Search NASA⌕ Search

SEARCH · Search NASA

Results for “Interferometry Low Frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of Optical Fiber-Based Sensors for Nuclear Microreactor Structural Health Monitoring

This report provides an experimental assessment of two different optical fiber–based acoustic sensors that are being investigated for application in nuclear microreactors to enhance structural health monitoring capabilities. Optical fibers are resilient in high-temperature and high-radiation environments, have a small sensor footprint, are immune to electromagnetic interference, and are capable of spatially distributed sensing. The two sensors investigated here are (1) Fabry–Pérot Cavities (FPCs) between two copper-coated fibers, embedded in nickel capillary tubes and (2) type-I fiber Bragg grating (FBG) arrays contained within metal capillary tubes. These sensors can be interrogated using low-coherence interferometry or swept wavelength interferometry, respectively, to measure the resonant frequencies of the components or systems to which these sensors are bonded. The FPC developed herein has been subjected to temperatures up to nearly 800°C while tack-welded to a tubular test specimen. Even at the highest temperatures, the measured resonant frequencies compared well with those obtained using an accelerometer that was bonded to an unheated portion of the specimen. The FBG array was tested in multiple bonding configurations to a tubular test specimen, all at room temperature, with the understanding that high temperature (i.e., type II) FBGs could be used to obtain similar data at high temperatures; the FBG array data were validated with noncontact laser vibrometry, which is being used at Los Alamos National Laboratory to relate acoustic signatures to component stresses and/or structural defects. The goal of this work is to identify the most promising techniques that are also compatible with operation in a microreactor environment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multifrequency Analysis of Favored Models for the Messier 87* Accretion Flow

Abstract The polarized images of the supermassive black hole Messier 87* (M87*) produced by the Event Horizon Telescope (EHT) provide a direct view of the near-horizon emission from a black hole accretion and jet system. The EHT theoretical analysis of the polarized M87* images compared thousands of snapshots from numerical models with a variety of spins, magnetization states, viewing inclinations, and electron energy distributions, and found a small subset consistent with the observed image. In this article, we examine two models favored by EHT analyses: a magnetically arrested disk with moderate retrograde spin and a magnetically arrested disk with high prograde spin. Both have electron distribution functions that lead to strong depolarization by cold electrons. We ray trace five snapshots from each model at 22, 43, 86, 230, 345, and 690 GHz to forecast future very long baseline interferometry (VLBI) observations and examine limitations in numerical models. We find that even at low frequencies where optical and Faraday rotation depths are large, approximately rotationally symmetric polarization persists, suggesting that shallow depths dominate the polarization signal. However, morphology and spectra suggest that the assumed thermal electron distribution is not adequate to describe emission from the jet. We find 86 GHz images show a ringlike shape determined by a combination of plasma and spacetime imprints, smaller in diameter than recent results from the Global mm-VLBI Array. We find that the photon ring becomes more apparent with increasing frequency, and is more apparent in the retrograde model, leading to large differences between models in asymmetry and polarization structure.

Astronomy & Astrophysics↗

Distributed Acoustic Sensing Based on Coherent Microwave Photonics Interferometry

A microwave photonics method has been developed for measuring distributed acoustic signals. This method uses microwave-modulated low coherence light as a probe to interrogate distributed in-fiber interferometers, which are used to measure acoustic-induced strain. By sweeping the microwave frequency at a constant rate, the acoustic signals are encoded into the complex microwave spectrum. The microwave spectrum is transformed into the joint time–frequency domain and further processed to obtain the distributed acoustic signals. The method is first evaluated using an intrinsic Fabry Perot interferometer (IFPI). Acoustic signals of frequency up to 15.6 kHz were detected. The method was further demonstrated using an array of in-fiber weak reflectors and an external Michelson interferometer. Two piezoceramic cylinders (PCCs) driven at frequencies of 1700 Hz and 3430 Hz were used as acoustic sources. The experiment results show that the sensing system can locate multiple acoustic sources. The system resolves 20 nε when the spatial resolution is 5 cm. The recovered acoustic signals match the excitation signals in frequency, amplitude, and phase, indicating an excellent potential for distributed acoustic sensing (DAS).

