At least 19 records

DEMONSTRATION OF MULTI-PHYSICS EVALUATION OF FUEL ROD BURST PROBABILITY WITH BURNUP EXTENSION UNDER LBLOCA CONDITIONS

Extending the fuel discharge burnup level, e.g., from the current limit of rod averaged discharge burnup limit of 62 GWD/MT to a proposed new limit of 75 GWD/MT, can provide significant economic benefits to the current fleet of operating light water reactors (LWRs). It allows for longer operating cycles and improved resource utilization. The major economic gain of longer operating cycles is attributable to the increased capacity factor resulting from decreased refueling time as a fraction of total operating time, as well as fewer assemblies to be discharged for a given amount of energy produced. The main licensing challenges for higher burnup fuel are to ensure fuel rod safety under design basis accident conditions, especially under large-break loss-of-coolant accident (LBLOCA) and reactivity insertion accident (RIA). In this work, two-year cycle core design for a typical 4-loop pressurized water reactor (PWR) is performed with enrichment increased up to 6% and burnup extended to 75 GWD/MT. The fuel rod burst potential evaluations under large-break loss-of-coolant accident (LBLOCA) conditions are subsequently performed using the multi-physics best estimate plus uncertainty analysis framework LOTUS (LOCA Toolkit for the U.S. LWRs) and the preliminary results are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Statistical and sensitivity analysis of failing rods in EPR LBLOCA

A statistical fuel failure analysis procedure has been developed, and is now applied in full scale to a large break loss-of-coolant accident (LBLOCA) scenario in EPR-type nuclear power plant. The goal is to statistically determine the number of failing fuel rods. It is also important to bring out the underlying causes for rod failures, and therefore a sensitivity analysis procedure for the preceding complex calculation chain is outlined and adopted. In order to produce a statistically reliable estimation on the number of failing rods, a large number of simulations are required. In the analysis, single rods are simulated with the coupled fuel performance - thermal hydraulics code FRAPTRAN-GENFLO. The statistically varied factors are divided into global and local by their range of influence. Transient thermal hydraulic and power history boundary conditions and model parameters are global and affect all the rods. Fuel rod manufacturing parameters and other rod position related factors are local and are related to a certain rod. The number of global scenarios is 59 as dictated by the Wilks' formula, and 1000 randomly sampled rods are simulated in each scenario. The thermal hydraulic and transient power boundary conditions for the fuel performance code are calculated with a statistical version of the system code APROS. The steady-state irradiation histories are simulated with FRAPCON, and the steady-state power histories used as boundary conditions for FRAPCON are obtained from SIMULATE calculations. Thus, a multistage calculation chain is required to consolidate the procedure. As an outcome, in the worst global scenario, 1.4% of the simulated rods failed. It can be concluded that the Finnish safety regulations, i.e. max. 10% of the rods allowed to fail, are met. In order to find out which input parameters have significance to the outcome of the analysis, a sensitivity analysis is done. At the moment, only the worst global scenario is considered but later on it is possible to include also the sensitivities of the global factors. Due to complexity of the existing data, first the relevant input parameters for the sensitivity analysis have to be specified. Data visualization with a cobweb graph is used for the screening. Then, selected sensitivity measures are calculated between the chosen input and output parameters. The sensitivity indices calculated are the Borgonovo's delta measure, the first order Sobol sensitivity index, and squared Pearson correlation coefficients. The first mentioned is a novelty in this context. As an outcome, the most relevant parameters with respect to the cladding integrity were determined to be the decay heat power during the transient, the thermal hydraulic conditions in the rod's location in the reactor, and the steady-state irradiation history of the rod as represented in this analysis by the rod burnup. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Plant-Level Scenario-Based Risk Analysis for Enhanced Resilient PWR – SBO and LBLOCA

