Lifetime Extension Report: Progress on the SAVY-4000 Lifetime Extension Program

The 3-year accelerated aging study of the SAVY-4000 O-ring shows very little evidence of significant degradation to samples subjected to aggressive elevated temperature and radiation conditions. Whole container thermal aging studies followed by helium leakage testing and compression set measurements were used to establish an estimate for a failure criterion for O-ring compression set of ≥65 %. The whole container aging studies further show that the air flow and efficiency functions of the filter do not degrade significantly after thermal aging. However, the degradation of the water-resistant function leads to water penetration failure after four months at 210°C, but does not cause failure after 10 months at 120°C (130°C is the maximum operating temperature for the PTFE membrane). The thermal aging data for O-ring compression set do not meet the assumptions of standard time-temperature superposition analysis for accelerated aging studies. Instead, the data suggest that multiple degradation mechanisms are operative, with a reversible mechanism operative at low aging temperatures and an irreversible mechanism dominating at high aging temperatures. To distinguish between these mechanisms, we have measured compression set after allowing the sample to physically relax, thereby minimizing the effect of the reversible mechanism. The resulting data were analyzed using two distinct mathematical methods to obtain a lifetime estimate based on chemical degradation alone. Both methods support a lifetime estimate of greater than 150 years at 80°C. Although the role of the reversible mechanism is not fully understood, it is clear that the contribution to the total compression set is small in comparison to that due to the chemical degradation mechanism. To better understand the chemical degradation mechanism, thermally aged O-ring samples have been characterized by Fourier Transform Infrared (FTIR), Electron Paramagnetic Resonance (EPR), Gel Permeation Chromatography (GPC), and Differential Scanning Calorimetry (DSC). These experiments detect no significant O-ring degradation below 80°C. Furthermore, durometer measurements indicate that there is no significant change in O-ring hardness at all aging conditions examined. Therefore, our current conservative lifetime estimate for the O-ring and the filter is 10 years at 80°C. In FY17, we will continue to probe the chemical degradation mechanism using oxygen consumption measurements under accelerated aging conditions to reveal temperatures at which oxidation occurs, along with any differences in oxidation rate at the low vs. high aging temperatures. We will also refine the failure criteria and finalize the radiation/thermal synergistic studies to determine a final design lifetime.

42 ENGINEERING↗

Added value of site load measurements in probabilistic lifetime extension: a Lillgrund case study

Site-specific fatigue estimation is an essential part of wind turbine lifetime extension, with various methods depending on data availability. The present study compares probabilistic lifetime extension assessment results for rotor blades with and without load measurements. It also addresses two key questions in such assessments: the applicability of the Frandsen model for estimating waked turbulence under complex and mixed wake conditions and the extrapolation of mid-term data over longer time periods. The case study wind turbine is SWT-2.3-93, located at the edge of the Lillgrund wind farm, situated in the Øresund Strait between Denmark and Sweden. The turbine is extensively instrumented, with 5 years of data available from its supervisory control and data acquisition (SCADA) system. Although the Frandsen turbulence estimates deviate in a different manner from measurements at below- and above-rated mean wind speeds, the model remains a conservative approach for fatigue load prediction and reliability. In the current case study, the site-specific assessment using strain gauge measurements yields a 33 % higher annual fatigue reliability index after 35 years compared to a scenario based on the Frandsen estimation combined with ambient environmental data and a generic aeroelastic model. The results also demonstrate that the sensitivity of fatigue reliability to load uncertainty is negligible when load measurements are used directly but relatively high when relying on the Frandsen model in combination with a generic aeroelastic model. Overall, the high variability of the lifetime extension in different scenarios of data availability and accuracy shows the importance and added value of high-quality measurements combined with wind-farm-level SCADA and a model updated in real time (digital twins).

17 WIND ENERGY↗

Reactor lifetime extension by limiting the RPV fluence increase

Lifetime extension of Pressurized Water Reactors must consider the embrittlement of the reactor pressure vessel. AREVA NP has a long history in developing and implementing problem oriented shielding measures. The main goal of these measures is the reduction of the fast flux at the original core periphery. Dependent on the size of the problem, the measures can be characterized as optimization of core design, insertion of neutron absorber material in regular fuel assemblies at the core periphery, partly inert assemblies, and fully inert assemblies. The first two solutions can in principal be handled with standard tools. Special measures had to be developed for the neutronic description of the other two options. These newly developed methodologies are based on the Equivalence Theory that was developed at AREVA NP in the late 1970's and early 1980's and is applied for the description of inert fuel assemblies as well as for reflectors in its code systems. The implemented solutions were accompanied by measurement programs for qualification of the design methods and for confirmation of the predicted shielding effect. The design shielding ratios of the developed measures cover a range of approximately 1.5 to 10 with the shielding ratio being defined as the ratio of vessel fluence per time interval of a core without shielding to a core with shielding provision. The comparisons of calculation and measurement verify the projected behavior of the shielding measures. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SAVY-4000 O-Ring and Filter Lifetime Extension Report

