Assemblies (TOSAs) of Vertical Cavity Surface Emitting Lasers (VCSELs), receive the signals from two Receiver Optical Sub-Assemblies (ROSAs) that have no embedded limiting amplifiers, or drive a VCSEL TOSA and receive the signal from a ROSA, respectively. Each channel of DLAS10 consists of an input Continuous Time Linear Equalizer (CTLE), a four-stage limiting amplifier (LA), and an output driver. The LA amplifies the signals of variable levels to a stable swing. The output driver drives VCSELs or impedance-controlled traces. DLAS10 is fabricated in a 65 nm CMOS technology. The die is 1 mm x 1 mm. DLAS10 is packaged in a 4 mm x 4 mm 24-pin quad-flat no-leads (QFN) package. DLAS10 has been tested in MTx+, MRx+, and MTRx+ modules. Both measured optical and electrical eye diagrams pass the 10 Gbps eye mask test. Furthermore, the input electrical sensitivity is 40 mVp-p, while the input optical sensitivity is -12 dBm. The total jitter of MRx+ is 29 ps (P-P) with a random jitter of 1.6 ps (RMS) and a deterministic jitter of 9.9 ps. Each MTx+/MTRx+ module consumes 82 mW/ch and 174 mW/ch, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Software Architecture and Hardware Organization in Mu2e Solenoid Field Mapping System

Herein, the Mu2e field mapping system is designed to produce high accuracy field maps of the detector solenoid used in the experiment. The data acquisition system is mobile and uses a self-propelled mapper with rotating arms equipped with 3D Hall probes. The measurements require not only accurate magnetic field readouts, but also accurate locations of all Hall probes while measuring data. The latter is accomplished by using the laser tracker to measure positions of several retroreflectors on the field mapper during data acquisition. The measurement process requires scanning the whole space inside the large solenoid and takes many hours to complete, which necessitates its full automation. The automation software includes control of the mapper, readout of Hall and NMR probes and control of a laser tracker, including prediction of retroreflector positions and execution of quality control checks. The software architecture and data acquisition hardware of the field mapping system are described, with special attention given to control of the laser tracker and its integration with the rest of the system.

3d hall probes↗

New Pulsed Neutron Die-Away Experiments in Light Water

Thermal neutron scattering laws are important data for many nuclear science and engineering applications, especially criticality safety. Recently, pulsed-neutron die-away experiments have been proposed and used as an experiment to validate thermal neutron scattering laws. These experiments involve irradiating a target moderating material with pulses of neutrons from a neutron generator. The physics of thermal scattering greatly affect how the neutron population in the target exponentially decays via absorption and leakage. Herein, we present experimental results from a new pulsed-neutron die-away experiment of light water that was performed at Lawrence Livermore National Laboratory. The experiments were done with cylindrical targets of varying dimensions to modulate the experiment’s sensitivity to thermal scattering and to absorption. We compare the measured integral parameter of the experiment to simulations with MCNP6.2 ® and to past experiments in literature. The integral parameters that were more sensitive to TSLs showed a larger bias. This validation study is known to have errors because the model of the experiment lacks key features about the detectors and neutron generator. These features will be included in the final benchmark evaluation of the experiment which will be submitted to the International Criticality Safety Benchmark Evaluation Project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic electronics for noble liquid neutrino detectors

In this paper we present the general features of cryogenic (or “cold”) electronics for noble liquid time projection chambers, with design principles and details for neutrino physics, a brief history of the technology and details of recent research and development that is driving the design of the detectors under construction. Finally, some comments on future R&D envisioned and the impact of this work on other fields is described. “Cold” in the context of this work applies to CMOS devices operated at 77 K and above, at liquids temperatures of LAr (89 K), LKr (125 K) and LXe (165 K), with most of the tests performed in, or at LN 2 (77 K). Additionally, the paper is concentrated on the design of cold electronics for large liquid argon TPCs, those that have been successfully operated, MicroBooNE and ProtoDUNE, and those designed or under construction, such as SBND and DUNE first and second 10 kton modules. The high performance achieved with MicroBooNE and ProtoDUNE – a high signal-to-noise ratio combined with high stability of response – is mainly due to the integral approach to design and construction of sensing electrodes with cold readout electronics in a modular approach with the cryostat signal feed-throughs incorporating warm interface electronics into a Faraday cage with the cryostat. The integral concept is described in some detail in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Application Specific Integrated Circuit Design