This report documents the activities performed during the FY2018 for the DOE Light Water Reactor Sustainability (LWRS) Program, Risk-Informed System Analysis (RISA) Pathway, Enhanced Resilient Plant (ERP) Systems research. The purpose of the RISA Pathway research and development is to support plant owner-operator decisions with the aim to improve the economics, reliability, and maintain the high levels of safety of current nuclear power plants over periods of extended plant operations. The concept of ERP refers to the combinations of Accident Tolerant Fuel (ATF), optimal use of Diverse and Flexible Coping Strategy (FLEX), enhancements to plant components and systems, and the incorporation of augmented or new passive cooling systems, as well as improved fuel cycle efficiency. The objective of the ERP research effort is to use the RISA methods and toolkit in industry applications, including methods development and early demonstration of technologies, in order to enhance existing reactors safety features (both active and passive) and to substantially reduce operating costs through risk-informed approaches to plant design modifications to the plant and their characterization. There are two main focus areas in FY2018 for the ERP R&D efforts. One is to evaluate the risk impact brought by the ATF designs and FLEX in the selected accident scenarios. The other is to investigate various approaches to accomplish the ERP research objective, i.e., use RISA methods and toolkit to enhance existing reactors safety features and reduce plant operating costs.

99 GENERAL AND MISCELLANEOUS↗

Sensitivity Analysis of Lbloca In Response To 10 Cfr50.46c New Rulemaking

The Nuclear Regulatory Commission (NRC) is proposing a new rulemaking on emergency core system/loss-of-coolant accident (LOCA) performance analysis. In the proposed rulemaking, designated as 10 CFR 50.46c, the US NRC puts forward an equivalent cladding oxidation criterion as a function of cladding pre-transient hydrogen content. The proposed rulemaking imposes more restrictive and burnupdependent cladding embrittlement criteria; consequently more fuel rods need to be analyzed under LOCA conditions to maintain the safety margin, in contrast to the current practice with which only one hot rod needs to be analyzed. New multi-physics analysis methods are required to provide a thorough characterization of the reactor core in order to identify the locations of the limiting rods and quantify safety margins under LOCA conditions. The U.S. DOE’s Light Water Reactor Sustainability (LWRS) Program has initiated a project to develop multi-physics analytical capabilities, called LOTUS, to support the industry in the transition to the proposed rule. An approach to uncertainty quantification and sensitivity analysis with LOTUS was developed. A typical four-loop PWR plant model was developed and simulated by RELAP5-3D with inputs generated from core design and fuel performance analyses, and uncertainty quantification and sensitivity analysis were performed with seventeen uncertain input parameters. The maximum equivalent cladding reacted ratio (ECRR) and peak clad temperature ratio (PCTR) were selected as the figures of merit (FOM). Pearson, Spearman, partial correlation coefficients, and Sobol indices were considered for all of the figures of merit in the sensitivity analysis.

10CFR50.46c↗

Sensitivity Analyses of Natural Convection in the AP1000 Passive Containment Cooling System Following LBLOCA Using CFD

The AP1000 power plant has implemented multiple layers of passive safety systems to enhance reactor safety and ensure system integrity during postulated scenarios, such as loss of coolant accident (LOCA) and main steam line break (MSLB). Among these, the passive containment cooling system (PCCS) is a safety-related system designed to prevent the containment from exceeding the design limits of both pressure and temperature following a postulated design basis accident, by transferring heat from the steel containment vessel to the atmosphere. During LOCA, natural air convection plays a vital role in removing heat from the steel containment vessel to the atmosphere. This is integrated with the condensate film from the Passive Containment Cooling Water Storage Tank (PCCWST). Air natural convection is also the only heat removal mechanism after the dry-out of the PCCWST and during the loss of shutdown decay heat removal (LOSDHR) event. Therefore, it is essential to investigate the thermal hydraulics behavior of the containment under transient conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT model developed to analyze the impact of different parameters, such as air relative humidity, air temperature, and steel containment temperature, on the natural convection capability to remove the decay heat following LOCA. The model aims to examine the thermal behavior of the containment and provides a comprehensive understanding of the system's natural convection capability during postulated accidents. The results obtained from the model can be used to improve the safety and integrity of the containment system and provide valuable insights for future research in the field.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Transient performance of accident tolerant fuel in design basis accidents

