Search NASA⌕ Search

SEARCH · Search NASA

Results for “Isolation Condenser”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

System Study: Isolation Condenser 1998–2013

This report presents an unreliability evaluation of the isolation condenser (ISO) system at four U.S. boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2013 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the ISO results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System Study: Isolation Condenser 1998-2020

This report presents an unreliability evaluation of the isolation condenser (ISO) system at four U.S. boiling water reactors. Demand, run hours, and failure data from calendar year 1998 through 2020 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the ISO results.

99 GENERAL AND MISCELLANEOUS↗

System Study: Isolation Condenser 1998-2022

This report presents an unreliability evaluation of the isolation condenser (ISO) system at three U.S. commercial operating boiling water reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from calendar year 1998–2022 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the ISO results.

99 GENERAL AND MISCELLANEOUS↗

System Study: Isolation Condenser 1998-2014

This report presents an unreliability evaluation of the isolation condenser (ISO) system at four U.S. boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2014 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing trends were identified. A statistically significant decreasing trend was identified for ISO unreliability. The magnitude of the trend indicated a 1.5 percent decrease in system unreliability over the last 10 years.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System Study: Isolation Condenser 1998–2018

This report presents an unreliability evaluation of the isolation condenser (ISO) system at four U.S. boiling water reactors. Demand, run hours, and failure data from calendar year 1998 through 2018 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the ISO results.

99 GENERAL AND MISCELLANEOUS↗

One-step lignocellulose depolymerization and saccharification to high sugar yield and less condensed isolated lignin

The cost of sugar production remains a key challenge in future lignocellulosic biorefineries. We demonstrate that ZnBr 2 , an inexpensive inorganic salt, provides nearly theoretical yields of glucose and xylose in one-step from poplar wood at 85 °C and short reaction times at molten salt hydrate (MSH) conditions without an acid. Catalytic depolymerization of the isolated MSH lignin, using a CoS 2 catalyst, yields 17% phenol-like monomers compared to only 1% produced from the acidified MSH lignin. Reductive catalytic fractionation of MSH lignin over Ru/C resulted in two times higher total monomer yield compared to the AMSH lignin. Both the lignin samples were characterized using 2D HSQC NMR and the thioacidolysis method. Thioacidolysis studies reveal 8.4% and 1.8% of β-O-4 linkages in MSH and acidified MSH lignin, respectively. Thermodynamic modeling and 13 C NMR spectroscopy indicate that the effectiveness of this catalyst arises from the strong interaction of the Lewis acidic zinc cation (Zn 2+ ) with the coordinated water molecules resulting in hydrolysis of the metal aquo complex and to the salt-driven increase in the H + activity coefficient. Techno-economic analysis demonstrates that despite being slower, the ZnBr 2 MSH media has cost advantages, compared to conventional hydrolysis and even to the LiBr and ZnBr 2 AMSH, due to the higher quality of lignin.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Steady evaporation and condensation of isolated clouds in hot plasma

The evaporation and condensation of an isolated cloud embedded in a thermally stable hot gas is studied under the assumption that the ambient hot gas is in thermal equilibrium at constant temperature and that the cloud is large enough that classical conduction is valid. It is found that the cloud will evaporate provided that it is smaller than the Field length, which gives the maximum range of thermal conduction. A large cloud can condense only if the pressure exceeds the saturated vapor pressure p(sat). The pressure required for condensation increases as the cloud radius decreases, until condensation becomes impossible. Since p(sat) is close to the maximum pressure at which the hot gas can exist in equilibrium, condensation is likely to occur under unsteady conditions. The Compton-bremsstrahlung case is treated as an example.

