Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ions Separations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ligand-Functionalized Polymer Membranes for Selective Ion Separations

Selective ion separations are central to technologies spanning water purification, resource recovery, and clean energy. Conventional polymer membranes, which rely on steric hindrance or Donnan exclusion, struggle to discriminate between chemically similar ions in high-ionic-strength environments. Ligand-functionalized membranes offer a transformative strategy by embedding molecular recognition directly into polymer matrices, enabling selective complexation and transport. Here, this Viewpoint highlights the structure–function relationships underlying ligand-mediated ion separation, emphasizing the interplay of dehydration penalties, ligand coordination, and nanoscale confinement. We discuss design principles, denticity, donor identity, rigidity, and spatial organization, alongside the permeability–selectivity trade-off, multicomponent effects, and stability challenges. Finally, we outline emerging strategies, from bioinspired ligands to computationally guided design, that chart a path toward next-generation membranes for precise and energy-efficient ion separations.

ions↗

A nanoporous capacitive electrochemical ratchet for continuous ion separations

Directed ion transport in liquid electrolyte solutions underlies many phenomena in natural and industrial settings. While nature has evolved structures that drive continuous ion flow without Faradaic redox reactions, establishing this process in synthetic systems has been challenging. Here, in this study, we report an ion pump that drives aqueous ions against a force using a capacitive ratchet mechanism independent of redox reactions. Modulation of an electric potential between thin metallic layers on either face of a nanoporous alumina wafer immersed in solution results in persistent voltages and ionic currents. This occurs due to the nonlinear capacitive nature of electric double layers, whose repeated charging and discharging sustains a continuous ion flux. Using this approach, we demonstrate ratchet-driven electrodialysis that reaches a 50% decrease in the conductivity of the solution in a dilution cell. These ratchet-based ion pumps can enable continuous desalination and selective ion separation using an electrically powered device with no moving parts.

Kautz, Rylan [University of California, Irvine, CA↗

Electrically Driven Ion Separations in Permeable Membranes

Ion separations are critical for producing materials such as Li and rare-earth element salts that are essential for applications including energy storage and production. This research aimed to develop and understand separations of singly and multiply charged ions as well as separations among different singly charged ions such as Li + and Na + . Thin layers of polyelectrolytes on membranes allow passage of singly charged ions at rates 1000 times faster than those for multiply charged ions. This allows purification of mixtures with equal concentrations of Li + and Mg 2+ to create a permeate solution with >99% Li + . Such membranes may also effectively isolate rare earth elements. To separate Li + and K + , this work developed opposing flow and current in membranes. The current overcomes the flow of K + to allow Li + to selectively pass through the membrane, leading to Li + /K + selectivities around 70. All of the research employs modelling to better understand the mechanism of these separations, which includes transport driven by gradients in electrical potential, concentration, and pressure. The interplay of these driving forces can create highly selective separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Adsorptive Membrane Platform for Precision Ion Separation: Membrane Design and First‐Principles Studies

One of the key challenges in separation science is the lack of precise ion separation methods and mechanistic understanding crucial for efficiently recovering critical materials from complex aqueous matrices. Herein, first-principles electronic structure calculations and in situ Raman spectroscopy are studied to elucidate the factors governing ion discrimination in an adsorptive membrane specifically designed for transition metal ion separation. Density functional theory calculations and in situ Raman data jointly reveal the thermodynamically favorable binding preferences and detailed adsorption mechanisms for competing ions. How membrane binding preferences correlate with the electronic properties of ligands is explored, such as orbital hybridization and electron localization. The findings underscore the importance of the phenolate group in oxime ligands for achieving high selectivity among competing transition metal ions. In-depth understanding on which specific atomistic site within the microenvironment of metal-ligand binding pockets governs the ion discrimination behaviors of the host will build a solid foundation to guide the rational design of next-generation materials for precision separation essential for energy technologies and environment remediation. In tandem, synthetic controllability is demonstrated to transform 3D micrometer-scale crystals to a 2D crystalline selective layer in membranes, paving the way for more precise and sustainable advances in separation science.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward Intelligent Multimodal Holography for Real-Time Chemical Imaging of Dynamic Ion Separation