A set of transient analysis has been performed to assess the performance of candidate accident tolerant fuel (ATF) against reference UO{sub 2} fuel with Zircaloy cladding under design basis accident (DBA) conditions. This study examined two ATF options, U{sub 3}Si{sub 2} fuel with SiC cladding and UO{sub 2} fuel with APMT cladding. The accident analyses were conducted using the system code TRACE for a three-loop PWR plant. PARCS standalone full-core calculations were done for each fuel/cladding combination to provide inputs to the TRACE point-kinetics model. The design basis accidents analyzed were a reactivity insertion accident (RIA) and a large break loss-of-coolant accident (LBLOCA). The RIA was simulated by the insertion of a reactivity ramp of $1 (one dollar) in 0.1 s at hot full power (HFP) condition. The LBLOCA was a simulation of a double-ended pipe break in one of the cold legs of the primary loops. Differences in thermal responses of the fuel and the cladding are attributed to their thermal properties. The U{sub 3}Si{sub 2} fuel with its lower volumetric heat capacity and higher thermal conductivity (i.e. higher thermal diffusivity) generally results in a lower fuel temperature than the UO{sub 2} fuel and a correspondingly faster thermal response. Additional calculations for the U{sub 3}Si{sub 2} fuel shows that in a RIA the cladding material, SiC versus Zr, has little impact on the maximum fuel centerline temperature and the PCT (peak cladding temperature). An increase in the hot rod power factor is shown to raise the centerline fuel temperature in a RIA but has little impact on the PCT. The analysis results show that for a relatively fast decay heat driven transient, such as the LBLOCA, the thermal-hydraulics and fuel/cladding thermal properties dictate the overall response more so than the reactivity feedback. The results show that the PCTs in a LBLOCA are similar for all fuel/cladding combinations considered in this study. The LBLOCA analysis also notes the impact of the asymmetry in the system response. The fuel rods in the sector of the core connected to the hot leg of the broken loop (Sector 1 in the PWR model) is shown to have a much lower PCT than fuel rods in the other five sectors of the core. Results of this study indicate that for the two DBAs considered (RIA and LBLOCA) the transient behavior and the resulting peak cladding temperature of the two ATF options (U{sub 3}Si{sub 2} fuel with SiC cladding and UO{sub 2} fuel with APMT cladding) are similar to the standard light-water reactor fuel (UO{sub 2} fuel with Zircaloy cladding). (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiphysics analysis of fuel fragmentation, relocation, and dispersal susceptibility–Part 3: Thermal hydraulic evaluation of large break LOCA under high-burnup conditions

Increasing the peak rod average burnup of pressurized water reactor (PWR) fuel beyond 62 GWd/tU may increase fuel fragmentation, relocation, and dispersal (FFRD) susceptibility during a large break loss of coolant accident (LBLOCA). TRACE thermal hydraulic (TH) LBLOCA analyses were performed for a realistic 24-month high-burnup PWR equilibrium cycle, to inform subsequent transient BISON high-burnup FFRD susceptibility evaluations. Realistic LBLOCA systems behavior was first established by configuring to and comparing with the BEMUSE OECD LBLOCA benchmark. Fuel and operating conditions were then applied from high-burnup VERA depletion calculations. LBLOCA simulations were performed for 281 selected high-burnup rods, for which transient TH boundary conditions were collected for later use in BISON. The TRACE results indicated that rod linear heat rate (rather than burnup) is the main predictor of peak cladding temperature (PCT) during the event. PCT typically occurred at a local burnup lower than the rod-average burnup, especially for twice-burned fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison Between Pin-by-Pin Subchannel and System Level Thermal Hydraulic Results for High Burnup Loss-of-Coolant Applications

