Search NASASearch

SEARCH · Search NASA

Results for “LCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hybrid LCD driver

Display driver for hand-held signs monitor can be configured to operate either 4 digit or, by paralleling four drivers, to operate 16 digit liquid crystal display (LCD).

Rinard, G. A.

Command and Data Handling Branch Internship

Modular Integrated Stackable Layers (MISL) is a computer system designed for simple, fast, and cost effective flexible reconfiguration in space environments such as the ISS and Orion projects for various uses. Existing applications include wireless and wired communications, data acquisition and instrumentation, and camera systems, and potential applications include bus protocol converters and subsystem control. MISL is based on Texas Instruments (TI)' MSP430 16-bit ultra-low-power microcontroller device. The purpose of my project was to integrate the MISL system with a liquid crystal display (LCD) touchscreen. The LCD, manufactured by Crystalfontz and part number CFAF320240F-035T-TS, is a 320 by 240 RGB resistive color screen including an optional carrier board. The vast majority of the project was done with Altium Designer, a tool for printed circuit board (PCB) schematic capture, 3D design, and FPGA (Field Programmable Gate Array) development. The new PCB was to allow the LCD to directly stack to the rest of MISL. Research was done with datasheets for the TI microcontroller and touchscreen display in order to meet desired hardware specifications. Documentation on prior MISL projects was also utilized. The initial step was to create a schematic for the LCD, power bus, and data bus connections between components. A layout was then designed with the required physical dimensions, routed traces and vias, power and ground planes, layer stacks, and other specified design rules such as plane clearance and hole size. Multiple consultation sessions were held with Hester Yim, the technical discipline lead for the Command and Data Handling Branch, and Christy Herring, the lead PCB layout designer in the Electronic Design and Manufacturing Branch in order to ensure proper configuration. At the moment, the PCB is awaiting revision by the latter-mentioned branch. Afterwards, the board will begin to undergo the manufacturing and testing process. Throughout the internship at Johnson Space Center, I gained several technical and professional skills. I gained proficiency in Altium Designer and experience using subversion clients, as well as knowledge in PSpice with OrCAD and battery design for spaceflight from on-site. I also gained networking, organization, and communication skills throughout meetings with coworkers and other interns. This internship at Johnson Space Center has impacted my future aspirations by further inspiring me to follow a career path into space rated engineering technology and human spaceflight applications. After graduation, I plan to attend graduate Modular Integrated Stackable Layers (MISL) is a computer system designed for simple, fast, and cost effective flexible reconfiguration in space environments such as the ISS and Orion projects for various uses. Existing applications include wireless and wired communications, data acquisition and instrumentation, and camera systems, and potential applications include bus protocol converters and subsystem control. MISL is based on Texas Instruments’ MSP430 16 bit ultra-low power microcontroller device. The purpose of my project was to integrate the MISL system with a liquid crystal display touchscreen. The LCD, manufactured by Crystalfontz and part number CFAF320240F-035T-TS, is a 320x240 RGB resistive color screen including an optional carrier board.The vast majority of the project was done with Altium Designer, a tool for printed circuit board (PCB) schematic capture, 3D design, and FPGA development. The new PCB was to allow the LCD to directly stack to the rest of MISL. Research was done with datasheets for the TI microcontroller and touchscreen display in order to meet desired hardware specifications. Documentation on prior MISL projects was also utilized. The initial step was to create a schematic for the LCD, power bus, and data bus connections between components. A layout was then designed with the required physical dimensions, routed traces and vias, power and ground planes, layer stacks, and other specified design rules such as plane clearance and hole size. Multiple consultation sessions were held with Hester Yim, the technical discipline lead for the Command and Data Handling Branch, and Christy Herring, the lead PCB layout designer in the Electronic Design and Manufacturing Branch in order to ensure proper configuration. At themoment, the PCB is awaiting revision by the latter-mentioned branch. Afterwards, the board will begin to undergo the manufacturing and testing process.Throughout the internship at Johnson Space Center, I gained several technical and professional skills. I gained proficiency in Altium Designer and experience using subversion clients, as well as knowledge in PSpice with OrCAD and battery design for spaceflight from on-site. I also gained networking, organization, and communication skills throughout meetings with coworkers and other interns. This internship at Johnson Space Center has impacted my future aspirations by further inspiring me to follow a career path into space rated engineering technology and human spaceflight applications. After graduation, I plan to attend graduate school for a master's or doctorate degree in electrical or computer engineering.