47 OTHER INSTRUMENTATION↗

Interplay between beam-driven chirping modes and plasma confinement transitions in spherical tokamak ST40

Experiments on the high field spherical tokamak ST40 have led to the recent observation of interplay between beam-driven modes of sweeping frequency (chirping modes) and transitions to the enhanced global confinement regime (H-mode) and back to the low confinement regime (L-mode). The H-modes of plasma confinement are identified from decreased intensity of D α signal and from clear distinctions in the edge gradients of the visible plasma boundary (observed as a sharp plasma edge in camera images). The beam-driven chirping modes, identified as ideal magnetohydrodynamics beta-induced Alfvén acoustic eigenmodes modes, are observed in Mirnov coil signals, interferometry, and soft x-ray diagnostics. A moderate amplitude ‘primer’ chirping mode usually precedes an H–L transition. This is followed by a ‘dominant’ chirping mode with higher amplitude during the L-mode. The L–H transition back to the improved confinement occurs on a longer time scale of tens of ms, consistent with the slowing down time scale of fast beam ions. A dramatic decrease in toroidal plasma rotation is systematically observed associated with chirping modes sweeping down to zero frequency. Resonance maps built for the beam-driven chirping modes with the ASCOT (accelerated simulation of charged particle orbits in torodoial devices) code show that the resonant beam ions have orbits near the trapped-passing boundary. The ASCOT modelling assesses how losses of the resonant fast ions caused by the chirping modes with high enough amplitude modify the torque, potentially affecting the plasma rotation.

magnetic confinement fusion↗

Fast quantum interferometry at the nanometer and attosecond scales with energy-entangled photons

In classical optical interferometry, loss and background complicate achieving fast nanometer-resolution measurements with illumination at low light levels. Conversely, quantum two-photon interference is unaffected by loss and background, but nanometer-scale resolution is physically difficult to realize. As a solution, we enhance two-photon interference with highly nondegenerate energy entanglement featuring photon frequencies separated by 177 THz. We observe measurement resolution at the nanometer (attosecond) scale with only O(10 4 ) photon pairs, despite the presence of background and loss. Our nondestructive thickness measurement of a metallic thin film agrees with atomic force microscopy, which often achieves better resolution via destructive means. With contactless, nondestructive measurements in seconds or faster, our instrument enables metrological studies in optically challenging contexts where background, loss, or photosensitivity are factors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polarimetry-Interferometry Diagnostic for Magnetic Field and Magnetic Fluctuation Measurements in High-Performance and Long-Pulse Tokamaks (Final Report)

In this grant, we executed a multi-year plan to develop an advanced Faraday-effect polarimeter-interferometer system to address both fluctuation and equilibrium diagnostic needs by providing a measurement of the plasma internal magnetic field fluctuations (including non-axisymmetric 3-D perturbations) and plasma vertical position. This diagnostic included both fast time response and low phase noise so that both the temporal dynamics of equilibrium quantities as well as high-frequency electromagnetic fluctuations could be measured simultaneously, adding new and unique measurement capabilities for the core of high-temperature plasmas. The combined polarimeter-interferometer diagnostic development was applied primarily to the tokamak magnetic configuration, focusing on high-performance regimes including H-mode, reversed shear advanced tokamak scenarios, and non-inductive current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collective plasma effects of electron–positron pairs in beam-driven QED cascades

Understanding the interplay of strong-field QED and collective plasma effects is important for explaining extreme astrophysical environments like magnetars. It has been shown that QED pair plasma can be produced and observed by passing a relativistic electron beam through an intense laser field. This work presents in detail multiple sets of 3D QED-particle-in-cell simulations to show the creation of pair plasma in the QED cascade. The beam driven method enables a high pair particle density and also a low particle Lorentz factor, which both play equal roles on exhibiting large collective plasma effects. Finite laser frequency upshift is observed with both ideal parameters (24 PW laser colliding with a 300 GeV electron beam) and with existing technologies (3 PW laser colliding with a 30 GeV electron beam).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stochastic frequency fluctuation super-resolution imaging

The inherent non-linearity of intensity correlation functions can be used to spatially distinguish identical emitters beyond the diffraction limit, as achieved, for example, in super-resolution optical fluctuation imaging (SOFI). Here, we propose a complementary concept based on spectral correlation functions, termed spectral fluctuation super-resolution (SFSR) imaging. Through theoretical and computational analysis, we show that spatially resolving time-frequency correlation functions in the image plane can improve the imaging resolution by a factor of $\sqrt2$ in most cases and up to twofold for strictly two emitters. This improvement is achieved by quantifying the degree of correlation in spectral fluctuations across the spatial domain. Experimentally, SFSR can be implemented using a combination of interferometry and photon-correlation measurements. The method works for non-blinking emitters and stochastic spectral fluctuations with arbitrary temporal statistics. This suggests its utility in super-resolution microscopy of quantum emitters at low temperatures, where spectral diffusion is often more pronounced than emitter blinking.

