Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ion Mobility-Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Direct observation of C 60 - nano-ion gas phase ozonation via ion mobility-mass spectrometry

Improved methods to probe the reactivity of nano-ions, such as C 60 -, would find utility in nanochemistry, combustion chemistry, and in generally understanding the behavior of matter at the nanometer scale. Here, we demonstrate that ion mobility-mass spectrometry (IM-MS) with a low-field differential mobility analyzer can be used to probe nano-ion reaction kinetics. We used the developed IM-MS approach to examine the gas phase reactivity of C 60 - ions with ozone at atmospheric pressure. Experimental results show that ozonation of C 60 - mainly leads to the formation of C 60 O n -. The controlled reaction time within the ion mobility instrument enables calculation of ozonation reaction rates and assuming oxygen atoms are added sequentially, we find that the reaction rate between C 60 - and O 3 is near the collision controlled limit. We propose an exponentially decaying reaction rate coefficient expression to describe ozonation leading to the addition of >20 oxygen atoms. At high ozone concentrations, CO or CO 2 loss from C 60 O n - is additionally observed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fundamental Studies on Poly(2-oxazoline) Side Chain Isomers Using Tandem Mass Spectrometry and Ion Mobility-Mass Spectrometry

When polymer mixtures become increasingly complex, the conventional analysis techniques become insufficient for complete characterization. Mass spectrometric techniques can satisfy this increasing demand for detailed sample characterization. Even though isobaric polymers are indistinguishable using simple mass spectrometry (MS) analyses, more advanced techniques such as tandem MS (MS/MS) or ion mobility (IM) can be used. Here, we report proof of concept for characterizing isomeric polymers, namely poly(2-n-propyl-2-oxazoline) (Pn-PrOx) and poly(2-isopropyl-2-oxazoline) (Pi-PrOx), using MS/MS and IM-MS. Pi-PrOx ions lose in intensity at higher accelerating voltages than Pn-PrOx ions during collision-induced dissociation (CID) MS/MS experiments. A Pn/i-PrOx mixture could also be titrated using survival yield calculations of either precursor ions or cation ejection species. IM-MS yielded shape differences in the degree of polymerization (DP) regions showing the structural rearrangements. Combined MS techniques are thus able to identify and deconvolute the molar mass distributions of the two isomers in a mixture. Finally, the MS/MS and IM-MS behaviors are compared for interpretation. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Topological Characterization of Coordination-Driven Self-assembly Complexes: Applications of Ion Mobility-Mass Spectrometry

Coordination-driven self-assembly (CDSA) is increasingly used to synthesize coordination complexes containing metal-centered electron acceptors and typically nitrogen-containing electron donors. Characterization of the structures obtained from CDSA via crystallographic or spectroscopic means is limited due to difficulties in forming single crystals for X-ray studies and overlapping precursor and product signals in NMR. Here, we employ ion mobility-mass spectrometry (IM-MS), which provides a direct measure of size and shape of the CDSA complexes, to study the intact reaction products of a rhomboid-shaped complex. This approach negates the need for product isolation and crystallization and allows for tracking of the product distribution as a function of time. A potential challenge of IM-MS is that the size/shape of the observed CDSA complexes can vary with internal energy; however, we show that proper tuning of the instrument reduces the effects of collisional activation thereby allowing for retention of ion conformations that reflect solution-phase ion structures. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards Resolving the Spatial Metabolome with Unambiguous Molecular Annotations in Complex Biological Systems by Coupling Mass Spectrometry Imaging with Structures for Lossless Ion Manipulations

We demonstrate the coupling of liquid extraction surface analysis (LESA) to structures for lossless ion manipulations in conjunction with serpentine ultralong path with extending routing (SLIM SUPER) ion mobility-mass spectrometry (IM-MS) for the unambiguous annotation of important isomeric glycoforms in carbon-fixing communities. A major bottleneck of current mass spectrometry imaging (MSI) methods is their inability to accurately and confidently delineate amongst isomers within a single probing area. Our methodology provides gains in both sensitivity and IM resolution, while simultaneously gaining insight on the spatial distribution of these biological isomers in a mixed organism composed of moss, cyanobacteria and fungus. We envision this methodology will be broadly applicable to other mass spectrometry imaging modalities and invaluable in multiplexed, untargeted, analyses of a single probing location.

