Search NASA⌕ Search

SEARCH · Search NASA

Results for “Isotope Ratio Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Using Separation-Enhanced Isotope Ratio Mass Spectrometry

Stable isotope ratio measurements using IRMS have been shown by LANL to be effective for tracking co-processed biogenic carbon, with results approaching that of AMS. The lower cost of an IRMS may enable deployment to refineries improving access and analysis turnaround times (≤ 2-hours), and by extension data that can allow process optimization to maximize renewable carbon in desired refinery products. This work will apply chemical separation approaches as part of the IRMS analyses, enabling biogenic carbon tracking in fuel product streams by boiling point range, by chemical class, or even by compound. This work will show IRMS to be at a minimum as reliable and comparable to AMS, by using separations to improve sensitivity at low blend ratios and enable refinery process optimization through onsite analysis.

36 MATERIALS SCIENCE↗

Using Separation-Enhanced Isotope Ratio Mass Spectrometry to Enable Increased Renewable Carbon Content in Transportation Fuels (CRADA 525)

Stable isotope ratio measurements of carbon atoms using isotope ratio mass spectrometry (IRMS) can be an effective tool for quantifying biogenic carbon in co-processed fuels, with results approaching the precision and accuracy of accelerator mass spectrometry (AMS). The lower cost of an IRMS may enable deployment to refineries, improving access and analysis turnaround times (≤2 hours), and, by extension, provide data that can allow process optimization to maximize renewable carbon in desired refinery products. This project explored the integration of chemical separation with IRMS analyses to enable highly detailed tracking of biogenic carbon into fuel product streams separated by boiling point range, chemical class, or specific compound. Forty-nine fuels and fuel components of fossil and biogenic origin, spanning gasoline and diesel boiling point ranges, were received from three refiners and were analyzed for their δ 13 C values via IRMS. Results spanned a 13 C range from ca. 10‰ to 44‰ and reflect materials derived from sustainable sources (e.g., C4 or C3 plants, animal-based pathways, syngas) or from fossil-derived fuels. Common ranges are approximately 18‰ to 9‰ and approximately 30‰ to 20‰ for C4 and C3 plants, respectively, and approximately 34‰ to 24‰ and approximately 70‰ to 33‰ for petroleum-derived fuels and methane, respectively. Fuel-like standards were developed and tested using direct-injection elemental analyzer (EA) IRMS for liquid fuels. This method was compared with the published methods, yielding statistically similar results. Four blend curve sets were produced ranging from 0% to 100% of a fuel containing biogenic carbon, focusing on 0% to 10% biogenic carbon. Linear fits were the most applicable for two of the four blend curve sets; however, two sets were found to exhibit slightly quadratic behavior, which was more pronounced in low biogenic blend samples, necessitating second-order fits. The origin of the slight quadratic behavior remains unclear; however, the discussion points to possible interpretations. CanmetENERGY thoroughly characterized a majority of the samples using one- and two-dimensional gas chromatography (GC and GC×GC, respectively) and other analyses. Selected samples were subjected to solid phase extraction (SPE) for saturate, olefin, aromatic, and polar (SOAP) analysis, and the resulting solvent-diluted fractions containing saturates and aromatics were returned to Pacific Northwest National Laboratory (PNNL), where the solvent was removed via evaporation or physical separation using GC techniques. Characterization and separations provided an understanding of saturate and aromatic content, as well as boiling point ranges for each sample and sample fraction. Samples resulting from SPE were examined using EA-IRMS and gas chromatography combustion IRMS (GC-C-IRMS) analyses. Both approaches suggest that the range in values between end-members can be increased by selecting the paraffinic or aromatic fraction of the end-member or by selecting among individual compounds resulting from GC separation of the paraffinic fractions. Considerable work remains to put these approaches into practice and statistically validate the benefit for using a fraction or individual compound over bulk analysis of a sample. However, initial results suggest that separations provide advantages for samples having blend ratios of less than 10% biogenic blendstocks. 13 C results showed statistically similar biofuel blend results to those obtained at PNNL, although additional work is needed to obtain better reproducibility. Select samples were sent to Los Alamos National Laboratory (LANL) for IRMS measurements and Beta Analytics for AMS measurements. This work suggests that IRMS and AMS yield closely comparable results and in some circumstances, IRMS could serve as a surrogate for AMS. While additional work is needed to better resolve statistical advantages for separations and better show the comparable nature of IRMS and AMS in both the biogenic carbon analysis of bulk chemical classes, initial results from this study suggest that these should be pursued in order to proliferate this approach for quantifying biogenic carbon in transportation fuels to the refinery level, thereby potentially enabling process optimization in co-processing scenarios.