The 3-year accelerated aging study of the SAVY-4000 O-ring detailed in our previous Lifetime Extension Report showed very little evidence of significant degradation to samples subjected to aggressive elevated temperature and radiation conditions. Whole container thermal aging studies followed by helium leakage testing and compression set measurements were used to establish a failure criterion estimate for O-ring compression set of ≥ 65 %, which led to an O-ring lifetime estimate of greater than 65 years at 80°C. Herein, we describe a statistical model of the 3-year accelerated aging study and present additional results gathered in FY17 that further support the lifetime extension of the O-ring to 40 years at 80°C. Because we are choosing an extremely conservative lifetime value (40 years) compared to the aging study results (>65 years), the O-ring lifetime could be extended further, especially if supported by surveillance results collected over the years to come.

36 MATERIALS SCIENCE↗

Overview of SAVY-4000 Lifetime Extension Activities in Fiscal Year 2024

This report provides an overview of activities engaged in during the 2024 fiscal year in support of the SAVY-4000 (hereafter “SAVY”) lifetime extension. As the final full year prior to the submittal of the technical basis, efforts were made to assess the current understanding regarding SAVY degradation in service as well as any knowledge that provided a more substantive view of the challenges that SAVYs face in storage. Close coordination with the stakeholders (i.e. LANL program office) ensured alignment with expectations regarding timelines for the remainder of the activities supporting the technical basis document for the lifetime extension request.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NMPWG Discussion on - Tracking Initial SAVY-4000 Population and Lifetime Extensions Across the DOE Complex [Slides]

As part of LANL's SAVY-4000 Lifetime Extension efforts, the question of "when does a SAVY's life start?" was posed. The unfortunate answer that can be agreed upon is to start the life based on the serial number which includes month and date of manufacture. For example - 012405025 was a 5QT container produced in January of 2024. This is not the most efficient way to track age of a container if extended lifetimes and usage are desired. Other possibilities include: Tracking on first-use date (date it was loaded); Tracking when it was sold from the warehouse to an operating group for use; Tracing the amount of time nuclear material is within the container (LANMAS transaction histories).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lifetime Extension of the Stainless-Steel Components of the SAVY-4000 Storage Container - 18572

Surveillance of vented, stainless-steel Hagan and SAVY-4000 storage containers with some plutonium materials have revealed evidence of corrosion inside the container. There are ∼3000 items stored in Hagan containers and ∼600 items currently stored in SAVY-4000 containers at TA-55. The Hagan is made of 304L steel while the SAVY is made of 316L and should be less susceptible to corrosion. Given the relatively thin body wall of these containers (nominally 0.762 millimeters), it is essential to understand the effects of corrosion on the lifetime of the containers to ensure worker safety. Studies are being conducted on both container types to determine the relative susceptibility of the two containers to corrosion. This paper will describe the potential cause of the corrosion, the extent of corrosion, the types of corrosion observed, along with the results of accelerating aging experiments. The combined results of the surveillance and lifetime extension studies will be used to predict the container lifetime. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CNL Calandria Lifetime Extension Program: 1st Capsule Assembly

This report provides documentation and a summary of all 18 capsules assembled for the Canadian Nuclear Laboratories (CNL) Calandria Lifetime Extension Program. This is the first set of capsules in a series of two irradiation campaigns to provide data relevant to weldments in the calandria of Canada deuterium uranium (CANDU) reactors. This report provides documentation on capsule IDs, specimen IDs, and capsule locations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lifetime Extension of the Gas Discharge Detectors with Plasma Etching of Silicon Deposits in 80%CF{sub 4} + 20%CO{sub 2}

A method of elimination of silicon compounds from the anode wire of an aged proportional counter is presented. The aging of a counter with a 70%Ar + 30%CO{sub 2} and a 60%Ar + 30%CO{sub 2} + 10%СF{sub 4} working mixture was stimulated by a {sup 90}Sr β source. To accelerate the process of aging, the gas mixture flow to the counter was supplied through a pipe with RTV coated wall. As a result, the amplitude of the signal decreased 70% already at accumulated charge of Q = 0.03 C/cm. The etching of the silicon compounds on the wire surface with an 80%CF{sub 4} + 20%CO{sub 2} gas mixture discharge led to full recovery of the operating characteristics of detector and an increase in the lifetime. A scanning electron microscopy and X-ray spectroscopy analysis of the recovered wire surface were performed. In accordance with the results, a good quality of wire cleaning from SiO{sub 2} compounds was obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low drag attitude control for Skylab orbital lifetime extension

In the fall of 1977 it was determined that Skylab had started to tumble and that the original orbit lifetime predictions were much too optimistic. A decision had to be made whether to accept an early uncontrolled reentry with its inherent risks or try to attempt to control Skylab to a lower drag attitude in the hope that there was enough time to develop a Teleoperator Retrieval System, bring it up on the Space Shuttle and then decide whether to boost Skylab to a higher longer life orbit or to reenter it in a controlled fashion. The end-on-velocity (EOVV) control method is documented, which was successfully applied for about half a year to keep Skylab in a low drag attitude with the aid of the control moment gyros and a minimal expenditure of attitude control gas.