This milestone report summarizes recent work to investigate higher fidelity modeling and simulation practices for large-break loss-of-coolant accident (LBLOCA) analysis in high-burnup pressurized water reactor (PWR) cores. Because of current industry interest in extending fuel cycle lengths ranging from 18 to 24-months, the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program has been investigating the susceptibility of high-burnup core designs to fuel fragmentation, release, and dispersal (FFRD) during accident conditions such as LBLOCA. This work has prioritized developing and demonstrating a methodology for calculating core-wide susceptibility to FFRD and addressing uncertainties identified in the analysis and the US Nuclear Regulatory Commission (NRC) Research Information Letter on FFRD. Part of this investigation seeks to quantify differences between system-level thermal hydraulic behavior and higher fidelity subchannel modeling methods to identify potential safety concerns or opportunities to minimize FFRD susceptibility. To this end, the NEAMS subchannel code, CTF, is being used, along with the NRC system analysis code TRACE, for analysis of LBLOCA in a core containing high-burnup fuel. This project includes two thrusts: (1) improving on the existing TRACE model for a 4-loop PWR for LBLOCA so that the model is higher fidelity and consistent with current USNRC best practices, and (2) using CTF to perform pin-resolved modeling of the core region of the reflood phase of a LBLOCA in a high-burnup PWR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Emergency core cooling system performance criteria for Multi-Layered Silicon Carbide nuclear fuel cladding

Multi-layered Silicon Carbide (SiC) cladding has been proposed to replace the current Zircaloy (Zr) cladding in existing nuclear power plants. Due to its ceramic property, SiC may have a different failure mechanism from that of metallic Zr clad. This characteristic should be considered in designing the plant’s safety system performance, such that the fuel’s integrity is reasonably assured during accident scenarios. This paper aims at optimizing the Emergency Core Cooling System (ECCS) performance criteria in mitigating LBLOCA accidents at a Pressurized Water Reactor (PWR) using the uranium dioxide fuel and duplex or triplex SiC cladding structures. Clad failures by brittle fractures and thermal degradation were modeled in a fuel analysis code. This fuel model was coupled with the RELAP5 plant model by adapting the fuel’s mesh configuration and formulating the effective heat transfer coefficients. A model to quantify the likelihood of clad functional failure as a combination of individual layer fractures at various axial positions was proposed. Updated SiC material properties were gathered from recent reference studies. Clad reliability estimates using the proposed model were compared with the estimates obtained using other models. The results were used to relax the criterion of required actuation timing of ECCS, such that the risk of the new plant design is less or equal to that of the initial plant configuration. Triplex clad was more reliable than duplex clad and Zr, reducing the conditional core damage probability by three orders of magnitude in the reference LBLOCA scenario. Compressive stresses due to irradiation swelling played the determining role in the vulnerabilities of each clad design. The duplex clad was vulnerable to pressure-loading stresses while triplex clad was prone to fail due to thermal shocks experienced during the LOCA reflood phase. Additionally, it was concluded that the most vulnerable axial fuel rod location in the reference LBLOCA scenario was located at the highest axial power peaking location. A sensitivity study on the ECCS timing density was conducted. The results showed that ECCS actuation timing could be extended from the initial technical specification, without increasing the fuel damage likelihood. The time extension was distributed in the order of several hundreds of seconds, which was comparable with time extensions offered by FeCrAl and Cr-coated-Zr clad designs in LBLOCA scenarios. This time extension may potentially reduce the failure probabilities of EDGs and pumps, hence improving the plant safety further.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A realistic TRACE PWR LOCA model with application to high-burnup analysis

This paper presents a TRACE model of a postulated large-break loss-of-coolant accident (LBLOCA) event in a four-loop pressurized water reactor (PWR). The input files have been made publicly available and serve as a starting point for researchers to improve upon or apply to their purposes. The model, based on a legacy PWR model, contains numerous improvements and modifications consistent with US Nuclear Regulatory Commission LBLOCA analysis guidelines. The model is applied to analyze high-burnup (>62 GWD/MTU) fuel behavior during LBLOCA, improving on previous work to provide realistic thermal hydraulic predictions for future fuel performance analyses and experiments related to fission fragment, relocation, and dispersal (FFRD). Sensitivity studies are presented to quantify the impact of the vessel-modeling approach, core radial discretization, and other phenomena. In conclusion, the model is intended for research purposes and contains sufficient plant geometric, operational, and safety system details to represent the main physical phenomena pertaining to LBLOCA.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Burnup BWR LOCA Burst Analysis Using High-Fidelity Multiphysics Simulations

