Search NASA⌕ Search

SEARCH · Search NASA

Results for “Interdigitated combs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Direct visualization of electromagnetic wave dynamics by laser-free ultrafast electron microscopy

Integrating femtosecond lasers with electron microscopies has enabled direct imaging of transient structures and morphologies of materials in real time and space. Here, we report the development of a laser-free ultrafast electron microscopy (UEM) offering the same capability but without requiring femtosecond lasers and intricate instrumental modifications. We create picosecond electron pulses for probing dynamic events by chopping a continuous beam with a radio frequency (RF)–driven pulser with the pulse repetition rate tunable from 100 MHz to 12 GHz. As a first application, we studied gigahertz electromagnetic wave propagation dynamics in an interdigitated comb structure. We reveal, on nanometer space and picosecond time scales, the transient oscillating electromagnetic field around the tines of the combs with time-resolved polarization, amplitude, and local field enhancement. This study demonstrates the feasibility of laser-free UEM in real-space visualization of dynamics for many research fields, especially the electrodynamics in devices associated with information processing technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stroboscopic ultrafast imaging using RF strip-lines in a commercial transmission electron microscope

The development of ultrafast electron microscopy (UEM), specifically stroboscopic imaging, has brought the study of structural dynamics to a new level by overcoming the spatial limitations of ultrafast spectroscopy and the temporal restrictions of traditional TEM simultaneously. Combining the concepts governing both techniques has enabled direct visualization of dynamics with spatiotemporal resolutions in the picosecond-nanometer regime. Here, in this study, we push the limits of imaging using a pulsed electron beam via RF induced transverse deflection based on the newly developed 200 keV frequency-tunable strip-line pulser. We demonstrate 0.2 nm spatial resolution at high magnifications and elucidation of Lorentz imaging using the phase-microscopy method. We also present beam coherence measurements and expand our study using the breathing modes of a silicon interdigitated comb under RF excitation which achieves improved temporal synchronization between the electron pulse-train and electric field. A new RF holder has also been developed with impedance matching to the RF signal to minimize transmission power loss to samples and its performance is compared with a conventional sample holder.

47 OTHER INSTRUMENTATION↗

Advanced Frost Sensor for HVAC Applications

Frost is a common problem in heating, ventilation, and air conditioning (HVAC) systems that can degrade their efficiencies, leading to excessive electricity consumption. Appropriate defrosting is therefore essential for heat pumps and refrigeration systems. However, these systems typically run the defrost cycle based on a predetermined time interval, a method that does not accurately identify the amount of frost and thus consume excessive electricity. To substantially improve defrosting initiation and termination, this paper describes development of a smart sensor based on a capacitive sensing technique that can quantify frost accumulation and difference between frost, ice, and water. The reported sensor adopts interdigitated comb electrodes and can be updated to a potential multifunctional sensor array for the enhancing identification of frost, ice, and water with the integrated measurement of surface temperature, frost capacitance, and resistance. The proposed frost sensor is potentially expected to have widespread applications in HVAC systems, including heat pumps, refrigerators, and commercial refrigeration systems.

Gao, Zhiming↗

Modulating surface acoustic wave generation through superconductivity

Surface acoustic waves (SAWs), with their five orders-of-magnitude slower propagation velocity, allow for considerably shorter wavelengths at the same frequency compared to electromagnetic waves. The short wavelengths allow for device miniaturization and on-chip integration. The generic design of these devices involves piezoelectric substrates with comb-like arrays of Al or Au electrodes known as interdigitated transducers (IDTs) deposited on the surface. However, Al and Au both have shortcomings at the cryogenic temperatures required for quantum applications, namely, the formation of two-level systems and the lack of superconductivity perpetuating Ohmic losses, respectively. In this work, SAWs are generated in the high-MHz to low-GHz range using niobium nitride (NbN) interdigitated transducers and Bragg reflectors. We demonstrate the fabrication of acoustic devices through photolithography and reactive ion etching. The sharp transition between superconducting and normal states and the corresponding change in SAW transmission allows for fine control of the “on” (superconducting) and “off” (normal) states of NbN, with a ΔT = 1 K separating the transmission minimum and maximum. We demonstrate a 16× difference in transmission between the “on” and “off” states of the device. The SAW transmission behavior mirrors the change in resistance of NbN at its T c . These findings open up new possibilities for the integration of NbN SAW resonators into existing quantum architectures based on NbN and a method for adjusting transmission properties independent of applied voltage.

36 MATERIALS SCIENCE↗

Enhanced Interfacial Bonding of Graft Copolymers

To understand how thermoplastic welding strength can be tuned through chemical modifications and macromolecular topology, we combined coarse-grained molecular dynamics (MD) simulations with experimental validation. Our simulations examined the diffusion dynamics of both linear and graft polymers across representative interfaces, revealing that diffusion-controlled interdigitation follows a power law, with the exponent decreasing from 0.34 to 0.11 as grafting density increases from 7.5 to 196% (with side chains grafted to both sides of a monomer unit). The addition of side chains enhances welding efficiency, as dense bottlebrush polymers with high grafting density reach maximum rupture strength faster than linear polymers. However, their saturated rupture strength is lower. This observation is subsequently corroborated by experimental lap-shear tests comparing linear polyethylene with octene grafted polyethylene elastomers. Our MD simulations show that unlike linear polymers, where backbone entanglements dominate, the grafted side chains introduce mechanisms in addition to entanglement dilution. The rapid interdigitation of side chains creates a dense mesh of entropic van der Waals contacts, which can also enhance the film welding. Furthermore, our MD simulations reveal a brittle rupture behavior in linear and comb-like (mildly grafted) polymers, while bottlebrush (densely grafted) polymers display elastomeric behavior with a pronounced stress plateau prior to fracture. Our simulations deconvolute the influence of polymer topology on deformation behavior. The rate of polymer deformation becomes lower than the applied strain rate prior to rupture, and the onset of this deviation is progressively delayed from linear to bottlebrush polymers. This trend highlights the critical role of molecular architecture in governing the mechanical response. In conclusion, these results provide deeper insight into the underlying welding mechanisms of topological polymers and present a potential approach for mitigating the interface anisotropy that is inherent in advanced manufacturing techniques such as fused filament fabrication.

graft copolymers↗