Search NASA⌕ Search

SEARCH · Search NASA

Results for “LEAD 188”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nuclear Data Sheets for A=188☆

Evaluated nuclear structure and decay data for all nuclei with mass number A=188 (Lu, Hf, Ta, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb, Bi, Po) are presented. The experimental data are compiled and evaluated, and best values for level and gamma-ray energies, quantum numbers, lifetimes, gamma-ray intensities, and other nuclear properties are recommended. Inconsistencies and discrepancies that exist in the literature are noted. This work supersedes the earlier evaluation by Balraj Singh (2002Si10), published in Nuclear Data Sheets 95, 387 (2002). The gamma-ray transition probabilities were calculated using the ENSDF analysis program ruler (www-nds.iaea.org/public/ensdf{sub p}gm/). However, the reader should be warned that the program may produce incorrect results when dealing with non-symmetric uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

g factors of coexisting isomeric states in {sup 188}Pb

The g factors of the 12{sup +}, 11{sup -}, and 8{sup -} isomeric states in {sup 188}Pb were measured using the time-differential perturbed angular distribution method as g(12{sup +})=-0.179(6), g(11{sup -})=+1.03(3), and g(8{sup -})=-0.037(7). The g factor of the 12{sup +} state follows the observed slight down-sloping evolution of the g factors of the i{sub 13/2}{sup 2} neutron spherical states with decreasing N. The g factors of the 11{sup -} and 8{sup -} isomers proposed as oblate and prolate deformed states, respectively, were interpreted within the rotational model, using calculated and empirical g factor values for the involved single-particle orbitals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recent Progress in the Negative-Ion-Based Neutral Beam Injectors in Large Helical Device

Negative-ion-based neutral beam injection (negative-NBI) system has been operated for 10 years in Large Helical Device (LHD). The injection power has been increased year by year, according to the improvement of the negative ion sources. Up to now, every injector achieves the designed injection energy and power of 180 keV-5 MW with hydrogen beams, and the total injection power exceeds 16 MW with three injectors. In the multi-round aperture grounded grid (GG), the diameter of a round aperture has been enlarged for higher GG transparency. Then, the GG heat load is reduced, as well as in the multi-slotted GG, and the voltage holding ability in the beam acceleration was improved. As a result, the beam energy is raised and the injection power is increased. To improve the anisotropic property of the beamlet convergence condition between the perpendicular and the parallel directions to the slots in the multi-slotted GG, a round-shape aperture of the steering grid (SG) has been changed to a racetrack shape. As a result, the difference of the beamlet conversion condition is much mitigated, and the injection efficiency (port-transmission efficiency) is improved, leading to 188 keV-6.4 MW injection. The Cs consumption is observed to be proportional to the tungsten evaporation from filaments. The Cs behavior is investigated with optical emission spectroscopy. During the beam extraction, the Cs recycling is dominated by Cs on the backplate, which is evaporated into the plasma by the backstreaming positive ions, and the wall surfaces should be loss regions for the supplied Cs.

43 PARTICLE ACCELERATORS↗

Adsorption of Non-Ionic Surfactant and Monoclonal Antibody on Siliconized Surface Studied by Neutron Reflectometry

The adsorption of monoclonal antibodies (mAbs) on hydrophobic surfaces is known to cause protein aggregation and degradation. Therefore, surfactants, such as Poloxamer 188, are widely used in therapeutic formulations to stabilize mAbs and protect mAbs from interacting with liquid-solid interfaces. Here, the adsorption of Poloxamer 188, one mAb and their competitive adsorption on a model hydrophobic siliconized surface is investigated with neutron scattering coupled with contrast variation to determine the molecular structure of adsorbed layers for each case. Small angle neutron scattering measurements of the affinity of Poloxamer 188 to this mAb indicate that there is negligible binding at these solution conditions. Neutron reflectometry measurements of the mAb show irreversible adsorption on the siliconized surface, which cannot be washed off with neat buffer. Poloxamer 188 can be adsorbed on the surface already occupied by mAb, which enables partial removal of some adsorbed mAb by washing with buffer. The adsorption of the surfactant introduces significant conformational changes for mAb molecules that remain on the surface. In contrast, if the siliconized surface is first saturated with the surfactant, no adsorption of mAb is observed. Competitive adsorption of mAb and Poloxamer 188 from solution leads to a surface dominantly occupied with surfactant molecules, whereas only a minor amount of mAb absorbs. These findings clearly indicate that Poloxamer 188 can protect against mAb adsorption as well as modify the adsorbed conformation of previously adsorbed mAb.

