Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inverted potentials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Efficient and reversible electron bifurcation with either normal or inverted potentials at the bifurcating cofactor

A longstanding mystery surrounding electron bifurcation is the significance of inverted (or “crossed”) reduction potentials of the two-electron bifurcating cofactor. Using a many-electron open-system kinetic model, we show that reversible and efficient electron bifurcation is possible without inverted reduction potentials at the bifurcating site if the absolute value of the difference between first and second reduction potentials of the bifurcating species is sufficiently large (on the scale of the redox-potential span of the high- and low-potential branches). Surprisingly, the case with strong, normally ordered potentials at the bifurcating cofactor can produce electron bifurcation that is just as effective as the case with strongly inverted potentials. Lastly, this finding amplifies the puzzle surrounding the recruitment of inverted potentials in the few well-characterized bifurcating systems of nature and suggests that electron bifurcating cofactors without strongly inverted potentials may yet be discovered.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of a high power inverter for potential space applications

The ADM-006 inverter discussed utilizes a unique method of using power switching circuits to produce three-phase low harmonic content voltages without any significant filtering. This method is referred to as the power center approach to inverter design and is explained briefly. The results are presented of tests performed by MSFC to evaluate inverter performance, especially when required to provide power to nonlinear loads such as half or full wave rectified loads with capacitive filtering. Test preocedures and results are described. These tests show that the power center inverter essentially met or exceeded all of claims excluding voltage regulation (3.9 percent versus specified 3.3 percent) and would be a good candidate for high power inverter applications such as may be found on Space Station, Spacelab, etc.

Guynes, B. V.↗

Analysis of the Measurement and Modeling of a Digital Inverter Based on a Ferroelectric Transistor

The use of ferroelectric materials for digital memory devices is widely researched and implemented, but ferroelectric devices also possess unique characteristics that make them have interesting and useful properties in digital circuits. Because ferroelectric transistors possess the properties of hysteresis and nonlinearity, a digital inverter containing a FeFET has very different characteristics than one with a traditional FET. This paper characterizes the properties of the measurement and modeling of a FeFET based digital inverter. The circuit was set up using discrete FeFETs. The purpose of this circuit was not to produce a practical integrated circuit that could be inserted directly into existing digital circuits, but to explore the properties and characteristics of such a device and to look at possible future uses. Input and output characteristics are presented, as well as timing measurements. Comparisons are made between the ferroelectric device and the properties of a standard digital inverter. Potential benefits and possible uses of such a device are presented.

MacLeod, Todd C.↗

The influence of protein electrostatics on potential inversion in flavoproteins

Biology uses relatively few electron-transfer cofactors, tuning their potentials, electronic couplings, and reorganization energies to carry out the required chemistry. It is remarkable that the potential ordering of two-electron transfer active flavins can be normal (first oxidation at low potential and second oxidation at high potential) or inverted, and the gap between the potentials can be as large as one volt. Analysis based on structural bioinformatics and electrostatics indicates that the ordering of the flavin redox potential is influenced by protein electrostatics. In all 36 flavoproteins examined, the introduction of a negative charge near the flavin in silico increases the extent of potential inversion (by lowering the electrochemical potential of the second electron-transfer step); the introduction of a positive charge near the flavin favors normally ordered potentials. We also find that the addition of positive charges increases the electrochemical potential for the naturally occurring one-electron transition in flavodoxins (between deprotonated hydroquinone and neutral semiquinone) and also increases the second one-electron transition in bifurcating flavins (between anionic semiquinone and fully oxidized flavin). Finally, we find that proximity of a proton acceptor, notably conserved arginine, supports proton-coupled electron transfer because it may act as a proton acceptor, promoting potential inversion. This key arginine residue may enable two-electron transfer chemistry by promoting the proton-coupled electron transfer process over the pure electron transfer process, suggesting how a protein's flavin environment may influence one- or two-electron chemistry in flavoproteins.

Singh, Niven [Duke Univ., Durham, NC (United State↗

Smart Inverter Twin Model for Anomaly Detection

Smart inverters connected to a communication network are vulnerable to various anomalies in the form of cyberattacks. In this paper, a self-security approach is implemented using the digital twin concept for smart inverters. The digital twin is formed using the inverter’s dynamic model. Then, the incoming setpoints are autonomously examined using the digital twin, and only the safe setpoints are engaged to the inverter’s local controller. This paper demonstrates the details of the self-security algorithm and how the inverter’s digital twin is formed. In particular, the stable and unstable operation region is experimentally verified by changing the power setpoints engaged to the local controller, using a laboratory setup including a three-phase 1.5-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative power grid emulator. The results demonstrate that the digital twin model can potentially protect inverters from abnormal operation by examining the incoming commands (new setpoints) using the inverter’s digital twin before engaging the setpoints to the local controller.

