Search NASA⌕ Search

SEARCH · Search NASA

Results for “KVue”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

SU-F-BRE-10: Methods to Simulate and Measure the Attenuation for Modeling a Couch Top with Rails for FFF Treatment Delivery On the Varian Edge Linac

Purpose: To measure attenuation for modelling of the KVue Couchtop for 6X and 10X FFF SRS/SBRT treatment Methods: Treatment planning simulation studies were done using 6X FFF beams to estimate the dosimetric impact of KVue couchtops (including the Q-Fix IGRT [carbon fiber] and Calypso [nonconductive Kevlar material]) with a structure model obtained from a research workstation (Eclipse, advanced planning interface (API) v13). Prior to installation on the Varian Edge linac, the couchtop along with (Kevlar) rails were CT scanned with the rails at various positions. An additional scan with the couchtop 15cm above the CT table top was obtained with 20cm solid water to facilitate precised/indexed data acquisition. Measurements for attenuation were obtained for field sizes of 2, 4 and 10 cm{sup 2} at 42 gantry angles including 6 pairs of opposing fields and other angles for oblique delivery where the beams traversed the couchtop and or rails. The delivery was fully automated with xml scripts running in developer mode. The results were then used to determine an accurate structure model for AAA (Eclipse v11) planning of IMRT and RapidArc delivery. Results: The planning simulation relative dose attenuation for oblique entry was not significantly different than the Exact IGRT or BrainLab iBeam couch except that the rails added 6% additional attenuation. The relative attenuation measurements for PA, PA (rails: inner position), oblique, oblique (rails: outer position), oblique (rails: inner position) were: −2.0%, −2.5%, −15.6%, −2.5%, −5.0% for 6X FFF and −1.4%, −1.5%, −12.2%, − 2.5%, −5.0% for 10X FFF with slight decrease in attenuation versus field size. A Couch structure model (with HU values) was developed. Calculation compared to measurement showed good agreement except for oblique (rails: outer position) where differences approached a magnitude of 6%. Conclusion: A model of the couch structures has been developed accounting for attenuation for FFF beams.

07 ISOTOPE AND RADIATION SOURCES↗

Enhanced Proton Therapy: PPAS

The supplier adjusted the process for manufacturing the Short Head Pod section of the Modular Patient Support System in an attempt to eliminate the voids and discontinuities that prevented them from passing the shoot-through clinical requirements, critical to the use of these parts for patient treatment. The remanufactured unit, while an improvement over the previously supplied unit, it still was unable to meet the stringent shoot-through clinical requirements as tested by the LLUMC Medical Physics Laboratory. The vendor was unable to refine the process further, requiring the team to seek alternative solutions. A new replacement, the KVue system provided by Q-Fix, was evaluated by the LLUMC team and found to provide the desired functionality. The remaining funding from this grant was utilized to purchase components of this new system for patient immobilization on the robotic Precision Patient Alignment System.

99 GENERAL AND MISCELLANEOUS↗

SU-E-T-655: Quantifying the Dosimetric Characteristics of a Calypso Compatible Radiotherapy Treatment Couch with Angular Transmission Functions

Purpose: To quantified the dosimetric characteristics of a Calypso compatible radiotherapy couch using continuously scanned transmission factor as a function of gantry angle. Methods: Radiation dose as a function of gantry angle was measured with an ionization chamber at the center of a 30 cm diameter cylindrical phantom placed on Qfix kVue Calypso compatible couch. A 3-D scanner was employed to continuously scan the dose during an arc rotation delivery. Nearly continuous transmission curves of 0.03° step size were obtained from IEC gantry angle 90° to180° for 6 MV and 15 MV photon beams at three couch longitudinal positions (due to longitudinally non-uniform shape of the couch rails) with rails both at the center and on sides. The transmission curves were evaluated to assess the attenuation by the couch. They were also compared to those of a carbon fiber couch top. Results: The scanned transmission curves of the Calypso comptible couch showed fine details of the couch transmission as a function of gantry angle. The attenuation by the couch varied from 2.4% to 12.9% for the 6 MV photo beam and from 1.8% to 8.9% for the 15 MV photon beam depending on the gantry angle. The attenuation by the flat couch top is only approximately 2 to 3%, but by the rail is much more significant. Because the rails are not uniformly shaped in the longitudinal direction, attenuation by the rail for the same gantry angle varied with the rail longitudinal position. The transmission curves of the carbon fiber couch top are nearly identical to those of the Calypso compatible couch top. Conclusion: The Calypso compatible couch attenuates radiation by 2.4%–12.9% and 1.8%–8.9% for 6 MV and 15 MV photon beams, respectively. The attenuation by the rails is much more significant than the flat couch top.

61 RADIATION PROTECTION AND DOSIMETRY↗

Poster - 34: Clinical Implementation of Prone Breast Treatment

Purpose: Prone breast treatment is used to reduce acute and late toxicities for large or pendulous breast patients. This study developed and implemented the clinical workflow of prone breast radiotherapy treatment. Methods: Varian kVue Access360™ Prone Breast Couchtop was used as prone breast board. The treatment planning (TP)is performed in Eclipse TP system. TP comparisons between supine deep inspiration breathing hold (DIBH) and prone breast; prone forward field-in-field (FinF) planning and inverse IMRT planning were performed and discussed. For the daily setup, breast coverage was assessed in the room using light field and MV imaging was used at day 1 and weekly. Results: The first ten patients are CT scanned and planned both supine and prone. The coverage was all excellent for supine DIBH plan and prone breast plan. The plan in the prone position demonstrated improvements in lung sparing comparing to the DIBH plan. Both forward FinF plan and inverse IMRT plan achieved acceptable coverage of the breast, and heart dose is comparable. Considering the daily setup variations and MLC leakage, forward FinF plan was recommended for routine clinical use. The procedure has been tested in phantom and patients were treated clinically. Conclusions: Prone breast irradiation has been advocated for women with large pendulous breasts in order to decrease acute and late toxicities. The workflow for prone breast radiation therapy has been developed and the technique is ready to treat patients.

60 APPLIED LIFE SCIENCES↗