Billings, Rachel Mae

Full resolution hologram-like autostereoscopic display

Under this program, Dimension Technologies Inc. (DTI) developed a prototype display that uses a proprietary illumination technique to create autostereoscopic hologram-like full resolution images on an LCD operating at 180 fps. The resulting 3D image possesses a resolution equal to that of the LCD along with properties normally associated with holograms, including change of perspective with observer position and lack of viewing position restrictions. Furthermore, this autostereoscopic technique eliminates the need to wear special glasses to achieve the parallax effect. Under the program a prototype display was developed which demonstrates the hologram-like full resolution concept. To implement such a system, DTI explored various concept designs and enabling technologies required to support those designs. Specifically required were: a parallax illumination system with sufficient brightness and control; an LCD with rapid address and pixel response; and an interface to an image generation system for creation of computer graphics. Of the possible parallax illumination system designs, we chose a design which utilizes an array of fluorescent lamps. This system creates six sets of illumination areas to be imaged behind an LCD. This controlled illumination array is interfaced to a lenticular lens assembly which images the light segments into thin vertical light lines to achieve the parallax effect. This light line formation is the foundation of DTI's autostereoscopic technique. The David Sarnoff Research Center (Sarnoff) was subcontracted to develop an LCD that would operate with a fast scan rate and pixel response. Sarnoff chose a surface mode cell technique and produced the world's first large area pi-cell active matrix TFT LCD. The device provided adequate performance to evaluate five different perspective stereo viewing zones. A Silicon Graphics' Iris Indigo system was used for image generation which allowed for static and dynamic multiple perspective image rendering. During the development of the prototype display, we identified many critical issues associated with implementing such a technology. Testing and evaluation enabled us to prove that this illumination technique provides autostereoscopic 3D multi perspective images with a wide range of view, smooth transition, and flickerless operation given suitable enabling technologies.

Eichenlaub, Jesse B.

JTEC panel on display technologies in Japan

This report is one in a series of reports that describes research and development efforts in Japan in the area of display technologies. The following are included in this report: flat panel displays (technical findings, liquid crystal display development and production, large flat panel displays (FPD's), electroluminescent displays and plasma panels, infrastructure in Japan's FPD industry, market and projected sales, and new a-Si active matrix liquid crystal display (AMLCD) factory); materials for flat panel displays (liquid crystal materials, and light-emissive display materials); manufacturing and infrastructure of active matrix liquid crystal displays (manufacturing logistics and equipment); passive matrix liquid crystal displays (LCD basics, twisted nematics LCD's, supertwisted nematic LCD's, ferroelectric LCD's, and a comparison of passive matrix LCD technology); active matrix technology (basic active matrix technology, investment environment, amorphous silicon, polysilicon, and commercial products and prototypes); and projection displays (comparison of Japanese and U.S. display research, and technical evaluation of work).

Tannas, Lawrence E., Jr.

Record of Decision: H - LEBT Design Modifications

The LAMP Conceptual Design (LCD) is described in the LAMP Conceptual Design Report. The proposed new configuration of the LAMP H - LEBT encompasses multiple changes to the LCD. The new configuration makes use of a single H - source to supply beam to all LANSCE user stations except IPF; this eliminates one of the H - sources in the LCD, and the associated pulsed merger magnet the use of two such sources required. The source current from the sole H - source is gated on a macropulse-by-macropulse basis using techniques demonstrated at SNS (Spallation Neutron Source), specifically, changes to the RF plasma drive power. A pulsed electrode system is used to match the beam into the LEBT transport line, variable on a macropulse-by-macropulse basis to match the source beam current.

43 PARTICLE ACCELERATORS

Calibration tests on magnetic tape lightning current detectors

The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

Crouch, K. E.