Single radiation effects can be transient and static. The charge collected from radiation has a prompt (drift) and a slow (diffusion) component. This current spike causes disparate results: SEU, SET, SEB, MBU, and more. A system level SEE mitigation technique, used to overcome, is the triple module redundancy (TMR). TMR for system Verilog (TMR4SV), written in Python, is the first step towards design IP triplication. It allows various triplication methods for flip flops, clocks, and logic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RD53A: A large-scale prototype chip for the phase II upgrade in the serially powered HL-LHC pixel detectors

The phase II upgrade of the HL-LHC experiments within the LHC intends to deepen the studies of the Higgs boson and to allow the discovery of further particles by adding an integrated luminosity of about 4000 fb -1 over 10 years of operation. This upgrade would overwhelm the installed pixel detector readout chips with higher hit rates and radiation levels than ever before. To match these extreme requirements the RD53 collaboration, a joint effort between ATLAS and CMS, developed RD53A, a new generation pixel detector readout chip prototype manufactured in a 65 nm CMOS technology. It is half the size of the final pixel chips and designed to meet requirements in the face of 3 GHz/cm 2 hit rate after irradiation to 500 Mrad. The detector is able to use 50×50 μm 2 or 25×100 μm 2 pixels with high readout speed of up to 4 links per chip with 1.28 Gbit/s each. Shunt–LDO regulators integrated on the bottom of the chip provide the required voltages to the two power domains, analog and digital. These regulators enable serial powering of the pixel modules, which is the only feasible, radiation hard scheme to ensure acceptable power cable losses and to stay within the material budget for the future pixel detectors. Finally, an overview of the status and challenges of serial powering and the Shunt–LDO regulator development will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatile Link+ Transceiver Production Readiness

The Versatile Link + project is about to enter its production phase, ready for the Phase 2 HL-LHC detector upgrades. We present the status of the front-end part of the Versatile Link$^+$ project: the Versatile Link$^+$ Transceiver, which provides a low-mass, radiation tolerant, optical transmit- and receive module for tight integration in the upgrading HL-LHC detectors. We describe the development and thorough testing carried out with the transceiver prototypes and their sub-components and the design decisions that have led to the final production-ready prototype. The planned production schedule is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Normality of I-V Measurements Using ML

There is an increased interest in instrument-computing ecosystems (ICEs) that support science workflows empowered by AI-automated experiments and computations in diverse areas. In particular, electrochemistry ICEs are promising for accelerating the design and discovery of electrochemical systems for energy storage and conversion, by automating significant parts of workflows that combine synthesis and characterization experiments with computations. They require the integration of flow controllers, solvent containers, pumps, fraction collectors, and potentiostats, all connected to an electrochemical cell, as illustrated in Fig. 1. These are specialized instruments with custom software that is not originally designed for network integration. We developed network and software solutions for electrochemical workflows that adapt system and instrument settings in real-time for multiple rounds of experiments. In particular, we developed Python wrappers for Application Programming Interfaces (APIs) of instrument commands and Pyro client-server modules that enable them to be executed from remote computers. The entire workflow is orchestrated by a Jupyter notebook running on a remote computer.

Al Najjar, Anees↗

Fast response High Altitude Laser Optical Sensor (HALOS) for atmospheric water and temperature measurements

Advanced instrumentation and sensing methods are the key factor in the determination of many climate science research problems. In this Phase I STTR a laser-based diagnostic system for atmospheric temperature and water concentrations measurements was developed, this system, HALOS – High Altitude Laser Optical Sensor, employs a mid-infrared (MIR) quantum cascade laser (QCL) of the distributed feedback variety (DFB) powered by a 100 kHz rep rate ramp modulated current profile which enables spectral profiling. Measurements made during Phase I showed that HALOS can surpass the available hygrometers refresh rates while offering superior accuracy (<4%) from the low Frost Point (Tfrost) of -110°C to dew points (Tdew) at 35°C while being able to encompass sub ppm concentration at altitude and supersaturated conditions at ground level. Readings from HALOS include temperature sensitivity on the order of 0.2°C and absolute humidity sensitivity (AH) on the order of 0.010 μmol/m 3 (0.18 mg/m 3 ) at a data output rate exceeding 1 kHz. HALOS can be easily integrable in existing Department of Energy (DOE) or National Oceanic and Atmospheric Administration (NOAA) conventional or remote operated aircraft having either a fixed or rotary wing.

