Search NASA⌕ Search

SEARCH · Search NASA

Results for “Jefferson Lab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Jefferson Lab Positron Program

The Jefferson Lab Polarized Electrons for Polarized Positrons (PEPPo) experiment demonstrated that it is possible to make polarized positrons with the polarized electron beam at CEBAF. Jefferson Lab is now looking to develop a dedicated positron source that will be able to feed the CEBAF accelerator with polarized positrons and deliver up to 11 GeV positrons to the experimental halls. I will present the plans for this new source as well as present an overview of the scientific program that is planned with this new source.

Higinbotham, Douglas↗

Signal Extraction and Simulations for n -> p^0 y y and n -> p+p-e+e- Decays at the Jefferson Lab Eta Factory

The Jefferson Lab eta Factory (JEF) began acquiring data in early 2025. The experiment aims to give insight into the connection between Dark Matter physics models and the Standard Model by investigating rare decay processes of n and n' mesons. Several other physics motivations are also a key factor in the experiment, such as probing C and/or P violation and aspects of chiral perturbation theory. For these purposes, the forward calorimeter of the GlueX experiment in Jefferson Lab was upgraded so that it provides greater positional and energy resolution. Understanding physics-motivated cuts and background removal methods is of great importance to achieving JEF goals. Several methods have been implemented to obtain invariant mass plots for the “golden” channel of interest ¿ ¿ p0¿¿, while channels such as ¿ ¿ p+p-e+e- open a promising window into CP-violating physics. This thesis work shows a sig nificant background reduction in rare decay channels of interest, asymmetry factors comparable to recent experimental measurements, an evaluation on which analysis cuts to use after data acquisition and the likelihood of probing specific rare ¿ decays. Despite background rejection from obstructing decay channels, much remains to do to extract the p0¿¿ final-state. The asymmetry between the pion and lepton planes looks promising for p+p-e+e-; simulations show that the asymmetry is consistent with zero (no instrumental asymmetry), and the next step should include generators that model the physics of the asymmetry. This thesis work may help in the effort of probing CP-violating physics or solving the mysteries between “beyond-Standard Model” and our current understanding of physics.

Oresic, Stjepan [Univ. of Regina, SK (Canada)]↗

Status of the Jefferson Lab Eta Factory (JEF) experiment

The Jefferson Lab Eta Factory (JEF) experiment is an experiment running in Hall D at Jefferson Lab that focuses on studying the decays of the ¿ meson. These decays provide a rich laboratory for searching for new charge conjugation violating / parity conserving (CVPC) processes, looking for hints of Beyond Standard Model physics, and probing higher order terms in Chiral Perturbation Theory. The flagship channel is the rare decay ¿ ¿ p0¿¿, the measurement of which required an upgrade to the existing equipment in Hall D. The experiment uses the GlueX detector, a fixed-target large acceptance spectrometer based on a solenoid magnet containing drift chambers for tracking charged particles and a lead-scintillator barrel calorimeter in the central region and an array of 4 × 4 × 45 cm3 lead glass blocks in the forward region for detecting neutral particles. During the last two years the inner 80×80 cm2 region of the forward calorimeter has been replaced by an array of 2 × 2 × 20 cm3 lead tungstate crystals, which provide factors of two improvement in energy and position resolution. The first round of data taking with this configuration took place this year. A first look at the data will be presented.

Taylor, Simon [Thomas Jefferson National Accelerat↗

Experiments at Jefferson Lab

This chapter presents experiments conducted at Thomas Jefferson National Accelerator Facility (Jefferson Lab), a U.S. Department of Energy national laboratory in Newport News, Virginia. There, physicists exploring the nature of matter make use of the Continuous Electron Beam Accelerator Facility (CEBAF), a DOE Office of Science user facility that enables the research of more than 1,650 scientists worldwide. CEBAF’s precise electron beams can reach energies up to 12 billion electron-volts and exhibit high degrees of polarization. Jefferson Lab’s first experiment began taking data in 1995. Since then, the facility has become a world leader in the study of quantum chromodynamics. Today, experiments are carried out simultaneously in four experimental halls, each with specialized capabilities. The primary instruments in use are focusing or large-acceptance magnetic spectrometers, many of which feature superconducting elements. Jefferson Lab’s physics program provides unprecedented insight into the particles and forces that shape the visible universe.

