Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integrated energy efficiency ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Chapter 4: Small Commercial and Residential Unitary and Split System HVAC Heating and Cooling Equipment-Efficiency Upgrade Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

The specific measure described here involves improving the overall efficiency in air-conditioning systems as a whole (compressor, evaporator, condenser, and supply fan). The efficiency rating is expressed as the energy efficiency ratio (EER), seasonal energy efficiency ratio (SEER), and integrated energy efficiency ratio (IEER). The higher the EER, SEER or IEER, the more efficient the unit is.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ANSI/ASHRAE/IES Standard 90.1-2013 Preliminary Determination: Qualitative Analysis

This report provides a preliminary qualitative analysis of all addenda to ANSI/ASHRAE/IES Standard 90.1-2010 (referred to as Standard 90.1-2010 or 2010 edition) that were included in ANSI/ASHRAE/IES Standard 90.1-2013 (referred to as Standard 90.1-2013 or 2013 edition). All addenda in creating Standard 90.1-2013 were evaluated for their projected impact on energy efficiency. Each addendum was characterized as having a positive, neutral, or negative impact on overall building energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A high efficiency rooftop air conditioning system using multi-speed compressors

This study delineates a meticulous exploration of technologies to enhance the energy efficiency of rooftop air conditioning units, employing the DOE/ORNL heat pump design model for comprehensive engineering design and optimization. A baseline rooftop air conditioning unit, featuring a 13 ton (45.7 kW) cooling capacity and a 17.9 integrated energy efficiency ratio, served as the point of departure for substantive efficiency enhancements. Key modifications included the consolidation of two refrigerant circuits into one, integrating three parallel 2-stage (dual-speed) compressors, fan replacements with high-efficiency substitutes. Notably, a lower global warming potential refrigerant, R452B, was evaluated as a substitute for R-410A, demonstrating better performance in the lab prototype. Further, the achieved measured integrated energy efficiency ratio of 21.4 in the lab prototype surpassed the baseline integrated energy efficiency ratio. Comparative evaluations between R410A and R452B indicated heightened efficiency with the latter, showcasing a lab-demonstrated integrated energy efficiency ratio of 22.4 at the rated capacity of 13.8 ton (48.5 kW) and 23.9 integrated energy efficiency ratio at the rated capacity of 10 ton (35.2 kW). This research underscores the successful development of a rigorous, energy efficient rooftop air conditioning unit prototype with noteworthy environmental and economic implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and evaluation of a multi-functional heat pump with embedded thermal storage

We developed and tested a novel multi-functional packaged vertical heat pump designed for multi-family buildings, capable of providing space cooling, space heating, water heating, and energy storage integration. The system employs a 3-speed scroll compressor and supports energy-efficient cooling and heating across different ambient conditions, while utilizing both indoor and outdoor air sources for water heating. Key performance metrics include an integrated energy efficiency ratio of 18.0 for cooling, a heating seasonal performance factor of 10.0, and a coefficient of performance (COP) of 2.1 for heating in cold climates down to −15 ˚C. Additionally, the system delivers an annual water heating COP greater than 4.0, with outstanding performance in combined space cooling and water heating modes, achieving a total COP of 8.8 by recovering condenser waste heat. The heat pump also demonstrated thermal energy storage capabilities, integrating with phase change material systems to store heating and cooling energy. Furthermore, this versatile system offers a promising solution for improving energy efficiency and sustainability in multi-family buildings, providing high-performance heating, cooling, and water heating across a range of climates.

COP↗

RTU Comparison Calculator Enhancement Plan

Over the past two years, Department of Energy’s Building Technologies Office (BTO) has been investigating ways to increase the operating efficiency of the packaged rooftop units (RTUs) in the field. First, by issuing a challenge to the RTU manufactures to increase the integrated energy efficiency ratio (IEER) by 60% over the existing ASHRAE 90.1-2010 standard. Second, by evaluating the performance of an advanced RTU controller that reduces the energy consumption by over 40%. BTO has previously also funded development of a RTU comparison calculator (RTUCC). RTUCC is a web-based tool that provides the user a way to compare energy and cost savings for two units with different efficiencies. However, the RTUCC currently cannot compare savings associated with either the RTU Challenge unit or the advanced RTU controls retrofit. Therefore, BTO has asked PNNL to enhance the tool so building owners can compare energy and savings associated with this new class of products. This document provides the details of the enhancements that are required to support estimating energy savings from use of RTU challenge units or advanced controls on existing RTUs.

