Search NASA⌕ Search

SEARCH · Search NASA

Results for “J1772”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Thermal Evaluation of CCS and NACS Reference Devices and Adapters

It is important for manufacturers of electric vehicle charging connectors, inlets, and adapters to understand the thermal performance of their devices. Various standards, such as SAE J1772, SAE J3400, IEC 62196, UL 2251, and UL 2252, list temperature limits that charging hardware needs to meet. However, there are currently very limited standardized reference devices against which to measure connector performance, and those that do currently exist generally serve charging currents less than 500A. This can make determining whether a charging connector meets the appropriate temperature limits difficult. Additionally, as automakers and charging station suppliers transition from the SAE J1772 CCS charging standard to SAE J3400 NACS, a number of CCS-to-NACS and NACS-to-CCS adapters are entering the market. These devices are being produced both by well-known automakers/equipment OEMs and lesser-known third-party suppliers, across a wide range of price points and construction qualities. Though SAE J3400/1 and UL 2252 lay out standards for adapter construction, performance and overtemperature response, there is no guarantee that any particular adapter will follow these standards and react to overtemperature events appropriately. This work addresses these issues by developing and evaluating a set of CCS and NACS reference inlet devices to validate the performance of charging connectors in the 500-800A range. The work also evaluates the performance of multiple NACS-to-CCS and CCS-to-NACS charging adapters with respect to UL 2252 temperature limits and SAE J3400/1 overtemperature signaling criteria.

33 ADVANCED PROPULSION SYSTEMS↗

Adapter Signaling Evaluations on EVs [Slides]

In case J3400 and J3400/1 define a basic analog signaling approach for DC charging adapters to communicate over-temperature events to both the EV and EVSE. They also require the EV to implement mitigation and corrective actions in cases where the EVSE does not respond to adapter thermal signals. In this study, multiple production vehicles were evaluated for responsiveness to assess field readiness and ensure consistent performance in accordance with the SAE J1772, J3400 and J3400/1 standards. A series of test cases were developed and executed across different vehicles, using an adapter thermal breakout fixture designed by NLR for evaluations. The results revealed notable variations in behavior: some vehicles expected to comply with J1772 were found to be non-responsive under certain conditions. Additionally, while some EV OEMs appear to align with the J3400 standard, discrepancies exist due to its evolving nature, resulting in inconsistent implementation of the latest requirements. These findings highlight the need for alignment within standards organizations to ensure consistent interpretation, encourage compliance, and reduce potential confusion across implementations.

33 ADVANCED PROPULSION SYSTEMS↗

Plug-in Electric Vehicle Charging Response Characterization for Grid Integration: Implications for Smart Charge Management

The rapid expansion of plug-in electric vehicles (PEVs) has created a unique challenge for electrical grids due to their significant power demand. At the same time, PEVs also create a unique opportunity to ease their own burden on the power grid, as they create a growing fleet of distributed energy resources capable of providing grid services such as demand response, frequency regulation, and renewable balancing. For aggregators and grid operators to effectively integrate PEVs into grid management, it is essential to first understand and characterize how they would respond in such situations. This study examines 25 models of PEVs across 25 makes, spanning model years from 2013 to 2025, to characterize their responses to the basic controls used in vehicle-grid integration (VGI): stopping, starting, and modulating the charge rate. Each vehicle was tested in a controlled laboratory setting to evaluate its performance in response to varying the maximum allowable current via the SAE J1772 control pilot signal, as well as its response to wake-up commands outlined in SAE J1772. Results show measurable differences across vehicle makes in the accuracy, latency, and precision with which PEVs respond to changes in ampacity, as well as varying sleep and wake-up behavior. The test results show that all vehicles respond to changes in ampacity, though with varying accuracy, precision, latency, and resolution. Wake-up behavior also differs across makes and models. These findings indicate that effective grid integration strategies must account for these differences. The results provide a foundation for understanding current vehicle behavior and advancing smart-charging methods while also highlighting the need for further testing, broader standardization, and manufacturer collaboration to ensure the successful integration of PEVs into the electrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluations of Connectors, Inlets, and Adapters on Side-Load and Withstand Force

This report examines the mechanical forces that direct current fast charging (DCFC) electric vehicle supply equipment (EVSE) connectors and electric vehicle (EV) inlet ports experience during normal usage. As we witness the fast and growing variety of EVs, charge port locations, and bigger and more powerful EVSE configurations including the SAE J3400 North American Charging Standard (NACS), which has increased the use of adapters with J3400 and J1772 compatibility. These new conditions contribute to increased mechanical forces due to their size, weight and lever arm effect, which creates the need to study and compare these forces to the limits on UL2251 and IEC 62196-1 standards. This report focuses solely on high power DC charging EVSE connectors, EV inlets and adapters for the specific compatibility cases on J3400 with J1772. We first describe the details of the 100N and the 750N side-load evaluations as described in the standards, then present the data obtained by replicating these tests to finally go into more detail on the findings and our recommendations.

