Effect of Ion Concentration on the Formation of Bicontinuous Microemulsions in Partially Charged Ternary Polymer Blends
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Not provided.
This research examines theoretically the ion concentration polarization, ion fluxes, and electrostatic fields near an ion exchange patch in the wall of an electrified fluidic channel. These phenomena are important in related microfluidic ion-preconcentration systems. Under an electric field, counterions enter the ion-exchange patch at one side and leave at the other, with salt depletion occurring near the entrance and accumulation near the exit. Furthermore, the high patch conductivity and the concentration profiles lead to local electric field perturbations that may facilitate preconcentration. This study includes analytical expressions of ion concentrations and electrochemical potentials at small to moderate electric fields, as well as numerical simulations. Additionally, a simple matrix of polynomial coefficients (obtained via fitting of numerical data) enables analytical calculation of the 2-dimensional concentration profiles at all electric fields within the range investigated in the numerical simulations. This is possible because a single dimensionless parameter controls this problem.
A commercially available electron cyclotron resonance (ECR) plasma source (GenII Plasma Source, tectra GmbH) is widely used for surface processing. This plasma source is compatible with ultrahigh vacuum systems, and its working pressure is relatively low, around 10 –6 –10 –4 Torr even without differential pumping. Here, we report ion flux concentration ratios for each ion species in an ion beam from this source, as measured by a mass/energy analyzer that is a combination of a quadrupole mass spectrometer, an electrostatic energy analyzer, and focusing ion optics. In this study, the examined beams were those arising from plasmas produced from feed gases of H 2 , D 2 , N 2 , O 2 , Ar, and dry air over a range of input power and working pressures. H 2 (D 2 ) plasmas are widely used for nuclear fusion applications and, hence, the ion concentration ratios of H + , H 2 + , and H 3 + reported here will be useful information for research that applies this plasma source to well-controlled plasma-material interaction studies. Ion energy distributions, stability of operation, and impurity concentrations were also assessed for each of the plasma species investigated.
The presence of fluoride anions in the synthesis gel leads to zeolite BEA with high hydrothermal stability. This longer lifetime is caused by a lower concentration of internal silanol defects that are sites of the initial framework hydrolysis eventually destroying the lattice structure. The lifetime of these zeolites was the higher the lower the concentration of framework bridging hydroxyl groups that form hydronium ions was. While lattice hydrolysis was initiated at defect sites in all cases, the role of defects became less important as the concentration of hydronium ions increased. At higher concentration of hydrated hydronium ions, the presence of water associated with the hydrated hydronium ions limits the useful lifetime of zeolite catalysts in water. For such materials, the selective hydrophobization of the external surface extends the lifetime. Acknowledgments: S.P. and M.A.D. acknowledge support by the Materials Synthesis and Simulation Across Scales (MS3 Initiative) conducted under Laboratory Directed Research & Development Program at PNNL. H.S. and H.W. were supported by the Chemical Transformation Initiative (CTI) conducted under Laboratory Directed Research & Development Program at PNNL. J.A.L. was supported by the US Department of Energy, Office of Science, Office of Basic Energy Sciences.
A membrane-free photoelectrochemical device is able to partially desalinate water.
Precipitation was collected from three different areas on the Savannah River Site during 2021. The precipitation was analyzed for concentrations of 29 different ions and compared with data on factors such as wind speed, wind direction, rain drop sizes, and more. The 2021 ion concentrations were also compared to the ion concentrations from previous years at the site as well as from Santee National Wildlife Refuge which is nearby. The historical ion concentrations data was gathered from the National Atmospheric Deposition Program. Scatter plots and correlation coefficients were used to identify what factors may have the greatest impact on ion concentration in rainwater. The data generally followed the same trends with a few notable outliers. There initially seemed to be a strong correlation between the mean diameter and some ion concentrations as both increased in July. However, ion concentrations in different areas were related to different wind directions, thus spatial variability must be considered. These factors, spatial variability of atmospheric particles and wind direction, impact concentrations of ions in precipitation.
