Search NASA⌕ Search

SEARCH · Search NASA

Results for “LCOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cost and Energy Metrics for Municipal Water Reuse

Municipal water reuse can contribute to a circular water economy in different contexts and with various treatment trains. This study synthesized information regarding the current technological and regulatory statuses of municipal reuse. It provides process-level information on cost and energy metrics for three potable reuse and one nonpotable reuse case studies using the new Water Techno-economic Assessment Pipe-Parity Platform (WaterTAP3). WaterTAP3 enabled comparisons of cost and energy metrics for different treatment trains and for different alternative water sources consistently with a common platform. A carbon-based treatment train has both a lower calculated levelized cost of water (LCOW) ($0.40/m3) and electricity intensity (0.30 kWh/m3) than a reverse osmosis (RO)-based treatment train ($0.54/m3 and 0.84 kWh/m3). In comparing LCOW and energy intensity for water production from municipal reuse, brackish water, and seawater based on the largest facilities of each type in the United States, municipal reuse had a lower LCOW and electricity than seawater but higher values than for production from brackish water. For a small (2.0 million gallon per day) inland RO-based municipal reuse facility, WaterTAP3 evaluated different deep well injection and zero liquid discharge (ZLD) scenarios for management of RO concentrate. Adding ZLD to a facility that currently allows surface discharge of concentrate would approximately double the LCOW. For all four case studies, LCOW is most sensitive to changes in weighted average cost of capital, on-stream capacity, and plant life. Baseline assessments, pipe parity metrics, and scenario analyses can inform greater observability and understanding of reuse adoption and the potential for cost-effective and energy-efficient reuse.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Zero Liquid Discharge and Water Reuse in Recirculating Cooling Towers at Power Facilities: Review and Case Study Analysis

Zero liquid discharge (ZLD) systems installed at power facilities with the primary purpose of meeting water discharge regulations have the added benefit of providing high quality effluent that can be reused in the facility. This paper provides a review of water use in power sector recirculating cooling towers and a baseline assessment of on-site water reuse at natural gas combined cycle (NGCC) power facilities. Two NGCC facilities with reverse-osmosis (RO) or brine-concentrator processes followed by evaporation ponds were selected as case studies; data from these facilities were used to quantify the water, energy, and cost implications of implementing conventional and emerging ZLD technologies. At one case study facility, model results show that implementation of ZLD would reduce water withdrawals by 18%, which is less than savings associated with implementation of dry cooling but comparable to current efforts to reduce water withdrawals by increasing cycles of concentration. Implementation of ZLD using high-recovery RO resulted in a doubling of the levelized cost of water (LCOW). LCOW increased more when a brine concentrator was used. For both case studies, the ZLD system using high-recovery RO required less than 0.1% of a facilitiy's annual electricity generation and the ZLD system using a brine concentrator process required less than 0.8%. Additionally, increasing the evaporation pond area to minimize required ZLD system recovery rates and reduce system electricity costs does not reduce the LCOW. Instead, the LCOW increases because less water is recovered and more water is lost to evaporation. Furthermore, if water availability decreases or water competition/cost increases, facilities may be incentivized to maximize water recovery from ZLD systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost optimization of low-salt-rejection reverse osmosis

Low-salt-rejection reverse osmosis (LSRRO) is an emerging membrane-based desalination technology for concentrating brines with potentially lower energy consumption and cost than thermally driven processes. We assess the technoeconomic performance of LSRRO by using an optimization model that minimizes the levelized cost of water (LCOW). We develop detailed models for the RO module and other equipment using WaterTAP (Water treatment Technoeconomic Assessment Platform), an open-source simulation and optimization software for water treatment. We improve upon previous LSRRO cost optimization studies by optimizing the salt permeability for each stage, which has significant implications for technoeconomic performance. We present the cost-optimal design, operation, and performance for three cases: 35 g/L TDS feed at 70% recovery, 70 g/L at 55%, and 125 g/L at 35%. The cost-optimal LCOW and specific energy consumption (SEC) for these cases are 0.70, 1.89, and 7.41 $/m 3 and 3.9, 8.4, and 30.4 kWh/m 3 , respectively. For each case, we use sensitivity analyses to provide guidance on key factors that impact economic viability. We also present the cost-optimal LCOW and SEC for feed concentrations between 5 and 220 g/L TDS and recoveries between 30 and 90%. So, we compare LSRRO to other high-salinity desalination technologies and find that it may be cost-competitive below feed concentrations of 125 g/L.