09 BIOMASS FUELS↗

Large-Volume Injection and Assessment of Reference Standards for n -Alkane δD and δ 13 C Analysis via Gas Chromatography Isotope Ratio Mass Spectrometry

Compound-specific stable isotope analysis of hydrogen (δD) and carbon (δ 13 C) in organic compounds is a valuable tool in biogeochemical research. A key limitation of this method is the relatively large amount of sample required to achieve desirable precision. We developed a large-volume (20 μL) injection method that allows for high throughput analysis of less concentrated samples and tested it for δ 13 C and δD measurements of n-alkanes. We also conducted a comparison of reference standards and assessed several methods to normalize and correct n-alkane δD and δ13C measurements. The mean precision of the δD method based on 233 environmental n-alkane samples (two to three replications per sample) is 4.0‰ (1σ, estimated from the weighted mean of the pooled unbiased standard deviations) and 0.46‰ (1σ) for δ 13 C from 37 environmental samples (two to three replications per sample). The evaluation of reference standards shows that the use of n-alkane standards with large offsets in δD values in adjacent n-alkane chains can lead to biases in measurement correction. The large-volume injection method shows good reproducibility of δ 13 C and δD measurements of n-alkanes and reduces the required sample concentration by about 80%. We propose that for δD measurements, a reference standard set should be used in which each reference standard has a limited range of δD values and no adjacent n-alkane chains, to minimize memory effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbonate clumped isotope analysis (Δ 47 ) of 21 carbonate standards determined via gas‐source isotope‐ratio mass spectrometry on four instrumental configurations using carbonate‐based standardization and multiyear data sets

Rationale Clumped isotope geochemistry examines the pairing or clumping of heavy isotopes in molecules and provides information about the thermodynamic and kinetic controls on their formation. The first clumped isotope measurements of carbonate minerals were first published 15 years ago, and since then, interlaboratory offsets have been observed, and laboratory and community practices for measurement, data analysis, and instrumentation have evolved. Here we briefly review historical and recent developments for measurements, share Tripati Lab practices for four different instrument configurations, test a recently published proposal for carbonate‐based standardization on multiple instruments using multi‐year data sets, and report values for 21 different carbonate standards that allow for recalculations of previously published data sets. Methods We examine data from 4628 standard measurements on Thermo MAT 253 and Nu Perspective IS mass spectrometers, using a common acid bath (90°C) and small‐sample (70°C) individual reaction vessels. Each configuration was investigated by treating some standards as anchors (working standards) and the remainder as unknowns (consistency standards). Results We show that different acid digestion systems and mass spectrometer models yield indistinguishable results when instrument drift is well characterized. For linearity correction, mixed gas‐and‐carbonate standardization or carbonate‐only standardization yields similar results. No difference is observed in the use of three or eight working standards for the construction of transfer functions. Conclusions We show that all configurations yield similar results if instrument drift is robustly characterized and validate a recent proposal for carbonate‐based standardization using large multiyear data sets. Δ 47 values are reported for 21 carbonate standards on both the absolute reference frame (ARF; also refered to as the Carbon Dioxide Equilibrated Scale or CDES) and the new InterCarb‐Carbon Dioxide Equilibrium Scale (I‐CDES) reference frame, facilitating intercomparison of data from a diversity of labs and instrument configurations and restandardization of a broad range of sample sets between 2006, when the first carbonate measurements were published, and the present.

58 GEOSCIENCES↗

Natural Abundance Isotope Ratio Measurements of Organic Molecules Using 21 T FTICR MS

Subtle variations in stable isotope ratios at natural abundance are challenging to measure but can yield critical insights into biological, physical, and geochemical processes. Well established methods, particularly multi-collector, gas-source or plasma isotope ratio mass spectrometry (IRMS) are the gold standard for stable isotope measurement but inherent limitations in these approaches make them ill-suited to determining site-specific and multiply substituted isotopic abundances of all but a few compounds, or to characterizing mixtures or larger intact molecules. Additionally, Fourier transform mass spectrometry (FTMS), namely Orbitrap mass spectrometry, has recently demonstrated the ability to measure natural abundance isotope ratios with chemically informative accuracy and precision. Here, we report the first use of Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) for the accurate (<1‰) and precise (<1‰ standard error) simultaneous determination of $δ$ 13 C and $δ$ 15 N in caffeine isotopologues and provide a discussion of the critical instrumental parameters necessary to make such measurements. Finally, we report the ability to make these measurements with online liquid chromatography, expanding the ability of this technique to explore mixtures in the future.