The US nuclear industry is looking to improve on the operating economics of the current fleet of light-water reactors (LWRs). One way of achieving this is by operating fuel to higher burnup. In pressurized water reactors (PWRs), relaxing the current burnup limit will allow for cycle length extensions and power uprates; in boiling water reactors (BWRs) it may allow for improved fuel utilization and reduced feed assemblies, as well as more efficient power uprates and increased capacity factors that will support the Administration’s Executive Order to facilitate 5 GW of power uprates at existing nuclear facilities. However, one of the key limitations to operating fuel to higher burnup is the risk of fuel fragmentation, relocation, and dispersal (FFRD). Recognizing the high interest in extending burnup limits, the US Nuclear Regulatory Commission (NRC) has issued Draft Regulatory Guide DG-1434, which defines an approach that would be acceptable to the NRC for addressing FFRD risk. The approach defined will require better understanding of the phenomena leading to FFRD as well as best-estimate simulation methods to understand FFRD risk in high-burnup cores. The Nuclear Energy Advanced Modeling and Simulation program is supporting the FFRD industry challenge problem through development of state-of-the-art, high-fidelity modeling and simulation LWR analysis capabilities; namely, the BISON fuel performance code and the VERA core simulator software. These tools, along with the US NRC TRACE system analysis code, have been utilized for analysis of FFRD risk in both PWR and BWR cores in recent years. The work documented in this report addresses the lack of high-fidelity research for BWRs and builds on a previous activity where the framework has been applied to Cycles 16 through 18 of Limerick Unit 1, a BWR/4, with introduction of 8 high-burnup lead use assemblies (HBLUAs) that were representative of the 8 HBLUAs loaded into Limerick Unit 2 in 2021. VERA was used in this previous activity to model rod-by-rod depletion in these cycles, and its solution was used to initialize a TRACE simulation of a large-break loss-of-coolant accident (LBLOCA) at the end of Cycle 18. In the work documented in this report, the TRACE model was improved by refining the core mesh and utilizing a new feature that allows for capturing the full 3D VERA power distribution in the model. This allows for a more detailed solution for setting BISON boundary conditions. Furthermore, the solutions from VERA and TRACE were used to set up and perform BISON simulations of about 1,000 rods sampled from the core, including all burnup levels. Utilizing two cladding burst models, it was shown that no fuel rods were predicted to burst during the postulated LBLOCA transient. Additionally, a sensitivity study was performed by artificially increasing linear heat rate during the postulated LBLOCA to identify parameters that correlate with rod burst susceptibility. Burnup, fission gas release, and hoop strain were all found to be positively correlated with rod burst susceptibility. Small-break loss-of-coolant accident (SBLOCA) analyses were also performed; these analyses predicted cladding temperature increases that were bounded by the LBLOCA cladding temperatures for all small break sizes studied for this plant. However, future refinements to the plant response assumptions during the SBLOCA could impact the predicted cladding response. Finally, a benchmark study was performed between CTF and TRACE for LOCA conditions to better qualify CTF for BWR LOCA modeling.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of the CTF subchannel code for modeling a large-break loss-of-coolant accident reflood transient

With increased industry interest in extending reactor operating cycles, the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program has been investigating the behavior of high-burnup fuel during design basis accidents such as the large-break loss-of-coolant accident (LBLOCA) with consideration for risk of fuel fragmentation, relocation, and dispersal (FFRD). As part of that activity, the NEAMS subchannel thermal/ hydraulics (T/H) code, CTF, is being used for modeling of LBLOCA and to determine the impact of subchannel resolution on results. Although CTF includes a wide range of models for LBLOCA conditions, the code has not been used for this application while maintained at Oak Ridge National Laboratory (ORNL) until now. Therefore, here, in this work, a preliminary assessment of several of these models was performed using openly available reflood experimental data from the Flooding Experiments in Blocked Arrays (FEBA) tests. One coarse mesh and one fine mesh model were set up in CTF for high and low flooding rate tests performed in the unblocked FEBA facility. A coarse TRACE model was set up to be as consistent as possible with the coarse CTF model to allow for code-to-code benchmarking. The assessment shows a tendency of the codes to over-predict peak cladding temperature (PCT) near the top of the bundle and to quench early. Advanced spacer grid models were shown to improve upper bundle predictions in CTF. The resolved CTF model over-predicted PCT by a larger degree in the center channels in the low-flooding rate test, and it is believed that the radiative heat transfer model, which was not used in this study, may be needed to correct this over-prediction. Finally, this work demonstrates the importance of the droplet model in determining quench time and vapor temperature and PCT prediction, which necessitates a more in-depth validation of these models in the future.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Full-core high-burnup BWR LOCA fuel performance analysis and FFRD susceptibility