54 ENVIRONMENTAL SCIENCES↗

Nonlinear programming optimization of a single-stack electrodialysis desalination system for cost efficiency

Electrodialysis (ED) presents a competitive method for desalinating brackish waters. In this work, we perform cost optimization of a single-stack ED system across a range of feed salinities and water recoveries while optimizing operating voltage, number of cell pairs, and cell length. The results of our optimization show that the levelized cost of water (LCOW) increases with an increase in feed salinity. The outcomes of our optimization show that cost-optimal design generally increases cell length while decreasing cell pair number and operating voltage with an increase in salinity. These trends are nonlinear, with the number of cell pairs and applied voltage exhibiting local maxima when operating at low salinity and high recovery. We discuss the underlying mechanism for cell length becoming a leveraging design parameter by inspecting the length-dependent profiles of key electrochemical properties of the ED cell. Finally, we present how increasing performance metrics and decreasing costs impact LCOW, demonstrating that innovations that decrease counter-current diffusion have resulted in the highest decrease of LCOW.

42 ENGINEERING↗

De-Risking High-Recovery Brackish Water Desalination via Flow Reversal and Feed Flushing Using Techno-Economic Assessment

Novel desalination technologies have demonstrated enhanced performance and improved financial metrics over existing processes adopted by industry. Establishing quantitative performance targets is essential for achieving financial benefits over the current state of the art. Herein, we demonstrate how WaterTAP, a techno-economic assessment (TEA) tool, can be used to identify minimum performance metrics necessary to achieve financial benefit over using existing processes. This study evaluates the feasibility of increasing water recovery at the Chino Desalter I above 90 % through the addition of a third variable configuration reverse osmosis (VCRO) stage. Sensitivity analyses revealed flow reversal frequency, feed flushing volume (used as a cleaning step), and membrane lifespan are key factors influencing the financial viability of the VCRO process. The TEA analysis demonstrated that the system must achieve a recovery of 84 % and a 1-year membrane lifespan to have a breakeven LCOW, while achieving 90 % recovery can ultimately reduce the LCOW by 16 %. Notably, a trade-off between decreasing frictional losses and increased osmotic pressure across the recovery range, resulted in a stable specific energy consumption across the recovery range, enabling meaningful LCOW reductions without an energy penalty, a key finding that contrasts with conventional RO. This work demonstrates how TEA can guide system design by identifying key performance targets and exploring trade-offs, enabling data-driven decisions to de-risk innovative processes. These findings underscore the importance of leveraging TEA to evaluate scaling mitigation strategies and optimize inland desalination systems for sustainable and cost-effective operation.

14 SOLAR ENERGY↗

Component innovations for lower cost mechanical vapor compression

Despite significant capital and operating costs, mechanical vapor compression (MVC) remains the preferred technology for challenging brine concentration applications. Here, this work seeks to assess the dependence of MVC costs on feedwater salinity and desired water recovery and to quantify the value of improved component performance or reduced component costs for reducing the levelized cost of water (LCOW) of MVC. We built a cost optimization model coupling thermophysical, heat and mass transfer, and technoeconomic models to optimize and identify low cost MVC system designs as a function of feedwater salinity and water recovery. The LCOW ranges over 3.6 to 6.1 $\$$/m 3 for seawater feed salinities of 25–150 g/kg and water recoveries of 40–80 %. We then perform sensitivity analysis on parameter inputs to isolate irreducible costs and determine high value component innovation targets. The LCOW was most sensitive to evaporator material costs and performance, including the overall heat transfer coefficient in the evaporator. Process and material innovations such as polymer-composite evaporator tubes that reduce evaporator costs by 25 % without reducing heat transfer performance by more than 10 % would result in MVC cost reductions of 8 %.

42 ENGINEERING↗

Assessing the Accuracy of Property Model Predictions for Cost Optimization of Desalination Technologies

Accurate modeling of seawater thermophysical and thermodynamic properties is critical for optimizing desalination processes. This study compares three seawater property models, a Reaktoro multicomponent model, the thermophysical seawater properties library from the Massachusetts Institute of Technology, and a simplified sodium chloride model, in the context of levelized cost of water (LCOW) minimization for reverse osmosis (RO) and mechanical vapor compression systems. Process simulations and cost optimizations reveal that although all three models yield comparable LCOW and specific energy consumption (SEC) estimates under baseline conditions, deviations among their predictions increase with salinity. Relative differences in LCOW and SEC reach up to 6% and 8%, respectively. RO results show greater variability due to differences in osmotic pressure predictions, which affect pressure constraints at high recoveries. Computational performance varies substantially; specifically, Reaktoro simulations are up to 28 times slower than empirical models due to their detailed equilibrium calculations. These results suggest that empirical models offer acceptable accuracy for routine desalination process design, while Reaktoro provides advantages in scenarios requiring detailed speciation, such as scaling or pH adjustment studies. These findings underscore the importance of selecting appropriate property models based on the modeling objective of desalination applications and motivate future work integrating thermodynamic rigor with empirical efficiency.