Miller, James D.↗

RTU Comparison Calculator Enhancement Plan

Over the past two years, Department of Energy’s Building Technologies Office (BTO) has been investigating ways to increase the operating efficiency of the packaged rooftop units (RTUs) in the field. First, by issuing a challenge to the RTU manufactures to increase the integrated energy efficiency ratio (IEER) by 60% over the existing ASHRAE 90.1-2010 standard. Second, by evaluating the performance of an advanced RTU controller that reduces the energy consumption by over 40%. BTO has previously also funded development of a RTU comparison calculator (RTUCC). RTUCC is a web-based tool that provides the user a way to compare energy and cost savings for two units with different efficiencies. However, the RTUCC currently cannot compare savings associated with either the RTU Challenge unit or the advanced RTU controls retrofit. Therefore, BTO has asked PNNL to enhance the tool so building owners can compare energy and savings associated with this new class of products. This document provides the details of the enhancements that are required to support estimating energy savings from use of RTU challenge units or advanced controls on existing RTUs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DEVELOPMENT OF 20 IEER ROOFTOP UNITS A SIMULATION STUDY

Based on detailed steady-state system and component modeling, we developed a rooftop unit system design, which is able to achieve IEER (Integrated Energy Efficiency Ratio) higher than 20. We modeled fin-&-tube and micro-channel heat exchangers using segment-to-segment approach, and use ARI 10-coefficient compressor map to simulate compressor performance. The system modeling is based on a component-based modeling approach, which facilitates flexible simulation of complicated system configurations. Starting with a baseline system having IEER of 16.6, we extensively investigated numerous technical options, i.e. varying compressor sizes, heat exchanger fin densities, fin-&-tube or micro-channel heat exchanger, suction line heat exchanger, desiccant wheel, tandem compressor, variable-speed compressor, and condenser evaporative pre-cooling; and developed an innovative system configuration combining a tandem compression system with a variable-speed compression system. The combined system can achieve high IEER as well as process the outdoor ventilation air over an extensive range. We successfully evaluated the design concept for a 20-ton unit as well as a 10-ton unit. All the selected components are readily accessible on the market, and we validated the performance predictions against existing RTU products at the rating condition. This paper illustrates a potentially cost-effective high IEER RTU design.

Modeling↗

Development of 20 IEER Rooftop Units System Modeling and Building Energy Simulations

Based on detailed steady-state system and component modeling, we developed a rooftop unit system design, which is able to achieve IEER (Integrated Energy Efficiency Ratio) higher than 20. We modeled fin-&-tube and micro-channel heat exchangers using segment-to-segment approach, and use AHRI 10-coefficient compressor map to simulate compressor performance. The system modeling is based on a component-based modeling approach, which facilitates flexible simulation of complicated system configurations. Starting with a baseline system having IEER of 16.6, we extensively investigated numerous technical options, i.e. varying compressor sizes, heat exchanger fin densities, fin-&-tube or micro-channel heat exchanger, suction line heat exchanger, desiccant wheel, tandem compressor, variable-speed compressor, and condenser evaporative pre-cooling; and developed an innovative system configuration combining a tandem compression system with a variable-speed compression system. The combined system can achieve high IEER as well as process the outdoor ventilation air over an extensive range. We successfully evaluated the design concept for a 20-ton (70.4 kW) unit as well as a 10-ton (35.2 kW) unit. All the selected components are readily accessible on the market, and we validated the performance predictions against existing Rooftop Unit (RTU) products at the rating condition. This paper illustrates a potentially cost-effective high IEER RTU design. In addtion, we conducted extensive building energy simulations using EnergyPlus to predict seasonal energy saving potentials and peak power reductions using the High IEER RTU in sixteen US cities, in comparison to a RTU with a minimum efficiency.