The susceptibility of the boiling water reactor (BWR) Limerick Unit 1 to fuel fragmentation, relocation, and dispersal during a postulated large-break loss-of-coolant accident (LBLOCA) was calculated using a multiphysics framework. The simulations include full-core, rod-resolved neutronic, thermal hydraulic, and fuel performance models using the VERA, TRACE, and BISON codes. This work focused on the transient BISON simulations, which include both the normal operation and LBLOCA periods in the same simulations. Cladding integrity was assessed using two correlations that are included with BISON. make page break Several new BWR-specific features were recently added to BISON. This work represents the first time these features have been included in a core-scale set of simulations. This study hence evaluates the performance of these new models for an operating reactor with realistic operating conditions. Simulation results showed that cladding integrity was maintained (i.e., no rods burst). Finally, future work to improve BWR and PWR predictions using this framework is suggested.

BISON↗

Preliminary analysis of core heat-up for ATFs under accident conditions

The accident-tolerant fuel (ATF) system is aim at upgrading safety characteristics of the nuclear fuel and cladding in a reactor core where active cooling has been lost, and is preferable or comparable to the conventional UO{sub 2}-Zr fuel system when the reactor is in normal operation. In this paper, the improved performance of UO{sub 2}-SiC, UO{sub 2}-FeCrAl fuel systems, and of fully ceramic micro-encapsulated (FCM) fuels: FCM-SiC and FCM-FeCrAl, on the core heat-up progress in a pressurized water reactor (PWR) is analyzed by using the best-estimate system code RELAP5 and severe accident analysis program. For this purpose two accident scenarios are selected: a large break LOCA as a design base accident and an extended station blackout (SBO) severe accident. For the LBLOCA with just low-pressure safety injection, larger volumetric heat capacity and thermal conductivity of ATF materials contribute to a larger safety margin in terms of the peak cladding temperature compared with UO{sub 2}-Zr. Thanks to higher melting temperatures, FCM-SiC is failed by melting almost 1200 s later than UO{sub 2}-Zr. The accumulated production of hydrogen for ATF materials is around 10 times smaller than that for UO{sub 2}-Zr. However, high temperature oxidation of SiC cladding generates carbon monoxide which is combustible, while the melting point of FeCrAl is not high enough. In the SBO scenario with mitigation measure, the advantage of ATF is more evident. If the mitigation measure could not be taken, core heatup is inevitable for all types of fuel system, but the temperature rising of ATF core is much slower. In general, improved high-temperature properties and resistance to oxidation play important roles for ATF cores.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Analyses of Passive Containment Cooling System for a Concrete Type Containment

The containment of nuclear power plants is the final barrier to keep the radioactive materials from uncontrolled release to the environment. To keep the containment integrity, pressure and temperature must be controlled by the spray system which relies on active components for PWRs with a concrete containment. To achieve a passive means to keep the containment integrity, therefore, cooling should be achieved by forming a natural circulation loop between internal cooling devices connected to an external heat sink. A system like this is often called Passive Containment Cooling System (PCCS). In the early phase of APR-1400 development, this concept was studied and VVER-1200 is also known to adopt the PCCS. The PCCS consists of a cooling device installed at the inside of the containment which is a tube-bank type heat exchanger where cooling occurs at the exterior of the tubes and a heat sink which is called Passive Containment Cooling Tank (PCCT) located at the outside of the containment on the top of the auxiliary building. In this paper, we introduce performance analysis results, utilizing the GOTHIC computer code. The PCCS performance analysis model was developed for APR-1400 which has a thermal power of 4000 MW and considers PCCS as an option to improve its safety characteristics. The PCCS which is considered in this paper is to cope with both Design Basis and Severe Accidents, considering SBO conditions. The pressure and temperature transients due to the Loss of Coolant Accident (LOCA) were analyzed with and without PCCS together with a normal case using the spray system. And, in particular, limitations of the PCCS in regard to mission time will be discussed. Through this study, it was found that the PCCS being considered as an option to improve the safety of APR-1400 can have almost same capability to control the containment pressure for LBLOCA as the containment spray system does. Although it would depends on the heat removal capacity of a given design such as the size of the heat transfer area, the PCCS could even replace the containment spray system. However, the PCCS may lose its capability after 24 hours as its temperature reaches that of the containment atmosphere. To extend the mission time of PCCS, either cooling or supplementary cold water needs to be provided to the external heat sink of PCCS. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Code Validation of a SBLOCA test in SMART Integral Test Loop