36 MATERIALS SCIENCE↗

Multi-quasiparticle excitation: Extending shape coexistence in A{approx}190 neutron-deficient nuclei

Multi-quasiparticle high-K states in neutron-deficient mercury, lead, and polonium isotopes have been investigated systematically by means of configuration-constrained potential-energy-surface calculations. An abundance of high-K states is predicted with both prolate and oblate shapes, which extends the shape coexistence of the mass region. Well-deformed shapes provide good conditions for the formation of isomers, as exemplified in {sup 188}Pb. Of particular interest is the prediction of low-lying 10{sup -} states in polonium isotopes, which indicate long-lived isomers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-particle spectroscopic factors for spherical nuclei

Within the self-consistent theory of finite Fermi systems, the total single-particle spectroscopic factors for seven doubly magic nuclei of {sup 40}Ca, {sup 48}Ca, {sup 56}Ni, {sup 78}Ni, {sup 100}Sn, {sup 132}Sn, and {sup 208}Pb and for the {sup 188–212}Pb chain of semimagic even lead isotopes are calculated by the energy-density-functional method implemented with a functional in the form proposed by Fayans and his coauthors. The spectroscopic factor is expressed in terms of the Z factor, which is the residue of the single-particle Green’s function at the single-particle pole. The total Z factor calculated in the present study involves both effects of coupling to phonons and the volume Z factor, which is due to the fact that the mass operator features an energy dependence not associated with surface phonons. The volume Z factor is on the same order of magnitude as the phonon-coupling contribution. The volume effect depends only slightly on the nuclear species and on the single-particle state λ. On the contrary, the phonon contribution to the total spectroscopic factor changes upon going over from one state to another and from one nuclear species to another.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Theoretical Yields for 188 W Production in the High Flux Isotope Reactor

Accurately predicting the production yield of 188 W and 191 Os from enriched 186W metal rings irradiated in HFIR is not straightforward. Two key factors can lead to significant uncertainty or inaccuracy in yield predictions: The effect of neutron flux depression in the dense tungsten metal target. Inaccuracy of the currently published 187 W thermal neutron absorption cross section. This manuscript reports the calculated yields for 188 W, 191 Os, and total osmium mass for the NM-888 target that was irradiated in High Flux Isotope Reactor (HFIR) Cycles 487 and 488. Three different yield calculation methods were used and are described herein. The results are presented in terms of total yield and in terms of yield per target mass. This allows for an approximate estimation of yields for future targets of varying mass loading but with similar irradiation profiles. For more accurate prediction yields, target-specific models that account for target loading, target positioning within HFIR, and accurate HFIR cycle data are required.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improvements to a cryosystem to observe ice nucleating in a variable pressure scanning electron microscope

The variable pressure scanning electron microscope (VPSEM) has expanded the scope of the SEM to allow the imaging of dynamic, electrically insulating systems. The use of water vapor as the imaging gas present in the chamber allows the successful imaging of hydrated samples. As awareness of the system capabilities becomes more well known, greater pressure has been put onto the microscopist to push the boundaries of both temperature and resolution for the study of diverse hydrated samples whose dynamics may not occur at the usual room temperatures in a VPSEM. In this article we discuss the stages in the development of a cryosystem that has led to the successful observation of the nucleation of ice from a solution in situ. This investigation also leads to further possibilities of imaging hydrated samples in the little explored temperature range of 188-238 K (from -85 to-35 deg. C). This study includes the exploration of how the temperature of various surfaces inside the microscope will change the system's ability to keep a sample hydrated or in its native state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New proton emitter 188 At implies an interaction unprecedented in heavy nuclei

We report the discovery of a new atomic nucleus 188 At, which is the heaviest proton-emitting isotope known to date. The new activity was observed through the 107 Ag( 84 Sr, 3n) 188 At fusion-evaporation reaction using the focal-plane spectrometer of the gas-filled recoil separator in the Accelerator Laboratory of the University of Jyväskylä, Finland. To fully interpret the experimental data, we have expanded the non-adiabatic quasiparticle model to treat nuclei in the beyond-lead region. The description reproduced the measured decay rate and pointed towards emission from an extremely prolate-deformed state with a dominant s 1/2 proton component in the wave function. The Thomas-Ehrman shift can be enhanced in low angular momentum states, but such effects have not been observed in heavy nuclei. The single-proton separation energy of 188 At deviates from that extrapolated from the systematics, which can be interpreted as the first evidence of this effect in heavy nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

