Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIBS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Updates of the KArLE Experiment: New Libs Calibration Under High Vacuum for the Quantification of Potassium in Basalt for In Situ Geochronology

In planetary exploration, in situ absolute geochronology is one of the main important measurements that needs to be accomplished. Until now, on Mars, the age of the surface is only determined by crater density counting, which gives relative ages. These ages can have a lot of uncertainty as they depend on many parameters. More than that, the curves must be ties to absolute ages. Thus far, only the lost lander Beagle 2 was designed to conduct absolute geochronology measurements, though some recent attempts using MSL Curiosity show that this investigation is feasible and should be strongly encouraged for future flight. Experimental: The Potassium (K)-Argon Laser Experiment (KArLE) is being developed at MSFC through the NASA Planetary Instrument Definition and Development Program (PIDDP). The goal of this experiment is to provide in situ geochronology based on the K-Ar method. A laser ablates a rock under high vacuum, creating a plasma which is sensed by an optical spectrometer to do Laser Induced Breakdown Spectroscopy (LIBS). The ablated material frees gases, including radiogenic 40Ar,which is measured by a mass spectrometer (MS). As the potassium is a content and the 40Ar is a quantity, the ablated mass needed in order to relate them. The mass is given by the product of the ablated volume by the density of this material. So we determine the mineralogy of the ablated material with the LIBS spectra and images and calculate its density. The volume of the pit is measured by using microscopy. LIBS measurement of K under high vacuum: Three independant projects [1, 2, 3] including KArLE, are developing geochronological instruments based on this LA-LIBS-MS method. Despite several differences in their setup, all of them have validated the methods with analyses and ages. However, they all described difficulties with the LIBS measurements of K [3,4]. At ambient pressure, the quantification of K by LIBS on geological materials can be accurate [5]. However the protocol of the LA-LIBS-MS experiment required hundreds of shots under high vacuum in order to free enough 40Ar* to be measured by the QMS. This long duration of ablation may induces significant changes in the LIBS spectra. The pressure may increases by orders of magnitudewithin the chamber and the laser pit geometry can change the effectiveness of ablation and intensity of plasma light received. These effects introduce variation between the first and last spectra and so the quantification of K is more complex. The ablation of one crater can give, depending on the protocol of acquisition, from tens to hundreds of spectra. Protocol and results: We are in the process of further characterizing the variation introduced into LIBS spectra by the use of hundreds of laser shots, and definining a protocol that can be used to ensure accuracy and reporoducibility in the results.We are using natural rock powder standards fused in a furnace, as well as mars analog samples with known K content. We will show the result of the calibration and some new statistical approaches in order to apprehend the effects of the long time ablation on rocks under high vacuum.

Devismes, D.↗

Recent Advances in LIBS for Real-Time Detection of Silicone Contaminants on CFRP Surfaces

Laser induced breakdown spectroscopy (LIBS) is a materials characterization technique that has been advanced and refined to provide in situ, real-time quality control of carbon fiber reinforced polymer (CFRP) surfaces. As part of an effort to improve process control for adhesive bonding, a LIBS system was designed and assembled at NASA Langley Research Center (LaRC) to enable detection of ultralow concentrations of silicone contamination on CFRP adherends. The LIBS instrument provides high sensitivity detection and quasi-nondestructive surface characterization of CFRP adherends prior to adhesive bonding. This review focuses on the advancements at LaRC using LIBS as a quality control tool for the detection of silicone contaminants for improved adhesive bonding reliability of CFRP materials. This work describes how the LIBS technique was advanced by analyzing the laser parameters, studying the laser-matter interactions, and performing time-resolved measurements to determine the optimal plasma conditions for elemental detection. In addition, LIBS results were compared to X-ray photoelectron spectroscopy data to enable quantitative analysis from analytical calibration curves. Examples are shown of how to perform surface mapping of silicone contamination. Finally, a brief discussion is also presented on LIBS instrumentation, recommendations for laser parameters and instrumentation components, and LIBS technique maturity.

