Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ion Chromatography (IC)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ion Chromatography (IC) Round Robin Analyses of Low Glycolate Concentrations in Recycle Collection Tank (RCT) Post Permanganate Treatment Simulant

This work is a demonstration of Ion Chromatography (IC) analysis of low concentrations of glycolate in chemical simulant designed to mimic the matrix in the Recycle Collection Tank (RCT) at the Defense Waste Processing Facility (DWPF) after sodium permanganate oxidation treatment. The IC method was previously developed [1] and this report covers the results of round robin testing with three analytical laboratories located at the Savannah River Site (SRS). The laboratories are termed the Sensing & Metrology (S&M) laboratory at the Savannah River National Laboratory (SRNL), the Processing Science Analytical Laboratory (PSAL) at SRNL, and the DWPF laboratory at SRS. Each laboratory received four samples: (1) 200 mL of 21.3 mg/L glycolate in RCT post permanganate strike sulfite quenched simulant, (2) 200 mL of 38.0 mg/L glycolate in RCT post permanganate strike sulfite quenched simulant, (3) 200 mL of 54.9 mg/L glycolate in RCT post permanganate strike sulfite quenched simulant, and (4) 600 mL of RCT post permanganate strike sulfite quenched simulant to use for matrix matched blanks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Glycolate in Radioactive Waste by Ion Chromatography (IC) and Proton Nuclear Magnetic Resonance (H NMR)

Here, in preparation for implementing the Nitric-Glycolic (NG) acid flowsheet for the Savannah River Site (SRS) Liquid Waste System (LWS), analytical methods for determining glycolate at low concentration, below 20 mg/L in radioactive samples, were developed to support system management and safety. To accommodate the wide range of LWS matrix conditions, two alternative methods were developed, refined, and demonstrated for glycolate analysis in radioactive waste samples: ion chromatography (IC) and a proton nuclear magnetic resonance (H NMR). Investigators validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. The deployed IC method is applicable in low to moderate ionic strength samples and requires sample pretreatment using a Dionex OnGuard II H + cartridge. The deployed H NMR method is more labor intensive but provides options for a broader range of matrices. Based on the results, high quality glycolate analysis of the Defense Waste Processing Facility (DWPF) condensate in Tank 22 is feasible by IC down to approximately 12 mg/L. Using H NMR, glycolate may be determined to 8 mg/L or lower depending on the run time with the potential for broader applicability of the method to higher ionic strength conditions in other tanks of the SRS LWS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Ion Chromatography and Combustion Ion Chromatography Analysis of Fuel Cell Effluent Water During Open Circuit Voltage

Open circuit voltage tests were conducted on sixteen 3M Ionomer and eight Nafion™ NR211 membranes. Lifetime distributions were determined, and ion chromatography (IC) techniques were used to measure fluoride, sulfate, trifluoro acetate, and oxalate ions. Combustion Ion Chromatography (CIC) was used to determine the total organic fluoride (TOF) associated with water soluble membrane degradation fragments. The ratio of these products relative to the fluoride release rates were used to infer the likely degradation mechanism for each membrane. Peroxide attack at the sulfonic acid side chain was determined to be the least relevant reaction pathway while the long-proposed polymer chain end unzipping appears to be the dominant mechanism. Abstraction of the tertiary fluorine in the NR211 backbone and side chain is evident by organic fluoride release rates higher than can be explained by unzipping alone.

25 ENERGY STORAGE↗

Glycolate Analysis in Tank 22: Developing and Testing Analytical Methods for the Savannah River Site Liquid Waste System