Nagy, Gabe↗

Mass spectrometry structural analysis of intrinsically disordered phosphoproteins

Phosphorylation is a ubiquitous protein modification that is known to play important roles in many biological phenomena including cell signaling, the opening and closing of membrane protein channels, and even triggering of amyloid protein aggregation. Despite the effects phosphorylation has on protein function, the impact phosphorylation has on the structure of proteins is not well understood. Here, to determine how phosphorylation affects the structure of proteins, top-down mass spectrometry (TD-MS) and ion mobility-mass spectrometry (IM-MS) were performed on various phosphorylated proteins and their dephosphorylated proteoforms. TD-MS with collision- and electron-based fragmentation techniques was utilized to locate phosphorylation sites on the intrinsically disordered amyloid proteins β-casein and α-synuclein. TD-MS also provided evidence that alkaline phosphatase dephosphorylates β-casein from the N-terminus to the C-terminus. Furthermore, IM-MS of common phosphorylated proteins such as β-casein, α-casein, ovalbumin, and phosvitin indicates that phosphorylation promotes compaction of protein structure in denaturing as well as native conditions. Increases in abundance of more compact conformers are also observed when the disease related amyloid protein α-synuclein is phosphorylated at serine 129. We interpret the increased abundance of more compact conformers when proteins are phosphorylated as evidence that salt bridges form between negatively charged phosphates and positively charged residues, which alters protein structure. Salt bridge formation due to phosphorylation could be a mechanism for regulating protein function and be responsible for many of the phenomena observed in nature.

Amyloid proteins↗

Discovery of a Ferromagnetic Nickel Chalcogenide Nanocluster Ni 3 S 3 H(PEt 3 ) 5

Atomically precise ligated nanoclusters (NC) are promising cluster-based materials with novel molecular architectures and tunable magnetic properties. Herein, the synthesis and characterization of a nickel sulfide NC Ni 3 S 3 H(PEt 3 ) 5 (PEt 3 = triethylphosphine) with distinct magnetic properties are reported. Magnetization measurements reveal its magnetic moment of 1.5 µ B in the solid phase, consistent with the existence of one unpaired electron predicted by density functional theory (DFT) calculations. Additionally, experimental measurements indicate the presence of ferromagnetic ordering within each Ni 3 S 3 H(PEt 3 ) 5 NC and strong coercivity at temperatures below 20 K. Ion mobility-mass spectrometry is employed in conjunction with DFT calculations and collision cross-section simulations to investigate the structure of the isolated Ni 3 S 3 H(PEt 3 ) 5 . Theoretical studies show that [Ni 3 S 3 H(PEt 3 ) 5 ] + has a planar Ni 3 S 3 core where three Ni atoms are arranged in a triangle with three bridging S atoms residing in the same plane. This structure is preserved in both solution and solid phases, which is confirmed by spectroscopic studies of Ni 3 S 3 H(PEt 3 ) 5 . Additionally, DFT calculations indicate that all spins at the Ni sites are aligned parallel, confirming the presence of ferromagnetic coupling. Overall, this study provides key insights into the structure and magnetic properties of Ni 3 S 3 H(PEt 3 ) 5 , which will facilitate the design of new NC-based magnetic materials.

Nickel sulfide nanocluster↗

Improving Signal to Noise Ratios in Ion Mobility Spectrometry and Structures for Lossless Ion Manipulations (SLIM) using a High Dynamic Range Analog-to-Digital Converter

Signal digitization is a commonly overlooked part of ion mobility-mass spectrometry (IMS-MS) workflows, yet it is a significant contributor for determining signal-to-noise ratios and MS resolution. Here we report on the integration of a 2 GS/s, 14-bit ADC with a structures for lossless ion manipulations (SLIM)-IMS-MS and compare the performance to a commonly used 8-bit ADC. The 14-bit ADC provided an effective reduction in digitized noise by factor of ~6, owing largely to the use of smaller bit sizes. The low baseline allowed the threshold voltage levels to be set very close to the MCP baseline voltage, allowing for as much signal to be acquired as possible without causing overloading or excessive digitization of MCP baseline noise. Analyses of Agilent tuning mixture ions and a complex mixture of heavy labeled phosphopeptides showed that the 14-bit ADC (compared to the 8-bit ADC) provided a modest signal-to-noise increase (~1.5 to 2-fold) for high intensity ions, such as the Agilent tuning mixture ions and the 2+ and 3+ charge states of many phosphopeptide constituents. However, signal enhancements were as much as 10-fold for low intensity ions, and the 14-bit ADC enabled discernable signal intensities otherwise lost using an 8-bit digitizer. Additionally, the 14-bit ADC required ~14-fold fewer mass spectra to be averaged to produce a mass spectrum with similar S/N as the 8-bit ADC under identical conditions, potentially providing an order of magnitude higher measurement throughput. The high resolution, low baseline, and fast speed of the new 14-bit ADC enables high performance digitization of MS, IMS-MS, and SLIM-IMS-MS spectra, and allows a much fuller picture of analyte profiles in complex mixtures to be acquired.