54 ENVIRONMENTAL SCIENCES↗

High spatial resolution direct conversion amorphous selenium X-ray detectors with monolithically integrated CMOS readout

Recent progress in the field of micron-scale spatial resolution direct conversion X-ray detectors for high-energy synchrotron light sources serve applications ranging from nondestructive and noninvasive microscopy techniques which provide insight into the structure and morphology of crystals, to medical diagnostic measurement devices. Amorphous selenium ( a -Se) as a wide-bandgap thermally evaporated photoconductor exhibits ultra-low thermal generation rates for dark carriers and has been extensively used in X-ray medical imaging. Being an amorphous material, it can further be deposited over large areas at room temperatures and at substantially lower costs as compared to crystalline semiconductors. Here, to address the demands for a high-energy and high spatial resolution X-ray detector for synchrotron light source applications, we have thermally evaporated a -Se on a Mixed-Mode Pixel Array Detector (MM-PAD) Application Specific Integrated Circuit (ASIC). The ASIC format consists of 128 × 128 square pixels each 150 μm on a side. A 200 μm a -Se layer was directly deposited on the ASIC followed by a metal top electrode. The completed detector assembly was tested with 45 kV Ag and 23 kV Cu X-ray tube sources. The detector fabrication, performances, Modulation Transfer Function (MTF) measurements, and simulations are reported.

36 MATERIALS SCIENCE↗

Optics-on-a-chip for ultrafast manipulation of 350-MHz hard x-ray pulses

Microelectromechanical systems (MEMS) are miniature devices integrated into a vast range of industrial and consumer applications. Optical MEMS are developed for dynamic spatiotemporal control in lightwave manipulation and communication as modulators, switches, multiplexers, spectrometer, etc. However, they have not been shown to function similarly in sub-nm wavelength regimes, namely, with hard x-rays, as high-brilliance pulsed x-rays have proven powerful for addressing challenges in time-domain science, from energy conversion to neurobiological control. While desirable temporal properties of x-ray pulses can be enhanced by optics, conventional x-ray optics are inherently massive in size, hence, never dynamic. We demonstrate highly ultrafast x-ray optics-on-a-chip based on MEMS capable of modulating hard x-ray pulses exceeding 350 MHz, 10 3 × higher than any other mechanical modulator, with a pulse purity >10 6 without compromising the spectral brilliance. Moreover, the timing characteristics of the devices can be tuned on-the-fly to deliver optimal pulse properties to create a host of dynamic x-ray instruments and applications, impossible with traditional optics of 10 9 × bulkier and more massive. The advent of the ultrafast optics-on-a-chip heralds a new paradigm of x-ray photonics, time-domain science, and accelerator diagnostics, especially at not only the future-generation light sources that offer coherent and high-frequency pulses but also lab-based facilities that normally do not offer timing structures.

42 ENGINEERING↗

Topography restoration in white-light interferometry using an instrument transfer function evaluated with binary pseudo-random arrays

Accurate knowledge of the instrument transfer function (ITF) is vital for topography measurements using white-light interferometry (WLI). To this end, we derive a complete set of analytical expressions for the power spectral density (PSD) of a discretely sampled binary pseudo-random array (BPRA) as a theoretical benchmark. We then determine the ITF by comparing this theoretical PSD with the measured PSD of the BPRA. For the Zygo ZeGage Pro HR with a objective, the determined ITF closely matches the nominal modulation transfer function (MTF). Accordingly, we integrate the nominal MTF into Fourier-domain restoration filters and apply them to practical WLI topography data, yielding restored topographies that show improved agreement with atomic force microscopy measurements. Overall, our integrated BPRA-based ITF measurement and filtering methodology offers a robust yet practical means of characterizing WLI performance and enhancing the accuracy of surface measurements.

Hirose, Shigenobu [Japan Agency for Marine Earth S↗