Using convolutional neural networks to accelerate three-dimensional coherent synchrotron radiation computations

Calculating the effects of coherent synchrotron radiation (CSR) is one of the most computationally expensive tasks in accelerator physics. Here, we use convolutional neural networks (CNNs), along with a latent conditional diffusion (LCD) model, trained on physics-based simulations to speed up calculations. Specifically, we produce the 3D CSR wakefields generated by electron bunches in circular orbit in the steady-state condition. Two datasets are used for training and testing the models: wakefields generated by three-dimensional Gaussian electron distributions and wakefields from a sum of up to 25 three-dimensional Gaussian distributions. The CNNs are able to accurately produce the 3D wakefields ∼250–1000 times faster than the numerical calculations, while the LCD achieves a gain of a factor of ∼34. We also test the extrapolation and out-of-distribution generalization ability of the models. They generalize well on distributions with larger spreads than what they were trained on but struggle with smaller spreads.

43 PARTICLE ACCELERATORS

Magnetic tape lightning current detectors

Development and application tests of a low cost, passive, peak lightning current detector (LCD) found it to provide measurements with accuracies of + or - 5 percent to + or - 10 percent depending on the readout method employed. The LCD uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. The test results showed that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10 percent were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result.

Crouch, K. E.

Studies of the field-of-view resolution tradeoff in virtual-reality systems

Most virtual-reality systems use LCD-based displays that achieve a large field-of-view at the expense of resolution. A typical display will consist of approximately 86,000 pixels uniformly distributed over an 80-degree by 60-degree image. Thus, each pixel subtends about 13 minutes of arc at the retina; about the same as the resolvable features of the 20/200 line of a Snellen Eye Chart. The low resolution of LCD-based systems limits task performance in some applications. We have examined target-detection performance in a low-resolution virtual world. Our synthesized three-dimensional virtual worlds consisted of target objects that could be positioned at a fixed distance from the viewer, but at random azimuth and constrained elevation. A virtual world could be bounded by chromatic walls or by wire-frame, or it could be unbounded. Viewers scanned these worlds and indicated by appropriate gestures when they had detected the target object. By manipulating the viewer's field size and the chromatic and luminance contrast of annuli surrounding the field-of-view, we were able to assess the effect of field size on the detection of virtual objects in low-resolution synthetic worlds.

Piantanida, Thomas P.

Sarnoff JND Vision Model for Flat-Panel Design

This document describes adaptation of the basic Sarnoff JND Vision Model created in response to the NASA/ARPA need for a general-purpose model to predict the perceived image quality attained by flat-panel displays. The JND model predicts the perceptual ratings that humans will assign to a degraded color-image sequence relative to its nondegraded counterpart. Substantial flexibility is incorporated into this version of the model so it may be used to model displays at the sub-pixel and sub-frame level. To model a display (e.g., an LCD), the input-image data can be sampled at many times the pixel resolution and at many times the digital frame rate. The first stage of the model downsamples each sequence in time and in space to physiologically reasonable rates, but with minimum interpolative artifacts and aliasing. Luma and chroma parts of the model generate (through multi-resolution pyramid representation) a map of differences-between test and reference called the JND map, from which a summary rating predictor is derived. The latest model extensions have done well in calibration against psychophysical data and against image-rating data given a CRT-based front-end. THe software was delivered to NASA Ames and is being integrated with LCD display models at that facility,

Brill, Michael H.

Using the Human Eye to Characterize Displays

Monitor characterization has taken on new importance for non-professional users, who are not usually equipped to make photometric measurements. We studied adjusting brightness to set the black level, banding effects due to digitization, and gamma estimation in the light and in the dark, and a color-matching task in the light, on a desktop CRT (Cathode-Ray Tube) and a laptop LCD (Liquid Crystal Display). Observers demonstrated the sensitivity of the visual system for comparative judgments in black-level adjustment, banding visibility, and gamma estimation. The results of the color-matching task were ambiguous. In the brightness adjustment task, the action of the adjustment was not as presumed; however, perceptual judgments were as expected under the actual conditions. When the gamma estimates of observers were compared to photometric measurements, problems with the definition of gamma were identified. Information about absolute light levels that would be important for characterizing a displays, given the shortcomings of gamma in measuring apparent contrast, are not measurable by eye alone. The LCD was not studied as extensively as the CRT because of viewing-angle problems, and its transfer function did not follow a power law, rendering gamma estimation meaningless.