Hossen, Tareq↗

Digital Twin for Self-Security of Smart Inverters

Smart inverters connected to a communication network are susceptible to man-in-the-middle attacks. In this paper, a self-security approach is implemented using the digital twin concept for smart inverters. The digital twin is formed using the inverter’s normal operating region and the inverter’s dynamic model. Then, the incoming setpoints are autonomously examined using the digital twin, and only the safe setpoints are engaged to the inverter’s local controller. This paper demonstrates how the inverter’s normal operating region and dynamic model are formed. In particular, the normal operation region is experimentally verified by changing the P and Q setpoints engaged to the local controller, using a laboratory setup including a three-phase 3-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative power grid emulator. The results demonstrate that the self-security technique can potentially protect inverters from man-in-the-middle attacks by examining the incoming commands (new setpoints) using the inverter’s digital twin before engaging the setpoints to the local controller.

Hossen, Tareq↗

Advances in series resonant inverter technology and its effect on spacecraft employing electric propulsion

The efficiency of transistorized Series Resonant Inverters (SRIs), which is higher than that of silicon-controlled rectifier alternatives, reduces spacecraft radiator requirements by 40% and may eliminate the need for heat pipes on 30-cm ion thruster systems. Recently developed 10- and 25-kW inverters have potential applications in gas thrusters, and represent the first spaceborne SRI designs for such power levels. Attention is given to the design and control system approaches employed in these inverter designs to improve efficiency and reduce weight, along with the impact of such improved parameters on electric propulsion systems.

Robson, R. R.↗

An SCR inverter with an integral battery charger for electric vehicles

The feasibility of incorporating an onboard battery charger into the inverter previously developed under a NASA contract is successfully demonstrated. The rated output power of the resulting isolated battery charger is 3.6 kW at 220 Vac with an 86 percent efficiency and a 95 percent power factor. Also achieved are improved inverter efficiency (from 90 to 93 percent at 15 kW motor shaft power), inverter peak power capability (from 26 to 34 kW), and reduced weight and volume of the combined inverter/charger package (47 kg, 49 x 44 x 24 cm). Some major conclusions are that using the inverter commutation circuitry to perform the battery charging function is advantageous, and that the input-commutated thyristor inverter has the potential to be an excellent inverter and battery charger for use in electric vehicle applications.

Thimmeach, D.↗

Energy transduction by reversible electron bifurcation

Electron bifurcation is a biological energy conversion process that oxidizes a two-electron donor at medium potential, coupled to the reduction of a high- and a low-potential acceptor species. This process is often fully reversible (can occur close to ΔG ≈ 0), allowing the creation of strong reductants with minimal free energy cost, using compounds with higher reduction potentials. For many years, the internal workings of electron bifurcating enzymes were poorly understood, especially regarding how short-circuit reactions are prevented. Recently, a conserved energy landscape was proposed to naturally insulate against short-circuit reactions, enabling efficient and reversible electron bifurcation (the reversible EB scheme). Here, we review the physical principles that underpin the EB scheme, describe how the reversible EB scheme is distinct from previous views, and outline questions that remain open.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Black hole induced false vacuum decay from first principles

We provide a method to calculate the rate of false vacuum decay induced by a black hole. The method uses complex tunneling solutions and consistently takes into account the structure of different quantum vacua in the black hole metric via boundary conditions. The latter are connected to the asymptotic behavior of the time-ordered Green’s function in the corresponding vacua. We illustrate the technique on a two-dimensional toy model of a scalar field with inverted Liouville potential in an external background of a dilaton black hole. We analytically derive the exponential suppression of tunneling from the Boulware, Hartle-Hawking and Unruh vacua and show that they are parametrically different. The Unruh vacuum decay rate is exponentially smaller than the decay rate of the Hartle-Hawking state, though both rates become unsuppressed at high enough black hole temperature. We interpret the vanishing suppression of the Unruh vacuum decay at high temperature as an artifact of the two-dimensional model and discuss why this result can be modified in the realistic case of black holes in four dimensions.

2D Gravity↗

Disentangling multiple scattering with deep learning: application to strain mapping from electron diffraction patterns

Abstract A fast, robust pipeline for strain mapping of crystalline materials is important for many technological applications. Scanning electron nanodiffraction allows us to calculate strain maps with high accuracy and spatial resolutions, but this technique is limited when the electron beam undergoes multiple scattering. Deep-learning methods have the potential to invert these complex signals, but require a large number of training examples. We implement a Fourier space, complex-valued deep-neural network, FCU-Net, to invert highly nonlinear electron diffraction patterns into the corresponding quantitative structure factor images. FCU-Net was trained using over 200,000 unique simulated dynamical diffraction patterns from different combinations of crystal structures, orientations, thicknesses, and microscope parameters, which are augmented with experimental artifacts. We evaluated FCU-Net against simulated and experimental datasets, where it substantially outperforms conventional analysis methods. Our code, models, and training library are open-source and may be adapted to different diffraction measurement problems.