Molecular-level visualization of ion transport and separation dynamics in complex environments is crucial for advancing energy systems, water purification, and critical materials recovery. Achieving this requires imaging platforms that combine structural sensitivity, chemical specificity, and real-time operation. Digital off-axis holography (DOAH) provides high-throughput, label-free quantitative phase imaging but inherently lacks chemical selectivity. Integrating DOAH with complementary spectroscopic channels such as fluorescence or hyperspectral imaging introduces the needed molecular specificity, while also creating challenges in multimodal data fusion, synchronization, and computational throughput. Artificial intelligence offers a powerful route to address these limitations by uniting physics-based reconstruction with data-driven interpretation. In this Perspective, we outline a framework for intelligent multimodal holography and demonstrate its potential using a preliminary AI-driven test case. Raw DOAH holograms of lanthanide solutions subjected to magnetic field gradients were analyzed using multi-agent AI workflows that autonomously selected reconstruction tools, extracted NMF components, and generated scientific claims consistent with true paramagnetic and diamagnetic behavior. This demonstration shows how AI-enabled reasoning can deliver real-time chemical–structural interpretation directly from raw holograms. Together, these advances define a path toward adaptive, intelligent holography platforms capable of supporting in situ chemical separations, dynamic ion transport analysis, and next-generation interfacial science.

Ricchiuti, Giovanna↗

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations

Ion mobility-mass spectrometry (IMS-MS) is increasingly used to analyze complex samples and provide structural information of unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. In this work, we evaluated a cyclable and variable-pathlength multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators and a path length of ~88 meters (~11 meters per level). Our new multilevel SLIM can also be operated in an ‘ion cycling’ mode where a set of return ion escalators transport ions from the eighth back to the first level, allowing even longer path lengths (and higher IMS resolution). The platform has been improved to enhance the ion transmission and IMS separation quality by reducing the spacing between SLIM boards as well as board thickness, reducing the ions’ escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated a better transmission for a set of phosphazene ions, especially for the low-mobility ions. The new multilevel SLIM achieved better resolving powers than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of singly-charged reverse sequence peptides (SDGRG 1+ , GRGDS 1+ ). We achieved 1100 resolving power using 88 meters of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels (i.e., 16 levels or 173.5 m). The multilevel SLIM was further evaluated to demonstrate the enhanced separation for a positively and negatively charged brain total lipid extract sample. Finally, the new multilevel SLIM enables much higher resolving powers for a wide range of ion mobilities, improved transmission for low-mobility ions, and the ability to perform even higher resolving power for ions of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scalable slot-die coating of phyllosilicate membranes for selective ion separations

Abstract Two-dimensional (2D) materials have recently drawn attention as candidate materials for molecular-scale membrane separations due to their tunable nanoscale interlayer properties. Phyllosilicates, a broad class of naturally abundant 2D clay minerals, offer significant advantages over synthetic 2D materials, including low cost, stability, and environmental compatibility. While these properties make phyllosilicates attractive for industrial-scale nanofiltration applications, phyllosilicate-based membranes have, to date, only been fabricated at the lab scale via vacuum filtration. Scalable fabrication methods are essential to advance the technical maturity of phyllosilicate membranes and bring these promising materials closer to large-scale adoption. Herein, we have successfully scaled up phyllosilicate (vermiculite) membrane fabrication via slot-die coating and roll-to-roll coating of an ethylenediamine–vermiculite (EDAVM) mixture onto nylon. The coated membranes are 1–2 μm $ \unicode{x03BC} \mathrm{m} $ mu m in thickness and exhibit similar structure and performance to vacuum-filtered EDAVM membranes. The membranes also show selectivity for monovalent ions over multivalent ions in binary salt mixtures. This work represents a major step toward scaling up phyllosilicate membranes for industrial ion separation applications such as resource recovery from water.