Surface characterization, Carbon fiber reinforced ↗

Recent Advances in LIBS for Real-Time Detection of Silicone Contaminants on CFRP Surfaces

Laser induced breakdown spectroscopy (LIBS) is a materials characterization technique that has been advanced and refined to provide in situ, real-time quality control of carbon fiber reinforced polymer (CFRP) surfaces. As part of an effort to improve process control for adhesive bonding, aLIBS system was designed and assembled at the NASA Langley Research Center (LaRC) to enable detection of ultra low concentrations of silicone contamination on CFRP adherends. The LIBS instrument provides high sensitivity detection and quasi-nondestructive surface characterization ofCFRP adherends prior to adhesive bonding. This review focuses on the advancements at LaRC using LIBS as a quality control tool for the detection of silicone contaminants for improved adhesive bonding reliability of CFRP materials. This work describes how the LIBS technique was advanced by analyzing the laser parameters, studying the laser-matter interactions, and performing time-resolved measurements to determine the optimal plasma conditions for elemental detection. In addition, LIBS results were compared to X-ray photoelectron spectroscopy data to enable quantitative analysis from analytical calibration curves. Examples are shown of how to perform surface mapping of silicone contamination. Finally, a brief discussion is presented on LIBS instrumentation, recommendations for laser parameters and instrumentation components, and LIBS technique maturity

Rodolfo I. Ledesma↗

Tandem LA-ICP-MS & LIBS; A New Micro-Analytical Technique for the Measurement of Every Element in the Periodic Table

Laser Ablation ICP-MS (LA-ICP-MS) has been widely accepted as a microanalytical technique for in-situ trace (ppb) elemental analysis on the micron scale in a variety of geologic materials. LA-ICP-MS (single or multi-collector) provides both elemental and isotopic measurements critical for a wide range of geological research by generating a fine grained aerosol (nm scale) during the laser ablation event and delivering that aerosol to the ICP ion source of the mass spectrometer via an inert carrier gas. LA-ICP-MS, however, suffers from limitations in analyzing high ionization potential elements as well as elements subject to atmospheric and argon based interferences. LA-ICP-MS also has limitations in analyzing major elements due to detector saturation. An alternative laser ablation technique, Laser Induced Breakdown Spectroscopy (LIBS), employs an optical spectrometer integrated into the laser ablation system that analyzes the laser induced plasma at the sample surface across the entire optical spectrum for emission lines of every element in the periodic table. Elements that are difficult or impossible to measure with LA-ICP-MS are now possible to analyze with LIBS down to low ppm levels with CCD and/or ICCD detection. We introduce a new laser based technique, “Tandem LA-LIBS”, that combines LA for ICP-MS and LIBS into one integrated laser ablation system. This system has the effect of expanding the elemental coverage and the dynamic range of the laser ablation experiment as measurements from ppb to % level matrix elements can now be analyzed in a single ablation experiment. We present both femtosecond and nanosecond Tandem LA-LIBS quantitative and qualitative data on wide range of geological materials for those elements that are difficult or impossible by traditional LA-ICP-MS techniques such as F, H, O, N, C, S, halogens, etc. We also demonstrate that the simultaneous measurement of trace, minor and major elements are now possible in a single laser ablation experiment with Tandem LA-LIBS technology.

LA-ICP-MS↗

Downhole Elemental Analysis with LIBS

In this paper we discuss a novel instrument, currently under development at Honeybee Robotics with SBIR funding from NASA. The device is designed to characterize elemental composition as a function of depth in non-terrestrial geological formations. The instrument consists of a miniaturized laser-induced breakdown spectrometer (LIBS) analyzer integrated in a 2" diameter drill string. While the drill provides subsurface access, the LIBS analyzer provides information on the elemental composition of the borehole wall. This instrument has a variety of space applications ranging from exploration of the Moon for which it was originally designed, to Mars, as well as a variety of terrestrial applications. Subsurface analysis is usually performed by sample acquisition through a drill or excavator, followed by sample preparation and subsequent sample presentation to an instrument or suite of instruments. An alternative approach consisting in bringing a miniaturized version of the instrument to the sample has many advantages over the traditional methodology, as it allows faster response, reduced probability of cross-contamination and a simplification in the sampling mechanisms. LIBS functions by focusing a high energy laser on a material inducing a plasma consisting of a small fraction of the material under analysis. Optical emission from the plasma, analyzed by a spectrometer, can be used to determine elemental composition. A triangulation sensor located in the sensor head determines the distance of the sensor from the borehole wall. An actuator modifies the position of the sensor accordingly, in order to compensate for changes due to the profile of the borehole walls. This is necessary because LIBS measurements are negatively affected by changes in the relative position of the focus of the laser with respect to the position of the sample (commonly referred to as the "lens to sample distance"). Profiling the borehole is done by adjusting the position of the sensor with a vertical stage; a second actuator at the top of the downhole probe allows radial scanning of the borehole. Analysis of iron and titanium in lunar simulant with LIBS was performed in air using the method of standard addition. The results for lunar simulant NU-LHT-2M show a value for the concentration of iron ranging between 2.29% and 3.05% depending on the atomic line selected. The accepted value for the sample analyzed is 2.83%, showing the capability for the system in development to provide qualitative and semi-quantitative analysis in real-time.