47 OTHER INSTRUMENTATION↗

Method for boosting dispersive spectrograph stability 1000× using interferometry with crossfaded pairs of delays

We demonstrate a key step along a technical route to achieving cm/s scale accuracy for astronomical spectrographs over long (multi-year) time scales, which is critical for the Doppler characterization of Earth sized exoplanets, and measurement of small cosmic redshift drift over many years. This same technique also enables searching exoplanet atmospheres for biosignificant molecules in direct planet imaging using, otherwise, insufficiently low resolution and drift prone dispersive (grating or prism) spectrographs. Using a method called crossfading for externally dispersed interferometers (EDIs) to get highly robust spectra, we recently demonstrated a factor of 1000 x reduction in the net shift of an EDI measured ThAr line to a deliberate simulated wavelength translation of the detector. This 1000 x gain in disperser stability can be combined with conventional stability gains afforded by fiber scramblers, vacuum tanks, and thermal control, to provide an additional 1 to 3 orders of magnitude reduction in the net point spread function shift drift. Crossfading combines high- and low-delay fringing signals that react oppositely in phase to cancel their net reaction to a detector wavelength drift. This can be implemented by an interferometer addition to a facility spectrograph.

79 ASTRONOMY AND ASTROPHYSICS↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interferometric bunch length measurements of 3 MeV picocoulomb electron beams

We report picosecond bunch length measurements using an interferometric method for a 3 MeV electron beam having bunch charge ranging from 1 to 14 pC. The method senses the single-cycle sub-terahertz (THz) pulse emitted by each electron bunch as coherent transition radiation which, in turn, is analyzed using a Michelson-type interferometer, forming an interferogram that is then processed to yield the nominal electron bunch length. This sub-THz coherent radiation intensity was measured using a quasi-optical detector (QOD) operated at room temperature. This experiment was quite challenging since the divergence angle of the sub-THz pulse emitted by the low-energy electron bunch exceeds ±10°, and its pulse energy at the entrance to the detector was as low as 100 pJ. When compared to a conventional helium-cooled silicon composite bolometer designed for frequencies above 0.5 THz, the QOD provided much better signal-to-noise ratio in the ~80 GHz frequency range, which was critical for the successful measurement of the bunch length.

36 MATERIALS SCIENCE↗

Design and performance of a multi-terahertz Fourier transform spectrometer for axion dark matter experiments

Dedicated spectrometers for terahertz radiation with [0.3, 30] THz frequencies using traditional optomechanical interferometry are substantially less common than their infrared and microwave counterparts. This paper presents the design and initial performance measurements of a tabletop Fourier transform spectrometer (FTS) for multi-terahertz radiation using infrared optics in a Michelson arrangement. This is coupled to a broadband pyroelectric photodetector designed for [0.1, 30] THz frequencies. We measure spectra of narrowband and broadband input radiation to characterize the performance of this instrument above 10 THz, where signal-to-noise is high. This paves the groundwork for planned upgrades to extend below 10 THz. We also briefly discuss potential astroparticle physics applications of such FTS instruments to broadband axion dark matter searches, whose signature comprises low-rate monochromatic photons with unknown frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The 140 GHz notch filter development for millimeter-wave diagnostics protection on the stellarator Wendelstein 7-X

The notch filter plays a crucial role as a protective component in microwave diagnostics, primarily by addressing issues related to catastrophic interference. Designed for millimeter-wave diagnostics on the stellarator Wendelstein 7-X (W7-X), a WR-6 waveguide-based notch filter has been successfully developed to effectively isolate leakage from auxiliary heating gyrotrons operating at 140 GHz. The filter incorporates cylindrical cavities resonating at 140 GHz for the TE11p mode, with coupling structures that are designed and optimized for high-efficiency coupling. This configuration simplifies fabrication, thereby ensuring high-yield production. Experimental fabrication and in-house characterization confirm the notch filter's exceptional performance, with over 60 dB rejection in the vicinity of 140 GHz and low insertion loss (< 2 dB) above and below the notch frequency across a broad frequency bandwidth (121–138 GHz, 142–163 GHz). Furthermore, the utilization of this high-frequency structure fabrication technology can be applied to millimeter-wave diagnostics on other machines. In addition to the design elements of the notch filter, this paper also provides a detailed discussion of the fabrication process and methodology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correlation polarimeter-interferometer in the DIII-D tokamak

