Search NASASearch

SEARCH · Search NASA

Results for “LAUNCH WINDOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

SpecFIDLER User Manual (Software V.2.6.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Transient Terahertz Oscillations During Photoinduced Polarization Topology Reconfiguration in Ferroelectric Superlattices

Terahertz resonances embedded in crystalline heterostructures could close a spectral gap between conventional electronics and photonics while opening new windows on non-equilibrium lattice dynamics. We show that femtosecond optical screening of the depolarization field in epitaxial PbTiO3/SrTiO3 superlattices launches a collective polar mode that oscillates near 1 THz and coherently spans the entire mini-Brillouin zone. Wave-vector-resolved pump–probe X-ray diffraction resolves a nearly dispersion-less oscillation at 0.87 THz and 0.94 THz at the zone boundary and zone center, respectively, persisting for ~2.5 ps, corresponding to a weakly damped resonance. Dynamical phase-field simulations reveal the origin of the mode to mesoscopic rotation of closure-domain textures during the photo-excited transition from an unscreened to a screened electrostatic state. Varying the PbTiO3 and SrTiO3 ratio tunes the mode frequency continuously from 0.9 to 1.4 THz, providing a quantitative design rule for frequency-selectable THz oscillators in ferroelectric heterostructures. By coupling nanoscale polarization reconfiguration to long-wavelength coherent dynamics, this work establishes depolarization-field engineering to topology-driven THz functionality and expanding the landscape of collective lattice dynamics.

Sri Gyan, Deepankar [Univ. of Wisconsin, Madison,

PDV Sensitivity [Slides]

The concept of PDV sensitive is not new. But we tend not to discuss sensitivity in a rigorous, quantified way. That should change. Indeed there is a natural definition, which is just the energy of light from the target within the analysis window that gives a SNR of 10 in the frequency domain. Systems designers, diagnostic engineers, and operators should use the language of sensitivity: (1) Absolute sensitivity: nW * ns; (2) Launch power: mW or dBm; (3) Relative surface return: dB; (4) Relative sensitivity: dB * ns. This will help us design better systems, choose the correct system for the job, maintain our systems, and tune our systems.

47 OTHER INSTRUMENTATION

X-Ray Imaging and Spectroscopy Mission

The X-Ray Imaging and Spectroscopy Mission (XRISM) is a joint mission between the Japan Aerospace Exploration Agency (JAXA) and the National Aeronautics and Space Administration (NASA) in collaboration with the European Space Agency (ESA). In addition to the three space agencies, universities and research institutes from Japan, North America, and Europe have joined to contribute to developing satellite and onboard instruments, data-processing software, and the scientific observation program. XRISM is the successor to the ASTRO-H (Hitomi) mission, which ended prematurely in 2016. Its primary science goal is to examine astrophysical problems with precise, high-resolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. It carries a 6 × 6 pixelized X-ray microcalorimeter on the focal plane of an X-ray mirror assembly (Resolve) and a co-aligned X-ray CCD camera (Xtend) that covers the same energy band over a large field of view. XRISM utilizes the Hitomi heritage, but all designs were reviewed. The attitude and orbit control system was improved in hardware and software. The spacecraft was launched from the JAXA Tanegashima Space Center on 2023 September 6 (UTC). During the in-orbit commissioning phase, the onboard components were activated. Although the gate valve protecting the Resolve sensor with a thin beryllium X-ray entrance window was not yet opened, scientific observation started in 2024 February with the planned performance verification observation program. The nominal observation program commenced with the following guest observation program beginning in 2024 September.

Astronomy and AstroPhysics

Development and preliminary results of 270 GHz microwave forward scattering diagnostic system on the experimental advanced superconducting tokamak (EAST)

To measure localized (intermediate, high) poloidal wavenumber electron density fluctuations, a tangential millimeter-wave collective scattering system has been designed and successfully developed on the experimental advanced superconducting tokamak (EAST). This innovative system employs a 270 GHz mm-wave probe beam, emitted from the mid-plane of Port K and directed towards Port P after passing through a combination of two in-vessel mirrors. Here these two ports are located on the EAST device’s midplane and are 110° apart. The downward scattered signals pass through two in-vessel mirrors, and exit through the P window. The received multi-channel separated scattering signals are arranged along the poloidal direction. This optical arrangement makes the monitored turbulent wave number is poloidal dominant and up to 40 cm −1 . The tangential microwave scattering scheme enables this diagnostic to monitor local density fluctuations, with typically a radial spatial resolution △ R = 5 cm, and a wavenumber resolution of △ k = 0.4 cm −1 . The scattering system underwent comprehensive laboratory testing in 2023, with installation finalized in 2024. The system features steerable launch and receiver optics, allowing remote control to position the scattering volume from normalized radius ρ –0 to the pedestal region on a shot-by-shot basis. Effective experimental data, characterized by distinct off-center spectral peaks, have been successfully obtained in neutral beam-heated plasmas on EAST. The beam tracing forward modeling has been employed for experimental data interpretation. The advanced millimeter-wave scattering system provides fluctuation measurement capability from ion temperature gradient to electron temperature gradient scale on low field side. Preliminary experimental density fluctuation data have been successfully obtained in neutral beam-heated plasmas on EAST. The localized measurement will be used for kinetic turbulence transport numerical simulation validation.

high-k collective scattering

Super-resolution stimulated X-ray Raman spectroscopy

Propagation of intense X-ray pulses through dense media has led to the observation of phenomena such as atomic X-ray lasing, self-induced transparency and stimulated X-ray Raman scattering (SXRS)4. SXRS has been long predicted as a means to launch and probe valence-electron wavepackets and as a building block for nonlinear X-ray spectroscopies. However, experimental observations of SXRS to date have not provided spectroscopic information, and theoretical modelling has largely implemented hard-to-realize phase-coherent attosecond pulses. Here we demonstrate SXRS with spectroscopic precision, that is, detection of valence-excited states in neon with a near Fourier-limited joint energy–time resolution of 0.1 eV–40 fs. We used a new covariance analysis between statistically spiky broadband incident X-ray and scattered X-ray Raman pulses. Using 18,000 single shots, we beat not only the incident (about 8 eV) bandwidth but also the approximately 0.2 eV instrumental energy resolution, thus creating super-resolution conditions, in analogy to super-resolved fluorescence microscopy. Our experimental results, supported by ab initio propagation simulations, reveal the competition between lasing in the ion and stimulated Raman scattering in the neutral. We demonstrate enhanced signal collection efficiency and a broad excitation window, surpassing spontaneous Raman efficiencies by orders of magnitude. This stochastic SXRS approach represents a first step towards tracking elementary events that determine chemical outcomes.

nonlinear x-ray spectroscopy