{beta}{sup -}-delayed spectroscopy of neutron-rich tantalum nuclei: Shape evolution in neutron-rich tungsten isotopes

The low-lying structure of {sup 188,190,192}W has been studied following {beta} decays of the neutron-rich mother nuclei {sup 188,190,192}Ta produced following the projectile fragmentation of a 1-GeV-per-nucleon {sup 208}Pb primary beam on a natural beryllium target at the GSI Fragment Separator. The {beta}-decay half-lives of {sup 188}Ta, {sup 190}Ta, and {sup 192}Ta have been measured, with {gamma}-ray decays of low-lying states in their respective W daughter nuclei, using heavy-ion {beta}-{gamma} correlations and a position-sensitive silicon detector setup. The data provide information on the low-lying excited states in {sup 188}W, {sup 190}W, and {sup 192}W, which highlight a change in nuclear shape at {sup 190}W compared with that of lighter W isotopes. This evolution of ground-state structure along the W isotopic chain is discussed as evidence for a possible proton subshell effect for the A{approx}190 region and is consistent with maximization of the {gamma}-softness of the nuclear potential around N{approx}116.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First observation of a shape isomer and a low-lying strongly-coupled prolate band in neutron-deficient semi-magic 187 Pb

Prompt and delayed gamma-ray spectroscopy of the neutron-deficient, semi-magic isotope 187Pb has been performed using the recoil-decay and isomer-decay tagging techniques at the Argonne Gas-Filled Analyzer. A new 5.15(15)-mu s isomeric state at only 308 keV above the spherical 3/2 - ground state is identified and classified as a shape isomer. A strongly-coupled band is observed on top of the isomer, which is nearly identical to the one built on the prolate 7/2 - [514] Nilsson state in the isotone 185 Hg. Based on this similarity and on the result of the potential-energy surface calculations, the new isomer in 187 Pb is proposed to originate from the same configuration. The retarded character of the 308-keV (7/2( - )→ 3/2$_{gs}^{-}$ transition with a deduced B(E2) = 5.6(2) x 10 -4 W.u. can be well explained by the significant difference between the prolate parent and spherical daughter configurations, leading to the shape isomerism. The excitation energy of the isomer is surprisingly low, being roughly half of the excitation energies of the known 0 + intruder bandheads in the neighboring 186,188 Pb isotopes. The combined results of the present work and the previous alpha-decay and laser spectroscopy studies present evidence for triple shape coexistence at low energy in the negative-parity configurations of 187 Pb, which is well reproduced by the potential-energy surface calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multiplexed Oversampling Digitizer in 65 nm CMOS for Column-Parallel CCD Readout

A digitizer designed to read out column-parallel charge-coupled devices (CCDs) used for high-speed X-ray imaging is presented. The digitizer is included as part of the High-Speed Image Preprocessor with Oversampling (HIPPO) integrated circuit. The digitizer module comprises a multiplexed, oversampling, 12-bit, 80 MS/s pipelined Analog-to-Digital Converter (ADC) and a bank of four fast-settling sample-and-hold amplifiers to instrument four analog channels. The ADC multiplexes and oversamples to reduce its area to allow integration that is pitch-matched to the columns of the CCD. Novel design techniques are used to enable oversampling and multiplexing with a reduced power penalty. The ADC exhibits 188 ?V-rms noise which is less than 1 LSB at a 12-bit level. The prototype is implemented in a commercially available 65 nm CMOS process. The digitizer will lead to a proof-of-principle 2D 10 Gigapixel/s X-ray detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unraveling the Highly Plastic Behavior of ALD-Aluminum Oxide Encapsulations by Small-Scale Tensile Testing

We present a study directly measuring the electron-beam-induced plasticity of amorphous Al 2 O 3 coatings. Core–shell nanostructures are employed as small-scale model systems for two-dimensional coatings made by atomic layer deposition (ALD). Copper nanowires (NWs) are used as substrates for ALD deposition, representing a model system for interconnects commonly found in integrated circuits. Experiments are performed in situ in a transmission electron microscope (TEM) and further analyzed with electron energy loss spectroscopy (EELS). Our in situ TEM tensile experiments reveal the highly plastic behavior of the ALD shell, which withstands a maximum strain of 188%. Comparable samples under beam-off conditions show a brittle fracture, which underlines the effect of electron irradiation. The electron-beam-activated bond switching within the amorphous network enables compensation of the applied tensile strain, leading to viscous flow. By incorporating an intermediate nanocrystalline layer within the Al 2 O 3 shell, the plasticity is suppressed and brittle fracture occurs. This work directly demonstrates the tuning of mechanical properties in amorphous ALD structures through electron irradiation.

