Search NASASearch

SEARCH · Search NASA

Results for “Interferometry Narrow-angle astrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Indirect Planet Detection with Ground-Based Interferometry

Narrow-angle astrometry with long-baseline infrared interferometers can provide extremely high accuracies as required for indirect planet detection. Narrow-angle asrometric interferometry exploits the properties of atmospheric turbulence over fields smaller than the interferometer baseline divided by the atmospheric scale height.

Interferometry Narrow-angle astrometry

Potential of long-baseline infrared interferometry for narrow-angle astrometry

Narrow-angle astrometry has many astrophysical applications, from the measurement of parallaxes to the search for planets around nearby stars. Ground-based long-focus telescopes with photoelectric detectors have achieved accuracies of about 2-3 milliarcsec in 1 h. This accuracy is limited primarily by the atmosphere, and is consistent with models of atmospheric turbulence. However, applying these turbulence models to observations with long-baseline interferometers yields astrometric errors that are far smaller than can be achieved with long-focus telescopes. The predictions for the ultimate accuracy of ground-based narrow-angle astrometry using long-baseline IR (2.2 micron) stellar interferometers are very promising. With the excellent seeing at a high altitude site like Mauna Kea, the atmospheric limit for a 1 h astrometric measurement is expected to be of the order of 10 microarcsec for 1 h of integration. This two-order-of-magnitude improvement over conventional measurements is due to two effects. One is that a long-baseline IR interferometer can find useful reference stars very near an arbitrary target star, so that the atmospherically-induced motions of both stars are highly correlated. The second is that the baseline length can be much larger than the separation of the stellar beams in the turbulent atmosphere, resulting in a reduction in astrometric error with increasing baseline length.

Shao, M.

Indirect planet detection with ground-based long-baseline interferometry

Narrow-angle astrometry with long-baseline infrared interferometers can provide extremely high accuracies as required for indirect planet detection. Narrow-angle astrometric interferometry exploits the properties of atmospheric turbulence over fields smaller than the interferometer baseline divided by the atmospheric scale height. For such fields, accuracy is linear with star separation, and nearly inversely proportional to baseline length. To exploit these properties, the interferometer observes a relatively bright (less than 13 mag(sub K)) target in the near infrared at 2.2 micrometers, and uses phase referencing to find a reference star within the 2.2-micrometers isoplanatic patch. With this technique faint references can be found for most targets. With baselines greater than 100 m, which also minimize photon-noise errors, and with careful control of systematic errors by using laser metrology, accuracies of tens of microarcseconds/square root of (hour) should be possible.

Colavita, M. M.

Baseline Monitoring for Astrometry in Interferometry

One of the science goals of NASA's Navigator program is ground-based narrow-angle astrometry for extra-solar planet detection, which could be done as part of the proposed Outrigger Telescopes Project. The narrow-angle measurement process, which would use the outrigger telescopes, starts with the determination of the conventional interferometer astrometric baseline, determined from wide-angle astrometry of Hipparcos stars. A baseline monitor system would be employed at each outrigger telescope. This system monitors the pivot point of each telescope - the end point of the astrometric baseline - to measure telescope imperfections that would cause the baseline to vary with telescope rotation. The baseline monitor includes azimuth and elevation cameras that monitor runout along the azimuth and elevation axes of the telescopes. In conjunction with the baseline monitor system, a pivot monitor camera in the dual-star module is used to register the laser metrology corner-cube reflector to the telescope pivot, tying the narrow-angle baseline, which applies to the narrow-angle astrometric measurement, to the wide-angle baseline. In this paper we present the proposed designs for the baseline monitor and pivot-point camera.

pivot point

Adverse Effects in Dual-Star Interferometry

Narrow-angle dual-star interferometric astrometry can provide very high accuracy in the presence of the Earth's turbulent atmosphere. However, to exploit the high atmospherically-limited accuracy requires control of systematic errors in measurement of the interferometer baseline, internal OPDs, and fringe phase. In addition, as high photometric SNR is required, care must be taken to maximize throughput and coherence to obtain high accuracy on faint stars. This article reviews: the keys aspects of the dual-star approach and implementation; the main contributors to the