Moreschini, Paolo↗

Partial Least Squares and Neural Networks for Quantitative Calibration of Laser-induced Breakdown Spectroscopy (LIBs) of Geologic Samples

The ChemCam instrument [1] on the Mars Science Laboratory (MSL) rover will be used to obtain the chemical composition of surface targets within 7 m of the rover using Laser Induced Breakdown Spectroscopy (LIBS). ChemCam analyzes atomic emission spectra (240-800 nm) from a plasma created by a pulsed Nd:KGW 1067 nm laser. The LIBS spectra can be used in a semiquantitative way to rapidly classify targets (e.g., basalt, andesite, carbonate, sulfate, etc.) and in a quantitative way to estimate their major and minor element chemical compositions. Quantitative chemical analysis from LIBS spectra is complicated by a number of factors, including chemical matrix effects [2]. Recent work has shown promising results using multivariate techniques such as partial least squares (PLS) regression and artificial neural networks (ANN) to predict elemental abundances in samples [e.g. 2-6]. To develop, refine, and evaluate analysis schemes for LIBS spectra of geologic materials, we collected spectra of a diverse set of well-characterized natural geologic samples and are comparing the predictive abilities of PLS, cascade correlation ANN (CC-ANN) and multilayer perceptron ANN (MLP-ANN) analysis procedures.

Anderson, R. B.↗

Relationship between LIBS Ablation and Pit Volume for Geologic Samples: Applications for in situ Absolute Geochronology

In planetary sciences, in situ absolute geochronology is a scientific and engineering challenge. Currently, the age of the Martian surface can only be determined by crater density counting. However this method has significant uncertainties and needs to be calibrated with absolute ages. We are developing an instrument to acquire in situ absolute geochronology based on the K‐Ar method. The protocol is based on the laser ablation of a rock by hundreds of laser pulses. Laser Induced Breakdown Spectroscopy (LIBS) gives the potassium content of the ablated material and a mass spectrometer (quadrupole or ion trap) measures the quantity of 40Ar released. In order to accurately measure the quantity of released 40Ar in cases where Ar is an atmospheric constituent (e.g., Mars), the sample is first put into a chamber under high vacuum. The 40Arquantity, the concentration of K and the estimation of the ablated mass are the parameters needed to give the age of the rocks. The main uncertainties with this method are directly linked to the measures of the mass (typically some μg) and of the concentration of K by LIBS (up to 10%). Because the ablated mass is small compared to the mass of the sample, and because material is redeposited onto the sample after ablation, it is not possible to directly measure the ablated mass. Our current protocol measures the ablated volume and estimates the sample density to calculate ablated mass. The precision and accuracy of this method may be improved by using knowledge of the sample's geologic properties to predict its response to laser ablation, i.e., understanding whether natural samples have a predictable relationship between laser energy deposited and resultant ablation volume. In contrast to most previous studies of laser ablation, theoretical equations are not highly applicable. The reasons are numerous, but the most important are: a) geologic rocks are complex, polymineralic materials; b) the conditions of ablation are unusual (for example, variable vacuum pressure), and c) the ablation is made with hundreds of successive laser pulses. In this work, we aim to understand the effects that occur on LIBS spectra when a homogeneous rock or a mineral is ablated under high vacuum. Understanding these effects is important to define best practices for LIBS measurements and may lead to improved measurement (or possibly prediction) of the ablated volume. We will describe our laboratory approach and first results, and discuss its utility for situ absolute geochronology campaigns.