07 ISOTOPE AND RADIATION SOURCES↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗

Establishing the accuracy of position–specific carbon isotope analysis of propane by GC–pyrolysis–GC–IRMS

Rationale: Position-specific (PS) δ 13 C values of propane have proven their ability to provide valuable information on the evolution history of natural gases. Two major approaches to measure PS δ 13 C values of propane are isotopic 13 C nuclear magnetic resonance (NMR) and gas chromatography-pyrolysis-gas chromatography-isotope ratio mass spectrometry (GC-Py-GC-IRMS). Measurement accuracy of the isotopic 13 C NMR has been verified, but the requirements of large sample size and long experimental time limit its applications. GC-Py-GC-IRMS is a more versatile method with a small sample size, but its accuracy has not been demonstrated. Methods: We measured the PS δ 13 C values of propane from nine natural gases using both 13 C NMR and GC-Py-GC-IRMS, then evaluated the accuracy of the GC-Py-GC-IRMS method. Results: The results show that large carbon isotope fractionations occurred for both terminal and central carbons within propane during pyrolysis. The isotope fractionations during the pyrolysis are reproducible at optimum conditions, but vary between the two GC-Py-GC-IRMS systems tested, affected by experimental conditions (e.g., pyrolysis temperature, flow rate, and reactor conditions). Conclusions: It is necessary to evaluate and calibrate each GC-Py-GC-IRMS system using propane gases with accurately determined PS δ 13 C values. Finally, this study also highlights a need for PS isotope standards for propane and other molecules (e.g., butane and acetic acid).

03 NATURAL GAS↗

Retaining Geochemical Signatures during Aragonite-Calcite Transformation at Hydrothermal Conditions

Transformation of aragonite, a mineral phase metastable at Earth’s surface, to calcite widely occurs in both sedimentary and metamorphic systems with the presence of an aqueous phase. The transformation process can affect geochemical signatures of aragonite (a protolith). This study focused on quantification of the retention of Mg/Ca and Sr/Ca ratios, and δ18O during the transformation process as well as evaluation of the transformation rate. To investigate the effect of transformation from aragonite to calcite on elemental and stable isotope ratios, we conducted a series of experiments in NaCl solutions at temperatures between 120 and 184 °C. Two additional experiments at 250 °C were conducted to estimate the transformation rate of aragonite to calcite. Protolith materials consist of (1) synthetic (Mg; Sr-bearing or non-Mg; Sr bearing) needle-shaped microcrystals of aragonite (<5 µm in size) and (2) larger chips (>100 µm in size) of natural aragonite. X-ray diffraction (XRD) showed that microcrystals successfully transformed to calcite within 30 h and scanning electron microscopy (SEM) yielded a change in the crystal size to >10 µm in rhombohedral shape. Electron backscatter diffraction (EBSD) of the larger aragonite chips showed that transformation to randomly oriented calcite occurred at the rims and along the cracks while the core retained an aragonite crystal structure. Isotope-ratio mass spectrometry (IRMS) analyses showed that calcite δ18O was controlled by temperature and δ18O of the solution. The obtained calibration curve of isotope fractionation factor versus temperature is consistent with other studies. Inductively coupled plasma optical emission spectroscopy (ICP-OES) analyses showed that calcite partially or completely retained Mg/Ca and Sr/Ca ratios through the transformation.