Researchers developed and tested a range of techniques to support a low mg/L Limit of Quantitation (LOQ) of glycolate in radioactive Tank 22 waste solution by Ion Chromatography (IC) and by proton NMR. For the IC method, Dionex OnGuard II cartridges were tested as a means of removing alkali earth and transition metals that can interfere during ion chromatography applications especially when analyzing for low-concentration, chelating analytes. Additionally, concentrations of nitrate in the raw Tank 22 sample (5,000 to 10,000 mg/L) were managed by using reasonable levels of sample dilution. The resulting IC performance quality was enhanced by improving the baseline, increasing sensitivity [Limit of Quantitation (LOQ) of 12 mg/L and Limit of Detection (LOD) of 4.0 mg/L], and resolving analytes into well-defined Gaussian peaks when using the Dionex OnGuard II H⁺ cartridges to remove matrix interferences. High concentrations of nitrate limited the performance of the IC method. To achieve an acceptable baseline, samples with high nitrate content require more dilution, resulting in higher detection limits. Tests on samples with higher concentrations of nitrate (Tank 30 and 32 supernate with approximately 150000 mg/L nitrate) suggested that IC detection limits for glycolate in these samples would be > 500 mg/L. Thus, an LOQ of 12 mg/L is not feasible by this IC method on evaporator feed samples. An alternative method of glycolate analysis, using proton nuclear magnetic resonance (H NMR), was developed by the research team. In initial tests, the H NMR technique provided reasonable quantitation of glycolate in Tank 22 conditions by direct observation of the liquid. The H NMR method may provide improved detection limits for solutions with higher nitrate concentrations. We recommend further development of this analysis for high nitrate LWS samples such as evaporator feed and evaporator drop tank content. A method for pretreatment of samples using crystalline silicotitanate (CST) was developed and tested. The objective of the pretreatment was to facilitate analysis of samples with higher levels of radioactivity. The pretreatment did not influence the glycolate concentration in solution, and the pretreatment is projected to reduce Cs 137 activity in a sample by a factor of 16,200. The double strike CST pretreatment was demonstrated and would allow milliliters of higher activity samples to be transferred from the Shielded Cells and handled in a containment unit for glycolate analysis. The various studies validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. Based on the results, high quality glycolate analysis of Tank 22 is feasible down to approximately 12 mg/L, with the potential for broader applicability of the methods to other conditions in the Savannah River Site Liquid Waste System (LWS).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oxidation of Glycolate in the Defense Waste Processing Facility (DWPF) Recycle Collection Tank - 20305

The Savannah River Site's Defense Waste Processing Facility (DWPF) operations are being upgraded with the introduction of the Nitric-Glycolic Flowsheet. Glycolic acid has been shown superior to formic acid as the reducing acid used during chemical processing. The new flowsheet improves or maintains necessary parameters such as 1) reduction of mercury, 2) adjustment of feed rheology and 3) adjustment of melter oxidation/reduction potential. Further, the potential for catalytic hydrogen generation in DWPF processing is virtually eliminated. DWPF process condensates are collected and returned to the SRS Concentration, Storage and Transfer Facilities (CSTF). The Recycle Collection Tank (RCT) collects off-gas condensate during chemical processing, vitrification, and other unit operations performed in DWPF and is the singular return vessel delivering recycle effluent back to CSTF. Each batch of recycle may contain a small amount of glycolate from chemical processing and melter off-gas condensates. To avoid potential flammability issues due to thermolysis of glycolate in the CSTF, chemical oxidation within the RCT has been investigated as an option for mitigating the transfer of glycolate. Sodium permanganate has been down-selected as the best option for oxidation of glycolate. Testing was performed using both 2-L and 22-L reactors (16,800:1 and 1,530:1 scale by volume) with non-radioactive waste simulants to approximate the expected RCT compositions. RCT simulants were evaluated at various process pH and temperature conditions. Also, RCT operations, namely the sequence of addition of corrosion inhibitors (NaOH and NaNO{sub 2}) versus a permanganate strike, were evaluated. Glycolate was introduced via a sludge simulant to mimic both expected entrainment and abnormal process foam-over conditions - the range being between 68 and 5100 mg/kg glycolate. Glycolate destruction was monitored by ion chromatography (IC). The corresponding manganese behavior was monitored in real-time using in situ ultraviolet-visible (UV-Vis) spectroscopy. RCT glycolate content can be reduced to below the IC detection limit within 90 minutes for all concentrations investigated. Ion Chromatography analysis revealed that under alkaline conditions, glycolate is primarily oxidized to oxalate with no significant formation of CO{sub 2} or carbonate, and nitrite is not oxidized to nitrate. Initially, complete oxidation of organics species and nitrite was assumed. Determination of the mechanistic chemical reaction has allowed the required amount of permanganate to be more accurately predicted and the total addition to be significantly reduced. UV-Vis measurements reveal that permanganate (Mn{sup 7+}) is reduced to manganate (Mn{sup 6+}) in the RCT. The oxidant stoichiometry is defined by using the initial permanganate to glycolate (P/G) molar ratio. At low initial glycolate concentration (68 and 140 mg/kg), the minimum required initial permanganate to glycolate (P/G) molar ratio was found to be 5-6. With high initial glycolate concentrations (5100 mg/kg) a lower (P/G) molar ratio of ∼2.5 was needed. The final portion of this effort supporting the nitric/glycolic flowsheet will be to test actual (fully radioactive) RCT samples as per the above simulant tests. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chelation ion chromatography as an automated, and cost-effective analytical technique for REE determination: method development and applications

Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.

detection of rare earth elements (REE)↗

Determination of transition metal ions in fossil fuel associated wastewaters using chelation ion chromatography

Here, this study outlines the development and subsequent validation of a method using chelation ion chromatography (CIC) pretreatment followed by traditional ion chromatography (IC) and post column UV/vis detection to measure transition metals in fossil fuel wastewaters, such as oil & gas (O&G) brines and coal mine drainage (CMD) waters. Measurement of transition metals is often an important characterization step in the research of environmental and energy systems. IC represents one way to measure these metals with the advantages of being versatile, simple and relatively low cost compared to other analytical methods. However, high concentrations of alkali and alkaline earth metals present in fossil fuel wastewaters will decrease IC detectability of transition metals in these waters. In this study, a CIC method was developed for the analysis of transition metal ions (Fe 3+ , Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , Mn 2+ , and Fe 2+ ) in fossil fuel associated wastewaters such as Appalachian CMD and O&G wastewaters from the Permian and Bakken shale basins in the United States. CIC system incorporated an on-line chelator column (e.g., the MetPac CC-1) with high selectivity for transition metals over alkali and alkaline earth metals for salt matrix removal prior to transition metal separation and detection. Additional method developments also included acidifying all samples to 2% v/v HCl and using gradient elution rather than isocratic. The recoverability of transition metals in simple salt solutions commonly found in CMD and brine samples (e.g. NaCl, Na 2 SO 4 , CaCl 2 ) using CIC was evaluated and compared to that using traditional IC. Our results found that the CIC system significantly improved transition metal recoveries for samples in 10,000 mg/L CaCl 2 matrix, reaching 87%-108% recovery for all analytes, as opposed to 2-323% recovery in traditional IC. The limits of detection in this study achieved 10.09 – 161.2 μg/L, comparable to reported values in similar IC studies. The developed method was also verified with certified water samples, resulting in 89% - 111% recoveries in samples with higher analyte concentrations (i.e. >4x the LoDs). The developed method achieved 87% -112% recoveries for most analytes in CMD samples and 72%-138% recoveries for Bakken shale samples, relative to ICP-MS values. Overall, the current IC method can be a very good screening tool for fast and cheap analysis for transition metals at mg/L level, to facilitate selection of samples for more detailed ICP-MS analysis.

01 COAL, LIGNITE, AND PEAT↗

Total metal, carbon, anion, iron speciation, and sulfide concentrations; Slate River, East River, and Trail Creek surface water and floodplains, Crested Butte, CO; May 2023–August 2023

This data package comprises analytical results and metadata from stream and groundwater samples collected from the Slate River, East River, Trail Creek, and their respective floodplains. This dataset contains five files: (1) a samples file (2023_SFA_Field_samples.csv) that contains site information; (2) a chemical analysis data file (2023_FieldWaterSampleData_IC__ICPOES__ICPMS__TOC__Fe__S_chem_data.csv) that contains sample analysis values; (3) a file-level metadata file (flmd.csv) that lists each file contained in the dataset with associated metadata; (4) a data dictionary file (dd.csv) that contains column/row headers used throughout the files along with definitions, units, and data types; and (5) a methods file (methods.csv) that contains ID, type, description, instrument, and lab information for each method.The samples’ anion concentrations were measured using ion chromatography (IC), total metal concentrations using inductively coupled plasma emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS), non-purgeable organic carbon using total organic carbon (TOC) analysis, dissolved sulfide concentration using methylene blue spectrophotometry, and iron speciation using the ferrozine assay. To support bulk chemical analyses and colloid characterization, samples were collected from multiple depths ranging from the surface to 3.5 meters below ground.Update on 2024-10-18: Updates were made to the 2023_FieldWaterSampleData_IC__ICPOES__ICPMS__TOC__Fe__S_chem_data.csv and dd.csv files to correct units (ppb instead of ppm).