Physical and chemical properties↗

Technical, Economic, Energetic, and Environmental Evaluation of Pretreatment Strategies for Scaling Control in Brackish Water Desalination Brine Treatment

Effective pretreatment is essential for achieving long-term stable operation and high water recovery during the desalination of alternative waters. This study developed a process modeling approach for technical, economic, energetic, and environmental assessments of pretreatment technologies to identify the impacts of each technology treating brackish water desalination brine with high scaling propensity. The model simulations evaluated individual pretreatment technologies, including chemical softening (CS), chemical coagulation (CC), electrocoagulation (EC), and ion exchange (IX). In addition, combinations of these pretreatment technologies aiming at the effective reduction of key scaling constituents such as hardness and silica were investigated. The three evaluation parameters in this assessment consist of levelized cost of water (LCOW, $/m 3 ), specific energy consumption and cumulative energy demand (SEC|CED, kWh/m 3 ), and carbon dioxide emissions (CO 2 , kg CO 2-eq /m 3 ). The case study evaluated in this work was the desalination brine from the Kay Bailey Hutchison Desalination Plant (KBHDP) with a total dissolved solids (TDS) concentration of 11,000 mg/L and rich in hardness and silica. The evaluation of individual pretreatment units from the highest to lowest LCOW, SEC|CED, and CO 2 emissions in the KBHDP brine was IX > CS > EC > CC, CS > IX > EC > CC, and CC > CS > EC > IX, respectively. In the case of pretreatment combinations for the KBHDP, the EC + IX treatment combination was shown to be the best in terms of the LCOW and CO 2 emissions. The modeling and evaluation of these pretreatment units provide valuable guidance on the selection of cost-effective, energy-efficient, and environmentally sustainable pretreatment technologies tailored to desalination brine applications for minimal- or zero-liquid discharge.

14 SOLAR ENERGY↗

Incorporating corrosion design constraints in desalination process optimization: A case study in mechanical vapor compression

Corrosion is an expensive and complex challenge for desalination, yet current design approaches do not explicitly account for corrosion mechanisms in process modeling and technoeconomic analysis. Here, to address this gap, we present a workflow for incorporating corrosion design constraints directly into desalination process optimization models. We develop surrogate models for general and localized corrosion metrics as functions of temperature, pH, salinity, dissolved oxygen, and material using data from OLI Systems’ Corrosion Analyzer. We then integrate these surrogates as corrosion design constraints in a cost-optimization MVC model that minimizes the levelized cost of water (LCOW). For a case study of mechanical vapor compression (MVC) treating seawater across a range of recoveries, we find dissolved oxygen (DO) is the dominant driver of localized corrosion, and thus of cost-optimal material choice and operating conditions. Reducing the DO from 8 mg/L to 0.5 mg/L reduces the LCOW by 15-35%, informing the breakeven costs for implementing DO removal or selecting highly corrosion-resistant alloys. This framework is broadly applicable across corrosion types, materials, and components and enables desalination process design that minimizes capital costs.

36 MATERIALS SCIENCE↗

An Innovative Zero-Liquid Discharge Intermediate-Cold-Liquid Eutectic-Freeze Desalination System

A novel freeze desalination technology is presented for purification of water produced from various industrial processes, including oil and gas extraction. The main innovative idea is introducing a water-immiscible intermediate-cold-liquid (ICL) medium which absorbs the cold from a refrigeration cycle and transfers it to a freezing chamber where it is mixed with brine. The cold ICL enters the freezing chamber at temperatures between -10°C to -30°C. Precooled brine in injected into the freezing chamber and pure water freezes out of the brine upon mixing with the ICL. The rate of freezing inside the chamber is controlled by adjusting the flow rate of the cold ICL relative to the inlet brine. Both eutectic freeze and non-eutectic freezing are possible by controlling the temperature of the freezing chamber. The solid-liquid slurry created in the freezing chamber flows to a filter separation unit after passing through a separation column. The ice crystals are separated from the liquid by a rotary filter device. The collected ice is rinsed by a centrifugal unit. The rinsed ice is melted to produce fresh water. The developed technology resolves the issues common to current freeze-desalination systems while offering superior heat transfer performance ascribed to direct-contact between the cooling medium and the brine in addition to producing solid salt and pure water. The system operates under atmospheric pressure. The low operation temperature minimizes the corrosion issues common in systems exposed to brine. Also, due to the low operating temperature, there are no concerns about evaporation of volatile organics from the produced water during the treatment. The developed technology effectively eliminates the use of chemicals for pretreatment of brine. The system can be constructed from commercially available components. Extensive testing using a lab-scale prototype by using synthetic brine and actual produced water with TDS values from 50,000 ppm to 300,000 ppm showed that freshwater could be achieved with relatively small dependency on the quality of the input brine. The quality of the treated water was found to be mainly a function of the duration of the centrifugal process. Treated water with TDS as low as 200 ppm could be achieved in the tests. Thermo-economic modeling coupled with system level thermochemical process model were developed for prediction of the LCOW. The LCOW was predicted to be $\$$0.50 to $\$$0.90 per barrel of produced water. The potential markets for deployment of the technology are the oil and gas, in-land thermoelectric powerplants, RO desalination plants, and mining industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Superstructure Optimization for Brine Valorization from Brackish Water Desalination