Integrated small modular reactors (iSMRs) are favored because of their unique characteristics, such as enhanced safety without any large break loss of coolant accidents (LBLOCAs), low initial construction costs, and multi-use of desalination and electricity generation. Many iSMRs have been developed thus far. In Korea, an iSMR called SMART was developed after a thorough validation of the components and systems, and finally received its design certificate in 2012 for the first time in the world. To ensure the performance of its safety systems, an integral test loop, SMART-ITL, is constructed. It contains the primary system, secondary system, passive safety systems, and an auxiliary system. The passive safety systems include a passive residual heat removal system (PRHRS), passive injection system with a core makeup tank (CMT) and a safety injection tank (SIT), and an automatic depressurization system (ADS). The height is preserved while the diameter is scaled down to 1:7. A series of SBLOCA tests have been performed with 4 trains of PRHRS, 1 train of CMT and SIT, and ADS. In parallel with the experiments, simulation of a representative test has been conducted to track the underlying thermal hydraulics. SMART-ITL is an integral test loop for SMART and a series of SBLOCA tests for confirming the performance of passive safety systems have been conducted. In this paper, a system code simulation on a SBLOCA test using SMART-ITL is presented. The reactor vessel water level, break flow rate, and CMT and SIT water levels are predicted well. (authors)

42 ENGINEERING↗

The MELCOR Analysis of Chinshan Nuclear Power Plant Spent Fuel Pool for Fukushima-like Accident