54 ENVIRONMENTAL SCIENCES↗

African dust transported to Barbados in the wintertime lacks indicators of chemical aging

The chemical processing (“aging”) of mineral dust is thought to increase dust light-scattering efficiency, cloud droplet activation, and nutrient solubility. However, the extent of African dust aging during long-range transport to the western Atlantic is poorly understood. Here, we explore African dust aging in wintertime samples collected from Barbados when dust is transported at lower altitudes. Ion chromatography (IC) analysis indicates that the mass concentrations of bulk nitrate, sulfate, and oxalate increase, relative to background conditions, when African dust reaches Barbados after transatlantic transport, indicating dust aging. However, aerosol mixing-state analysis from computer-controlled scanning electron microscopy with energy dispersive X-ray spectroscopy (CCSEM/EDX) indicates that approximately 67 % of dust particles are internally mixed with sea salt, while only about 26 % of dust particles contain no internally mixed components. SEM/EDX elemental mapping and time-of-flight secondary ion mass spectrometry (TOF-SIMS) reveals that within internally mixed dust and sea salt particles, only sea salt components contain signs of aging as indicated by the loss of chloride and acquisition of nitrate and/or sulfate. Our results suggest that chemical aging may only modestly increase the solubility of nutrients in African dust during long-range transport. Because most dust that we measured was internally mixed with sea salt, chemical aging is not necessarily required to increase the hygroscopicity of dust, at least in the lower boundary layer. Further, our findings have implications for understanding the release of halogens from sea salts, which may be enhanced in internally mixed dust and sea salt particles.

54 ENVIRONMENTAL SCIENCES↗

Cathodic NH 4 + leaching of nitrogen impurities in CoMo thin-film electrodes in aqueous acidic solutions

Electrocatalytic reduction of dinitrogen (N 2 ) to ammonium (NH 4 + ) in acidic aqueous solutions was investigated at ambient temperature and pressure using a cobalt–molybdenum (CoMo) thin-film electrode prepared by magnetron reactive sputtering. Increased concentrations of ammonium ions (NH 4 + ) were consistently detected in the electrolyte using ion chromatography (IC) after constant-potential electrolysis at various potentials (≤-0.29 V vs. RHE). Using a newly developed analytical method based on ammonia derivatization, performing the experiments with 15 N 2 -labelled gas led however to the detection of increased 14 NH 4 + concentrations instead of 15 NH 4 + . X-ray photoelectron spectroscopic (XPS) analysis of the electrode surface revealed the presence of Mo[triple bond, length as m-dash]N and Mo–NH x species. Several contamination sources were identified that led to substantial increases in the concentration of ammonium ions, including 15 NH 3 impurities in 15 N 2 gas. The observed ammonium concentrations can be consistently ascribed to leaching of nitrogen ( 14 N) impurities incorporated in the CoMo film during the sputtering process. Therefore, researchers in the field are urged to adopt extended protocols to identify and eliminate sources of ammonia contamination and to very carefully monitor the ammonium concentrations in each experimental step.

36 MATERIALS SCIENCE↗

Porous Salts as Platforms for Heterogeneous Catalysis

In this study, the preparation of a new class of reactive porous solids, prepared via straightforward salt metathesis reactions, is described here. Reaction of the dimethylammonium salt of a magnesium-based porous coordination cage with the chloride salt of [Cr II Cl(Me 4 cyclam)] + affords a porous solid with concomitant removal of dimethylammonium chloride. The salt consists of the ions combined in the expected ratio based on their charge as confirmed by UV–vis and X-ray photoelectron spectroscopies, ion chromatography (IC), and inductively coupled plasma mass spectrometry (ICP-MS). The porous salt boasts a Brunauer-Emmett-Teller (BET) surface area of 213 m 2 g -1 . Single crystal X-ray diffraction reveals the chromium(II) cations in the structure reside in the interstitial space between porous cages. Importantly, the chromium(II) centers, previously shown to react with O 2 to afford reactive chromium(III)-superoxide adducts, are still accessible in the solid state as confirmed by UV–vis spectroscopy. The site-isolated reactive centers have competence toward hydrogen atom abstraction chemistry and display significantly increased stability and reactivity as compared to dissolved ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sample Preparation Method for Low-Level Total 129 I Measurements by ICP-MS