Glaese, J. R.↗

SAVY-4000 Lifetime Extension Overview for FY23

The SAVY-4000 (hereafter “SAVY) was granted a 15 year design life as of June 11, 2019. Since that time, a concerted effort to evaluate the SAVY lifetime beyond 15 years initiated. Several key gaps in knowledge were identified by subject matter expert reviewers across the complex, along with testing that should be included or addressed in the next technical basis. While surveillance has not fundamentally changed since the last life extension, many key techniques have since been identified as necessary to evaluate key container performance requirements not addressed previously (i.e. drop qualification release rate). FY23 provided an opportunity to establish the groundwork for the development of those key techniques that aid in addressing DOE Manual 441.1-1 (hereafter “Manual”) requirements for safe storage of nuclear material.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lifetime extension of legacy CEBAF LLRF hardware

A significant portion of the Low-Level Radio Frequency (LLRF) hardware in Jefferson Lab’s CEBAF is from the original construction of the facility using 1980’s CAMAC technology. Of the fifty-three zones in CEBAF, thirty-six of them are legacy hardware. The age of the legacy system has led to difficulties in maintaining the hardware due to parts going obsolete without suitable drop in replacements. Continued operation of the legacy system is required as the installation of LLRF 3.0 systems is costly and cannot be completed in a short period of time with the available resources. The most pressing failure in the legacy system was a failing buffer card, which is responsible for communication between the EPICs network and individual RF control modules. A new buffer card was designed as a transparent, drop in, replacement so that upgrades are simply a matter of swapping the existing legacy hardware. This buffer card upgrades a single point failure component and promises to extend the operable lifetime of CEBAF’s legacy systems.

Accelerator Physics↗

Lifetime extension drop-test of real-world corroded 5 Quart Hagan nuclear material storage container

A 5Qt Hagan container with a 20-year history of nuclear material storage was challenged with three successive drop tests at a height of 3.7 meters. The total mass of the test package was 12.1 kg. The 1st and 2nd drop tests (center of gravity over the container bottom corner but 180 degrees apart on the container bottom face) passed the pre- and post- impact helium leak criterion at less than 1.00E-6 atm-cc/sec (ambient cubic centimeters per second). The 3rd and final test (center of gravity over top corner) failed with a post-impact gross leak of 1.1E-1 atmcc/sec. The RRFMC (Respirable Release Fraction Measurement Chamber) is a drop tower test system that is critical for the sustainability of the SAVY-4000™ series and Hagan-type (NFT Inc. Golden CO) nuclear material storage containers. These are the primary in-use nuclear material storage container types at the Los Alamos National Laboratory TA-55 facility. Results are presented to expand the technical knowledge basis for container lifetime, regarding actual exposure to corrosive gas species on the container inner surfaces. The primary source of general corrosion throughout the container is gaseous hydrogen chloride (HCl). This gas is generated by the degradation of the polyvinylchloride (PVC) bag-out bag. Additionally, in most cases, the nuclear material itself also releases HCl gas (due to residual chemical components associated with the material formation). The RRFMC drop tower gives the end-user the ability record and analyze high-speed video and photography and if needed aerosol mass release measurements. In this report the principal issue is the physical deformation of the 5Qt Hagan container. There were no mass release experiments of test aerosol mass in the present study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SAVY O-ring characterization for lifetime extension

Los Alamos National Laboratory and Nuclear Filter Technology, Inc. developed the SAVY-4000 nuclear material storage container, named after the designers Stone, Anderson, Viers, and Yarbro. The SAVY 4000 meets the requirements of Department of Energy (DOE) M 441.1-1,2 Nuclear Material Packaging Manual, to protect workers who handle nuclear materials against radiation exposures resulting from the leakage of stored materials. The SAVY-4000 is an innovative and creative design: it can be opened and closed in a few seconds without using torque wrenches and instead only a tire iron or equivalent prying tool; has a built-in, fire-rated filter that prevents the build-up of hydrogen gas yet retains 99.97% of plutonium particulates at 200 ACCM rated flow; and prevents the release of stored materials upon a 12- foot drop.

42 ENGINEERING↗