Mckee, Christopher F.↗

Preliminary analysis of loss-of-coolant accident in Fukushima nuclear accident

Loss-of-Coolant Accident (LOCA) in Boiling Water Reactor (BWR) especially on Fukushima Nuclear Accident will be discussed in this paper. The Tohoku earthquake triggered the shutdown of nuclear power reactors at Fukushima Nuclear Power station. Though shutdown process has been completely performed, cooling process, at much smaller level than in normal operation, is needed to remove decay heat from the reactor core until the reactor reach cold-shutdown condition. If LOCA happen at this condition, it will cause the increase of reactor fuel and other core temperatures and can lead to reactor core meltdown and exposure of radioactive material to the environment such as in the Fukushima Dai Ichi nuclear accident case. In this study numerical simulation has been performed to calculate pressure composition, water level and temperature distribution on reactor during this accident. There are two coolant regulating system that operational on reactor unit 1 at this accident, Isolation Condensers (IC) system and Safety Relief Valves (SRV) system. Average mass flow of steam to the IC system in this event is 10 kg/s and could keep reactor core from uncovered about 3,2 hours and fully uncovered in 4,7 hours later. There are two coolant regulating system at operational on reactor unit 2, Reactor Core Isolation Condenser (RCIC) System and Safety Relief Valves (SRV). Average mass flow of coolant that correspond this event is 20 kg/s and could keep reactor core from uncovered about 73 hours and fully uncovered in 75 hours later. There are three coolant regulating system at operational on reactor unit 3, Reactor Core Isolation Condenser (RCIC) system, High Pressure Coolant Injection (HPCI) system and Safety Relief Valves (SRV). Average mass flow of water that correspond this event is 15 kg/s and could keep reactor core from uncovered about 37 hours and fully uncovered in 40 hours later.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Isolated grain condensation behavior: Computation methods and first results

A set of efficient programs for calculation of condensation behavior in a system with either solar or carbon-rich elemental composition was developed to treat the course of condensation at very low pressures. These programs were applied to the problem of condensation at very low pressures. The minerals produced in the stellar and nova-related processes under study, including carriers of important volatile elements such as carbon and nitrogen, are candidates for accretion into meteorite parent bodies and planets, and may still be discernible in the enstatite chondrites.

Lewis, J. S.↗

ESBWR response to an extended station blackout/loss of all AC power

U.S. federal regulations require light water cooled nuclear power plants to cope with Station Blackouts for a predetermined amount of time based on design factors for the plant. U.S. regulations define Station Blackout (SBO) as a loss of the offsite electric power system concurrent with turbine trip and unavailability of the onsite emergency AC power system. According to U.S. regulations, typically the coping period for an SBO is 4 hours and can be as long as 16 hours for currently operating BWR plants. Being able to cope with an SBO and loss of all AC power is required by international regulators as well. The U.S. licensing basis for the ESBWR is a coping period of 72 hours for an SBO based on U.S. NRC requirements for passive safety plants. In the event of an extended SBO (viz., greater than 72 hours), the ESBWR response shows that the design is able to cope with the event for at least 7 days without AC electrical power or operator action. ESBWR is a Generation III+ reactor design with an array of passive safety systems. The ESBWR primary success path for mitigation of an SBO event is the Isolation Condenser System (ICS). The ICS is a passive, closed loop, safety system that initiates automatically on a loss of power. Upon Station Blackout or loss of all AC power, the ICS begins removing decay heat from the Reactor Pressure Vessel (RPV) by (i) condensing the steam into water in heat exchangers located in pools of water above the containment, and (ii) transferring the decay heat to the atmosphere. The condensed water is then returned by gravity to cool the reactor again. The ICS alone is capable of maintaining the ESBWR in a safe shutdown condition after an SBO for an extended period. The fuel remains covered throughout the SBO event. The ICS is able to remove decay heat from the RPV for at least 7 days and maintains the reactor in a safe shutdown condition. The water level in the RPV remains well above the top of active fuel for the duration of the SBO event. Beyond 7 days, only a few simple actions are needed to cope with the SBO for an indefinite amount of time. The operation of the ICS as the primary success path for mitigation of an SBO, allows for near immediate plant restart once power is restored. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The circumstellar environment of IRAS 05338-0624