Trace-level measurements of iodine’s isotopic ( 129 I and 127 I) and chemical species distributions are needed for an accurate understanding of radioiodine migration in the Hanford subsurface. Pacific Northwest National Laboratory (PNNL) previously developed a novel analytical method for iodine characterization that uses ion chromatography (IC) coupled to inductively coupled mass spectrometry (ICP-MS). While the method can measure speciated forms of 129 I at levels below the drinking water standard, an interference from molybdenum (Mo) prevents the assay from quantifying the $\underline{total}$ 129 I concentration in many Hanford sample matrices. In this work, solvent extraction was evaluated as a sample preparation method for eliminating the Mo interference. A series of 10 experiments was conducted in which solutions containing known amounts of iodate or iodide were treated by solvent extraction, and the extracted solutions were analyzed for total iodine concentrations by ICP MS. Several extraction parameters such as reagent concentrations and chemical reaction times were systematically adjusted in attempts to optimize the extraction process. While solvent extraction was shown to be effective at removing Mo, there was a consistent inability to recover more than approximately 75% of the total iodine in most experiments. This would reduce the ability to detect 129 I at levels near the drinking water standard. Additionally, the extraction efficiencies in several experiments were highly variable, suggesting that solvent extraction could add significant uncertainty to radioiodine measurements. We recommend evaluating ion exchange as an alternative sample preparation approach in fiscal year (FY) 2024.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Laboratory Measurements Probing Hydrogen Interactions with Eagle Ford Shale and Pyrite: Potential Implications for Subsurface Hydrogen Storage

Hydrogen (H 2 ) has the potential to be a transformative technology as an enabler to a low-carbon future and promoter of renewable energy. When H 2 is injected and stored in the subsurface, it has the potential to interact with the caprock (usually shale) which overlies and seals the storage reservoir. Here, this study examines geochemical reactions or changes in surface morphology to Eagle Ford Shale, a proxy for caprock, upon exposure to H 2 at 50°C and 10.3 MPa. Reactions were also performed with N 2 to provide an experimental control. Scanning Electron Microscopy with Energy Dispersive Spectroscopy (SEM-EDS), Atomic Force Microscopy (AFM), and Optical Photothermal-Infrared (O-PTIR) Spectroscopy were applied to quantify changes on the microscale and nanoscale level. Fluid chemistry changes were monitored with Ion Chromatography (IC) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Exposure of Eagle Ford Shale to H 2 gas alone did not result in any alterations to the shale chemically or any changes in the surface morphology. Exposure of Eagle Ford Shale to both H 2 and water as well as N 2 and water resulted in changes to the surface morphology because of gypsum dissolution and reprecipitation, thus indicating that H 2 is not necessary to promote changes. Pure pyrite was the most reactive with H 2 possibly resulting in a reduction to pyrrhotite. These initial studies suggest that the extent of reactions activated by hydrogen with caprock are minor under the temperature and pressure conditions that would represent underground hydrogen storage.

08 HYDROGEN↗

Surface Water Quality Data from Beaver-Impacted Streams; Trail Creek and East River, Colorado 2025

This data package contains surface water chemistry measurements collected in 2025 to evaluate how beaver damming and low-tech process-based stream restoration influence water quality and metal mobility in mountainous headwater systems of the Upper Colorado River Basin. Sampling was conducted at Trail Creek (Taylor Park watershed, Colorado), a tributary undergoing restoration through installation of low-tech process-based structures (i.e., beaver dam analogs), and at off-channel beaver ponds within the East River floodplain (East River watershed, Colorado). Samples were collected along longitudinal transects spanning upstream control reaches, beaver-influenced ponded reaches, and downstream segments. Additional samples were collected from near-surface pore waters within a beaver dam seepage face. The dataset includes concentrations of major and trace elements measured by inductively coupled plasma–mass spectrometry (ICP-MS) and inductively coupled plasma–optical emission spectrometry (ICP-OES), major anions measured by ion chromatography (IC), and dissolved organic carbon (DOC; reported as non-purgeable organic carbon, NPOC). Samples were size-fractionated at 0.45 micrometers (µm), 0.22 µm, and 0.02 µm to distinguish particulate (>0.45 µm), colloidal (0.22–0.02 µm), and dissolved (<0.02 µm) fractions. The data package consists of comma-separated value (.csv) files containing tabulated chemical concentration data, sample metadata (site identifiers, geographic coordinates, sampling dates, fraction type), and quality control flags. All files are provided in open, non-proprietary formats that can be accessed using standard data analysis software such as Microsoft Excel, R, Python, MATLAB, or other programs capable of reading .csv files. Units, detection limits, and analytical methods are documented in accompanying metadata files. The dataset is designed to support analyses of (1) how beaver impoundment and restoration structures alter elemental partitioning and transport, (2) the role of iron and organic carbon in mediating trace metal mobility, and (3) reach-scale changes in water quality across restoration gradients. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. Part of this work was performed at SLAC Accelerator Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-76SF00515.