data acquisition, digitization, ion mobility spect↗

Separation of ß-Amyloid Tryptic Peptide Species with Isomerized and Racemized L-Aspartic Residues with Ion Mobility in Structures for Lossless Ion Manipulations

Accumulation of ß-amyloid (Aß) is one of the hallmarks of Alzheimer’s disease. The deposition of ß-amyloid plaques is likely to start years in advance of manifestation of clinical symptoms, although the exact timing is unknown. Over the years, Aß peptides undergo post-translational modifications and stereoisomerization. Analysis of stereoisomers is particularly challenging due to their identical elemental composition and similar physicochemical properties. Herein we have utilized our recently developed structures for lossless ion manipulations ion mobility-mass spectrometry platform (SLIM IM-MS), in conjunction with SLIM serpentine ultralong path with extended routing (SUPER), to baseline resolve four distinct sets of Aß17-28 tryptic peptide epimers on a rapid (~1 second) timescale. We discovered that sodium adduct ions, [M+H+Na]2+, allowed baseline IM resolution for all Aß epimer sets assessed, while such baseline separations were unachievable for their [M+2H]2+ doubly protonated ions.

Nagy, Gavril↗

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations

Ion mobility-mass spectrometry (IMS-MS) is increasingly used to analyze complex samples and provide structural information of unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. In this work, we evaluated a cyclable and variable-pathlength multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators and a path length of ~88 meters (~11 meters per level). Our new multilevel SLIM can also be operated in an ‘ion cycling’ mode where a set of return ion escalators transport ions from the eighth back to the first level, allowing even longer path lengths (and higher IMS resolution). The platform has been improved to enhance the ion transmission and IMS separation quality by reducing the spacing between SLIM boards as well as board thickness, reducing the ions’ escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated a better transmission for a set of phosphazene ions, especially for the low-mobility ions. The new multilevel SLIM achieved better resolving powers than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of singly-charged reverse sequence peptides (SDGRG 1+ , GRGDS 1+ ). We achieved 1100 resolving power using 88 meters of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels (i.e., 16 levels or 173.5 m). The multilevel SLIM was further evaluated to demonstrate the enhanced separation for a positively and negatively charged brain total lipid extract sample. Finally, the new multilevel SLIM enables much higher resolving powers for a wide range of ion mobilities, improved transmission for low-mobility ions, and the ability to perform even higher resolving power for ions of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Gas-Phase Ion Mobility Coefficients Using Voltage Sweep Multiplexing

In a standard single averaged, drift tube ion mobility spectrometry (IMS) experiment, typically less than 1% of the ions are utilized, with the rest of the ions neutralizing on a closed ion gate or ion optic element. Though some efforts at lower pressures (e.g., 4 Torr) have been made to address this issue by concentrating ions prior to release into a drift cell, the ion current reaching the detector during an IMS experiment is often diminished due to this lower duty cycle. Additionally, when considering the temporal nature of the drift tube IMS experiment and the trajectory of IMS towards higher resolution separations and lower duty cycles, increased detector sampling rates are another factor also which further necessitates new modes of conducting the IMS experiment. Placing this trend in context with ion mobility-mass spectrometry instruments (IM-MS), there are numerous types of mass spectrometers that are simply incompatible with the single averaged ion mobility spectrometry experiments due to timing incompatibilities (i.e., ion traps are an order of magnitude slower than the IMS experiment). However, by utilizing a dual gate ion mobility spectrometer for ion multiplexing, ion utilization efficiency can be significantly increased while creating a measurement signal that can be recorded at low sampling rates. In this work, we present the fundamental theory and first results from proof-of-concept measurements using a new type of ion multiplexing that relies on changing the electric field within the drift cell during the course of an experiment while simultaneously opening the ion gates at a constant frequency. For brevity, this mode is termed voltage sweep multiplexing (VSM). Key variables for this type of experiment are discussed and verified with measurements from traditional signal averaged experiments. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural Changes in Metal Chalcogenide Nanoclusters Associated with Single Heteroatom Incorporation