Achenbach, Patrick [Thomas Jefferson National Acce↗

Potential for tensor polarized deuterons in Hall D at Jefferson lab

Hall D at Jefferson lab is an ideal place to install a polarized deuteron target which can be “tensor polarized”, allowing the separation of the spin states m = 0, ±1 or the measurement of tensor asymmetries. The bremsstrahlung photon beam with 3 - 12 GeV endpoint provides very little heating or radiation damage compared to an electron beam, allowing the target to be run in frozen spin mode. Adiabatic fast passage spin manipulations can then be used to greatly enhance the population of the m = 0 spin state of the deuteron. Coherent photoproduction of ρ mesons from deuterium is sensitive to double-scattering at high momentum transfer and in the m = 0 spin state an additional sensitivity at intermediate momentum transfer opens up. In conclusion, we propose a frozen spin target for Hall D and the measurement of ρ photoproduced coherently from the deuteron as a flagship measurement.

43 PARTICLE ACCELERATORS↗

μRWELL detector developments at Jefferson Lab for high luminosity experiments

One of the future plans at Jefferson Lab is running electron scattering experiments with large acceptance detectors at luminosities > 10^37 cm^−2 s^−1. These experiments allow the measurements of the Double Deeply Virtual Compton Scattering (DDVCS) reaction, an important physics process in the formalism of Generalized Parton Distributions, which has never been measured because of its small cross-section. The luminosity upgrade of CLAS12 or the SOLID detector makes Jefferson Lab a unique place to measure DDVCS. One of the important components of these high luminosity detectors is a tracking system that can withstand high rates of ≈ 1MHz/cm2. The recently developed Micro-Resistive Well (𝜇RWELL) detector technology is a promising option for such a tracking detector by combining good position resolutions, low material budget with simple mechanical construction, and low production costs. In this proceeding, we will discuss recent developments and studies with 𝜇RWELL detectors at Jefferson Lab for future upgrades of the CLAS12 detector to study the DDVCS reaction.

Hauenstein, Florian↗

Jefferson Lab Injector Beamline Upgrade

The Jefferson Lab injector beamline upgrade was completed in 2023, with vacuum improvements throughout the region. I will discuss the effects of the vacuum improvement on photocathode lifetime, the particulate control measures instituted to protect SRF accelerating cavities, and the latest JLab extreme high vacuum gun installation.

Stutzman, Marcy↗

The Future Polarized Target Program at Jefferson Lab

Polarized targets have played a crucial role in Jefferson Lab's exploration of nuclear structure over the past four decades. The three original experimental halls have seen 19 separate installations of polarized solid or gas targets for use in the particle physics scattering experiments, and this trend will continue in the next decade. Five polarized target systems are in preparation for use at JLab in the coming years. Hall B will see the use of two solid polarized targets, one longitudinally polarized to the beam, the other transversely, as well as a novel 3He gas polarized target. In Hall C, new experiments will augment the tensor polarization in dynamically polarized solids. Plans are under development to bring a polarized solid target to Jefferson Lab's photon beam hall, Hall D, for the first time. To support these efforts, the JLab polarized target group is building a test laboratory to develop dynamic nuclear polarization techniques, as well as an apparatus to irradiate target material using electrons from JLab's injector test facility. In this talk, we will explore the development progress and plans for each of these efforts.

Maxwell, James [Thomas Jefferson National Accelera↗

Using AI to predict calibration constants for the central drift chamber in GlueX at Jefferson Lab

The AI for Experimental Controls project team at Jefferson Lab has developed an AI system to control and calibrate a large drift chamber system in near-real time. The AI system will monitor environmental and experimental variables to recommend voltage settings that maintain consistent dE/dx gain and optimal resolution throughout the experiment. At present, calibrations are performed after data have been recorded and require a considerable amount of time and attention from experts. The calibrations currently require multiple iterations and depend on accurate tracking information. Our approach uses environmental data, such as atmospheric pressure and gas temperature, and beam conditions, such as the flux of incident particles, as inputs to a Gaussian Process Regression (GPR) model. For the data taken during the GlueX 2020 run period, the GPR is able to predict the existing gain correction factors to within 3.5%. This talk will briefly describe the development, testing, and future plans for this system at Jefferson Lab.