A correlation polarimeter-interferometer system has been developed for the DIII-D tokamak to detect small amplitude magnetic and density fluctuations. Two collinear, frequency-offset (5–15 MHz), orthogonally polarized (right- and left-handed, circularly polarized) electromagnetic waves at 650 GHz probing the plasma are used to detect the Faraday effect. A third, linearly polarized, electromagnetic wave serves as the local-oscillator to provide a measure of the line-averaged density. Correlation polarimetric measurement is accomplished by correlating the Faraday effect measured along the same line of sight using two independent detectors, whereas simultaneous correlation interferometric measurement is realized by correlating the line-averaged density measured at two different intermediate frequencies. The noise floor of the correlation polarimeter-interferometer has been demonstrated to be more than one order of magnitude lower than that of a standard polarimeter-interferometer measurement. Line-averaged correlation polarimetric-interferometric measurements in DIII-D H-mode plasmas show broadband (up to 750 kHz) magnetic and density fluctuations with amplitudes as low as 0.03 $Gauss$/$\sqrt{kHz}$ and 4 × 10 13 m –3 /$\sqrt{kHz}$, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DOE SCGSR Final Report - Project Accomplishments and Additional Materials

The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Millimeter Light Curves of Sagittarius A* Observed during the 2017 Event Horizon Telescope Campaign

The Event Horizon Telescope (EHT) observed the compact radio source, Sagittarius A* (Sgr A*), in the Galactic Center on 2017 April 5–11 in the 1.3 mm wavelength band. At the same time, interferometric array data from the Atacama Large Millimeter/submillimeter Array and the Submillimeter Array were collected, providing Sgr A* light curves simultaneous with the EHT observations. These data sets, complementing the EHT very long baseline interferometry, are characterized by a cadence and signal-to-noise ratio previously unattainable for Sgr A* at millimeter wavelengths, and they allow for the investigation of source variability on timescales as short as a minute. While most of the light curves correspond to a low variability state of Sgr A*, the April 11 observations follow an X-ray flare and exhibit strongly enhanced variability. All of the light curves are consistent with a red-noise process, with a power spectral density (PSD) slope measured to be between −2 and −3 on timescales between 1 minute and several hours. Our results indicate a steepening of the PSD slope for timescales shorter than 0.3 hr. The spectral energy distribution is flat at 220 GHz, and there are no time lags between the 213 and 229 GHz frequency bands, suggesting low optical depth for the event horizon scale source. We characterize Sgr A*’s variability, highlighting the different behavior observed just after the X-ray flare, and use Gaussian process modeling to extract a decorrelation timescale and a PSD slope. We also investigate the systematic calibration uncertainties by analyzing data from independent data reduction pipelines.

79 ASTRONOMY AND ASTROPHYSICS↗

Free space Thomson scattering to study high energy density shocks

A free space collective Thomson scattering system has been developed to study pulsed power produced plasmas. While most Thomson scattering diagnostics on pulsed power machines use a bundle of fibers to couple scattered light from the plasma to the spectrometer, this system used free space coupling of the light, which enabled a spatially continuous image of the plasma. Initial experiments with this diagnostic were performed on an inverse wire array generated by a 200 kA, 1100 ns rise time pulse power generator. The capabilities of this diagnostic were demonstrated by using the low frequency ion acoustic wave feature of the Thomson scattering spectra to measure the plasma flow velocity. The diagnostic was demonstrated to measure velocities between 20 and 40 km/s with an error of 4.7 km/s when fitting with a 600 μm spatial resolution or 8.9 km/s when fitting with a 150 μm spatial resolution. In some experiments, the diagnostic observed a bow shock in the plasma flow as the scattering intensity increased and flow velocity decreased.

47 OTHER INSTRUMENTATION↗

Design of radial interferometer–polarimeter for internal magnetic and density fluctuation measurements at multiple space–time scales in the National Spherical Torus Experiment-Upgrade (NSTX-U)

A Faraday-effect radial interferometer–polarimeter is designed for the National Spherical Torus Experiment-Upgrade (NSTX-U) to measure multiscale magnetic and density fluctuations critical to understanding fusion plasma confinement and stability, including those originating from magnetohydrodynamic instabilities, energetic particle-driven modes, and turbulence. The diagnostic will utilize the three-wave technique with 5 MHz bandwidth to simultaneously measure line-integrated magnetic and density fluctuations up to the ion-cyclotron frequency. Probe beams will be launched radially from the low-field side at the NSTX-U midplane, where the measured Faraday fluctuations mainly correspond to radial magnetic fluctuations that directly link to magnetic transport. A correlation technique will be employed to reduce the measurement noise to below 0.01° enabling detection of small amplitude fluctuations. Two toroidally displaced chords with 7° separation will be installed to measure toroidal mode numbers up to n = 25 for mode identification. Finally, solid-state microwave sources operating at 321 μm (935 GHz) will be used to minimize the impact of the Cotton–Mouton effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