Booth, Austin [Princeton University]↗

Selective partitioning and uphill transport enable effective Li/Mg ion separation by negatively charged membranes

Efficient separation of lithium (Li + ) and magnesium (Mg 2+ ) is critical for enhancing sustainable lithium extraction from natural brines, which is vital for battery production and renewable energy technologies. Here we present a method for highly selective Li + /Mg 2+ separation driven by concentration gradients across negatively charged membranes with high charge densities. In contrast to typical electric field-driven transport in negatively charged membranes, where divalent cations generally permeate faster than monovalent cations, Li + ions in our system permeate the membrane at substantially higher rates than Mg 2+ ions. This unexpected selectivity stems from the selective ion partitioning properties of the membrane and the uphill transport of Mg 2+ ions against their external concentration gradient. We demonstrate the efficacy of this separation approach through bench-scale dialysis experiments using a model Atacama brine solution, achieving efficient separation of monovalent and divalent cations. As a result, the high separation efficiency observed in this study suggests a promising approach for monovalent/divalent ion separations, offering higher selectivity compared to current technologies.

36 MATERIALS SCIENCE↗

Electric Field’s Dueling Effects through Dehydration and Ion Separation in Driving NaCl Nucleation at Charged Nanoconfined Interfaces

Investigating nucleation in charged nanoconfined environments under electric fields is crucial for many scientific and engineering applications. Here we study the nucleation of NaCl from aqueous solution near charged surfaces using machine-learning-augmented enhanced sampling molecular dynamics simulations. Our simulations successfully drive phase transitions between the liquid and solid phases of NaCl. The solid phase is stabilized under electric fields, particularly at an intermediate surface charge density. We examine which physical characteristics drive the nucleation of NaCl from aqueous solutions and find that the removal of solvent water from Cl– at the solid precursor surface plays a more critical role than the accumulation of ions. Our simulations reveal the competing effects of electric fields on nucleation processes: they facilitate the removal of water, promoting nucleation, but also promote the separation of ion pairs, thereby hindering nucleation. Here, this work provides a framework for studying nucleation processes in nanoconfined environments under electric fields and provides physical insights for the design of electrochemistry materials.

Electric fields↗

Continuous Ion Separations by Insertion Processes

Humanity is reliant on many important chemical separations which are performed daily at the industrial scale. With a historical dependence on thermal distillation techniques, which require large amounts of energy, chemical separations account for 10-15% of energy consumption worldwide. Membrane-based alternatives mitigate separation energy demand, yet prove challenging to scale-up and possess intrinsic limitations. Membranes usually separate species based on size and charge exclusion mechanisms. Importantly, however, improvements in the selectivity of membranes almost always leads to lower permeability. Much of the fundamental research in the field of membrane separations is focused on breaking the scaling relationship between selectivity and permeance, and improving membrane lifetime and stability. As discussed next, our group is developing electrochemically active membranes that can be actuated by application of an electric field. The long-term goal is to control selectivity and permeance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Mobility Separations Using Cocentric Architecture

Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.

59 BASIC BIOLOGICAL SCIENCES↗

Method and apparatus for ion mobility separations utilizing alternating current waveforms

Methods and apparatuses for ion manipulations, including ion trapping, transfer, and mobility separations, using traveling waves (TW) formed by continuous alternating current (AC) are disclosed. An apparatus for ion manipulation includes a surface to which are coupled a first plurality of continuous electrodes and a second plurality of segmented electrodes. The second plurality of segmented electrodes is arranged in longitudinal sets between or adjacent to the first plurality of electrodes. An RF voltage applied to adjacent electrodes of the first plurality of electrodes is phase shifted by approximately 180° to confine ions within the apparatus. An AC voltage waveform applied to adjacent electrodes within a longitudinal set of the second plurality of segmented electrodes is phase shifted on the adjacent electrodes by 1°-359° to move ions longitudinally through the apparatus for separation.