58 GEOSCIENCES↗

What can we learn from N 2 O isotope data? – Analytics, processes and modelling

The isotopic composition of nitrous oxide (N 2 O) provides useful information for evaluating N 2 O sources and budgets. Due to the co–occurrence of multiple N 2 O transformation pathways, it is, however, challenging to use isotopic information to quantify the contribution of distinct processes across variable spatiotemporal scales. Here, we present an overview of recent progress in N 2 O isotopic studies and provide suggestions for future research, mainly focusing on: analytical techniques; production and consumption processes; and interpretation and modelling approaches. Comparing isotope–ratio mass spectrometry (IRMS) with laser absorption spectroscopy (LAS), we conclude that IRMS is a precise technique for laboratory analysis of N 2 O isotopes, while LAS is more suitable for in situ/inline studies and offers advantages for site–specific analyses. When reviewing the link between the N 2 O isotopic composition and underlying mechanisms/processes, we find that, at the molecular scale, the specific enzymes and mechanisms involved determine isotopic fractionation effects. In contrast, at plot–to–global scales, mixing of N 2 O derived from different processes and their isotopic variability must be considered. We also find that dual isotope plots are effective for semi–quantitative attribution of co–occurring N 2 O production and reduction processes. More recently, process–based N 2 O isotopic models have been developed for natural abundance and 15 N–tracing studies, and have been shown to be effective, particularly for data with adequate temporal resolution. Here, despite the significant progress made over the last decade, there is still great need and potential for future work, including development of analytical techniques, reference materials and inter–laboratory comparisons, further exploration of N 2 O formation and destruction mechanisms, more observations across scales, and design and validation of interpretation and modelling approaches. Synthesizing all these efforts, we are confident that the N 2 O isotope community will continue to advance our understanding of N 2 O transformation processes in all spheres of the Earth, and in turn to gain improved constraints on regional and global budgets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fractionation of Oxygen Isotopes in Uranium Oxides during Peroxide Precipitation and Dry Air Calcination

The interaction between uranium and oxygen-containing substrates is nearly ubiquitous within the nuclear fuel cycle. Given the well-known and predictable oxygen stable isotope compositions of atmospheric oxygen and meteoric waters around the world, the use of these isotopes as a potential geolocation or processing signature of uranium compounds has been of interest within the nuclear safeguards community. This study focuses on measuring the oxygen-stable isotope composition of synthetically produced uranium oxides to determine the mechanism and extent of fractionation during materials processing relevant to the nuclear fuel cycle. Here, metastudtite [UO 2 O 2 (H 2 O) 2 ] samples were first produced using water and hydrogen peroxide of a known oxygen isotope composition. This starting material was calcined in dry air at temperatures ranging from 300 °C to 1000 °C for 20 h producing oxides ranging in composition from UO 3 +x (0 ≤ x ≤ 0.5) to U 3 O 8 . In addition, calcinations between 500 and 800 °C were performed at different time intervals to evaluate the rate of isotopic equilibration. The δ 18 O values of water bound to metastudtite were measured by thermogravimetric analysis coupled to isotope ratio infrared spectroscopy (TGA–IRIS). A redesigned fluorination manifold was constructed at the University of Utah and was used to extract the bulk oxygen from precipitated and calcined products using bromine pentafluoride (BrF 5 ). Mineralization water on metastudtite (measured by TGA–IRIS) was closely associated with the aqueous environment of precipitation with a fractionation of +3.5 ± 0.6‰. In contrast, bulk oxygen from metastudtite (measured by fluorination and gas chromatography combined with isotope ratio mass spectrometry) was found to have an inconsistent fractionation with precipitation water. Samples calcined in dry air exhibited a wide range of oxygen isotope compositions which increased from δ 18 O = +1.4 ± 0.9‰ at 300 °C to +17.3 ± 0.9‰ at 1000 °C. This variation in δ 18 O values was a result of oxygen exchange with atmospheric O 2 and was found to be rapid at calcination temperatures greater than 600°C—with equilibration occurring in less than 2 h. These results provide insights into the incorporation and exchange of oxygen isotopes during precipitation and calcination processes comparable to those employed within the nuclear fuel cycle and establish a foundation for future investigations to build upon.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Development towards stable chlorine isotope measurements of astromaterials using the modified Middleton source of an accelerator mass spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35 Cl and 37 Cl. Chlorine isotope variations (reported as δ 37 Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) are documented to exceed 80‰ between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history. The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements. This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ 37 Cl measurements using the modified Middleton ion source of an existing accelerator mass spectrometer. For samples with as little as 1 μg Cl–the equivalent of 2–4 mm 3 of a typical lunar rock sample–the average cathode accuracy is ~1‰. Finally, cathode reproducibility is typically ~1‰ (2σ) for samples with at least 10 μg of Cl, increasing to ~3–6‰ for aliquots with ~1–2 μg Cl, similar to published SIMS results and sufficient to study astromaterials from the Moon, Mars, or 4 Vesta, which have tens of ‰ observed variations.