Gille, Jennifer

The New Realm of 3-D Vision

Dimension Technologies Inc., developed a line of 2-D/3-D Liquid Crystal Display (LCD) screens, including a 15-inch model priced at consumer levels. DTI's family of flat panel LCD displays, called the Virtual Window(TM), provide real-time 3-D images without the use of glasses, head trackers, helmets, or other viewing aids. Most of the company initial 3-D display research was funded through NASA's Small Business Innovation Research (SBIR) program. The images on DTI's displays appear to leap off the screen and hang in space. The display accepts input from computers or stereo video sources, and can be switched from 3-D to full-resolution 2-D viewing with the push of a button. The Virtual Window displays have applications in data visualization, medicine, architecture, business, real estate, entertainment, and other research, design, military, and consumer applications. Displays are currently used for computer games, protein analysis, and surgical imaging. The technology greatly benefits the medical field, as surgical simulators are helping to increase the skills of surgical residents. Virtual Window(TM) is a trademark of Dimension Technologies Inc.

Source record

Using the Human Eye to Characterize Displays

Monitor characterization has taken on new importance for non-professional users, who are not usually equipped to make photometric measurements. Our purpose was to examine some of the visual judgments used in characterization schemes that have been proposed for web users. We studied adjusting brightness to set the black level, banding effects due to digitization, and gamma estimation in the light and in the dark, and a color-matching task in the light, on a desktop CRT and a laptop LCD. Observers demonstrated the sensitivity of the visual system for comparative judgments in black-level adjustment, banding visibility, and gamma estimation. The results of the color-matching task were ambiguous. In the brightness adjustment task, the action of the adjustment was not as presumed; however, perceptual judgments were as expected under the actual conditions. When the gamma estimates of observers were compared to photometric measurements, problems with the definition of gamma were identified. Information about absolute light levels that would be important for characterizing a display, given the shortcomings of gamma in measuring apparent contrast, are not measurable by eye alone. The LCD was not studied as extensively as the CRT because of viewing-angle problems, and its transfer function did not follow a power law, rendering gamma estimation meaningless.

Gille, Jennifer

New approaches to virtual environment surgery

This research focused on two main problems: 1) low cost, high fidelity stereoscopic imaging of complex tissues and organs; and 2) virtual cutting of tissue. A further objective was to develop these images and virtual tissue cutting methods for use in a telemedicine project that would connect remote sites using the Next Generation Internet. For goal one we used a CT scan of a human heart, a desktop PC with an OpenGL graphics accelerator card, and LCD stereoscopic glasses. Use of multiresolution meshes ranging from approximately 1,000,000 to 20,000 polygons speeded interactive rendering rates enormously while retaining general topography of the dataset. For goal two, we used a CT scan of an infant skull with premature closure of the right coronal suture, a Silicon Graphics Onyx workstation, a Fakespace Immersive WorkBench and CrystalEyes LCD glasses. The high fidelity mesh of the skull was reduced from one million to 50,000 polygons. The cut path was automatically calculated as the shortest distance along the mesh between a small number of hand selected vertices. The region outlined by the cut path was then separated from the skull and translated/rotated to assume a new position. The results indicate that widespread high fidelity imaging in virtual environment is possible using ordinary PC capabilities if appropriate mesh reduction methods are employed. The software cutting tool is applicable to heart and other organs for surgery planning, for training surgeons in a virtual environment, and for telemedicine purposes.