Garimella, Venkata B. S.↗

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Gas-Phase Native(-like) Proteins Using Structures for Lossless Ion Manipulations

High-resolution mobility-based ion separations in Structures for Lossless Ion Manipulations (SLIM) have been useful for ion mobility separations for a variety of molecular classes in the gas phase. Here, in this study, we present multipass SLIM separations for gas-phase proteins in their near-native state exhibiting charge-state-dependent arrival time distributions using carbonic anhydrase (29 kDa), alcohol dehydrogenase (148 kDa), and apo-transferrin (79 kDa). The experimental CCS values were obtained from calibration curves for the arrival times of Agilent Tune Mix ions. For multipass separations, the ATDs were converted to CCS values by deconvoluting the multipass arrival times into accurate single-pass values amenable to the single-pass calibration curves. Mass spectra of carbonic anhydrase (CA) showed three different charge states (z = 9+ to 11+). Their corresponding mobility peaks were baseline-separated by using 8-m single-pass separations. When compared to the corresponding drift tube ion mobility (DTIMS) measurements, the CCS values obtained from DTIMS and SLIM were in agreement within experimental error. Single-pass analysis of alcohol dehydrogenase (ADH) exhibits three predominant charge states (z = 23+ to 25+) with mobility overlap between adjacent charge states. The mobility peak resolution for ADH improved with multipass separations (up to 24-m path length). In addition, CCS distributions obtained for charge states z = 16+ to 18+ of apo-transferrin reveal a transition from a compact unimodal form (z = 18+ and 19+) to broader multimodal CCS distributions for z = 16+. For apo-transferrin, 40-m multipass separations were performed allowing for complete isolation of the selected mobility range corresponding to z = 17+, leading to selective isolation of a narrow arrival time window. The extended mobility separations provided minimal alterations to the structure of the proteins, and the experimentally derived CCS values showed minimal change as a function of the separation time or number of passes. Mobility-based ion separations for native-like proteins, using SLIM, open opportunities for native-IMS applications as well as other manipulations enabled by SLIM-like mobility-selective isolation and collection.

charge state distribution↗

Fast ground-state-to-ground-state separation of small ion crystals

Rapid separation of linear crystals of trapped ions into different subsets is critical for realizing trapped ion quantum computing architectures where ions are rearranged in trap arrays to achieve all-to-all connectivity between qubits. Here we introduce a general theoretical framework that can be used to describe the separation of same-species and mixed-species crystals into smaller subsets. The framework relies on an efficient description of the evolution of Gaussian motional states under quadratic Hamiltonians that only requires a special solution of the classical equations of motion of the ions to describe their quantum evolution under the influence of a time-dependent applied potential and the ions' mutual Coulomb repulsion. We provide time-dependent applied potentials suitable for separation of a mixed-species three-ion crystal on timescales similar to that of free expansion driven by Coulomb repulsion, with all modes along the crystal axis starting and ending close to their ground states. Three separately confined mixed-species ions can be combined into a crystal held in a single well without energy gain by time-reversal of this separation process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High resolution mobility spectrometry in a co-axial platform

Ion mobility spectrometry is an analytical technique that separate ions in the gas phase based on their interaction with a neutral buffer gas. Ion mobility spectrometry performs separations quickly (typically less than a second) and the ion mobilities are very reproducible across different laboratories. This project aimed at evaluating the performance of a new ion mobility device. The new device relies on conducting ion mobility separation in a curved geometry. The project explored the operation landscape of the device using ion trajectory simulations then fabricated and experimentally demonstrated the device's performance. Ion trajectory simulations on a set of tetraalkylammonium and phosphazene ions indicate that ions traveling a curved path length undergo mobility separation that is similar to a straight path. The ion mobility resolution of the curved device was found to be similar to that of a straight path of a similar length. The experimental validation of the new device confirmed the device's ability to separate ions according to their mobilities. Sets of mixtures (tetraalkylammonium ions, phosphazene ions, and peptide ions) were evaluated for separation and transmission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