phase referencing

Recent Results of the Guide-2 Telescope Testbed for the SIM-Lite Mission

The Space Interferometry Mission Planet QuestLite (SIM-Lite) is a new mission concept to perform microarcsecond narrow-angle astrometry to search approximately 50 nearby stars for Earth-like planets, and also to perform a global astrometry. The SIM-Lite consists of two Michelson interferometers and one telescope. The main six-meter baseline science interferometer observes a target star and a set of reference stars. The four-meter baseline interferometer (Guide-1) monitors the attitude of the instrument in the direction of a target star. A new Guide-2telescope (G2T) tracks a bright star to monitor the attitude of the instrument in the other two orthogonal directions. In the current mission concept, the G2T consists of a 30 cm siderostat and a 30 cm confocal telescope, similar to other four telescopes used in the science and Guide-1interferometers. A testbed has been built to demonstrate the G2T feasibility for SIM-Lite mission. Recent results show that field-independent, star-tracking capability of the system is less than 30 (mu)as after the SIM narrow angle analysis.

Guide-2 Telescope

Palomar Testbed Interferometer

The Palomar Testbed Interferometer (PTI) is an infrared, phase-tracking interferometer in operation at Palomar Mountain since July 1995. It was funded by NASA for the purpose of developing techniques and methodologies for doing narrow-angle astrometry for the purpose of detecting extrasolar planets.

optical

Recent Status of SIM Lite Astrometric Observatory Mission: Flight Engineering Risk Reduction Activities

The SIM Lite Astrometric Observatory is a mission concept for a space-borne instrument to perform micro-arc-second narrow-angle astrometry to search 60 to 100 nearby stars for Earth-like planets, and to perform global astrometry for a broad astrophysics program. The instrument consists of two Michelson stellar interferometers and a telescope. The first interferometer chops between the target star and a set of reference stars. The second interferometer monitors the attitude of the instrument in the direction of the target star. The telescope monitors the attitude of the instrument in the other two directions. The main enabling technology development for the mission was completed during phases A & B. The project is currently implementing the developed technology onto flight-ready engineering models. These key engineering tasks will significantly reduce the implementation risks during the flight phases C & D of the mission. The main optical interferometer components, including the astrometric beam combiner, the fine steering optical mechanism, the path-length-control and modulation optical mechanisms, focal-plane camera electronics and cooling heat pipe, are currently under development. Main assemblies are built to meet flight requirements and will be subjected to flight qualification level environmental testing (random vibration and thermal cycling) and performance testing. This paper summarizes recent progress in engineering risk reduction activities.

astrometry

SIM PlanetQuest: Science with the Space Interferometry Mission

SIM - the Space Interferometry Mission - will perform precision optical astrometry on objects as faint as R magnitude 20. It will be the first space-based astrometric interferometer, operating in the optical band with a 10-m baseline. The Project is managed by the Jet Propulsion Laboratory, California Institute of Technology, in close collaboration with two industry partners, Lockheed Martin Missiles and Space, and TRW Inc., Space and Electronics Group. Launch of SIM is currently planned for 2009. In its wide-angle astrometric mode, SIM will yield 4 microarcsecond absolute position and parallax measurements. Astrometric planet searches will be done in a narrow-angle mode, with an accuracy of 4 microarcseconds or better in a single measurement. As a pointed rather than a survey instrument, SIM will maintain.its astrometric accuracy down to the faintest, magnitudes, opening up the opportunity for astrometry of active galactic nuclei to better than 10 pas. SIM will define a new astrometric reference frame, using a grid of approximately 1500 stars with positions accurate to 4 microarcseconds. The SIM Science Team comprises the Principal Investigators of ten Key Projects, and five Mission Scientists contributing their expertise to specific areas of the mission. Their science programs cover a wide range of topics in Galactic and extragalactic astronomy. They include: searches for low-mass planets - including analogs to our own solar system - tlie formation and dynamics of our Galaxy, calibration of the cosmic distance scale, and fundamental stellar astrophysics. All of the science observing on SIM is competitively awarded; the Science Team programs total about 40% of the total available, and the remainder will be assigned via future NASA competitions. This report is a compilation of science summaries by members of the Science Team, and it illustrates the wealth of scientific problems that microarcsecond-precision astrometry can contribute to. More information on SIM, including copies of this report, may be obtained from the project web site, at http://sim. jpl.nasa.gov.