100N↗

Development of a Hardware-in-The-Loop Testbed for a Decentralized, Data-Driven Electric Vehicle Charging Control Algorithm

This study presents the design of an electric vehicle (EV)-grid integration (EVGI) hardware test-bed to implement smart EV charging algorithms. Here, the proposed test-bed also allows to create different grid events via flexible integration of other power hardware (e.g., controllable loads and battery energy storage systems) and test their impacts on EV charging. The design uses a real-time digital simulator to realize a complex distribution grid model with primary and secondary networks. A grid simulator physically realizes the selected nodes of the simulated grid to power an actual EV, forming a hardware-in-the-loop (HIL) test setup. The EV-grid integration is demonstrated based on the custom hardware and software implementation of the J1772 charging protocol using dSPACE MicroLabBox, operating as a custom EV Supply Equipment (EVSE). The HIL test-bed features a novel testing platform for accurate implementation and analysis of scalable charging algorithms. To this end, a data-driven, decentralized, model-free charging controller based on the Additive Increase and Multiplicative Decrease (AIMD) algorithm is presented and validated on an EV using the HIL test-bed. We tested the proposed algorithm under various case studies, and presented a comparison study with an existing droop-based, decentralized charging solution. The results showed that the EV successfully performed charging commands generated by the EVSE and regulated its charging power to effectively reduce the system loading caused by high EV penetration.

33 ADVANCED PROPULSION SYSTEMS↗

Optimized V1G and V2G Electric Vehicle Fleet Management and Grid Transaction at Marine Corps Air Station Miramar in San Diego, CA

The overall technical goal of the project was to demonstrate an all-electric bi-directional non-tactical fleet at Marine Corps Air Station (MCAS) Miramar that was integrated and controlled with other distributed energy resources (DERs) (i.e., PV, stationary battery, and building loads) to provide resilience to critical electric loads in the event of grid outages, to minimize charging costs, and to provide economic energy resources to electricity markets. In this project, the specific, technical objectives were: 1. Demonstrate that bi-directional electric vehicles can provide critical complementary services to fixed storage batteries in microgrid applications while performing function as non-tactical vehicles. 2. Demonstrate participation of bi-directional (V2G) and unidirectional (V1G) PEVs for demand management and minimization of charging costs. 3. Demonstrate integration of multiple DERs for grid service participation. US Marine Corps Air Station (MCAS) Miramar in San Diego was the site of this electric vehicle-to-microgrid-utility grid test and demonstration project. Existing microgrid assets in this study included (1) a public works building; (2) a 30-kW rooftop photovoltaic (PV) system and (3) a separate 250 kW carport PV system. In this project, six bi-directional V2G vans were located at the MCAS Miramar’s showcase building-scale microgrid to develop and test technical capabilities that V2G can provide in microgrid applications (e.g., cost reduction and resiliency). These resources provided aggregated demand management and simulated participation in current retail DR programs. The vehicles used in this demonstration were selected because they provided functionality that MCAS Miramar needed, 15 passenger transport and facilities work cargo carrying capacity, and bi-directional charging capability that the research project required. All vehicles in this study were manufactured and distributed by VIA Motors, Inc. There were six vehicles total and each was VIA’s VTRUX eREV V2G model, a modified General Motors Chevrolet 2500 2WD van. Three of the vans were configured as passenger vans and the other three were configured as cargo vans. Each van had an on-board bi-direcrtional inverter/charger, Bel Power Solutions model 350INVCHGT150-120-240-8G nominally rated at +/-15 kW. The VIA van’s charging connector follows the J1772 charging protocol. The bi-directional EVSEs demonstrated in this study were manufactured by Coritech, Inc. Each VGI-80-AC charging station enabled enhanced V2G charging capability to a Clipper Creek CS-100 charging module. The enhanced capabilities included ethernet communication following the SEP2.0 protocol with a distributed energy resource function set and an operator screen displaying real-time SOC, voltage, and current. The VGI-80-AC charging stations are classified as level 2 with a maximum current output of 80 A or effectively 19 kW. The VIA van’s onboard charger limited the charging and discharging power to 15 kW in each direction. A control computer was installed in the EWOC and connected to an existing monitor. The V2G control communication network was a completely stand-alone closed system that did not have any connection to any other networks on the base. A cybersecure remote communication connection was created with a cellular modem, firewall hardware, and a virtual private network configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pull Force Evaluation of CCS Insulated End Caps

Insulated end caps installed on DC pins of Combined Charging System (CCS) inlets have been identified as potential debris sources within electric vehicle supply equipment (EVSE) connectors, increasing the risk of electric shock and fire hazards. Although standards such as IEC 62196-1:2022 specify mechanical pull-force requirements for these end caps, it remains unclear whether these requirements provide adequate robustness under real-world conditions. To address this concern, the National Charging Experience (ChargeX) Consortium's Hardware Task Force conducted evaluations of insulated end caps used in OEM CCS inlets. This study assesses the performance of insulated end caps used in OEM CCS inlets, specifically those installed on DC pins, using the procedures defined in IEC 62196-1:2022 (Section Sign) 26.7 and SAE J3400, supplemented by additional experimental conditioning. To ensure relevance to real-world conditions, NLR collaborated with charging network operators (CNOs) to guide the selection of charging inlet samples. Material analyses of the insulated end cap samples were conducted to confirm that the tested materials reflected the types and properties commonly observed in the field. The selected samples underwent temperature and humidity conditioning followed by pull-force testing to evaluate the end-cap integrity. Although SAE J3400 inlets were not directly tested due to limited diversity in available field data, the underlying end-cap principles between CCS and SAE J3400 are comparable, allowing the study's insights to be relevant to both technologies. Overall, this study provides a structured evaluation framework to inform potential refinements to mechanical pull-force requirements in charging standards.

33 ADVANCED PROPULSION SYSTEMS↗