NASA Discipline Neuroscience

A Countermeasure for Space Motion Sickness

Overall, the results obtained in both the U.S. and the Russian space programs indicate that most space crews will experience some symptoms of motion sickness (MS) causing significant impact on the operational objectives that must be accomplished to assure mission success. At this time the primary countermeasure for MS requires the administration of Promethazine. Promethazine is not a benign drug, and is most frequently administered just prior to the sleep cycle to prevent its side effects from further compromising mission objectives. Clearly other countermeasures for SMS must be developed. Currently the primary focus is on two different technologies: (1) developing new and different pharmacological compounds with less significant side effects, (2) preflight training. The primary problem with all of these methods for controlling MS is time. New drugs that may be beneficial are years from testing and development, and preflight training requires a significant investment of crew time during an already intensive pre-launch schedule. Granted, motion sickness symptoms can be minimized with either of the two methods detailed above, however, it may be possible to develop a countermeasure that does not require either extensive adaptation time or exposure to motion sickness. Approximately 25 years ago Professor Geoffrey Melvill Jones presented his work on adaptation of the vestibuloocular reflex (VOR) using optically reversed vision (left-right prisms) during head rotations in the horizontal plane. It was of no surprise that most subjects experienced motion sickness while wearing the optically reversing prisms. However, a serendipitous finding emerged during this research showing that the same subjects did not experience motion sickness symptoms when wearing the reversing prisms under stroboscopic illumination. The mechanism, by which this side-effect was believed to have occurred, is not clearly understood. However, the fact that no motion sickness was ever noted, suggests the possibility of producing functionally useful adaptation during space flight without the penalty of disabling motion sickness by controlling the rate of the adaptive process by means of an appropriate stroboscopically presented environment. After several recent meetings with Professor Melvill Jones, we were encouraged to repeat the motion sickness portions of his and Mandl's 1981 stroboscopic experiment. In conducting this experiment we used a randomized cross-over design where subjects were randomly assigned to either a stroboscopic flash or no strobe for their first exposure in the experimental design. Twenty subjects (19 subjects completed the study) read a short passage from Treasure Island mounted on the wall approximately 1 m from their eyes while wearing left-right reversing prisms. The strobe on time of 3 microseconds and flash frequency of 4 Hz was set to equal that used in the original study. Motion sickness was scored using a modified Miller and Graybiel scale that we constructed to include symptoms that may be elicited under conditions where reversing prisms are worn. On this scale a score of 5 represented Malaise IIa (mild motion sickness) and a score of 8 or above is approaching frank sickness. Symptoms were tracked and recorded every 5 min during the task. Testing was limited to 30 min unless the subject had reached the MIIa score, at which time the test was terminated. Performance under stroboscopic illumination was significantly better than when the subjects read under normal room illumination while wearing the left-right reversing prisms. Based on these results we developed a goggle system using LCD material that can be strobed. To evaluate the effectiveness of stroboscopic goggles we tested an additional 9 subjects in addition to retesting 10 used in the stroboscopic pilot study described above. These 19 subjects wore a pair of strobing LCD goggles that could be cycled at 4 Hz. These subjects wore the goggles while also wearing left-right reversg prisms. Results while wearing the goggles showed that none of the 19 subjects scored at the MIIa level on the motion sickness rating scale. When the goggles did not flash (no strobe), 11 of the 19 developed symptoms above the MIIa criteria. As a countermeasure the goggles seem to be effective, even with an on time of 10 msec (time the goggles are clear). We have also collected anecdotal data, from our personnel in the Neuroscience Laboratory at the Johnson Space Center, suggesting that the goggles may effective in preventing carsickness.

Reschke, M. F.

Stroboscopic Vision as a Treatment Motion Sickness

Results obtained from space flight indicate that most space crews will experience some symptoms of motion sickness causing significant impact on the operational objectives that must be accomplished to assure mission success. Based on the initial work of Melvill-Jones, we have evaluated stroboscopic vision as a method of preventing motion sickness. Methods: Nineteen subjects read text while making +/-20deg head movements in the horizontal plane at 0.2 Hz while wearing left-right reversing prisms during exposure to 4 Hz stroboscopic or normal room illumination. Testing was repeated using LCD shutter glasses as the stroboscopic source with an additional 19 subjects. Results: With Strobe, motion sickness was significantly lower than with normal room illumination. Results with the LCD shutter glasses were analogous to those observed with environmental strobe. Conclusions: Stroboscopic illumination appears to be effective where retinal slip is a factor in eliciting motion sickness. Additional research is evaluating the glasses efficacy for, carsickness, sickness in parabolic flight and seasickness. There is evidence from pilot studies showing that the glasses reduce saccade velocity to visually presented targets by approximately half of the normal values. It is interesting to note that adaptation to space flight may also slow saccade velocity.

Reschke, Millard F.