36 MATERIALS SCIENCE↗

Differences among Monte Carlo codes in the calculations of voxel S values for radionuclide targeted therapy and analysis of their impact on absorbed dose evaluations

Several updated Monte Carlo (MC) codes are available to perform calculations of voxel S values for radionuclide targeted therapy. The aim of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on absorbed dose evaluations performed by voxel dosimetry. Voxel S values for monoenergetic sources (electrons and photons) and different radionuclides ({sup 90}Y, {sup 131}I, and {sup 188}Re) were calculated. Simulations were performed in soft tissue. Three general-purpose MC codes were employed for simulating radiation transport: MCNP4C, EGSnrc, and GEANT4. The data published by the MIRD Committee in Pamphlet No. 17, obtained with the EGS4 MC code, were also included in the comparisons. The impact of the differences (in terms of voxel S values) among the MC codes was also studied by convolution calculations of the absorbed dose in a volume of interest. For uniform activity distribution of a given radionuclide, dose calculations were performed on spherical and elliptical volumes, varying the mass from 1 to 500 g. For simulations with monochromatic sources, differences for self-irradiation voxel S values were mostly confined within 10% for both photons and electrons, but with electron energy less than 500 keV, the voxel S values referred to the first neighbor voxels showed large differences (up to 130%, with respect to EGSnrc) among the updated MC codes. For radionuclide simulations, noticeable differences arose in voxel S values, especially in the bremsstrahlung tails, or when a high contribution from electrons with energy of less than 500 keV is involved. In particular, for {sup 90}Y the updated codes showed a remarkable divergence in the bremsstrahlung region (up to about 90% in terms of voxel S values) with respect to the EGS4 code. Further, variations were observed up to about 30%, for small source-target voxel distances, when low-energy electrons cover an important part of the emission spectrum of the radionuclide (in our case, for {sup 131}I). For {sup 90}Y and {sup 188}Re, the differences among the various codes have a negligible impact (within few percents) on convolution calculations of the absorbed dose; thus either one of the MC programs is suitable to produce voxel S values for radionuclide targeted therapy dosimetry. However, if a low-energy beta-emitting radionuclide is considered, these differences can affect also dose depositions at small source-target voxel distances, leading to more conspicuous variations (about 9% for {sup 131}I) when calculating the absorbed dose in the volume of interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CHANDRA ACIS SURVEY OF X-RAY POINT SOURCES IN 383 NEARBY GALAXIES. I. THE SOURCE CATALOG

The Chandra data archive is a treasure for various studies, and in this paper we exploit this valuable resource to study the X-ray point source populations in nearby galaxies. By 2007 December 14, 383 galaxies within 40 Mpc with isophotal major axis above 1 arcmin had been observed by 626 public ACIS observations, most of which were for the first time analyzed by this survey to study the X-ray point sources. Uniform data analysis procedures are applied to the 626 ACIS observations and lead to the detection of 28,099 point sources, which belong to 17,599 independent sources. These include 8700 sources observed twice or more and 1000 sources observed 10 times or more, providing us a wealth of data to study the long-term variability of these X-ray sources. Cross-correlation of these sources with galaxy isophotes led to 8519 sources within the D{sub 25} isophotes of 351 galaxies, 3305 sources between the D{sub 25} and 2D{sub 25} isophotes of 309 galaxies, and additionally 5735 sources outside 2D{sub 25} isophotes of galaxies. This survey has produced a uniform catalog, by far the largest, of 11,824 X-ray point sources within 2D{sub 25} isophotes of 380 galaxies. Contamination analysis using the log N-log S relation shows that 74% of sources within 2D{sub 25} isophotes above 10{sup 39} erg s{sup -1}, 71% of sources above 10{sup 38} erg s{sup -1}, 63% of sources above 10{sup 37} erg s{sup -1}, and 56% of all sources are truly associated with galaxies. Meticulous efforts have identified 234 X-ray sources with galactic nuclei of nearby galaxies. This archival survey leads to 300 ultraluminous X-ray sources (ULXs) with L{sub X} (0.3-8 keV) {>=} 2 x 10{sup 39} erg s{sup -1}within D{sub 25} isophotes, 179 ULXs between D{sub 25} and 2D{sub 25} isophotes, and a total of 479 ULXs within 188 host galaxies, with about 324 ULXs truly associated with host galaxies based on the contamination analysis. About 4% of the sources exhibited at least one supersoft phase, and 70 sources are classified as ultraluminous supersoft sources with L{sub X} (0.3-8 keV) {>=} 2 x 10{sup 38} erg s{sup -1}. With a uniform data set and good statistics, this survey enables future works on various topics, such as X-ray luminosity functions for the ordinary X-ray binary populations in different types of galaxies, and X-ray properties of galactic nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of Temperature on Properties and Dynamics of Gas-Solid Flow in Fluidized-Particle Tubular Solar Receiver