Atomically precise nanoclusters (NCs) are promising building blocks for designing materials and interfaces with unique properties. By incorporating heteroatoms into the core, the electronic and magnetic properties of NCs can be precisely tuned. To accurately predict these properties, density functional theory (DFT) is often employed, making the rigorous benchmarking of DFT results particularly important. In this study, we present a benchmarking approach based on metal chalcogenide NCs as a model system. We synthesized a series of bimetallic, iron-cobalt chalcogenide NCs [Co 6-x Fe x S 8 (PEt 3 ) 6 ] + (x = 0-6) (PEt = triethyl phosphine) and investigated the effect of heteroatoms in the octahedral metal chalcogenide core on their size and electronic properties. Using ion mobility-mass spectrometry (IM-MS), we observed a gradual increase in the collision cross section (CCS) with an increase in the number of Fe atoms in the core. DFT calculations combined with trajectory method CCS simulations successfully reproduced this trend, revealing that the increase in cluster size is primarily due to changes in metal-ligand bond lengths, while the electronic properties of the core remain largely unchanged. Moreover, this method allowed us to exclude certain multiplicity states of the NCs, as their CCS values were significantly different from those predicted for the lowest-energy structures. Here, this study demonstrates that gas-phase IM-MS is a powerful technique for detecting subtle size differences in atomically precise NCs, which are often challenging to observe using conventional NC characterization methods. Accurate CCS measurements are established as a benchmark for comparison with theoretical calculations. The excellent correspondence between experimental data and theoretical predictions establishes a robust foundation for investigating structural changes of transition metal NCs of interest to a broad range of applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LipidOz enables automated elucidation of lipid carbon–carbon double bond positions from ozone-induced dissociation mass spectrometry data

Lipids play essential roles in many biological processes and disease pathology, but unambiguous identification of lipids is complicated by the presence of multiple isomeric species differing by fatty acyl chain length, stereospecifically numbered (sn) position, and position/stereochemistry of double bonds. Conventional liquid chromatography-mass spectrometry (LC-MS/MS) analyses enable the determination of fatty acyl chain lengths (and in some cases sn position) and number of double bonds, but not carbon-carbon double bond positions. Ozone-induced dissociation (OzID) is a gas-phase oxidation reaction that produces characteristic fragments from lipids containing double bonds. OzID can be incorporated into ion mobility spectrometry (IMS)-MS instruments for the structural characterization of lipids, including additional isomer separation and confident assignment of double bond positions. The complexity and repetitive nature of OzID data analysis and lack of software tool support have limited the application of OzID for routine lipidomics studies. Here, we present an open-source Python tool, LipidOz, for the automated determination of lipid double bond positions from OzID-IMS-MS data, which employs a combination of traditional automation and deep learning approaches. Our results demonstrate the ability of LipidOz to robustly assign double bond positions for lipid standard mixtures and complex lipid extracts, enabling practical application of OzID for future lipidomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine Learning Framework for Conotoxin Class and Molecular Target Prediction

Conotoxins are small and highly potent neurotoxic peptides derived from the venom of marine cone snails which have captured the interest of the scientific community due to their pharmacological potential. These toxins display significant sequence and structure diversity, which results in a wide range of specificities for several different ion channels and receptors. Despite the recognized importance of these compounds, our ability to determine their binding targets and toxicities remains a significant challenge. Predicting the target receptors of conotoxins, based solely on their amino acid sequence, remains a challenge due to the intricate relationships between structure, function, target specificity, and the significant conformational heterogeneity observed in conotoxins with the same primary sequence. We have previously demonstrated that the inclusion of post-translational modifications, collisional cross sections values, and other structural features, when added to the standard primary sequence features, improves the prediction accuracy of conotoxins against non-toxic and other toxic peptides across varied datasets and several different commonly used machine learning classifiers. Here, we present the effects of these features on conotoxin class and molecular target predictions, in particular, predicting conotoxins that bind to nicotinic acetylcholine receptors (nAChRs). We also demonstrate the use of the Synthetic Minority Oversampling Technique (SMOTE)-Tomek in balancing the datasets while simultaneously making the different classes more distinct by reducing the number of ambiguous samples which nearly overlap between the classes. In predicting the alpha, mu, and omega conotoxin classes, the SMOTE-Tomek PCA PLR model, using the combination of the SS and P feature sets establishes the best performance with an overall accuracy (OA) of 95.95%, with an average accuracy (AA) of 93.04%, and an f1 score of 0.959. Using this model, we obtained sensitivities of 98.98%, 89.66%, and 90.48% when predicting alpha, mu, and omega conotoxin classes, respectively. Similarly, in predicting conotoxins that bind to nAChRs, the SMOTE-Tomek PCA SVM model, which used the collisional cross sections (CCSs) and the P feature sets, demonstrated the highest performance with 91.3% OA, 91.32% AA, and an f1 score of 0.9131. The sensitivity when predicting conotoxins that bind to nAChRs is 91.46% with a 91.18% sensitivity when predicting conotoxins that do not bind to nAChRs.