Millimeter continuum and spectral line observations with 10 sec, 30 sec, and 60 sec resolution are used to characterize the structure and chemistry of the gas around the young, embedded star, IRAS 05338-0624. On arcminute scales, emission from dense gas tracers outline an isolated condensation centered on the IRAS source position. The condensation is characterized by a size of approximately 60 sec, a density of 2 x 10(exp 5)/cc, and a virial mass of 40 solar mass. Interferometric CS J = 2-1 observations show two peaks, one toward the continuum peak and the other toward a position 14 sec west and 8 sec south. Single-dish maps of SO, CH3OH, and SiO show pronounced wing emission to the west of the IRAS source, which interferometer observations reveal to be a compact region of outflow activity. CS emission at redshifted and blueshifted velocities reveals a bipolar outflow oriented with a position angle of 45 deg, while SiO emission appears to be tracing a fast shock interaction region at the CS red-lobe peak, 14 sec west and 8 sec south of the IRAS source. Finally, H(13)CO(+) emission traces clumps of quiescent gas toward the IRAS source and adjacent to the blue lobe of the outflow. Column densities and molecular fractional abundances are derived to explore the interaction between the surrounding condensation and the young stellar object. We find evidence for gas phase depletions within the overall condensation in several gas tracers (CO, CS, HCN, SO) but not in the region immediately around the young stellar object. Enhanced abundances of SO, CH3OH, and SiO (by factors of 4, greater than 100, greater than 1000, respectively) are observed in the shocked gas; these enhancements may be explained in terms of a nondissociative shock liberating mantle materials that contain some amount of refractory materials, a moderate velocity dissociative shock in which only minor sputtering of Si occurs, or a shock that impacts surrounding material with a range of speeds.

Mcmullin, Joseph P.↗

Developing A Fully Implicit Compressible Flow Valve Model in RELAP-7 and Its Application in Short Term BWR Station Black-Out Analyses

This paper presents a set of dynamical models for SRV simulation and their implementation in the RELAP-7 code, which is a new reactor system analysis code being developed at INL. RELAP-7 is based on the MOOSE (the Multi-Physics Object-Oriented Simulation Environment) framework. The compressible flow SRV model covers three different sets of models: fully closed case, subsonic case, and choking case. The RELAP-7 is a fully implicit code and the preconditioned Jacobian-free Newton-Krylov (JFNK) method is used to solve the discretized nonlinear problem. The JFNK method generally needs a good preconditioning scheme to be effective and efficient. There are different ways to precondition the JFNK method. In RELAP-7, two main options are used to obtain the preconditioning matrix: (1) FDP (Finite Difference Preconditioning) option which uses the default finite differencing method provided in the PETSc package. PETSc is the numerical solver software developed by Argonne National Laboratory and used by MOOSE as the numerical solution engine; (2) SMP (Single Matrix Preconditioning) option which requires code developers to provide approximate analytical Jacobian inputs for the important diagonal and off-diagonal terms. Due to the strong discontinuity in the residual vector space when the compressible flow valve model switches from one set of model to another, FDP option cannot guarantee convergence. Instead, accurate analytical Jacobain terms are provided for the compressible flow valve model. With the SMP option selected, the compressible flow valve model can be solved efficiently under different cases. The developed compressible flow valve model has been used for SRV component simulation in several simplified BWR SBO (Station Black-Out) simulations with RELAP-7. This paper only presents cases for short-term SBO in which all the safety systems fail to start and function properly when SBO occurs. Consequently, only the SRVs automatically open and close periodically to control the primary system pressure and discharge the high temperature and high pressure steam into the suppression pool. Although simplified, this case is quite similar to what happened in Fukushima Daiichi Unit 1. Unit 1 had no RCIC system, while the isolation condenser system was believed to be non-functioning, or only available for a very short period of time during the accident. Therefore, the Unit 1 reactor core reached a fuel failure temperature only a few hours into the accident. Two short-term SBO cases will be compared: one with single SRV discharge line which represents all the SRV lines and another case with multi-group SRVs which represent each group of SRV line with different setting points.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Condenser Enclosure Vibration Isolation Mount Selection

A mini split cooling system will be used to maintain temperature requirements in a mobile secure transport system. While the split cooling system was designed to be used in static residential or commercial applications, it was selected for this transportation application due to a unique set of security requirements. However, the system’s ability maintain reliability and survive prolonged long-term shock and vibration is a significant concern. The mitigation strategy is to select vibration isolation mounts and perform lifetime shock and vibration testing to demonstrate survivability. The goal of this study is to generate a finite element model of the system and perform modal analysis to inform selection of vibration mounts to minimize the amount of vibrational energy transferred to the split cooling system. The scope of this report is limited to study of the condensing unit only, and geometric variation of the assembly will not be allowed.