A fluidized particle single-tube solar receiver has been tested for investigating the gas-particle characteristics that enable the best operating conditions in a commercial-scale plant. The principle of the solar receiver is to fluidize the particles in a vessel – the dispenser – in which the receiver tube is plunged. The particles are flowing upward in the tube, irradiated over 1-meter height, by applying an overpressure in the dispenser. Experiments with a concentrated solar flux varying between 188 and 358 kW/m² are carried out, and the particle mass flux varied from 0 to 72 kg/(m²s). The mean particles and external tube wall temperatures in the irradiated zone are heated from the ambient to respectively 700°C and 940°C. It is shown that the temperature rise leads to a decrease of the particle volume fraction. Furthermore, a self-regulation of the system is evidenced with a short transient regime. This characteristic is essential from the operational viewpoint. The thermal efficiency of the receiver increases with the particle flow rate, reaching between 60 and 75% above 30 kg/(m²s). Several fluidization regimes are identified thanks to pressure signal analyses, like slugging, turbulent and fast fluidization, showing that regimes transitions are strongly affected by the temperature.

Gueguen, Ronny (ORCID:0000000252368638)↗

Experimental investigation of terahertz quantum cascade laser with variable barrier heights

We report an experimental study of terahertz quantum cascade lasers with variable barrier heights based on the Al{sub x}Ga{sub 1–x}As/GaAs material system. Two new designs are developed based on semiclassical ensemble Monte Carlo simulations using state-of-the-art Al{sub 0.15}Ga{sub 0.85}As/GaAs three-quantum-well resonant phonon depopulation active region design as a reference. The new designs achieved maximum lasing temperatures of 188 K and 172 K, as compared to the maximum lasing temperature of 191 K for the reference structure. These results demonstrate that terahertz quantum cascade laser designs with variable barrier heights provide a viable alternative to the traditional active region designs with fixed barrier composition. Additional design space offered by using variable barriers may lead to future improvements in the terahertz quantum cascade laser performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of temperature, oxygen partial pressure, and microstructure on the high-temperature oxidation behavior of the SiC Layer of TRISO particles

Tristructural isotropic (TRISO)-coated fuel particles are designed for use in high-temperature gas-cooled nuclear reactors, featuring a structural SiC layer that may be exposed to oxygen-rich environments over 1000 °C. Surrogate TRISO particles were tested in 0.2–20 kPa O 2 atmospheres to observe the differences in oxidation behavior. Oxide growth mechanisms remained consistent from 1200–1600 °C for each P O$_2$ , with activation energies of 228 ± 7 kJ/mol for 20 kPa O 2 and 188 ± 8 kJ/mol for 0.2 kPa O 2 . At 1600 °C, kinetic analysis revealed a change in oxide growth mechanisms between 0.2 and 6 kPa O2. In 0.2 kPa O 2 , oxidation produced raised oxide nodules on pockets with nanocrystalline SiC. Oxidation mechanisms were determined using Atom probe tomography. Active SiC oxidation occurred in C-rich grain boundaries with low P O$_2$ , leading to SiO 2 buildup in porous nodules. Here, this phenomenon was not observed at any temperature in 20 kPa O 2 environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