Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ion-trap”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Simultaneous quantification of poly-dispersed anionic, amphoteric and nonionic surfactants in simulated wastewater samples using C18 high-performance liquid chromatography-quadrupole ion-trap mass spectrometry

This paper describes the development of a guantitative method for direct and simultaneous determination of three frequently encountered surfactants, amphoteric (cocoamphoacetate, CAA), anionic (sodium laureth sulfate, SLES), and nonionic (alcohol ethoxylate, AE) using a reversed-phase C18 HPLC coupled with an ESI ion-trap mass spectrometer (MS). Chemical composition, ionization characteristics and fragmentation pathways of the surfactants are presented. Positive ESI was effective for all three surfactants in agueous methanol buffered with ammonium acetate. The method enables rapid determinations in small sample volumes containing inorganic salts (up to 3.5 g L(-1)) and multiple classes of surfactants with high specificity by applying surfactant specific tandem mass spectrometric strategies. It has dynamic linear ranges of 2-60, 1.5-40, 0.8-56 mg L(-1) with R2 egual or greater than 0.999, 0.98 and 0.999 (10 microL injection) for CAA, SLES, and AE, respectively.

Chromatography, High Pressure Liquid/methods↗

SIREN: Scaling Ion-Traps by REquiring iNnovative Heterogenous Integration

The SIREN (Scaling Ion Traps by Requiring iNnovative heterogenous integration) project explores the feasibility of heterogeneous integration (HI) as a transformative approach to scaling ion traps, a critical technology for advancing quantum computers and atomic clocks. Traditional ion trap architectures face significant challenges in scalability due to limitations in optical access, fabrication techniques, and material constraints. SIREN addresses these challenges by leveraging HI, which combines different materials and fabrication processes to create more complex and efficient ion trap structures. HI integrated structures can be manufactured without compromising the process to maintain compatibility to ion traps. This project focuses on integrating a separately fabricated waveguide with a fully functional ion trap. The respective alignment between the pieces needs to be accurate to less than 2 µm to ensure that the light from the waveguide can overlap with the trapping region. The fine alignment must also be maintained through an ultra-high vacuum bake, a critical step in preparing an ion trap experiment. The project's outcomes suggest that heterogeneous integration is a promising pathway for overcoming current scalability barriers, paving the way for the next generation of quantum technologies. SIREN's findings contribute significantly to the field, offering a scalable solution that could accelerate the development of practical quantum computers and highly accurate atomic clocks.

42 ENGINEERING↗

In-Situ Studies of the Lunar Water Cycle Using a CLPS-Delivered Ion-Trap Mass Spectrometer (PITMS)

Characterize the lunar exosphere from the surface after descent and landing, and throughout the lunar day, to understand the release and movement of volatile species. Leverage the PROSPECT program and develop the ITMS as a standalone mass spectrometer suitable for commercial lunar landers. PITMS will consist of a PROSPECT-derived ITMS sensor and front-end electronics, newly developed controller and power supply boards, and a GSFC wrapper. Lander-friendly: low resource (<2 kg, 4-8 W), simple interfaces, passive, landing site agnostic.

Cohen, Barbara A.↗

Supramolecular Control of Ionic Retention in Electrolyte-Gated Synaptic Transistors

Electrolyte-gated transistors with ion-trapping layers offer a promising platform for artificial synapses in neuromorphic computing, yet molecular mechanisms governing ionic retention remain poorly understood. Here, in this study, we present a supramolecular approach to modulate ion retention by incorporating a crown ether derivative-based polymer network as an ion-trapping layer on top of a semiconducting monolayer. We show that the balance between ion–host binding and ion–solvent interactions dictates the kinetics of ion capture and release, which in turn controls the memory characteristics of the device. By varying the solvent dielectric constant, we tune the ionic retention time from nearly permanent trapping to rapid relaxation. Intermediate solvent polarity enables programmable short- and long-term synaptic behaviors, including excitatory postsynaptic current, paired-pulse facilitation, and long-term potentiation and depression. These findings establish a direct link between supramolecular ion recognition and synaptic plasticity and provide a generalizable design strategy for ionic–electronic neuromorphic devices.

36 MATERIALS SCIENCE↗

Optimizing qubit control pulses for state preparation

In the burgeoning field of quantum computing, the precise design and optimization of quantum pulses are essential for enhancing qubit operation fidelity. This study focuses on refining the pulse engineering techniques for superconducting qubits, employing a detailed analysis of square and Gaussian pulse envelopes under various approximation schemes. We evaluated the effects of coherent errors induced by naive pulse designs. Furthermore, we identified the sources of these errors in the Hamiltonian model’s approximation level. We mitigated these errors through adjustments to the external driving frequency and pulse durations, thus implementing a pulse scheme with stroboscopic error reduction. Our results demonstrate that these refined pulse strategies improve performance and reduce coherent errors. Moreover, the techniques developed herein are applicable across different quantum architectures, such as ion-trap, atomic, and photonic systems.