Anions↗

Permanganate Oxidation of Actual Defense Waste Processing Facility (DWPF) Slurry Mix Evaporator Condensate Tank (SMECT) and Offgas Condensate Tank (OGCT) Samples to Remediate Glycolate

Savannah River Remediation (SRR) tasked Savannah River National Laboratory (SRNL) to examine glycolate destruction in radioactive samples emulating the proposed process. Experiments with radioactive Defense Waste Processing Facility (DWPF) condensates were performed to demonstrate the oxidation of glycolate using sodium permanganate. One test each was performed for Off-Gas Condensate Tank (OGCT) and Slurry Mix Evaporator Condensate Tank (SMECT) samples received. Condensates were blended with Recycle Collection Tank (RCT) heel simulant and Slurry Mix Evaporator (SME) product containing glycolate to represent typical RCT compositions with estimated nominal entrainment of glycolate. A permanganate to glycolate (P/G) molar ratio targeting 5.7 decreased sample glycolate concentration below Ion Chromatography (IC), glycolate method reporting limits in less than 2 hours for the OGCT sample and in less than 8 hours for the SMECT sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-Activity Waste Glass Standards Preparation and Characterization for Calibration of Analytical Instruments

A matrix of seven low-activity waste (LAW) glasses was fabricated and characterized to be used by the Hanford Waste Treatment and Immobilization Plant (WTP) as analytical instrument calibration and matrix interference standards when measuring LAW glass compositions. The matrix of glasses was designed to represent the range of LAW glass compositions that will be generated by the WTP. Samples from each of the seven glasses were measured with electron probe microanalysis (EPMA), ion chromatography (IC), and bulk inductively coupled plasma mass spectroscopy (ICP-MS) to determine the variability and accuracy across batches and within individually poured glass bar samples. High relative percent differences and standard deviations were calculated for components with low concentrations due to instrument detection limits. IC and ICP-MS percent differences and standard deviations were higher at low component concentrations. Otherwise, variability in measured compositions from IC and ICP-MS was generally lower than measurements from EPMA, with the exclusion of Cl, F, Si, and B. Overall, the two methods proved comparable and complementary. From EPMA, IC, and ICP-MS data, volatile elements were underrepresented compared to batched compositions, which suggested loss of these elements during melting. EPMA data was statistically analyzed to evaluate homogeneity within single bars and whole compositions for each of the seven glasses. Most of the variability within glass compositions occurred at the bar-to-bar level; however, no clear systematic trends were observed. Based on these analyses, when using these glasses as reference material, it is recommended that the overall mean and variance of each composition be used for performing instrument calibrations and analytical corrections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Progress Report for a 44-month Aging Study on Nitroplasticizer (NP) Stability - Summary of DFT and FTIR Results

In the past few years, a 44-month long aging experiment was conducted under various aging conditions. The properties of aged nitroplasticizer (NP) samples were analyzed using Fourier transform infrared spectroscopy, Karl Fischer (KF) titration, thermogravimetric analysis (TGA), liquid chromatography tandem quadrupole time of flight mass spectrometry (LC/QTOF), and ion chromatography (IC). In this progress report, some FTIR results are documented and discussed. On the theoretical front, density functional theory (DFT) calculations were carried out. Some DFT results are discussed as well.

36 MATERIALS SCIENCE↗

Analysis of Defense Waste Processing Facility (DWPF) Condensate Samples and Evaluation of the Glycolate Destruction Process during Nitric-Glycolic flowsheet Transition

Glycolate concentrations were measured by the Savannah River National Laboratory (SRNL) in Slurry Mix Evaporator Condensate Tank (SMECT) and Recycle Collection Tank (RCT) samples retrieved after implementation of the Nitric-Glycolic Acid flowsheet at the Defense Waste Processing Facility (DWPF). No glycolate has been detected in any sample using Ion Chromatography (IC) with a detection limit of 8 mg/L, and no glycolate has been detected using either IC or Proton Nuclear Magnetic Resonance Spectroscopy ( 1 HNMR) after a permanganate strike was performed in the RCT.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