The safety analysis of the nuclear power plant (NPP) is very important work in the NPP safety. Especially after the Fukushima NPP accident occurred, the importance of NPP safety analysis has been raised and there is more concern for the safety of NPPs in Taiwan. Because the earthquake and tsunami occurred, the cooling system of spent fuel pool failed and the safety issue of spent fuel pool generated in Japan's Fukushima NPP. Chinshan NPP is the first NPP in Taiwan which is BWR/4 plant and OLTP (Original Licensed Thermal Power) for each unit is 1775 MWt. Chinshan NPP finished SPU (stretch power uprate) and the operating power is 103.66% of the OLTP, which is 1840 MWt now. After Fukushima NPP accident occurred, in order to concern the safety of Chinshan NPP spent fuel pool, we performed the safety analysis of spent fuel pool by using MELCOR/SNAP which also assumed the cooling system of spent fuel pool failed. The geometry of Chinshan NPP spent fuel pool is 12.17 m x 7.87 m x 11.61 m and the initial condition is 60 deg. (water temperature) / 1.013 x 10{sup 5} Pa. And, the total power of the fuels is roughly 8.9 MWt initially. MELCOR is developed by Sandia National Laboratories. MELCOR is a fully integrated, engineering-level computer code that models the progression of severe accidents in light water reactor NPPs, including containment response and leakage of activity to the environment. A broad spectrum of severe accident phenomena in both BWRs and PWRs is treated in MELCOR in a unified framework. These include thermalhydraulic response in the reactor coolant system, reactor cavity, containment, and confinement buildings; core heatup, degradation, and relocation; core-concrete attack; hydrogen production, transport, and combustion; fission product release and transport behavior. Current uses of MELCOR include estimation of severe accident source terms and their sensitivities and uncertainties in a variety of applications. According to Dr. Carbajo's paper, MELCOR was used to perform the study of spent fuel pool of Fukushima Daiichi Unit 4. Niina E. Koenoenen used MELCOR to establish the spent fuel pool model of a Nordic BWR. The loss-of-pool-cooling accidents was simulated and analyzed by this model. The above studies indicate that MELCOR is capable of handling the simulation of the spent fuel pool. An increasing number of researchers are using MELCOR code to analyze test facilities and nuclear power plants. Jun Wang et al. used MELCOR to perform core degradation simulation and MELCOR results were compared with CORA experimental data. Through this work, they reviewed the performance of MELCOR COR package in detail. Tae Woon Kim et al. developed MELCOR model of APR1400 (an advanced pressurized water reactor). They used this model to perform the LBLOCA transient simulation and sensitivity study. Longze Li et al. established the MELCOR model of CPR1000 (a Chinese pressurized reactor 1000-MW power plant). The station blackout (SBO) with failure of the steam generator (SG) safety relief valve (SRV) transient was simulated and analyzed by this model. SNAP is a graphic user interface program that processes the inputs and outputs of MELCOR. In addition, there is an animation function in SNAP which can present the animation of analysis results. There are two main steps in this research. The first step was the establishment of Chinshan NPP spent fuel pool MELCOR/SNAP model. And the transient analysis of Chinshan NPP spent fuel pool MELCOR/SNAP model under the cooling system failure condition was performed. The next step was the comparison among the MELCOR, TRACE and CFD data. TRACE and CFD data were from INER reports. In addition, the animation model of Chinshan NPP spent fuel pool was presented by using the animation function of SNAP with MELCOR/SNAP analysis results. This study has developed MELCOR/SNAP model of Chinshan NPP spent fuel pool successfully. By using the above model, the safety analysis of the spent fuel pool was performed under the cooling system of spent fuel pool failed condition. The analysis results of MELCOR, TRACE and CFD were similar in this case. It indicated that there was a respectable accuracy in MELCOR/SNAP model. The analysis results depicted that the uncovered of the fuels occurred at 2.6 day and the metal-water reaction of fuels occurred roughly at 3.7 day after the cooling system failed. The above results indicated that the failure of cladding occurred after 3.7 day. This study's results can help to evaluate the safety issue of Chinshan NPP spent fuel pool. In addition, the cooling system and some mitigation measures of spent fuel pool is not simulated in the above model. However, we will do it in the future. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Source term analysis of FeCrAl accident tolerant fuel using MELCOR

It has been established that incremental improvements in beyond design basis accident performance can be achieved through accident tolerant fuel (ATF). However, they have the potential to recover margin with respect to conventional fuel and therefore enhance plant economics through uprate or cycle length increase. To realize this potential, it is necessary to quantify the reduction in source term due to use of ATF, and correspondingly how this is affected by increasing the cycle length and/or burnup. This requires development of a risk informed analysis methodology for ATF under high burnup conditions, which is being developed within LWRS. To this end, a MELCOR simulation of FeCrAl ATF in a recovered Large Break LOCA (LBLOCA) scenario has been developed, using a model based on the Zion Pressurized Water Reactor (PWR). The new user defined material capability, along with the inclusion of detailed neutronics- and depletion-derived parameters such as core power distribution, decay heat behavior, and fission product inventories, allows a more detailed simulation of FeCrAl clad material properties and behavior than has previously been possible using MELCOR. These detailed FeCrAl results were compared with a zircaloy clad model to investigate the differences between the two clad types and quantify the benefits of FeCrAl ATF with an 18-month cycle. Next, the fuel cycle with ATF was extended to 24 months, to determine whether any additional safety margin provided by FeCrAl ATF could be leveraged to implement high burnup FeCrAl-clad fuel while retaining the same operating and safety limits as current zircaloy-clad fuel. For the particular scenario analyzed, the delay to fuel failure from using ATF was of the same order as the LOCA recovery time, and hence significant in reducing fission product release, with the 24-month FeCrAl core performing better than the 18-month zircaloy core. It is noted that for other transients, the reduction in release due to using FeCrAl may be less significant. Furthermore, the material model developed here can be used in such further studies in support of determining the overall source term.