Single-ion-conducting polymers are ideal electrolytes for rechargeable lithium batteries as they eliminate salt concentration gradients and concomitant concentration overpotentials during battery cycling. Here in this paper, we study the ionic conductivity and morphology of poly(ethylene oxide)-b-poly(styrenesulfonyllithium(trifluoromethylsulfonyl)imide) (PEO-b-PSLiTFSI) block copolymers with no added salt using ac impedance spectroscopy and small-angle X-ray scattering. The PEO molecular weight was held fixed at 5.0 kg mol -1 , and that of PSLiTFSI was varied from 2.0 to 7.5 kg mol -1 . The lithium ion concentration and block copolymer composition are intimately coupled in this system. At low temperatures, copolymers with PSLiTFSI block molecular weights ≤4.0 kg mol -1 exhibited microphase separation with crystalline PEO-rich microphases and lithium ions trapped in the form of ionic clusters in the glassy PSLiTFSI-rich microphases. At temperatures above the melting temperature of the PEO microphase, the lithium ions were released from the clusters, and a homogeneous disordered morphology was obtained. The ionic conductivity increased abruptly by several orders of magnitude at this transition. Block copolymers with PSLiTFSI block molecular weights ≥5.4 kg mol -1 were disordered at all temperatures, and the ionic conductivity was a smooth function of temperature. The transference numbers of these copolymers varied from 0.87 to 0.99. The relationship between ion transport and molecular structure in single-ion-conducting block copolymer electrolytes is qualitatively different from the well-studied case of block copolymers with added salt.
Understanding ion behaviors in functionalized nanopores is essential to deciphering reactions in both natural and engineered systems, such as sediments, biological ion channels, and membranes. While many efforts have shown the modified ion behaviors in the functionalized nanopores, a direct measurement and analysis to show how chemical functional groups affect ion concentrations in nanopores are critically needed. In this work, we present a plasmonic nanosensor that can measure the local concentrations of protons, anions (phosphate, nitrate, sulfate, and arsenate), and cations (mercury, lead, and copper) in functionalized nanopores, and we compare their concentrations in nanopores with the corresponding bulk concentrations. Notably, chemical functional groups induced ion concentrations differently in nanopores. In pristine nanopores and methyl- and phenyl-functionalized nanopores, we discovered an unexpected concurrence of an enhanced anion concentration and a suppressed cation concentration. In addition, the nanopore pH is dependent on bulk solution compositions and can be lower by 2.5 units, even when the bulk solution is well-buffered. In contrast, for hydrophilic (amine, thiol, and carboxyl) nanopores, pH depended on the p K a of the functional groups, and the heavy metal concentrations depended on chemical interactions with the functional groups. Our findings provide a better understanding of water chemistry in nanopores and can help precisely control ions in nanopores to benefit the design of membrane-based desalination techniques, CO 2 storage, and porous catalysts.
Chloride ion, the majority salt in nature, is ~52% faster than sodium ion (D Na+ = 1.33, D Cl- = 2.03[10 -9 m 2 s -1 ]). Yet, current electrochemical desalination technologies (e.g. electrodialysis) rely on bipolar ion conduction, removing one pair of the cation and the anion simultaneously. Here, we demonstrate that novel ion concentration polarization desalination can enhance salt removal under a given current by implementing unipolar ion conduction: conducting only cations (or anions) with the unipolar ion exchange membrane stack. Combining theoretical analysis, experiment, and numerical modeling, we elucidate that this enhanced salt removal can shift current utilization (ratio between desalted ions and ions conducted through electrodes) and corresponding energy efficiency by the factor ~(D - –D + )/(D - + D + ). Specifically for desalting NaCl, this enhancement of unipolar cation conduction saves power consumption by ~50% in overlimiting regime, compared with conventional electrodialysis. Recognizing and utilizing differences between unipolar and bipolar ion conductions have significant implications not only on electromembrane desalination, but also energy harvesting applications (e.g. reverse electrodialysis).
Here, we present a quantitative method to measure the concentration and diffusivity of Li ion in a solid-state electrolyte with nanoscale depth resolution. We designed a standard sample with different depths of trenches and used time-of-flight secondary ion mass spectroscopy, inductively coupled plasma optical emission spectroscopy, three-dimensional (3D) optical microscopy, and electrochemical strain microscopy to obtain effective Li-ion concentration and the corresponding diffusivity as a function of depth. As a result, we verified the dependence of electromechanical strain induced by ionic oscillation on mobile-ion concentration. We also showed the diffusivity change as a function of effective concentration and discussed the difference in diffusivity near the surface and inside the bulk. Our method can be widely used for electromechanical strain in various ionic conductors, rendering our technique universal for quantitative analysis of ionic dynamics at a multiscale.
Ion migration is one of the prime reasons for the rapid degradation of metal halide perovskite solar cells (PSCs), and we report on a method for quantifying mobile ion concentration (No) using a transient dark current measurement. We perform both ex-situ and in-situ measurements on PSCs and study the evolution of No in films and devices under a range of temperatures. We also study the effect of device architecture, top electrode chemistry, and metal halide perovskite composition and dimensionality on No. Two-dimensional perovskites are shown to reduce the ion concentration along with inert C electrodes that do not react with halides by ~99% while also improving mechanical reliability by ~250%. We believe this work can provide design guidelines for the development of stable PSCs through the lens of minimizing mobile ions and their evolution over time under operational conditions.