Jeske, Torri↗

Status of the PrimEx $\eta$ experiment at Jefferson Lab

The GlueX detector in the experimental Hall D at Jefferson Lab offers a unique opportunity to perform a measurement of the decay width of eta mesons through the Primakoff effect. The experiment complements the physics program at Jefferson Lab on measuring the decay width of light pseudoscalar mesons via the Primakoff process. The goal of the experiment is to measure differential cross sections of eta mesons at forward angles using a beam of tagged photons incident on a liquid 4He target, which will be used for the extraction of the decay width. This measurement is vital for understanding fundamental properties like the ratios of the light quark masses and the eta - eta' mixing angle, and will provide an important test of chiral symmetry breaking in QCD. Our experimental results will help reduce uncertainties on partial widths of all other eta decays. The experiment collected data during three physics runs between 2019 and 2022. We will give an overview of the PrimEx eta experiment and the current status of our data analyses. We will also discuss the feasibility of conducting future Primakoff measurements in light of the recent upgrade of the GlueX forward calorimeter and the potential accelerator energy upgrade to 22 GeV.

Somov, Alexander↗

Summary of Jefferson Lab LDRD on FFA@CEBAF Beam Dynamics Simulations

As Thomas Jefferson National Accelerator Facility (Jefferson Lab) looks toward the future, we are considering expanding our energy reach by using Fixed-Field Alternating Gradient (FFA) technology. Significant efforts have been made to design a hybrid accelerator which combines conventional recirculating electron LINAC design with permanent magnet-based FFA technology to increase the number of beam recirculations, and thus the energy. In an effort to further this progress, Jefferson Lab awarded a Laboratory Directed Research and Development (LDRD) grant to focus not on the design, but on detailed simulations of the designs created by the larger collaboration. This document will summarize the work performed during this LDRD, and direct the reader to other proceedings which describe elements of the work in greater detail.

Deitrick, K.↗

Recent developments and operation of polarized photocathodes at Jefferson Lab

Spin-polarized electron sources are critical to a wide range of accelerator-based applications for nuclear and particle physics. At Thomas Jefferson National Accelerator Facility, they play a central role in delivering high-quality polarized beams for precision nuclear physics experiments and next-generation parity-violation measurements, where stringent control of systematic uncertainties is essential. These sources are also expected to be key components of other initiatives, including the Electron-Ion Collider and the potential future positron capabilities at Jefferson Lab. In this talk, I will present ongoing research and development efforts at Jefferson Lab focused on the design, fabrication and optimization of spin-polarized photocathodes. This includes growth using molecular beam epitaxy (MBE) or metal-organic chemical vapor deposition (MOCVD), along with detailed characterization of their performance metrics, such as quantum efficiency (QE), electron spin polarization and QE anisotropy, all of which are increasingly important metrics for polarized electron sources at Jefferson Lab and the Electron-Ion Collider. Strategies to mitigate QE anisotropy, which is critical for reducing helicity-correlated beam asymmetries in precision experiments such as MOLLER will be highlighted. Finally, I will present recent efforts aimed at improving the operational lifetime of spin-polarized photocathodes in injector environments, particularly under high-voltage conditions in DC electron guns. These developments are essential for enabling reliable, high-performance operation of polarized sources for current and future accelerator programs.

Kachwala, Alimohammed [Thomas Jefferson National A↗

Cold compressor performance and energy consumption improvements at Jefferson Lab’s Central Helium Liquefiers

Abstract Jefferson Lab operates two central helium liquefiers (CHLs) which both utilize full cold compression from the saturation pressure at operating temperature (approximately 2.1 K) to just over atmospheric pressure. The original plant, CHL1, was recently outfitted with a replacement subatmospheric cold box (SC1R) containing state-of-the-art cold compressor technology, while the newer plant, CHL2, uses an older cold compressor system. In both cases, the heat of compression is absorbed at low temperature at the expense of electrical power consumed by the warm compressors. Due to the superior efficiency and turndown capabilities of SC1R, a new operating mode has been identified for CHL1 in which the required number of operating warm compressors is reduced by one. A cost-based method for optimizing cold compressor stability and efficiency has been developed and applied to CHL2, improving its turndown and lowering the warm compressor discharge pressure. As a result of these efforts, power consumption of the combined CHLs during normal operations has been reduced by nearly 10%, or a total of 650 kW. The observed performance of CHL1 with SC1R, as well as the cold compressor optimization method, leading to this improved energy consumption rate will be discussed in detail.