Chirp modulation↗

Collection of fluorescence from an ion using trap-integrated photonics

Spontaneously emitted photons are entangled with the electronic and nuclear degrees of freedom of the emitting atom, so interference and measurement of these photons can entangle separate matter-based quantum systems as a resource for quantum information processing. Since confinement in a single-mode facilitates the photon interference needed for generating entanglement, the dipole emission patterns relevant in spontaneous emission present a mode-matching challenge. Current demonstrations rely on bulk photon-collection and manipulation optics that suffer from large component size and system-to-system variability—factors that impede scaling to the large numbers of entangled pairs needed for quantum information processing. To address these limitations, we demonstrate a collection method that enables passive phase stability, straightforward photonic manipulation, and intrinsic reproducibility. Specifically, we engineer a waveguide-integrated grating to couple photons emitted from a trapped ion into a single optical mode within a microfabricated ion-trap chip. Using the integrated collection optic, we characterize the collection efficiency, image the ion, and detect the ion’s quantum state. The integrated optic covers 2.18% of the solid angle and collects 1.97 ± 0.3% of the spontaneously emitted light incident on the grating for a total collection efficiency of 0.043% into a single-mode waveguide. This proof-of-principle demonstration lays the foundation for leveraging the inherent stability and reproducibility of integrated photonics to create, manipulate, and measure multipartite quantum states in arrays of quantum emitters.

Optical physics↗

Scalable Experimental Bounds for Entangled Quantum State Fidelities

Estimating the state preparation fidelity of highly entangled states on noisy intermediate-scale quantum (NISQ) devices is important for benchmarking and application considerations. Unfortunately, exact fidelity measurements quickly become prohibitively expensive, as they scale exponentially as O(3 N for N-qubit states, using full state tomography with measurements in all Pauli bases combinations. However, Somma et al.established that the complexity could be drastically reduced when looking at fidelity lower bounds for states that exhibit symmetries, such as Dicke states and GHZ states. These bounds must still be tight enough for larger states to provide reasonable estimations on NISQ devices. For the first time and more than 15 years after the theoretical introduction, we report meaningful lower bounds for the state preparation fidelity of all Dicke states up to N=10 and all GHZ states up to N=20 on Quantinuum H1 ion-trap systems using efficient implementations of recently proposed scalable circuits for these states. Our achieved lower bounds match or exceed previously reported exact fidelities on superconducting systems for much smaller states. Furthermore, we provide evidence that for large Dicke states |$D^{N}_{N/2}\rangle$, we may resort to a GHZ-based approximate state preparation to achieve better fidelity. This work provides a path forward to benchmarking entanglement as NISQ devices improve in size and quality.

97 MATHEMATICS AND COMPUTING↗

Quantum Advantage in Trading: A Game-Theoretic Approach

Quantum games, like quantum algorithms, exploit quantum entanglement to establish strong correlations between strategic player actions. This paper introduces quantum game-theoretic models applied to trading and demonstrates their implementation on an ion-trap quantum computer. The results showcase a quantum advantage, previously known only theoretically, realized as higher-paying market Nash equilibria. This advantage could help uncover alpha in trading strategies, defined as excess returns compared to established benchmarks. These findings suggest that quantum computing could significantly influence the development of financial strategies.

Khan, Faisal Shah [Taqtics LLC, USA, Rethinc. Labs↗

Integrated photonic structures for photon-mediated entanglement of trapped ions

Trapped atomic ions are natural candidates for quantum information processing and have the potential to realize or improve quantum computing, sensing, and networking. These applications often require the collection of individual photons emitted from ions into guided optical modes, in some cases for the production of entanglement between separated ions. Proof-of-principle demonstrations of such photon collection from trapped ions have been performed using high-numerical-aperture lenses or cavities and single-mode fibers, but integrated photonic elements in ion-trap structures offer advantages in scalability and manufacturability over traditional optics. In this paper we analyze structures monolithically fabricated with an ion trap for collecting ion-emitted photons, coupling them into waveguides, and manipulating them via interference. We calculate geometric limitations on collection efficiency for this scheme, simulate a single-layer grating that shows performance comparable to demonstrated free-space optics, and discuss practical fabrication and fidelity considerations. Based on this analysis, we conclude that integrated photonics can support scalable systems of trapped ions that can distribute quantum information via photon-mediated entanglement.

Knollmann, Felix W.↗

Lignin Sensor Based On Flash-Pyrolysis Mass Spectrometry

New lignin sensor takes only few minutes to measure lignin content of specimen of wood, pulp, paper, or similar material. Includes flash pyrolizer and ion-trap detector that acts as mass spectrometer. Apparatus measures amount of molecular fragments of lignin in pyrolysis products of samples. Helpful in controlling digestors in paper mills to maintain required lignin content, and also in bleaching plants, where good control of bleaching becomes possible if quick determination of lignin content made.