Devismes, D.↗

Determination of Trace Silicone Contamination on Composites by Quantitative XPS and LIBS

Surface treatment and surface characterization techniques are critical to ensure that adherends are chemically activated and free of contaminants prior to adhesive bonding. Silicone contamination from mold-release agents and other sources can interfere with interfacial bonding, decreasing the durability and performance of bonded composite structures. Tools and methods are needed that can be used in a production environment to reliably detect low levels of contaminants in a rapid, simple, and cost-effective manner to improve bond reliability. In this work, surface characterization of carbon fiber reinforced polymer (CFRP) composites was performed using laser induced breakdown spectroscopy (LIBS) and the results were compared with those obtained from X-ray photoelectron spectroscopy (XPS). The objective was to investigate the ability to quantify the surface species measured by LIBS since it offers many advantages over XPS in terms of ease of use, sample preparation, and real-time results. The as-processed CFRP panels had trace surface silicone contamination from the fabrication process, the source of which was not investigated. The composites were laser treated at select average laser power levels, resulting in varying levels of contamination reduction. The Si atomic percentage measurements using XPS were conducted both before and after laser ablation. The XPS results were compared with those obtained from LIBS to assess the reliability of each technique for surface contaminant characterization. The results showed an excellent correlation in Si atomic concentration between the two techniques.

Ledesma, Rodolfo↗

A Review of LIBS for Real-Time Detection of Trace Silicone Contaminants on CFRP Surfaces

Laser ablation is the removal of material by laser pulses through photochemical, photothermal, or photophysical mechanisms, which is useful to prepare an adherend surface for adhesive bonding. Laser surface treatment is a method that has been under research for the past decade at NASA Langley Research Center (LaRC) to prepare surfaces for adhesive joining of aerospace composite materials and metallic alloys. Laser ablation of composite materials increases surface area and removes the surface contaminants introduced during material handling and fabrication processes. By adjustment of laser parameters, it is possible to obtain repeatable surface conditions, and superficial contaminants can be selectively and efficiently removed without damaging the underlying carbon fibers or the carbon fiber reinforced polymer (CFRP) substrate. Laser induced breakdown spectroscopy (LIBS) is a surface characterization and inspection technique that can be seamlessly integrated into the laser surface treatment process. At NASA LaRC, a single laser system has been used for both laser surface treatment and LIBS, which enables in-situ monitoring of surface contaminants. This work focuses on the advancements at LaRC using LIBS to detect surface silicone contaminants on aerospace CFRP materials and to provide surface quality control in adhesive bonding.

Rodolfo I Ledesma↗

A Review of LIBS for Real-Time Detection of Trace Silicone Contaminants on CFRP Surfaces

Laser ablation is the removal of material by laser pulses through photochemical, photothermal, or photophysical mechanisms, which is useful to prepare an adherend surface for adhesive bonding. Laser surface treatment is a method that has been under research for the past decade at NASA Langley Research Center (LaRC) to prepare surfaces for adhesive joining of aerospace composite materials and metallic alloys. Laser ablation of composite materials increases surface area and removes the surface contaminants introduced during material handling and fabrication processes. By adjustment of laser parameters, it is possible to obtain repeatable surface conditions, and superficial contaminants can be selectively and efficiently removed without damaging the underlying carbon fibers or the carbon fiber reinforced polymer (CFRP) substrate. Laser induced breakdown spectroscopy (LIBS) is a surface characterization and inspection technique that can be seamlessly integrated into the laser surface treatment process. At NASA LaRC, a single laser system has been used for both laser surface treatment and LIBS, which enables in-situ monitoring of surface contaminants. This work focuses on the advancements at LaRC using LIBS to detect surface silicone contaminants on aerospace CFRP materials and to provide surface quality control in adhesive bonding.

Rodolfo I Ledesma↗

Calibration of the Fluorine, Chlorine and Hydrogen Content of Apatites With the ChemCam LIBS Instrument