Mastracci, B [Thomas Jefferson National Accelerato↗

Petabyte Class Storage at Jefferson Lab (CEBAF)

By 1997, the Thomas Jefferson National Accelerator Facility will collect over one Terabyte of raw information per day of Accelerator operation from three concurrently operating Experimental Halls. When post-processing is included, roughly 250 TB of raw and formatted experimental data will be generated each year. By the year 2000, a total of one Petabyte will be stored on-line. Critical to the experimental program at Jefferson Lab (JLab) is the networking and computational capability to collect, store, retrieve, and reconstruct data on this scale. The design criteria include support of a raw data stream of 10-12 MB/second from Experimental Hall B, which will operate the CEBAF (Continuous Electron Beam Accelerator Facility) Large Acceptance Spectrometer (CLAS). Keeping up with this data stream implies design strategies that provide storage guarantees during accelerator operation, minimize the number of times data is buffered allow seamless access to specific data sets for the researcher, synchronize data retrievals with the scheduling of postprocessing calculations on the data reconstruction CPU farms, as well as support the site capability to perform data reconstruction and reduction at the same overall rate at which new data is being collected. The current implementation employs state-of-the-art StorageTek Redwood tape drives and robotics library integrated with the Open Storage Manager (OSM) Hierarchical Storage Management software (Computer Associates, International), the use of Fibre Channel RAID disks dual-ported between Sun Microsystems SMP servers, and a network-based interface to a 10,000 SPECint92 data processing CPU farm. Issues of efficiency, scalability, and manageability will become critical to meet the year 2000 requirements for a Petabyte of near-line storage interfaced to over 30,000 SPECint92 of data processing power.

Chambers, Rita↗

The SHMS 11 GeV/c spectrometer in Hall C at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) has been built for Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). With a momentum capability reaching 11 GeV/ c , the SHMS provides measurements of charged particles produced in electron-scattering experiments using the maximum available beam energy from the upgraded Jefferson Lab accelerator. The SHMS is an ion-optics magnetic spectrometer comprised of a series of new superconducting magnets which transport charged particles through an array of triggering, tracking, and particle-identification detectors that measure momentum, energy, angle and position in order to allow kinematic reconstruction of the events back to their origin at the scattering target. The detector system is protected from background radiation by a sophisticated shielding enclosure. The entire spectrometer is mounted on a rotating support structure which permits measurements to be taken with a large acceptance over laboratory scattering angles from 5.5° to 40°, thus allowing a wide range of low cross-section experiments to be conducted. Finally, these experiments complement and extend the previous Hall C research program to higher energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine Learning for Optimized Polarization at Jefferson Lab

Polarized cryo-targets and polarized photon beams are widely used in experiments at Jefferson Lab. Traditional methods for maintaining the optimal polarization involve manual adjustments throughout data taking by human shift takers. This may introduce some level of inconsistency simply due to the wide variety of experience and expertise of the shift takers themselves. Implementing machine learning-based control systems can improve the stability of the polarization without relying on human intervention. The cryo-target polarization is influenced by temperature, microwave energy, the distribution of paramagnetic radicals, as well as operational conditions including the radiation dose. Diamond radiators are used to generate linearly polarized photons from a primary electron beam. The energy spectrum of these photons can drift over time due to changes in the primary electron beam conditions and diamond degradation. As a first step towards automating the continuous optimization and control processes, uncertainty aware surrogate models have been developed to predict the polarization based on historical data. This talk will provide an overview of the use cases and models developed, highlighting the collaboration between data scientists and physicists at Jefferson Lab.

Jeske, Torri [Thomas Jefferson National Accelerato↗

Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment— Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)—requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). Finally, this article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The "Measurement of Lepton-Lepton Electroweak Reaction" (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. These magnets generate the magnetic field needed to separate incident beam electrons scattered from target electrons (Møller scattering) and protons (elastic e-p scattering) within a liquid hydrogen target. Here, this paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