07 ISOTOPE AND RADIATION SOURCES↗

Preliminary investigation of an uncertainty budget for uranium isotope ratio analysis using a liquid sampling—atmospheric pressure glow discharge—orbitrap mass spectrometer system

The liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source has proven to be an effective analysis tool for making uranium isotope ratio measurements when coupled to high-resolution mass spectrometers, such as the Orbitrap. While previous studies have shown the capabilities of the LS-APGD for isotope ratio determination, a systematic evaluation of the measurement uncertainty of the technique has not been conducted. To this end, the International Standards Organizations (ISO) guidelines to the expression of uncertainty in measurement (GUM analysis) have been applied to generate an uncertainty budget. For this work, a preliminary assessment derived from the GUM analysis was performed. The uncertainty in the instrument blank determination has been identified as a primary factor contributing to measurement uncertainty for the LS-APGD-Orbitrap method. These findings for the specific test case of uranium isotopic analysis will be invaluable in applications across the breadth of isotope ratio mass spectrometry performed on this unique instrumental platform.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk↗

Isotopic Fractionation and Kinetic Isotope Effects of a Purified Bacterial Nitric Oxide Reductase (NOR)

Nitrous oxide (N 2 O) is a serious concern due to its role in global warming and ozone destruction. Agricultural practices account for ~80% of all anthropogenic N 2 O produced in the US, due in large part to the stimulation of microbial denitrification. Stable isotopes are uniquely suited to examine both microbial N 2 O sources and the mechanism of N 2 O biosynthesis through the use of 2 Site Preference (δ 15 N SP ; the difference in δ 15 N between the central and outer N atoms in N 2 O) and kinetic isotope effects (KIEs), respectively. Using trace gas isotope ratio mass spectrometry (TG-IRMS), we determined the δ 15 N, δ 15 N α , δ 15 N β , and δ 18 O of N 2 O produced by a purified cytochrome c nitric oxide reductase (cNOR) from Paracoccus denitrificans. We also calculated δ 15 N SP , the KIEs, and associated isotopic enrichment factors (ε) for N bulk , N α , and N β . A normal isotope effect was observed for bulk 15 N, with a KIE value of 1.0086 ± 0.0009 (ε = -8.6 ± 0.9‰). The isotope effects for both 15 N α and 15 N β were also normal, with position-specific KIEs of 1.0072 ± 0.0010 (ε = -7.2 ± 1.0‰) and 1.0100 ± 0.0010 (ε = -9.9 ± 1.0‰), respectively, and δ 15 N SP values ranged from 0.5 to 8.7‰ with no significant trend as the reaction proceeded. Values of δ 18 O increased with N 2 O production (slope of δ 18 O against [-flnf/(1-f)] = -19.9 ± 1.9‰). We present implications for the mechanism of N 2 O production from cNOR based on our data.

Rivett, Elise D. [Michigan State Univ., East Lansi↗

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗

SPRUCE Sphagnum Phytobiome Responses to Whole Ecosystem Warming and Elevated Atmospheric CO2 in July, 2017-2021