Modeling↗

ANSI/ASHRAE/IES Standard 90.1-2013 Determination of Energy Savings: Quantitative Analysis

This report provides the quantitative analysis to assess whether buildings constructed according to the requirements of ANSI/ASHRAE/IES Standard 90.1-2013 would result in improved energy efficiency in commercial buildings. The analysis considered each of the addenda to Standard 90.1-2010 that were included in Standard 90.1-2013.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Analysis: ANSI/ASHRAE/IES Standard 90.1-2016

To meet statutory requirements, DOE conducted an analysis to quantify the expected energy savings associated with Standard 90.1-2016. This report documents the methodology used to conduct the analysis. Based on the analysis, DOE has determined that the 2016 edition of the ANSI/ASHRAE/IES Standard 90.1 would improve overall energy efficiency in buildings subject to the code compared to the 2013 edition of Standard 90.1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A compact design for an electric driven hydraulic gear machine capable of multiple quadrant operation

This paper presents an innovative design of an integrated electro-hydraulic (EH) flow generation unit able to operate in multiple quadrants. The proposed unit is composed of a hydraulic machine which can operate in either pumping or motoring mode, and an electric machine, which can operate as electric motor or generator. The adopted morphological integration of the two unit fulfills the goals of maximizing compactness, power to weight ratio, energy efficiency and quietness. Furthermore, the design results from a numerical optimization procedure that includes detailed simulation of both the electric machine and the hydraulic machine, using simulation tools previously developed by the authors, but combined for the first time in this work. After describing the optimization procedure, the paper focuses on the design integration aspects of the novel unit. A 9 kW prototype of the integrated unit was also fabricated and tested to verify its performance. Tests results show a measured overall energy efficiency up to 69%, demonstrating the potentials of the proposed concept, despite some limitations present in the first prototypes which could be addressed in future design refinements.

42 ENGINEERING↗

Additive Manufacturing of Thermal Energy Storage Composites with Microencapsulated Phase Change Materials Supported in a Multipolymer Matrix

Additive manufacturing (AM) techniques to directly integrate phase change materials (PCMs) are of interest for efficient thermal energy storage (TES) architectures. Complex, high surface-to-volume ratio composites embedded with PCM can improve thermal management with reduced material waste for customizable device fabrication. Reducing feature sizes of TES-integrated heat exchangers using AM can increase heat transfer without thermal conductivity enhancement. Here, composite AM materials containing 60 wt% microencapsulated phase change materials (MEPCM) are fabricated using off-the-shelf printers at common speeds and resolutions. High MEPCM loading in filaments is achieved with powder extrusion using two polymers, thermoplastic-polyurethane (TPU) and polycaprolactone (PCL), that mediate flexibility and rigidity for effective extrusion and printing without filament fracture or buckling. Furthermore, with PCL and TPU at 20 wt% each and 60 wt% MEPCM (P 20 T 20 M 60 ), smooth, form-stable filaments are consistently printed. Powder-based extrusion displays negligible damaging effects on the MEPCM. Printed P 20 T 20 M 60 demonstrates 105 J/g of energy storage with no degradation through 250 thermal cycles, within 5% of the theoretical storage enthalpy. Combining PCL/TPU shows good interfacial adhesion between print layers and produces high surface area objects, like 15% gyroids, and dense, 100% infilled pucks. Prints are also scalable to a 900 cm 3 honeycomb heat exchanger with an estimated 9 Wh energy storage.

25 ENERGY STORAGE↗

Proposal of a novel multifunctional energy system for cogeneration of coke, hydrogen, and power - article no. 052001

This paper proposes a novel multifunctional energy system (MES), which cogenerates coke, hydrogen, and power, through the use of coal and coke oven gas (COG). In this system, a new type of coke oven, firing coal instead of COG as heating resource for coking, is adopted. The COG rich in H{sub 2} is sent to a pressure swing adsorption (PSA) unit to separate about 80% of hydrogen first, and then the PSA purge gas is fed to a combined cycle as fuel. The new system combines the chemical processes and power generation system, along with the integration of chemical conversion and thermal energy utilization. In this manner, both the chemical energy of fuel and thermal energy can be used more effectively. With the same inputs of fuel and the same output of coking heat, the new system can produce about 65% more hydrogen than that of individual systems. As a result, the thermal efficiency of the new system is about 70%, and the exergy efficiency is about 66%. Compared with individual systems, the primary energy saving ratio can reach as high as 12.5%. Based on the graphical exergy analyses, we disclose that the integration of synthetic utilization of COG and coal plays a significant role in decreasing the exergy destruction of the MES system. The promising results obtained may lead to a clean coal technology that will utilize COG and coal more efficiently and economically.