Unwin, Stephen

A New Approach to Micro-arcsecond Astrometry with SIM Allowing Early Mission Narrow Angle Measurements of Compelling Astronomical Targets

The Space Interferometry Mission (SIM) is capable of detecting and measuring the mass of terrestrial planets around stars other than our own. It can measure the mass of black holes and the visual orbits of radio and x-ray binary sources. SIM makes possible a new level of understanding of complex astrophysical processes. SIM achieves its high precision in the so-called narrow-angle regime. This is defined by a 1 degree diameter field in which the position of a target star is measured with respect to a set of reference stars. The observation is performed in two parts: first, SIM observes a grid of stars that spans the full sky. After a few years, repeated observations of the grid allow one to determine the orientation of the interferometer baseline. Second, throughout the mission, SIM periodically observes in the narrow-angle mode. Every narrow-angle observation is linked to the grid to determine the precise attitude and length of the baseline. The narrow angle process demands patience. It is not until five years after launch that SIM achieves its ultimate accuracy of 1 microarcsecond. The accuracy is degraded by a factor of approx. 2 at mid-mission. Our work proposes a technique for narrow angle astrometry that does not rely on the measurement of grid stars. This technique, called Gridless Narrow Angle Astrometry (GNAA) can obtain microarcsecond accuracy and can detect extra-solar planets and other exciting objects with a few days of observation. It can be applied as early as during the first six months of in-orbit calibration (IOC). The motivations for doing this are strong. First, and obviously, it is an insurance policy against a catastrophic mid-mission failure. Second, at the start of the mission, with several space-based interferometers in the planning or implementation phase, NASA will be eager to capture the public's imagination with interferometric science. Third, early results and a technique that can duplicate those results throughout the mission will give the analysts important experience in the proper use and calibration of SIM.

Shaklan, Stuart

High-precision early mission narrow angle sciene with the Space Interferometry Mission

We have developed a technique that allows SIM to measure relative stellar positions with an accuracy of 1 micro-arcsecond at any time during its 5-yr mission. Unlike SIM's standard narrow-angle approach, Gridless Narrow Angle Astrometry (GNAA) does not rely on the global reference frame of grid stars that reaches full accuracy after 5 years. GNAA is simply the application of traditional single-telescope narrow angle techniques to SIM's narrow angle optical path delay measurements. In GNAA, a set of reference stars and a target star are observed at several baseline orientations. A linearized model uses delay measurements to solve for star positions and baseline orientations. A conformal transformation maps observations at different epochs to a common reference frame. The technique works on short period signals (P=days to months), allowing it to be applied to many of the known extra-solar planets, intriguing radio/X- ray binaries, and other periodic sources. The technique's accuracy is limited in the long-term by false acceleration due to a combination of reference star and target star proper motion. The science capability 1 micro-arcsecond astrometric precision - is unique to SIM.

Space Interferometry Mission

SIM spectral characteristics and accuracy analysis

The Space Interferometry Mission (SIM) will perform global astrometry (full sky), local wide-angle (15 degree) and narrow-angle (1 degree) observations to search extra-solar planets, and can calibrate stellar and galactic evolution theories. The astrometric accuracy of the SIM mission depends on spectral characteristics of the optics, detectors and targets. This paper will discuss the photometric throughput of the SIM instrument, and analyze effects of wavefront errors, optical mismatches and control biases as a function of wavelength. The color dependence models of the instrument optics including mirrors, lenses, field-stop and beam-splitter are presented. The performances of different detectors with a variety of coatings are compared. A model of the SIM fringe spectrometer is created. For early and late types of stars, brightness dependency errors are analyzed for different combinations of optics and detectors. Visibility loss due to imperfect optics is investigated in detail. Based on the models of instrument and estimated visibilities, the astrometric accuracies for various kinds of stars are evaluated. It is important to emphasize that not only light sources, mirrors, lenses, field stop and detectors are all wavelength dependent, but also fringe visibility loss, wavefront error, optics control error, etc. are all a function of wavelengths. For the first time the estimate of SIM performance is based on spectral analysis of all factors above, rather than monochromatic approximations of detected fringes, or simply adopted constants. This paper summarizes the astrometric accuracies for a wide range of stars and various combinations of optical design and detector configurations. It has been verified that SIM has astrometric accuracy of about 4 μas for targets with different spectra.

Shao, Michael