Determining the composition of apatites is important to understand the behavior of volatiles during planetary differentiation. Apatite is an ubiquitous magmatic mineral in the SNC meteorites. It is a significant reservoir of halogens in these meteorites and has been used to estimate the halogen budget of Mars. Apatites have been identified in sandstones and pebbles at Gale crater by ChemCam, a Laser-Induced Breakdown Spectroscometer (LIBS) instrument onboard the Curiosity rover. Their presence was inferred from correlations between calcium, fluorine (using the CaF molecular band centered near 603 nm, whose detection limit is much lower that atomic or ionic lines and, in some cases, phosphorus (whose detection limit is much larger). An initial quantification of fluorine, based on fluorite (CaF2)/basalt mixtures and obtained at the LANL laboratory, indicated that the excess of F/Ca (compared to the stoichiometry of pure fluorapatites) found on Mars in some cases could be explained by the presence of fluorite. Chlorine was not detected in these targets, at least above a detection limit of 0.6 wt% estimated from. Fluorapatite was later also detected by X-ray diffraction (with CheMin) at a level of approx.1wt% in the Windjana drill sample (Kimberley area), and several points analyzed by ChemCam in this area also revealed a correlation between Ca and F. The in situ detection of F-rich, Cl-poor apatites contrasts with the Cl-rich, F-poor compositions of apatites found in basaltic shergottites and in gabbroic clasts from the martian meteorite NWA 7034, which were also found to be more Cl-rich than apatites from basalts on Earth, the Moon, or Vesta. The in situ observations could call into question one of the few possible explanations brought forward to explain the SNC results, namely that Mars may be highly depleted in fluorine. The purpose of the present study is to refine the calibration of the F, Cl, OH and P signals measured by the ChemCam LIBS instrument, initiated for F, for Cl in soils, for P, and estimate their limit of detection. For this purpose, different types of apatites and mixtures of basalt powder and apatites were analyzed using ChemCam Engineering Qualification Model (EQM) at IRAP, Toulouse. The present abstract presents the initial results from the laboratory analyses. Differences between the response function of the EQM and the Flight Model of ChemCam are still to be refined to apply these new results to the Martian dataset.

Meslin, P.-Y.↗

The Low-Lying Electronic States of LiB

The spectroscopic constants for the triplet and singlet states of LiB below about 30 000/ cm are determined using an internally contracted multireference configuration interaction approach in conjunction with [6s 5p 3d 2f] atomic natural orbital basis sets. The ground state is (sup 3)Pi as found in previous work. No excited triplet states are found to be ideal for characterizing the ground state; the (1)(sup 3)Sigma(sup -) state has a transition energy that is too small for many experimental approaches and the (2)(sup 3)Pi and (3)(sup 3)Pi states have bond lengths that are significantly longer than the ground state, resulting in transition intensities that are spread out over many vibrational levels of the ground state.

Ricca, Alessandra↗

A Combined Remote LIBS and Raman Spectroscopic Study of Minerals

In this paper, we explore the use of remote LIBS combined with pulsed-laser Raman spectroscopy for mineral analysis at a distance of 10 meters. Samples analyzed include: carbonates (both biogenic and abiogenic), silicates, and sulfates. Additional information is contained in the original extended abstract.

Hubble, H. W.↗

Analyses of IR-Stealthy and Coated Surface Materials: A Comparison of LIBS and Reflectance Spectra and Their Application to Mars Surface Exploration

Identification of non-silicate samples on Mars, such as carbonates, sulfates, nitrates, or evaporites in general, is important because of their association with aqueous processes and their potential as exobiology sites. Infrared (IR) and thermal emission (TE) spectroscopy have been considered the primary tools for remote identification of these minerals. This includes current and future orbital assets such as TES on MGS, THEMIS on Mars Odyssey, OMEGA on Mars Express, CRISM on MRO, and now the Mini-TES on the MER rovers. While reflectance and emission spectroscopy have clearly been the method of choice for these missions, the technique is not always successful in mineral identifications due to dust, surface weathering chemistry, coatings, or surface texture. Here we describe and show IR spectra of several such samples, and then report on the relative success of LIBS analyses in determining the rock type.

Wiens, R. C.↗

Relationship Between LIBS Ablation and Pit Volume for Geologic Samples: Applications for the In Situ Absolute Geochronology

These first results demonstrate that LIBS spectra can be an interesting tool to estimate the ablated volume. When the ablated volume is bigger than 9.10(exp 6) cubic micrometers, this method has less than 10% of uncertainties. Far enough to be directly implemented in the KArLE experiment protocol. Nevertheless, depending on the samples and their mean grain size, the difficulty to have homogeneous spectra will increase with the ablated volume. Several K-Ar dating studies based on this approach will be implemented. After that, the results will be shown and discussed.

Devismes, Damien↗

Exploration of Mars with the ChemCam LIBS Instrument and the Curiosity Rover

The Mars Science Laboratory (MSL) Curiosity rover landed on Mars in August 2012, and has been exploring the planet ever since. Dr. Horton E. Newsom will discuss the MSL's design and main goal, which is to characterize past environments that may have been conducive to the evolution and sustainability of life. He will also discuss Curiosity's science payload, and remote sensing, analytical capabilities, and direct discoveries of the Chemistry & Camera (ChemCam) instrument, which is the first Laser Induced Breakdown Spectrometer (LIBS) to operate on another planetary surface and determine the chemistry of the rocks and soils.

Newsom, Horton E.↗