The ability to charge a Li-ion battery at high charging rates is critical for electric vehicle adoption; however, further study of ion transport is required to develop electrolytes suitable for fast charge. Fourier transform infrared spectroscopy (FTIR) used with attenuated total reflection (ATR) enables operando measurements of liquid electrolytes. This research focused on solvation shifting of solvent infrared absorption bands in the presence of lithium ions. Lithium-shifted infrared absorption bands and non-shifted bands of ethyl methyl carbonate (EMC) and ethylene carbonate (EC) were compared to infer ion concentration changes during cycling. Lithium concentrations were calibrated using EC/EMC/LiPF 6 electrolytes with known lithium concentrations. A Li-ion half-cell with a graphite anode and EC/EMC/LiPF 6 electrolyte was observed with FTIR/ATR. The results showed that the magnitude of lithium concentration changes increased with increasing C-rate. During a galvanostatic intermittent titration technique (GITT) test, changes in lithium concentration could be observed. During intercalation, a lithium depletion occurred when a negative current was applied, and a lithium surplus occurred during deintercalation when a positive current was applied. The capability of observing lithium concentration has significant implications for the utility of operando studies and the potential to link lithium movement to battery performance.
A method of selective detection of a concentration of a metal ion species in a subject is provided in which a biofluid sample is obtained from the subject. The biofluid sample is exposed to a functionalized porous aromatic polymer. The polymer selectively captures and concentrates the metal ion species from the biofluid. Subsequently, the biofluid is washed from the polymer. The polymer is then exposed to a solution comprising a colorimetric indicator that extracts the metal ion species from the washed polymer thereby changing a color of the solution as a function of an amount of the metal ion species in the polymer. The concentration of the metal ion species in the subject is then spectroscopically determined from the color of the solution.
Electrorefining of spent metallic nuclear fuel in high temperature molten salt systems is a core technology in pyroprocessing, which in turn plays a critical role in the development of advanced fuel cycle technologies. In electrorefining, spent nuclear fuel is treated electrochemically in order to effect separations between uranium, noble metals, and active metals, which include the transuranics. The accumulation of active metals in a lithium chloride-potassium chloride (LiCl-KCl) eutectic molten salt electrolyte occurs at the expense of the UCl3-oxidant concentration in the electrolyte, which must be periodically replenished. Our interests lie with the accumulation of active metals in the molten salt electrolyte. The real-time monitoring of actinide concentrations in the molten salt electrolyte is highly desirable for controlling electrochemical operations and assuring materials control and accountancy. However, real-time monitoring is not possible with current methods for sampling and chemical analysis. A new solid-state electrochemical sensor is being developed for real-time monitoring of actinide ion concentrations in a molten salt electrorefiner. The ultimate function of the sensor is to monitor plutonium concentrations during electrorefining operations, but in this work gadolinium was employed as a surrogate material for plutonium. In a parametric study, polycrystalline sodium beta double-prime alumina (Na-ß?-alumina) discs and tubes were subject to vapor-phase exchange with gadolinium ions (Gd3+) using a gadolinium chloride salt (GdCl3) as a precursor to produce gadolinium beta double-prime alumina (Gd-ß?-alumina) samples. Electrochemical impedance spectroscopy and microstructural analysis were performed on the ion-exchanged discs to determine the relationship between ion exchange and Gd3+ ion conductivity. The ion-exchanged tubes were configured as potentiometric sensors in order to monitor real-time Gd3+ ion concentrations in mixtures of gadolinium chloride (GdCl3) in LiCl-KCl eutectic molten salts through measurement of the potential difference between a reference and working electrode.
We have measured the fraction of holmium ions that relax nonradiatively to the ground level as a result of interaction at a metastable level in optical fibres with a silica-based core doped with holmium ions to 2 x 10{sup 19} - 2 x 10{sup 20} cm{sup -3}. The percentage of such ions has been shown to depend on the absolute active-ion concentration. The fibres have been used to make a number of 2.05-{mu}m lasers, and their slope efficiency has been measured. The laser efficiency decreases with increasing holmium concentration in the fibres (lasers)
The lasing dynamics of fibre lasers with a core based on quartz glass doped with holmium ions to concentrations in the range of 10{sup 19}-10{sup 20} cm{sup -3} is investigated. It is shown that fibre lasers with a high concentration of active holmium ions generate pulses, but a decrease in the holmium concentration changes the lasing from pulsed to cw regime. At the same time, a decrease in the active-ion concentration and the corresponding increase in the fibre length in the cavity reduce the lasing efficiency. (lasers)
Disclosed herein are systems and methods that relate to use of ultramicroelectrodes (UME) in measurement of ion concentration in presence of one or more organic compound(s).