Kwack, Eug Y.↗

Transition probabilities for the 3s2 3p(2P0)-3s3p2(4P) intersystem lines of Si II

Intensity ratios of lines of the spin-changing 'intersystem' multiplet of S II (4P yields 2P0) at 234 nm have been used to determine electron densities and temperatures in a variety of astrophysical environments. However, the accuracy of these diagnostic calculations have been limited by uncertainties associated with the available atomic data. We report the first laboratory measurement, using an ion-trapping technique, of the radiative lifetimes of the three metastable levels of the 3s3p2 4P term of Si II. Our results are 104 +/- 16, 406 +/- 33, and 811 +/- 77 micro-s for lifetimes of the J = 1/2, 5/2, and 3/2 levels, respectively. A-values were derived from our lifetimes by use of measured branching fractions. Our A-values, which differ from calculated values by 30 percent or more, should give better agreement between modeled and observed Si II line ratios.

Calamai, Anthony G.↗

Elemental mass spectroscopy of remote surfaces from laser-induced plasmas

The elemental mass analysis of laser-produced ions from Al, Cu, Ge, Ag, and a lunar simulant target when irradiated by a 400-mJ, 8-ns, Nd: YAG laser at 1 x 10(exp 9) W/cm(exp 2), is reported. Ions traveled down a 11.1-m evacuated tube to an ion-trap 1-m time-of-flight (TOF) mass spectrometer where an elemental mass spectrum was recorded. The amount of target material removed per laser pulse and the ionization fraction were measured. The ion spatial distribution was measured at 11.1-m distance and found to be near a fourth-power cosine distribution. These results indicate the ability to mass analyze a surface over a distance of many kilometers for lunar and asteroid surface elemental mass analysis by a remote satellite or lunar rover.

Situ, W.↗

Space Station atmospheric monitoring systems

A technology assessment study on atmospheric monitoring systems was performed by Battelle Columbus Division for the National Aeronautics and Space Administration's John F. Kennedy Space Center under Contract No. NAS 10-11033. In this assessment, the objective was to identify, analyze, and recommend systems to sample and measure Space Station atmospheric contaminants and identify where additional research and technology advancements were required. To achieve this objective, it was necessary to define atmospheric monitoring requirements and to assess the state of the art and advanced technology and systems for technical and operational compatibility with monitoring goals. Three technical tasks were defined to support these needs: Definition of Monitoring Requirements, Assessment of Sampling and Analytical Technology, and Technology Screening and Recommendations. Based on the analysis, the principal candidates recommended for development at the Space Station's initial operational capability were: (1) long-path Fourier transform infrared for rapid detection of high-risk contamination incidences, and (2) gas chromatography/mass spectrometry utilizing mass selective detection (or ion-trap) technologies for detailed monitoring of extended crew exposure to low level (ppbv) contamination. The development of a gas chromatography/mass spectrometry/matrix isolation-Fourier transform infrared system was recommended as part of the long range program of upgrading Space Station trace-contaminant monitoring needs.

Air Pollution, Indoor/analysis↗

Quadrupole Ion Mass Spectrometer for Masses of 2 to 50 Da

A customized quadrupole ion-trap mass spectrometer (QITMS) has been built to satisfy a need for a compact, rugged instrument for measuring small concentrations of hydrogen, helium, oxygen, and argon in a nitrogen atmosphere. This QITMS can also be used to perform quantitative analyses of other gases within its molecular-mass range, which is 2 to 50 daltons (Da). (More precisely, it can be used to perform quantitative analysis of gases that, when ionized, are characterized by m/Z ratios between 2 and 50, where m is the mass of an ion in daltons and Z is the number of fundamental electric charges on the ion.

Helms, William↗

Demonstration of Long Vacuum Integrity Lifetime of Trapped Ion Standard Package

A compact Hg ion trap package that was vacuum-sealed since 9 years has been demonstrated to be successfully operational showing excellent ion-trap lifetime exceeding 400 days. In addition to the vacuum package, the same 9-year old optical and detection packages are utilized to obtain these results. Charge transfer relaxation effects between neutral Hg and trapped Hg ion are studied. This work shows the reliability of such units in view of next-generation ground and space-borne trapped ion clocks.

charge-transfer relaxation↗

Synthesis of cerium precursors with alkoxide ligands for degradation to cerium oxide nanoparticles

Lanthanide oxide and sulfide nanoparticles present intriguing theoretical questions regarding their electronic structures, alongside numerous potential applications in material science and catalysis. Although these materials can be formed through hydrolysis, their synthesis via thermolysis is crucial for nanoscale materials and practical applications. This research aims to enhance our understanding of the decomposition mechanisms by focusing on cerium compounds, which are analogous to those studied previously. Currently, our knowledge of the decomposition mechanisms of cerium alkoxide precursors is limited. The objective of this project is to develop a mechanistic understanding of the formation of cerium oxide nanoparticles from cerium alkoxide precursors, employing a variety of techniques. These techniques include collision-induced dissociation in an ion-trap mass spectrometer, nuclear magnetic resonance (NMR) spectroscopy, thermogravimetric analysis coupled with differential scanning calorimetry (TGA-DSC), and gas chromatography-mass spectrometry (GC-MS) to investigate the decomposition mechanisms of the synthesized precursors.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