42 ENGINEERING↗

Impact of synchronous condensers on fault location and black start in multi-inverter isolated microgrids

Synchronous condensers have been used in power systems for decades, but they are now attracting interest as a potential means for solving certain issues associated with inverter-based resources in islanded power systems. They have been extensively studied in applications to large wind farms and weak grids, but there has been very little study of synchronous condensers in intentionally-islanded systems, and especially self-healing ones. This report documents the results of an LDRD project intended to create modeling tools for use in the study of synchronous condensers in these smaller off-grid systems, and to explore synchronous condensers in this application. The results indicate that synchronous condensers have the potential to provide many benefits, but there are also several unanswered questions and technical challenges requiring further study.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental and Computational Studies of Carbon–Carbon Bond Formation via Ketonization and Aldol Condensation over Site-Isolated Zirconium Catalysts

We report here the preparation and investigation of isolated Zr centers supported on a high surface area silica for the conversion of carboxylic acids to internal ketones by ketonic decarboxylation (ketonization) and the aldol condensation of ketones to dimeric enones. Catalysts were synthesized by the grafting of Cp 2 ZrCl 2 on the surface of amorphous silica. The connectivity of Zr was characterized by XRD, UV-vis, and Raman spectroscopy. For the lowest Zr loading, Zr is present predominantly as isolated monomeric species. As the Zr loading is increased, a progressively larger fraction of Zr forms oligomeric species and ZrO nanoparticles. Measurements of catalytic activity show that the turnover frequency for carboxylic acid ketonic decarboxylation reaction and aldol condensation of ketones decreases monotonically with increasing Zr loading. An H/D kinetic isotope effect was not observed over isolated Zr catalysts, suggesting that α-H abstraction is not the rate-determining step, rather C-C bond forming may be rate limiting for both reactions. This conclusion is supported by computational modeling of the reaction mechanism. The proposed catalytic cycle for ketonization proceeds via a β-keto acid intermediate on isolated Zr sites that are always coordinatively saturated with C-C bond formation as the rate-limiting step. C-C bond formation is also rate-determining for aldol condensation, with an apparent activation energy that is in good agreement with the experiment if the resting state is a saturated ≡ZrOH site with two adsorbed ketone molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strong interlayer charge transfer due to exciton condensation in an electrically isolated GaAs quantum well bilayer

We introduce a design of electrically isolated “floating” bilayer GaAs quantum wells (QW), in which application of a large gating voltage controllably and highly reproducibly induces charges that remain trapped in the bilayer after removal of the gating voltage. At smaller gate voltages, the bilayer is fully electrically isolated from external electrodes by thick insulating barriers. This design permits full control of the total and differential densities of two coupled 2D electron systems. The floating bilayer design provides a unique approach for studying systems inaccessible by simple transport measurements. It also provides the ability to measure the charge transfer between the layers, even when the in-plane resistivities of the 2D systems diverge. We measure the capacitance and inter-layer tunneling spectra of the QW bilayer with independent control of the top and bottom layer electron densities. Our measurements display strongly enhanced inter-layer tunneling current at v T =1, a signature of exciton condensation of a strongly interlayer-correlated bilayer system. With fully tunable densities of individual layers, the floating bilayer QW system provides a versatile platform to access previously unavailable information on the quantum phases in electron bilayer systems.

42 ENGINEERING↗

Planetary atmospheres program

Chemical and physical models of the Jovian subnebula are addressed. Halide cloud condensation and volatile element inventories on Venus and considered. Computation methods for isolated grain condensation behavior are examined.

Source record↗

A spectroscopic study of intermediates in the condensation of refractory smokes: Matrix isolation experiments SiO

The infrared and Raman spectra of N2 matrix isolated silicon oxides are investigated. The vibrational frequencies of SiO, Si2O2, and Si3O3 were identified and assigned on the basis of normal coordinate analyses. Heating the solid to 50 K (evaporating the matrix) leaves a residue whose infrared spectrum is identical to that of a smoke condensed at ambient temperatures. Further heating of the sample to 500 K leads to significant changes in the band shapes. Investigations of the infrared spectra at several stages of the diffusion process result in the proposal of a mechanism for the transition from molecular properties to those of the residue (bulk) material, which is characterized as Si2O3.

Khanna, R. K.↗