59 BASIC BIOLOGICAL SCIENCES↗

High-resolution ion mobility based on traveling wave structures for lossless ion manipulation resolves hidden lipid features

Abstract High-resolution ion mobility (resolving power > 200) coupled with mass spectrometry (MS) is a powerful analytical tool for resolving isobars and isomers in complex samples. High-resolution ion mobility is capable of discerning additional structurally distinct features, which are not observed with conventional resolving power ion mobility (IM, resolving power ~ 50) techniques such as traveling wave IM and drift tube ion mobility (DTIM). DTIM in particular is considered to be the “gold standard” IM technique since collision cross section (CCS) values are directly obtained through a first-principles relationship, whereas traveling wave IM techniques require an additional calibration strategy to determine accurate CCS values. In this study, we aim to evaluate the separation capabilities of a traveling wave ion mobility structures for lossless ion manipulation platform integrated with mass spectrometry analysis (SLIM IM-MS) for both lipid isomer standards and complex lipid samples. A cross-platform investigation of seven subclass-specific lipid extracts examined by both DTIM-MS and SLIM IM-MS showed additional features were observed for all lipid extracts when examined under high resolving power IM conditions, with the number of CCS-aligned features that resolve into additional peaks from DTIM-MS to SLIM IM-MS analysis varying between 5 and 50%, depending on the specific lipid sub-class investigated. Lipid CCS values are obtained from SLIM IM ( TW(SLIM) CCS) through a two-step calibration procedure to align these measurements to within 2% average bias to reference values obtained via DTIM ( DT CCS). A total of 225 lipid features from seven lipid extracts are subsequently identified in the high resolving power IM analysis by a combination of accurate mass-to-charge, CCS, retention time, and linear mobility-mass correlations to curate a high-resolution IM lipid structural atlas. These results emphasize the high isomeric complexity present in lipidomic samples and underscore the need for multiple analytical stages of separation operated at high resolution. Graphical abstract

Reardon, Allison R. (ORCID:0000000165830134)↗

Validation of Calibration Parameters for Trapped Ion Mobility Spectrometry

Using contemporary theory for ion mobility spectrometry (IMS), gas-phase ion mobilities within a trapped ion mobility-mass spectrometer (TIMS) are not easily deduced using first principle equations due to non-linear pressure changes and consequently variations in E/N. It is for this reason that prior literature values have traditionally been used for TIMS calibration. Additionally, given that verified mobility standards currently do not exist and the that the exact conditions used to measure reported literature values may not always represent the environment within the TIMS, a direct approach to validating the behavior of the TIMS system is warranted. A calibration procedure is presented where an ambient pressure, ambient temperature, two-gate, printed circuit board drift-tube IMS (PCBIMS) is coupled to the front of a TIMS allowing reduced mobilities to be directly measured on the same instrument as the TIMS. These measured mobilities were used to evaluate the TIMS calibration procedure which correlates reduced mobility and TIMS elution voltages with literature values. When using the measured PCBIMS-reduced mobilities of tetraalkyl ammonium salts and tune mix for TIMS calibration of the alkyltrimethyl ammonium salts, the percent error is less than 1% as compared with using the reported literature K{sub 0} values where the percent error approaches 5%. This method provides a way to obtain accurate reference mobilities for ion mobility techniques that require a calibration step (i.e., TIMS and TWAVE). .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