This poster presents preliminary results from a superstructure optimization framework developed to identify cost-optimal brine valorization configurations for brackish water desalination plants across diverse U.S. regional feed chemistries. The study uses brackish groundwater compositions from Arizona, California, Florida, New Mexico, and Texas. Using Pyomo Generalized Disjunctive Programming (GDP) within the WaterTAP modeling environment, the optimization framework simultaneously evaluates thousands of candidate treatment configurations, spanning nanofiltration, reverse osmosis, and chemical precipitation, to minimize the levelized cost of water (LCOW) while meeting water recovery targets and product recovery constraints. Results across eight representative feed clusters demonstrate water recovery rates of 57–87% and net LCOW values ranging from -$0.032/m³ (net revenue-positive) to $0.80/m. Notably, no single process configuration was optimal across all feed types, underscoring the necessity of feed-specific optimization. Products targeted include calcium carbonate (CaCO₃) at $0.01/kg and sodium chloride (NaCl) at $0.10/kg, both at 95% purity, with product revenues offsetting treatment costs in several scenarios. The work advances NAWI's process systems engineering capabilities for multi-configuration screening.

58 GEOSCIENCES↗

Techno-Economic Optimization of the SurgeWEC Device

This is the post-access report for a Teamer-funded effort to optimize the SurgeWEC device, a near-shore pivoting flap wave energy conversion device used to desalinate water. Parametrically driven cost and performance models enabled an integrated optimization approach at the farm scale. The metric used for this study was the levelized cost of water (LCOW). The data-set includes: 1. A public-domain post access report 2. An excel file with the data and plots generated under this study

16 TIDAL AND WAVE POWER↗

Comparative techno-economic assessment of osmotically-assisted reverse osmosis and batch-operated vacuum-air-gap membrane distillation for high-salinity water desalination

New developments in pressure- and thermally driven membrane desalination technologies offer the potential to cost-effectively treat high-salinity waters, especially when powered by low-cost solar electricity and thermal energy. This paper presents a comparative techno-economic assessment of the state-of-the-art most promising pressure- and thermally driven membrane technologies for high recovery desalination, namely, osmotically-assisted reverse osmosis (OARO) and batch-operated vacuum-air-gap membrane distillation (batch V-AGMD), to produce potable water while concentrating brine within the range of 140–290 g/L TDS for minimum-liquid-discharge (MLD) and zero-liquid-discharge (ZLD) applications. It is shown that both OARO and batch V-AGMD can treat feedwater and brines with TDS in the range of 30–125 g/L with corresponding fresh water recovery rates of 85–25%. When low cost solar electricity and thermal energy are used, the resulting levelized cost of water (LCOW) from OARO is in the range of 0.70–6.28 $/m 3 , and that from batch-V-AGMD is in the range of 1.74–2.77 $/m 3 . OARO is more cost-effective than batch V-AGMD when feedwater salinity is below 70 g/L and recovery below 75%, whereas batch V-AGMD is more cost-effective at higher recovery rates and salinity levels. Finally, the sensitivity of this comparison on energy prices and module costs is discussed.