08 HYDROGEN↗

Chance-constrained economic dispatch with renewable energy and storage

Increased penetration of renewables, along with uncertainties associated with them, have transformed how power systems are operated. High levels of uncertainty means that it is not longer possible to guarantee operational feasibility with certainty, instead constraints are required to be satisfied with high probability. We present a chance-constrained economic dispatch model that efficiently integrates energy storage and high renewable penetration to satisfy renewable portfolio requirements. Specifically, it is required that wind energy contributes at least a prespecified ratio of the total demand and that the scheduled wind energy is dispatchable with high probability. We develop an approximated partial sample average approximation (PSAA) framework to enable efficient solution of large-scale chanceconstrained economic dispatch problems. Computational experiments on the IEEE-24 bus system show that the proposed PSAA approach is more accurate, closer to the prescribed tolerance, and about 100 times faster than sample average approximation. Improved efficiency of our PSAA approach enables solution of WECC-240 system in minutes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Theoretical foundations of waste factor and waste figure with applications to fixed wireless access and relay systems

The growing energy demands of next-generation wireless systems call for unified, system-level metrics to evaluate and optimize energy efficiency. This paper advances the concept of the Waste Factor (W), or Waste Figure (WF) in decibel scale, as a general framework for modeling power loss across cascaded communication components. By integrating W into the Consumption Factor (CF)–the ratio of data rate to consumed power–we reveal how component inefficiencies influence the minimum achievable energy per bit. Closed-form expressions are derived for energy-per-bit consumption in both direct and relay-assisted links, along with a decision rule for selecting the more energy-efficient path. While not explicitly modeled, Reflective Intelligent Surfaces (RIS) are shown to fit naturally within this framework. The analysis is further applied to a Fixed Wireless Access (FWA) scenario, where asymmetries in traffic direction and hardware inefficiencies are jointly considered, demonstrating the utility of the Waste Factor in guiding energy-aware system design.

Sevim, Nurullah [Texas A&M University, College Sta↗

Directing CO 2 electroreduction pathways for selective C 2 product formation using single-site doped copper catalysts

Manipulating the selectivity-determining step in post-C–C coupling is crucial for enhancing C 2 product specificity during electrocatalytic CO 2 reduction, complementing efforts to boost rate-determining step kinetics. Here we highlight the role of single-site noble metal dopants on Cu surfaces in influencing C–O bond dissociation in an oxygen-bound selectivity-determining intermediate, steering post-C–C coupling toward ethylene versus ethanol. Integrating theoretical and experimental analyses, we demonstrate that the oxygen binding strength of the Cu surface controls the favorability of C–O bond scission, thus tuning the selectivity ratio of ethylene-to-ethanol. The Rh-doped Cu catalyst with optimal oxygen binding energy achieves a Faradaic efficiency toward ethylene of 61.2% and an ethylene-to-ethanol Faradaic efficiency ratio of 4.51 at –0.66 V versus RHE (reversible hydrogen electrode). Integrating control of both rate-determining and selectivity-determining steps further raises ethylene Faradaic efficiency to 68.8% at 1.47 A cm -2 in a tandem electrode. Our insights guide the rational design of Cu-based catalysts for selective CO 2 electroreduction to a single C 2 product.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of the concentration ratio on energetic and exergetic performance of concentrating solar collectors with integrated transparent insulation materials

The effect of the concentration ratio on the performance of parabolic trough and central receiver collectors with integrated Transparent Insulation Materials (TIMs) is analyzed in this work. A model based on optical, energy, and exergy analyses is developed to determine thermal and second law efficiencies of concentrated solar collectors as a function of the absorber temperature and concentration ratio. The results are compared with the respective traditional collector configurations without TIM. In general, high concentration ratios are fundamental to maintain high efficiencies. The incorporation of a TIM into concentrated solar collectors leads to higher thermal efficiencies at high operating temperatures even at low concentration ratios. An equivalent second law efficiency to that of the reference collector configuration can be achieved at lower concentration ratios by incorporating a TIM in parabolic trough or a TIM and a glass envelope in central receiver collectors. As a result, the idea of using a TIM deserves further exploration as it seems to be a promising alternative that contributes to a more efficient and cost-effective technology.

14 SOLAR ENERGY↗

ANSI/ASHRAE/IES Standard 90.1-2013 Determination of Energy Savings: Qualitative Analysis

This report provides the qualitative analysis of all addenda to ANSI/ASHRAE/IES1 Standard 90.1-2010 (referred to as Standard 90.1-2010 or 2010 edition) that were included in ANSI/ASHRAE/IES Standard 90.1-2013 (referred to as Standard 90.1-2013 or 2013 edition). All addenda in creating Standard 90.1-2013 were evaluated for their projected impact on energy efficiency. Each addendum was characterized as having a positive, neutral, or negative impact on overall building energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