36 MATERIALS SCIENCE↗

Characteristics of auroral electron acceleration regions observed by Atmosphere Explorer C

Satellite measurements of electron precipitation and ion drift velocities showed that electron acceleration regions (or inverted V's) in the 1200 to 1800 MLT quadrant exhibit the following systematic behavior: electron distribution functions in the accelerated region can be well described by Maxwellian primary electron beams accelerated through an electrostatic potential; the typical inverted V latitudinal structure is always observed in the accelerated regions, the electrostatic potential reaching a maximum and consequently decreasing to near zero over distances of 100 to 250 km; the Maxwellian temperature of the primary electron beam increases systematically with increasing electrostatic potential; rather weak acceleration regions, characterized by values of the electrostatic potential below 1 keV and values of the Maxwellian temperature between 100 and 350 eV, occur in the cusp and in the highest-latitude portion of the dusk side electron precipitation zone.

Burch, J. L.↗

Experimental Analysis of Distribution Network Voltage Regulation Using Smart Inverters

Smart inverters (SIs) have demonstrated their potential to provide grid services for both transmission and distribution systems. One of these grid services, distribution network voltage regulation by SIs, has the potential to improve network voltage regulation through controlling the reactive and active power output of the SIs. Voltage regulation by SIs will be distributed and might be better suited to controlling local conditions to complement traditional voltage-regulating assets, e.g., tap-changing transformers, capacitor banks, and line voltage regulators. There is a gap in the literature on comparing the SI response characteristics when the SIs are controlled by a local controller or external control signals. This paper presents an experimental study to characterize SI reactive power regulation responses to two different control methods: autonomous control and remote dispatch. We found that SI reactive power regulation responses exhibit important differences between these methods in terms of delays and ramp rate. Finally, power-hardware-in-the-loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL test results show that the SI response characteristics for autonomous control and remote dispatch need to be considered when planning for distribution network voltage regulation using SIs.

autonomous control↗

Aging Effect Analysis of PV Inverter Semiconductors for Ancillary Services Support

PV inverters can provide reactive power while generating active power. An ongoing microgrid implementation at Duke Energy actively engages non-utility PVs to generate/absorb reactive power in support of ancillary services to increase microgrid resiliency during extreme events. PV systems are requested to provide reactive power support: 1) in response to grid voltage variation to better regulate the local voltage; or 2) in response to utility incentives, such as following Transactive Energy System (TES) incentives. However, providing ancillary services might shorten the lifetime expectation of PV inverter semiconductors. This paper summarizes the potential impacts on a PV inverter semiconductor's lifetime when providing ancillary services. The analysis presented in this research work shows that providing reactive power support will increase the mean junction temperature and the junction temperature variation of the inverter diodes. This increased junction temperature will eventually lead to shorter diode lifetime. The lifetime estimation of semiconductors is briefly reviewed. The power losses of PV inverter semiconductors are derived as a support analysis to the junction temperature calculation. In addition, the impact of the filtering inductor on the semiconductor current distribution is discussed. The theoretical analysis presented in this research work is supported by simulation results.

14 SOLAR ENERGY↗

Analytic model of aurorally coupled magnetospheric and ionospheric electrostatic potentials

This paper describes modest but significant improvements on earlier studies of electrostatic potential structure in the auroral region, using the adiabatic auroral arc model. With certain simplifying assumptions, new analytic nonlinear solutions fully exhibiting the parametric dependence of potentials on magnetospheric (e.g., cross-tail potential) and ionospheric (e.g., recombination rate) parameters are found. No purely phenomenological parameters are introduced. The results are in reasonable agreement with observed average auroral potential drops, inverted-V scale sizes, and dissipation rates. The dissipation rate is quite comparable to tail energization and transport rates and should have a major effect on tail and magnetospheric dynamics. Various relations between the cross-tail potential and auroral parameters (e.g., total parallel currents and potential drops) are given which can be studied with existing data sets.

Cornwall, John M.↗

Intrusion Detection for Cybersecurity of Power Electronics Dominated Grids: Inverters PQ Set-Points Manipulation

This work provides cybersecurity analytics for a high photovoltaic (PV) penetrated distribution network, representing future power electronics dominated grid (PEDG). Firstly, the impact of active and reactive power (PQ) set-points manipulation on the network is studied. Then, an intrusion detection system (IDS) is developed for identifying the potentially compromised PV inverters in the network. The proposed IDS is based on defining the normal, safe, and abnormal operation regions of the PV inverters from point of view of the steady state voltage stability of the network. These three-operation regions are identified by utilizing active power, reactive power, and voltage (PQV) limits of each specific grid-following inverter in the network. Each grid-following inverter's PQV contour includes the information of network topology, inverter ratings, and inverter controller. The developed PQ limits are integrated into the centralized secondary control layer for realization of the proposed IDS. Furthermore, the proposed secondary control layer is capable of providing remedial actions during an anomaly event to enhance the grid resiliency. The theoretical analyses are verified by several attack scenarios for a network of grid-following inverters.

41 EE - Solar Energy Technologies Office (EE-4S)↗