42 ENGINEERING↗

Pipe Parity Analysis of Seawater Desalination in the United States: Exploring Costs, Energy, and Reliability via Case Studies and Scenarios of Emerging Technology

As climate change-induced variables exacerbate water scarcities, the use of seawater reverse osmosis (SWRO) membrane desalination technology for treating seawater could potentially provide a long-term drought-proof source of drinking water. This study carried out a technoeconomic assessment (TEA) for three SWRO desalination plants in the U.S. and one in Israel to set baselines for the cost and energy consumption for seawater desalination. In addition, a breakeven curve for implementing SWRO desalination was estimated in relation to the cost of water conservation measures to meet drought-induced reduction of the traditional water supply. The results show that the cost of SWRO water production scales with the plant capacity while energy intensity is not dramatically different across the plants. The higher cost in some U.S. plants is due to high capital investment, including land acquisition and permitting. Variations in plant capacity utilization have the greatest impact on the levelized cost of water (LCOW) over the plant service life, suggesting the importance of reducing fouling and maintenance-related downtime. Scenario analysis of fixed labor cost reduction through process automation indicates investments in automation and sensing technology could result in long-term savings. Breakeven analysis shows the decision to adopt SWRO is highly dependent on the local cost associated with water conservation to meet water supply reduction. Moreover, a small reduction in SWRO cost can influence a shift toward the adoption of SWRO over water conservation measures. Incorporation of future water demand, water conservation potential, and water stress data around the nation indicates SWRO desalination could be an important contributor to the future municipal drinking water portfolio in the U.S.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WaterTAP Technical Brief: Ion Exchange Model Demonstration and Optimization

Ion exchange is an important water treatment process for removal of targeted contaminants, including those associated with hardness. In this report, we introduce the ion exchange model developed for WaterTAP and present some example analysis of Ca 2+ removal for 0.1 MGD and 10 MGD systems. The model is a single-component, steady-state implementation that enables process optimization based on the influent ion concentration, resin capacity, and resin selectivity. Based on a survey of costing references for ion exchange, the WaterTAP ion exchange model returns reasonable estimates for the levelized cost of water (LCOW) of an ion exchange process, and performs as expected when critical design parameters, such as the resin capacity and selectivity, are varied.

54 ENVIRONMENTAL SCIENCES↗

Hawaii Solar Desalination Project

This project built the world’s largest Forward Osmosis (FO) solar thermal desalination plant at the NELHA Hawaii Ocean Science and Technology Park for a high visibility “on sun” demonstration of seawater desalination for agricultural applications. The project included re-commissioning an existing 2MW micro-dish solar thermal array and coupling it to a next-generation 500m3/day FO system. The purpose of the project was to validate FO at commercial scale; to verify that the water produced is safe for potential downstream agricultural users; to gather data on capital cost, energy consumption and operating expense for the technology; and to demonstrate that FO can be successfully coupled to low-grade thermal resources. The plant implemented advancements in FO component technology, including hot nano-filtration, polymeric heat exchangers, draw solutions, and improved FO membranes, and operated from June 2022 to September 2023 - producing 30gpm of permeate water. Thermal energy was below 30kWh/m 3 during operation, establishing a new benchmark in thermal desalination technology, with recovery rates at times exceeding 65%, well above what commercial RO systems can achieve. Combining the plant capital cost (CAPEX) and the operating expenses (OPEX) yields a Levelized Cost of Water (LCOW) that is competitive with existing carbon-intensive technologies such as RO. The ability of the plant to operate from a renewable resource paves the way toward a low-carbon desalination future using low-grade thermal resources.

14 SOLAR ENERGY↗

Produced Water Quality Standards & Techno-economic Analysis for Alternative Treatment Trains

This work presents NETL’s efforts in analyzing the performance and cost of a of water treatment trains for processing produced water. Levelized cost of water (LCOW) and specific energy consumption (SEC) figures are provided for both treatment trains. Permeate compositions are compared to the Type I produced water standards for the state of Texas.

low salt rejection reverse osmosis↗

Delivery of a Solar-Powered Forward Osmosis Seawater Desalination Plant: Trevi’s 500 m3/day Zero-Carbon FO Seawater Desalination Plant at NELHA

This paper presents an account of Trevi’s delivery of a 500 m3/day solar powered forward osmosis (FO) seawater desalination plant at the Ocean Science and Technology Park of the Natural Energy Laboratory of Hawaii Authority (NELHA). The project aimed to demonstrate the viability of solar thermal-powered desalination for agricultural applications through the integration of a 2MW micro-dish solar thermal array with a state-of-the-art FO system. Highlighted in the paper are the three distinct project phases; Planning and Design, System Construction, Installation & Testing followed finally by System Operation and Optimization. Results and decisions which led to the final plant design will be shared, highlighting how Trevi Systems succeeded in producing a zero-carbon FO seawater desalination plant with a projected Levelized Cost of Water (LCOW) estimate competitive with existing carbon-intensive RO technologies (based on some assumptions and the cost of heat which is required for FO.

14 SOLAR ENERGY↗