This dataset reports the carbon (C) and nitrogen (N) isotopic composition of Sphagnum moss tissue collected from the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental site within the Marcell Experimental Forest in northern Minnesota, USA. Tissues were collected inside the SPRUCE experimental study plot, where air and peat warming are combined in whole-ecosystem warming treatments, from 2019-2021. Additionally, rates of nitrogen fixation and methane oxidation measured for Sphagnum from 2017, 2019, and 2021. Sphagnum tissue % water content was measured at all timepoints. This dataset was used to conduct analyses within Petro et al (2023). Sphagnum C and N concentrations and 13C and 15N isotopic natural abundance were determined for three replicate Sphagnum tissue samples collected from inside the SPRUCE enclosures in July 2019-2021. Elemental and isotope analyses were conducted at the University of Georgia – Center for Applied Isotope Studies (CAIS; https://cais.uga.edu/). Plant elemental analysis was performed by the micro-Dumas method, while isotopic natural abundance was measured by isotope ratio mass spectrometry. 13C natural abundance is expressed as the per mille (‰) deviation from the Pee Dee Belemnite standard (PDB) 13C:12C ratio (δ13C), while 15N natural abundance is expressed as the ‰ deviation from the N2 atmospheric 15N:14N ratio (δ15N). Rates of nitrogen fixation and methane oxidation were measured using serum bottle incubations performed with Sphagnum collected inside the SPRUCE enclosures in July 2017, 2019, and 2021. Rates were calculated according to the amount of 15N-N2 or 13C-CH4 (methane) incorporated into the Sphagnum tissue or incubation headspace over the 48-hour intion period. In 2017, incubations were performed in growth chambers set to the temperature of the experimental plots during Sphagnum sampling. In 2019 and 2021, the incubations were performed directly inside the experimental plots. The 13C and 15N isotopic natural abundance data and rate measurements presented in this dataset provide insight into the impacts of whole-ecosystem warming and elevated atmospheric carbon dioxide (CO2) on N and C cycling within the Sphagnum phytobiome. This dataset contains two data files in comma-separate values (*.csv) format. Additional metadata are provided: two data dictionaries and a file-level metadata file in comma-separate values (.csv) format and a user guide in PDF (*.pdf) format. Additional datasets on NH4-N availability, porewater concentrations of CH4 and CO2, and Sphagnum groundcover within the SPRUCE experimental plots are available. These are outlined in the Related Datasets section in the user guide.

delta 13 carbon↗

Conifer water use patterns in the East River Watershed, Colorado US, based on stable water isotopes and cellulose isotopes

This data package contains a series of datasets aimed at understanding the seasonal origins of water used by the dominant conifer species, Abies lasiocarpa and Picea engelmannii, in the East River Watershed. There is a distinct difference in the stable isotopic ratio of summer rain and snowpack and thus by tracking the isotopic ratio of the xylem water in trees, it is possible to separate when a tree is using snow vs. summer rain. Following typical protocols, we sampled and extracted water from soils in the "Research Meadow" near Gothic, CO within the East River Watershed through the 2016 growing season. The stable isotopic ratio of these waters were then measured. Using values of the isotopic ratio of precipitation and snowpack from that season, we develop a mixing model to show how the trees transitioned from use of snowpack to summer in late July. We extended the information on the seasonal origins of water from 2016 back until 1980 by using measurements of the isotopic ratio of cellulose from trees in the Research Meadow. The isotopic ratio of tree ring cellulose records a signal both of the Vapor Pressure Deficit at the leaf-atmosphere boundary and also the source water for the trees. We concluded from this extended analysis that the trees underwent transitions between periods where snow was the dominant water source and summer rain was the dominant water source. More details on this analysis can be found in the publication: Persistence and Plasticity in Conifer Water Use Strategies. JGR Biogeoscience. DOI 10.1029/2018JG004845. The dataset specifically includes stable isotope measurements of xylem and soil water for Spruce and Fir trees at the Rocky Mountain Biological Lab's Research Meadow as well as snowpack and precipitation stable isotopes from nearby National Atmospheric Deposition Program sites. Associated meteorological data is included, which is needed to understand the source water for the trees based on the cellulose measurements.This dataset was updated in June 2021 also include intra-ring measurements of the d18O and d13C of cellulose these same species of trees at the Ziegler Reservoir site in Snowmass, CO. These are listed as files: "Interglaciald18OCellulose.csv", "Interglaciald13OCellulose.csv" and "Modernd13CCellulose.csv". The intent of these measurements was to assess whether common conifers (abies and picea) had undergone ecophysiological or ecohydrological changes during the last period in Earth's history was warmer than today, i.e. the last Interglacial (116,000 to 130,000 years ago). This site was chosen because it is a location where subfossil wood from this critical warm period was discovered. We measured the d18O and d13C of the subfossil trees following the same protocol as the modern samples which included chemical extraction of cellulose and isotope ratio mass spectrometry. We found that the trees showed little difference in water use efficiency but utilized more summer rain during the interglacial period. This analysis and detailed methods are provided in the following manuscript: Wetter summers mitigated temperature stress on Rocky Mountain forests during the last interglacial warm period which is in revision at GRL but is available as a preprint here: 10.1002/essoar.10506740.2

54 ENVIRONMENTAL SCIENCES↗